期刊文献+
共找到125篇文章
< 1 2 7 >
每页显示 20 50 100
Wave Motion of Smoke in Subway Fire Environment 被引量:1
1
作者 吴文忠 由世俊 《Transactions of Tianjin University》 EI CAS 2009年第3期206-209,共4页
Wave motion in subway or tunnel fire is an intrinsic property of smoke.As the pressure of smoke changes with mass of certain power,a kind of linear wave equation for smoke can be derived from the conservation equation... Wave motion in subway or tunnel fire is an intrinsic property of smoke.As the pressure of smoke changes with mass of certain power,a kind of linear wave equation for smoke can be derived from the conservation equations of its mass and momentum,under nearly homogeneous zone assumption.The smoke movement of 4 subway fires was simulated with Airpak.By fitting the pressure-mass functions to the simulated data,wave equations of the smoke were derived,and wave motions of smoke were thus validated.It can be seen that smoke wave is a kind of mass wave,whose velocity is inversely proportional to smoke mass,and wave of a bigger fire propagates slower. 展开更多
关键词 subway fire environment smoke movement wave propagation
下载PDF
An improved social force model (ISFM)-based crowd evacuation simulation method in virtual reality with a subway fire as a case study 被引量:2
2
作者 Jinbin Zhang Jun Zhu +6 位作者 Pei Dang Jianlin Wu Yuxuan Zhou Weilian Li Lin Fu Yukun Guo Jigang You 《International Journal of Digital Earth》 SCIE EI 2023年第1期1186-1204,共19页
Crowd evacuation simulation using virtual reality(VR)is significant for digital emergency response construction.However,existing evacuation simulation studies suffer from poor adaptation to complex environments,ineffi... Crowd evacuation simulation using virtual reality(VR)is significant for digital emergency response construction.However,existing evacuation simulation studies suffer from poor adaptation to complex environments,inefficient evacuations,and poor simulation effects and do not fully consider the impacts of specific disaster environments on crowd evacuation.To more realistically express the crowd evacuation results obtained under the influence offire environments and the subjective consciousness of pedestrians in subway stations,we designed a dynamic pedestrian evacuation path planning method under multiple constraints,analysed the influences of an‘environmental role’and a‘subjective initiative’on crowd evacuation,established an improved social force model(ISFM)-based crowd evacuation simulation method in VR,developed a prototype system and conducted experimental analyses.The experimental results show that the crowd evacuation time of the ISFM is affected by the disaster severity.In simulation experiments without disaster scenarios,the improved model’s crowd evacuation efficiency improved by averages of 12.53%and 15.37%over the commercial Pathfinder software and the original social force model,respectively.The method described herein can effectively support real-time VR crowd evacuation simulation under multiexit and multifloor conditions and can provide technical support for emergency evacuation learning and management decision analyses involving subwayfires. 展开更多
关键词 subway stationfire improved social force model crowd evacuation simulation virtual reality path planning
原文传递
Assessment of the Influence of Tunnel Settlement on Operational Performance of Subway Vehicles
3
作者 Gang Niu Guangwei Zhang +2 位作者 Zhaoyang Jin Wei Zhang Xiang Liu 《Structural Durability & Health Monitoring》 EI 2024年第1期55-71,共17页
In the realm of subway shield tunnel operations,the impact of tunnel settlement on the operational performance of subway vehicles is a crucial concern.This study introduces an advanced analytical model to investigate ... In the realm of subway shield tunnel operations,the impact of tunnel settlement on the operational performance of subway vehicles is a crucial concern.This study introduces an advanced analytical model to investigate rail geometric deformations caused by settlement within a vehicle-track-tunnel coupled system.The model integrates the geometric deformations of the track,attributed to settlement,as track irregularities.A novel“cyclic model”algorithm was employed to enhance computational efficiency without compromising on precision,a claim that was rigorously validated.The model’s capability extends to analyzing the time-history responses of vehicles traversing settlement-affected areas.The research primarily focuses on how settlement wavelength,amplitude,and vehicle speed influence operational performance.Key findings indicate that an increase in settlement wavelength can improve vehicle performance,whereas a rise in amplitude can degrade it.The study also establishes settlement thresholds,based on vehicle operation comfort and safety.These insights are pivotal for maintaining and enhancing the safety and efficiency of subway systems,providing a valuable framework for urban infrastructure management and long-term maintenance strategies in metropolitan transit systems. 展开更多
关键词 SETTLEMENT running performance subway tunnel dynamic analysis track irregularity THRESHOLD
下载PDF
Automatic Sensing and Detection for Subway Tunnel Pathologies
4
作者 Xingyu Wang Zhengkun Zhu 《Journal of World Architecture》 2024年第1期54-62,共9页
Subway tunnels often suffer from surface pathologies such as cracks,corrosion,fractures,peeling,water and sand infiltration,and sudden hazards caused by foreign object intrusions.Installing a mobile visual pathology s... Subway tunnels often suffer from surface pathologies such as cracks,corrosion,fractures,peeling,water and sand infiltration,and sudden hazards caused by foreign object intrusions.Installing a mobile visual pathology sensing system at the front end of operating trains is a critical measure to ensure subway safety.Taking leakage as the typical pathology,a tunnel pathology automatic visual detection method based on Deeplabv3+(ASTPDS)was proposed to achieve automatic and high-precision detection and pixel-level morphology extraction of pathologies.Compared with similar methods,this approach showed significant advantages and achieved a detection accuracy of 93.12%,surpassing FCN and U-Net.Moreover,it also exceeded the recall rates for detecting leaks of FCN and U-Net by 8.33%and 8.19%,respectively. 展开更多
关键词 Visual detection Neural network Health monitoring Image segmentation Water leakage subway tunnel.
下载PDF
Sustainable Urban Mobility: (A)Synchrony between Subway Systems
5
作者 Ana Paula Borba Gonçalves Barros 《Journal of Traffic and Transportation Engineering》 2024年第3期151-161,共11页
The present study analyses the differences between the subways systems of two cities, Lisbon (Portugal) and Brasília (Brazil), verifying the extent to which their subway systems are spatially integrated with the ... The present study analyses the differences between the subways systems of two cities, Lisbon (Portugal) and Brasília (Brazil), verifying the extent to which their subway systems are spatially integrated with the respective urban fabric-which would promote a better synchrony in terms of economy and sustainability. For interpreting the data, the methodology and tools of the Theory of the Social Logic of Space were used, by means of axial maps, researching the relationship between the constructed and empty (public spaces) areas of the urban structures. Based on the findings, meaningful differences between the subway systems and the configuration of urban spaces were observed, as a product of specific design matrixes. In Lisbon, the mobility associated to the subway seems to be encouraged by the integration of the system with the potential for movement provided by the urban tissue (making the secondary centralities articulated with the subway stations more dynamic). In Brasilia, however, there are several difficulties for such mobility, due to the predominant role of the empty spaces in the city which weakens the gathering potential of such areas, despite the fact that such articulation with secondary centralities is also present there. 展开更多
关键词 Urban mobility spatial configuration space syntax subway system.
下载PDF
Discussion on Construction Technology of Subway Tunnel Expansion under Bridge Foundation
6
作者 Ruiquan Liu 《Journal of Architectural Research and Development》 2024年第2期37-42,共6页
As the urban populations grow,the number and size of subway construction projects are increasing while also meeting higher construction standards.So,subway construction projects must have a better understanding of con... As the urban populations grow,the number and size of subway construction projects are increasing while also meeting higher construction standards.So,subway construction projects must have a better understanding of construction technology.This article focuses on the construction technology of the subway tunnel expansion under the bridge foundation.By analyzing the engineering characteristics of the bridge foundation and using a project as an example,this article provides a detailed discussion of the construction process of tunnel expansion under a bridge foundation.This article aims to serve as a reference for subway tunnel construction in China to ensure the key points of construction technology are understood,thus improving construction quality and laying a solid technical foundation for the sustainable development of urban rail engineering. 展开更多
关键词 subway tunnel Bridge foundation underpass expansion Construction technology Steel truss support construction
下载PDF
Construction Technology of Pile Foundation for Subway Tunnel Crossing Bridge
7
作者 Ruiquan Liu 《Journal of World Architecture》 2024年第2期37-42,共6页
Urban infrastructure has become more complex with the rapid development of urban transportation networks.In urban environments with limited space,construction of facilities like subways and bridges may mutually influe... Urban infrastructure has become more complex with the rapid development of urban transportation networks.In urban environments with limited space,construction of facilities like subways and bridges may mutually influence each other,especially when subway construction requires passing under bridges.In such cases,pile foundation replacement technology is often necessary.However,this technology is highly specialized,with a lengthy and risky construction period,and high costs.Personnel must be proficient in key technical aspects to ensure construction quality.This article discusses the technical principle,construction process,and core technology of pile foundation replacement,along with the application of this technology in subway tunnel crossing bridge projects,supported by engineering examples for reference. 展开更多
关键词 subway tunnel Bridge pile foundation Replacement construction
下载PDF
Pedestrian evacuation at the subway station under fire 被引量:2
8
作者 杨晓霞 董海荣 +1 位作者 姚秀明 孙绪彬 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第4期486-494,共9页
With the development of urban rail transit, ensuring the safe evacuation of pedestrians at subway stations has become an important issue in the case of an emergency such as a fire. This paper chooses the platform of l... With the development of urban rail transit, ensuring the safe evacuation of pedestrians at subway stations has become an important issue in the case of an emergency such as a fire. This paper chooses the platform of line 4 at the Beijing Xu- anwumen subway station to study the emergency evacuation process under fire. Based on the established platform, effects of the fire dynamics, different initial pedestrian densities, and positions of fire on evacuation are investigated. According to simulation results, it is found that the fire increases the air temperature and the smoke density, and decreases pedestrians'- visibility and walking velocity. Also, there is a critical initial density at the platform if achieving a safe evacuation within the required 6 minutes. Furthermore, different positions of fire set in this paper have little difference on crowd evacuation if the fire is not large enough. The suggestions provided in this paper are helpful for the subway operators to prevent major casualties. 展开更多
关键词 pedestrian evacuation FDS Evac subway station fire social force model
下载PDF
Functional Characteristics of Beijing Subway Stations Based on POI Data:Taking Beijing Metro Line 6 as An Example 被引量:1
9
作者 SUN Shuai LIU Ting AI Jie 《Journal of Landscape Research》 2023年第3期27-30,共4页
Urban subway station is a key node related to urban social,political,economic and cultural activities.There are some differences in the location,function orientation,land use and flow characteristics of different type... Urban subway station is a key node related to urban social,political,economic and cultural activities.There are some differences in the location,function orientation,land use and flow characteristics of different types of stations in the city.This paper mainly used Tyson’s edge,kernel density analysis,chart analysis and other methods to classify the functional types of 412,393 POI data of 26 stations along Metro he results showed that the spatial distribution of Beijing Metro Line 6 was mainly divided into 3 categories,subway stations were divided into 4 categories.Among them,type A sites were divided into composite and single types,and the distribution characteristics of the 6 types of sites were quite different.Based on the qualitative and quantitative analysis of POI point data,this method can quickly classify and analyze the characteristics of stations along Line 6 in Beijing,which also has theoretical and practical value for the planning of urban subway lines. 展开更多
关键词 Urban functional areas subway station POI data
下载PDF
Monitoring Study of Long-Term Land Subsidence during Subway Operation in High-Density Urban Areas Based on DInSAR-GPS-GIS Technology and Numerical Simulation
10
作者 Yu Song Xuejun Chen +4 位作者 Baoping Zou Jundong Mu Rusheng Hu Siqi Cheng Shengli Zhao 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第2期1021-1039,共19页
During subway operation,various factors will cause long-term land subsidence,such as the vibration subsidence of foundation soil caused by train vibration load,incomplete consolidation deformation of foundation soil d... During subway operation,various factors will cause long-term land subsidence,such as the vibration subsidence of foundation soil caused by train vibration load,incomplete consolidation deformation of foundation soil during tunnel construction,dense buildings and structures in the vicinity of the tunnel,and changes in water level in the stratum where the tunnel is located.The monitoring of long-term land subsidence during subway operation in high-density urban areas differs from that in low-density urban construction areas.The former is the gathering point of the entire urban population.There are many complex buildings around the project,busy road traffic,high pedestrian flow,and less vegetation cover.Several existing items requiremonitoring.However,monitoring distance is long,and providing early warning is difficult.This study uses the 2.8 km operation line between Wulin Square station and Ding’an Road station of Hangzhou Subway Line 1 as an example to propose the integrated method of DInSAR-GPS-GIS technology and the key algorithm for long-term land subsidence deformation.Then,it selects multiscene image data to analyze long-termland subsidence of high-density urban areas during subway operation.Results show that long-term land subsidence caused by the operation of Wulin Square station to Ding’an Road station of Hangzhou Subway Line 1 is small,with maximumsubsidence of 30.64 mm,and minimumsubsidence of 11.45 mm,and average subsidence ranging from 19.27 to 21.33 mm.And FLAC3D software was used to verify the monitoring situation,using the geological conditions of the soil in the study area and the tunnel profile to simulate the settlement under vehicle load,and the simulation results tended to be consistent with the monitoring situation. 展开更多
关键词 Long-term land subsidence subway operation DInSAR-GPS-GIS technology high-density urban areas urban subway numerical simulation
下载PDF
A practical framework for performance-based reliability analysis of subway stations based on a faultestructure combined system
11
作者 M.Ghorbanzadeh M.Hajihassani M.Kharghani 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2023年第6期1406-1425,共20页
It is necessary to pay particular attention to the uncertainties that exist in an engineering problem to reduce the risk of seismic damage of infrastructures against natural hazards.Moreover,certain structural perform... It is necessary to pay particular attention to the uncertainties that exist in an engineering problem to reduce the risk of seismic damage of infrastructures against natural hazards.Moreover,certain structural performance levels should be satisfied during strong earthquakes.However,these performance levels have been only well described for aboveground structures.This study investigates the main uncertainties involved in the performance-based seismic analysis of a multi-story subway station.More than 100 pulse-like and no pulse-like ground motions have been selected.In this regard,an effective framework is presented,based on a set of nonlinear static and dynamic analyses performed by OpenSees code.The probabilistic seismic demand models for computing the free-field shear strain of soil and racking ratio of structure are proposed.These models result in less variability compared with existing relations,and make it possible to evaluate a wider range of uncertainties through reliability analysis in Rtx software using the Monte Carlo sampling method.This work is performed for three different structural performance levels(denoted as PL1ePL3).It is demonstrated that the error terms related to the magnitude and location of earthquake excitations and also the corresponding attenuation relationships have been the most important parameters.Therefore,using a faultestructure model would be inevitable for the reliability analysis of subway stations.It is found that the higher performance level(i.e.PL3)has more sensitivity to random variables than the others.In this condition,the pulse-like ground motions have a major contribution to the vulnerability of subway stations. 展开更多
关键词 Seismic hazard Probabilistic models Reliability analysis subway station
下载PDF
Calculation of CO Behavior in the Platform for Deeply Underground Subway Station with Different Fire Strengths
12
作者 Yong-Jun Jang Ji-Min Ryu +2 位作者 Jong-Ki Kim Min-Chul Chun Dong-Hoe Koo 《Journal of Energy and Power Engineering》 2016年第3期199-205,共7页
Effect of different fire strengths on the smoke distribution in the subway station is investigated. Shin-Gum-Ho station (line #5) in Seoui is selected as a case study for variation of CO (carbon monoxide) distribu... Effect of different fire strengths on the smoke distribution in the subway station is investigated. Shin-Gum-Ho station (line #5) in Seoui is selected as a case study for variation of CO (carbon monoxide) distribution caused by the fire in the platform. The ventilation in the station is set to be an air supply mod in the lobby and an air exhaustion mod in the platform. One-side main tunnel ventilation (7,000 m3/min) is applied to operate in the tunnel. The fire is assumed to break out in the middle of train parked in the platform tunnel. Two kinds of fire strength are used. One is 10 MW and the other is 20 MW. Ventilation diffusers in the station are modeled as 317 square shapes & four rectangular shapes in the lobby and platform. The total of 7.5 million grids is generated and whole domain is divided to 22 blocks for parallel computation. Large eddy simulation method is applied to solve the momentum equation. The behavior of CO is calculated according to different fire strengths and compared with each other. 展开更多
关键词 Carbon monoxide subway station fire strength main tunnel ventilation LES.
下载PDF
An experimental study on fire characteristics of urban complex underground space based on BIM
13
作者 Jinrong Cui Hao Mei +3 位作者 Haosen Sun Ye Jingqi Wei Hu Yong Xu 《CAAI Transactions on Intelligence Technology》 SCIE EI 2023年第4期1403-1414,共12页
Compared with the space on the ground,if there is a fire in the urban complex underground space,the loss will be greatly harmful.In addition,the complex underground space is usually connected with other large space ar... Compared with the space on the ground,if there is a fire in the urban complex underground space,the loss will be greatly harmful.In addition,the complex underground space is usually connected with other large space areas and densely populated.Once a fire occurs in the complex underground space,it will cause huge property losses and casualties.In order to reduce the risk of fire,it is necessary to deeply understand the development rules and characteristics of fire in the complex underground space of the city.This article has mainly carried on the following work:(I)A particularly complex model of the multi‐storey subway station was built.On this basis,three groups of comparative experiments were conducted to study the effects of fire power,fire location and smoke control system on fire development,and the conclusion that fire location is the most important factor for fire development was obtained;(II)In order to explore the entire space fire and the local space fire,CFD(Computational Fluid Dynamics)is used to build a large‐size fire model and a small‐size fire model respectively;(III)Multiple detector data as temperature slices were built,and it is expected to make full use of the simulation data to deduce the important index of fire location in the early stage of fire.All of the works in this paper will provide reference experimental data for the prevention and firefighting of a sudden fire in the complex underground space. 展开更多
关键词 fire simulation underground multi‐storey subway station urban complex underground space
下载PDF
Classification of Beijing Line 10 Subway Living Circle Based on Multi-source Big Data
14
作者 SUN Shuai LI Ziying 《Journal of Landscape Research》 2023年第3期53-58,共6页
In the first-tier cities,subway has become an important carrier and life focus of people’s daily travel activities.By studying the distribution of POIs of public service facilities around Metro Line 10,using GIS to q... In the first-tier cities,subway has become an important carrier and life focus of people’s daily travel activities.By studying the distribution of POIs of public service facilities around Metro Line 10,using GIS to quantitatively analyze the surrounding formats of subway stations,discussing the functional attributes of subway stations,and discussing the distribution of urban functions from a new perspective,this paper provided guidance and advice for the construction of service facilities. 展开更多
关键词 Multi-source big data subway living circle BEIJING GIS
下载PDF
Passengers gathering-scattering analysis at the corners of subway stations
15
作者 Jie Xu Yihan Shi Hui Zhang 《Digital Transportation and Safety》 2023年第2期139-149,共11页
During both daily operation and emergency evacuation,the corners of walking facilities in subway stations play an important role in efficient circulation.However,the effectiveness of the corner is difficult to assess.... During both daily operation and emergency evacuation,the corners of walking facilities in subway stations play an important role in efficient circulation.However,the effectiveness of the corner is difficult to assess.In this paper,a method of passenger gathering and scattering analysis based on queueing models was proposed to investigate the corner performance in subway stations.Firstly,we constructed a set of state spaces of passenger flow according to passenger density and proposed the state transition model of passenger flow.Moreover,the model of passenger flow blocking and unblocking probability were also presented.Then,to illustrate the validity of the method and model,several passenger gathering-scattering scenarios and were simulated to verify the influence of passenger distribution and facility width on passenger walking,and the blocking probability,throughput,and expected time were also analyzed under various widths of the target corridor and arrival rates.Results showed that the proposed model can reproduce the trend of walking parameters changing and the self-organizing phenomenon of'faster is lower'.With the increase of arrival rates of passengers,walking speeds of passengers decrease and the expected walking time is prolonged,and the blocking probability sharply increased when the arrival rate exceeded 7 peds/s.In addition,with change of width of the target facility,efficiency of capacity of walking circulation facility fluctuated.With the width of the target corridor enlarged by 10%,the steady state of passenger flow was less crowded.Therefore,corridor width is critical to the circulation efficiency of passengers in subway stations.The conclusions will help to develop reasonable passenger flow control plans to ease the jam and keep passengers walking safely. 展开更多
关键词 subway station CORNER Gathering-scattering behavior Queueing model Transition probability model
下载PDF
Study on the Principle Model and Simplification of Subway Station Itemized Energy Consumption
16
作者 Baoping Zeng Yonggang Li +1 位作者 Wanglong Jia Hengbo Luo 《Journal of World Architecture》 2023年第1期1-6,共6页
Owing to the constant modernization and urbanization of China,most cities have subways,and the total power consumption of subway stations has been rising,which contradicts with China’s green goals.In this regard,ener... Owing to the constant modernization and urbanization of China,most cities have subways,and the total power consumption of subway stations has been rising,which contradicts with China’s green goals.In this regard,energy consumption indicators for major energy use projects in subway stations should be established,comprehensive evaluation and detailed research on the current situation of subway operation should be conducted,and specific energy-saving measures should be taken from a diversified perspective.It is crucial to systematically sort out the principle of sub-item energy consumption in subway stations,and practice and explore the specific simplification measures of the principle model of sub-item energy consumption,so as to lay a solid foundation for achieving the goal of reducing energy consumption of subway stations. 展开更多
关键词 subway station Itemized energy consumption Principle model Simplified approach
下载PDF
Assessment of the Safety Impacts of a Pit Construction on the Neighboring Subway
17
作者 Song Gao 《Journal of Architectural Research and Development》 2023年第5期34-40,共7页
In order to study the impact of pit excavation on the adjacent existing subway structure,the safety impact assessment of a project was carried out using project under construction near the subway as the engineering ba... In order to study the impact of pit excavation on the adjacent existing subway structure,the safety impact assessment of a project was carried out using project under construction near the subway as the engineering background.The results show that the new pit construction will produce some additional deformation on the existing subway interval structure,the deformation values are within the permissible range for safe operation.Through analysis of the results,the risk point rating of the pit adjacent to the interval is level 2.In general,the impacts of the pit construction on the neighboring subway structure are less than the specification limits. 展开更多
关键词 Pit excavation Safety assessment Adjacent to existing subway
下载PDF
Simulation of fire emergency evacuation in a large-passenger-flow subway station based on the on-site measured data of Shenzhen Metro
18
作者 Hua Chen Chenyang Zhang +3 位作者 Jieyu Zhang Ya Shu Xinjian Qi Chaozhe Jiang 《Transportation Safety and Environment》 EI 2024年第1期47-55,共9页
Because of its large capacity,high efficiency and energy savings,the subway has gradually become the primary mode of transportation for citizens.A high density of passengers exists within a large-passenger-flow subway... Because of its large capacity,high efficiency and energy savings,the subway has gradually become the primary mode of transportation for citizens.A high density of passengers exists within a large-passenger-flow subway station,and the number of casualties and injuries during a fire emergency is substantial.In this paper,Pathfinder software and on-site measured data of Pingzhou station in Shenzhen(China)were utilized to simulate a fire emergency evacuation in a large-passenger-flow subway station.The Required Safe Egress Time(RSET),number of passengers and flow rates of stairs and escalators were analysed for three fire evacuation scenarios:train fire,platform fire and hall fire.The evacuation time of the train fire,which was 1173 s,was the longest,and 3621 occupants needed to evacuate when the train was fully loaded.Occupants could not complete the evacuation within 6 mins in all three fire evacuation scenarios,which does not meet the current standard requirements and codes.By changing the number of passengers and the number of stairs for evacuation,the flow rate capacity and evacuation time were explored,which have reference values for safety management and emergency evacuation plan optimization during peak hours of subway operation. 展开更多
关键词 fire emergency evacuation large-passenger-flow subway station on-site measured data PATHFINDER
原文传递
Numerical and Experimental Study on Ventilation Panel Models in a Subway Passenger Compartment 被引量:13
19
作者 Yu Tao Mingzhi Yang +2 位作者 Bosen Qian Fan Wu Tiantian Wang 《Engineering》 SCIE EI 2019年第2期329-336,共8页
The internal flow field study of car compartments is an important step in railroad vehicle design and optimization. The flow field profile has a significant impact on the temperature distribution and passenger comfort... The internal flow field study of car compartments is an important step in railroad vehicle design and optimization. The flow field profile has a significant impact on the temperature distribution and passenger comfort level. Experimental studies on flow field can yield accurate results but carry a high time and computational cost. In contrast, the numerical simulation method can yield an internal flow field profile in less time than an experimental study. This study aims to improve the computational efficiency of numerical simulation by adapting two simplified models—the porous media model and the porous jump face model—to study the internal flow field of a railroad car compartment. The results provided by both simplified models are compared with the original numerical simulation model and with experimental data. Based on the results, the porous media model has a better agreement with the original model and with the experimental results. The flow field parameters (temperature and velocity) of the porous media model have relatively small numerical errors, with a maximum numerical error of 4.7%. The difference between the numerical results of the original model and those of the porous media model is less than 1%. By replacing the original numerical simulation model with the porous media model, the flow field of subway car compartments can be calculated with a reduction of about 25% in computing resources, while maintaining good accuracy. 展开更多
关键词 NUMERICAL SIMULATION EXPERIMENT Ventilation PANEL MODEL subway
下载PDF
Using the Haddon matrix to explore medical response strategies for terrorist subway bombings 被引量:7
20
作者 Tie-Cheng Yan Min Yu 《Military Medical Research》 SCIE CAS CSCD 2019年第4期320-327,共8页
Background:Since the 1970 s,terrorist bombings in subways have been frequently occurring worldwide.To cope with this threat and to provide medical response countermeasures,we analyzed the characteristics of subway bom... Background:Since the 1970 s,terrorist bombings in subways have been frequently occurring worldwide.To cope with this threat and to provide medical response countermeasures,we analyzed the characteristics of subway bombing terrorist attacks and used the Haddon matrix to explore medical response strategies.Methods:First,we analyzed 111 subway bombings from 1970 to 2017 recorded in the Global Terrorism Database to provide a reference for the strategy exploration.Then,we convened an expert panel to use the Haddon matrix to explore the medical response strategies to subway bombings.Results:In recent decades,at least one bombing attack occurs every 3 years.Summarized by the Haddon matrix,the influencing factors of medical responses to conventional subway bombings include the adequacy of first-aid kits and the medical evacuation equipment,the traffic conditions affecting the evacuation,the continuity and stability of communication,as well as the factors exclusively attributed to dirty bomb attacks in subways,such as ionizing radiation protection capabilities,the structure of the radiation sickness treatment network based on the subway lines,and the disposal of radioactive sewage.These factors form the basis of the strategy discussion.Conclusions:Since subway bombings are long-term threats,it is necessary to have proper medical response preparation.Based on the Haddon matrix,we explored the medical response strategies for terrorist subway bombings,especially dirty bomb attacks.Haddon matrix can help policymakers systematically find the most important factors,which makes the preparations of the response more efficient. 展开更多
关键词 Haddon MATRIX subway Terrorism Bomb attack MEDICAL RESPONSE
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部