Conserving the architectural structures of heritage buildings has become an important issue in Beirut. It is the result of necessary retrofit of existing traditional bourgeoisie architecture of 19th century, belonging...Conserving the architectural structures of heritage buildings has become an important issue in Beirut. It is the result of necessary retrofit of existing traditional bourgeoisie architecture of 19th century, belonging to the late Ottoman period, recognizing the importance of its traditional technics and to keep them in use. Although, they have been subjected to lack of maintenance and repair which led to processes of severe degradation, compromising their use, it allows now a deep observation of their characteristics. The main goal of this article is: to outline the evolution of the construction of this late Ottoman Heritage;characterize its architectural typology;understand the impact of Building Codes;and present results of surveys. For the analysis, non-destructive methods were performed. The survey of three case studies according to a pre-selection of representative Ottoman buildings (1840-1940) is presented. This intends to contribute for the conservation of Beirut traditional housing and give useful technical information.展开更多
Building defect is an issue in existing buildings that needs urgent tackling to prevent further problems. This study assessed the defects in concrete elements in residential buildings of 30 years and above in the Onit...Building defect is an issue in existing buildings that needs urgent tackling to prevent further problems. This study assessed the defects in concrete elements in residential buildings of 30 years and above in the Onitsha metropolis of Anambra State, Nigeria. Data collection instruments in the study include structured questionnaire, interviews, visual inspection/observations, archival records, recordings, photographs;and non-destructive testing of the concrete elements in an existing building in the study area. The population of this study constituted of the construction registered professionals and the existing buildings in study area. The sample for the study was based on the calculated sample size using Taro Yamani Formula. A total of 158 registered professionals were sampled from the population of 260. The questionnaires were purposively distributed to the registered professionals up to the required sample sizes of 158 and 129 questionnaires were properly filled and returned. The study used the SPSS and Microsoft Excel to analyze the data. The results were analyzed in percentages and figures using descriptive statistics and presented in the form of pie charts and tables. The finding of the study revealed that the causes and effects of structural defects on the concrete elements in existing buildings in the study area according to the rating are;exposed/corrosion of the embedded metals, faulty workmanship, overload and impacts, chemical attack, freeze-thaw deterioration, fire/heat, restraint to volume change. The visual observation revealed that the structural elements are characterized by heavy defects such as deep vertical, horizontal and diagonal cracks, exposed/ corrosion of the embedded metals, spalling of the concrete slabs. The existence of defects in the concrete members led to the low compressive strength of the concrete elements and the structural instability of the existing buildings as revealed by the non-destructive test. The non-destructive test result revealed that most of the tested concrete elements have low compressive strength value and such were remarked poor as they did not satisfy the assumed value. Essentially, the study concluded by recommending that regular monitoring, inspections and non-destructive testing of concrete elements should be conducted on existing aged and defected buildings to detect the structural stability of the buildings;and it is imperative to evacuate occupants from heavy structurally deteriorated and defected buildings since most of them have lost their residual design life span and ability to sustain imposed loads.展开更多
High-rise reinforced concrete buildings are in great demand in developing countries with rapid urbanization. Construction engineers are facing more and more safety control challenges. One major issue is the understand...High-rise reinforced concrete buildings are in great demand in developing countries with rapid urbanization. Construction engineers are facing more and more safety control challenges. One major issue is the understanding of the load distributions, especially the maximum slab load, of structures under construction, which is time dependent. Previous methods were mainly targeted to specific examples, providing specific solutions without addressing the fundamental issues of finding general solutions for load distributions in reinforced concrete buildings with different geometrical and material characteristics during construction. The concept of a structural characteristic parameter is used here to parametedze the main geometrical and material characteristics of concrete structures for generalized assessments of load distributions during construction. The maximum slab load for 20 different construction shoring/reshoring schemes is presented. The results indicate that the traditional simplified method may underestimate or overestimate the maximum slab load, depending mainly on the shoring/reshoring schemes. The structural characteristic parameter approach was specifically developed to assist construction engineers to estimate load distributions to assure safe construction procedures.展开更多
文摘Conserving the architectural structures of heritage buildings has become an important issue in Beirut. It is the result of necessary retrofit of existing traditional bourgeoisie architecture of 19th century, belonging to the late Ottoman period, recognizing the importance of its traditional technics and to keep them in use. Although, they have been subjected to lack of maintenance and repair which led to processes of severe degradation, compromising their use, it allows now a deep observation of their characteristics. The main goal of this article is: to outline the evolution of the construction of this late Ottoman Heritage;characterize its architectural typology;understand the impact of Building Codes;and present results of surveys. For the analysis, non-destructive methods were performed. The survey of three case studies according to a pre-selection of representative Ottoman buildings (1840-1940) is presented. This intends to contribute for the conservation of Beirut traditional housing and give useful technical information.
文摘Building defect is an issue in existing buildings that needs urgent tackling to prevent further problems. This study assessed the defects in concrete elements in residential buildings of 30 years and above in the Onitsha metropolis of Anambra State, Nigeria. Data collection instruments in the study include structured questionnaire, interviews, visual inspection/observations, archival records, recordings, photographs;and non-destructive testing of the concrete elements in an existing building in the study area. The population of this study constituted of the construction registered professionals and the existing buildings in study area. The sample for the study was based on the calculated sample size using Taro Yamani Formula. A total of 158 registered professionals were sampled from the population of 260. The questionnaires were purposively distributed to the registered professionals up to the required sample sizes of 158 and 129 questionnaires were properly filled and returned. The study used the SPSS and Microsoft Excel to analyze the data. The results were analyzed in percentages and figures using descriptive statistics and presented in the form of pie charts and tables. The finding of the study revealed that the causes and effects of structural defects on the concrete elements in existing buildings in the study area according to the rating are;exposed/corrosion of the embedded metals, faulty workmanship, overload and impacts, chemical attack, freeze-thaw deterioration, fire/heat, restraint to volume change. The visual observation revealed that the structural elements are characterized by heavy defects such as deep vertical, horizontal and diagonal cracks, exposed/ corrosion of the embedded metals, spalling of the concrete slabs. The existence of defects in the concrete members led to the low compressive strength of the concrete elements and the structural instability of the existing buildings as revealed by the non-destructive test. The non-destructive test result revealed that most of the tested concrete elements have low compressive strength value and such were remarked poor as they did not satisfy the assumed value. Essentially, the study concluded by recommending that regular monitoring, inspections and non-destructive testing of concrete elements should be conducted on existing aged and defected buildings to detect the structural stability of the buildings;and it is imperative to evacuate occupants from heavy structurally deteriorated and defected buildings since most of them have lost their residual design life span and ability to sustain imposed loads.
基金Supported by the National Natural Science Foundation of China (Nos.50378051,70172005,and 70572007)the National Science and Technology Planning Project (No.2006BAJ01B04-03)
文摘High-rise reinforced concrete buildings are in great demand in developing countries with rapid urbanization. Construction engineers are facing more and more safety control challenges. One major issue is the understanding of the load distributions, especially the maximum slab load, of structures under construction, which is time dependent. Previous methods were mainly targeted to specific examples, providing specific solutions without addressing the fundamental issues of finding general solutions for load distributions in reinforced concrete buildings with different geometrical and material characteristics during construction. The concept of a structural characteristic parameter is used here to parametedze the main geometrical and material characteristics of concrete structures for generalized assessments of load distributions during construction. The maximum slab load for 20 different construction shoring/reshoring schemes is presented. The results indicate that the traditional simplified method may underestimate or overestimate the maximum slab load, depending mainly on the shoring/reshoring schemes. The structural characteristic parameter approach was specifically developed to assist construction engineers to estimate load distributions to assure safe construction procedures.