Electrochemical techniques were applied to study the crevice corrosion resistance of two types of stainless steel alloys namely, conventional 316L and 6% Mo super austenitic in acidified 3% NaCl solution at room tempe...Electrochemical techniques were applied to study the crevice corrosion resistance of two types of stainless steel alloys namely, conventional 316L and 6% Mo super austenitic in acidified 3% NaCl solution at room temperature.Potentiodynamic results showed that 6% Mo alloy possessed a remarkable resistance to crevice corrosion compared with 316L alloy when they are tested in the same solution. The breakdown potential at which passivity broke down for 316L alloy was 0.00 mV (SCE). The corresponding value for 6% Mo alloy could not reach up to the potential value of 700 mV (SCE). 316L alloy suffered extremely from crevice corrosion at room temperature (about 25℃), which indicates that the critical crevice corrosion temperature, below which crevice corrosion does not occur, was lower than the test temperature. For 6% Mo alloy, the critical crevice corrosion temperature was higher than the testing temperature. Electrochemical parameters indicated that 6% Mo alloy exhibited higher crevice corrosion resistance than 316L alloy.展开更多
In order to discuss the buckling stability of super-long rock-socketed filling piles widely used in bridge engineering in soft soil area such as Dongting Lake, the second stability type was adopted instead of traditio...In order to discuss the buckling stability of super-long rock-socketed filling piles widely used in bridge engineering in soft soil area such as Dongting Lake, the second stability type was adopted instead of traditional first type, and a newly invented numerical analysis method, i.e. the element-free Galerkin method (EFGM), was introduced to consider the non-concordant deformation and nonlinearity of the pile-soil interface. Then, based on the nonlinear elastic-ideal plastic pile-soil interface model, a nonlinear iterative algorithm was given to analyze the pile-soil interaction, and a program for buckling analysis of piles by the EFGM (PBAP-EFGM) and arc length method was worked out as well. The application results in an engineering example show that, the shape of pile top load-settlement curve obtained by the program agrees well with the measured one, of which the difference may be caused mainly by those uncertain factors such as possible initial defects of pile shaft and the eccentric loading during the test process. However, the calculated critical load is very close with the measured ultimate load of the test pile, and the corresponding relative error is only 5.6%, far better than the calculated values by linear and nonlinear incremental buckling analysis (with a greater relative error of 37.0% and 15.4% respectively), which also verifies the rationality and feasibility of the present method.展开更多
The reliability of a network is an important indicator for maintaining communication and ensuring its stable operation. Therefore, the assessment of reliability in underlying interconnection networks has become an inc...The reliability of a network is an important indicator for maintaining communication and ensuring its stable operation. Therefore, the assessment of reliability in underlying interconnection networks has become an increasingly important research issue. However, at present, the reliability assessment of many interconnected networks is not yet accurate,which inevitably weakens their fault tolerance and diagnostic capabilities. To improve network reliability,researchers have proposed various methods and strategies for precise assessment. This paper introduces a novel family of interconnection networks called general matching composed networks(gMCNs), which is based on the common characteristics of network topology structure. After analyzing the topological properties of gMCNs, we establish a relationship between super connectivity and conditional diagnosability of gMCNs. Furthermore, we assess the reliability of g MCNs, and determine the conditional diagnosability of many interconnection networks.展开更多
电力系统运行在非理想状态时,容易产生短暂的电压波动,此时并联有源电力滤波器(shunt active power filter,SAPF)采用无源控制策略无法高效、精确地调节电能质量,而常规滑模控制又容易引起抖振。针对上述情况,将无源控制和抗干扰能力更...电力系统运行在非理想状态时,容易产生短暂的电压波动,此时并联有源电力滤波器(shunt active power filter,SAPF)采用无源控制策略无法高效、精确地调节电能质量,而常规滑模控制又容易引起抖振。针对上述情况,将无源控制和抗干扰能力更强的超螺旋二阶滑模控制相结合,提出了一种无源超螺旋二阶滑模控制策略。首先,根据有源电力滤波器的数学模型建立基于正负序分离的欧拉−拉格朗日模型;其次,对系统的模型进行了无源性分析,且根据其无源性设计了无源控制器,同时采用超螺旋二阶滑模控制对无源控制器进一步优化,提高了系统整体的鲁棒性和抗干扰能力;最后,在理想状态和负载突变、负载不平衡、电网电压不平衡、单相电压突变4种非理想状态下,通过仿真实验验证了无源超螺旋二阶滑模控制策略的有效性和优越性。展开更多
文摘Electrochemical techniques were applied to study the crevice corrosion resistance of two types of stainless steel alloys namely, conventional 316L and 6% Mo super austenitic in acidified 3% NaCl solution at room temperature.Potentiodynamic results showed that 6% Mo alloy possessed a remarkable resistance to crevice corrosion compared with 316L alloy when they are tested in the same solution. The breakdown potential at which passivity broke down for 316L alloy was 0.00 mV (SCE). The corresponding value for 6% Mo alloy could not reach up to the potential value of 700 mV (SCE). 316L alloy suffered extremely from crevice corrosion at room temperature (about 25℃), which indicates that the critical crevice corrosion temperature, below which crevice corrosion does not occur, was lower than the test temperature. For 6% Mo alloy, the critical crevice corrosion temperature was higher than the testing temperature. Electrochemical parameters indicated that 6% Mo alloy exhibited higher crevice corrosion resistance than 316L alloy.
基金Project(50378036) supported by the National Natural Science Foundation of China
文摘In order to discuss the buckling stability of super-long rock-socketed filling piles widely used in bridge engineering in soft soil area such as Dongting Lake, the second stability type was adopted instead of traditional first type, and a newly invented numerical analysis method, i.e. the element-free Galerkin method (EFGM), was introduced to consider the non-concordant deformation and nonlinearity of the pile-soil interface. Then, based on the nonlinear elastic-ideal plastic pile-soil interface model, a nonlinear iterative algorithm was given to analyze the pile-soil interaction, and a program for buckling analysis of piles by the EFGM (PBAP-EFGM) and arc length method was worked out as well. The application results in an engineering example show that, the shape of pile top load-settlement curve obtained by the program agrees well with the measured one, of which the difference may be caused mainly by those uncertain factors such as possible initial defects of pile shaft and the eccentric loading during the test process. However, the calculated critical load is very close with the measured ultimate load of the test pile, and the corresponding relative error is only 5.6%, far better than the calculated values by linear and nonlinear incremental buckling analysis (with a greater relative error of 37.0% and 15.4% respectively), which also verifies the rationality and feasibility of the present method.
基金supported by National Natural Science Foundation of China (No.62362005)。
文摘The reliability of a network is an important indicator for maintaining communication and ensuring its stable operation. Therefore, the assessment of reliability in underlying interconnection networks has become an increasingly important research issue. However, at present, the reliability assessment of many interconnected networks is not yet accurate,which inevitably weakens their fault tolerance and diagnostic capabilities. To improve network reliability,researchers have proposed various methods and strategies for precise assessment. This paper introduces a novel family of interconnection networks called general matching composed networks(gMCNs), which is based on the common characteristics of network topology structure. After analyzing the topological properties of gMCNs, we establish a relationship between super connectivity and conditional diagnosability of gMCNs. Furthermore, we assess the reliability of g MCNs, and determine the conditional diagnosability of many interconnection networks.
文摘电力系统运行在非理想状态时,容易产生短暂的电压波动,此时并联有源电力滤波器(shunt active power filter,SAPF)采用无源控制策略无法高效、精确地调节电能质量,而常规滑模控制又容易引起抖振。针对上述情况,将无源控制和抗干扰能力更强的超螺旋二阶滑模控制相结合,提出了一种无源超螺旋二阶滑模控制策略。首先,根据有源电力滤波器的数学模型建立基于正负序分离的欧拉−拉格朗日模型;其次,对系统的模型进行了无源性分析,且根据其无源性设计了无源控制器,同时采用超螺旋二阶滑模控制对无源控制器进一步优化,提高了系统整体的鲁棒性和抗干扰能力;最后,在理想状态和负载突变、负载不平衡、电网电压不平衡、单相电压突变4种非理想状态下,通过仿真实验验证了无源超螺旋二阶滑模控制策略的有效性和优越性。