Two 650 MHz single-cell superconducting radio-frequency(SRF)cavities used for the Circular Electron Positron Collider(CEPC)were studied to achieve a high accelerating gradient(E_(acc))and high intrinsic quality factor...Two 650 MHz single-cell superconducting radio-frequency(SRF)cavities used for the Circular Electron Positron Collider(CEPC)were studied to achieve a high accelerating gradient(E_(acc))and high intrinsic quality factor(Q_(0)).The 650 MHz single-cell cavities were subjected to a combination of buffered chemical polishing(BCP)and electropolishing(EP),and their E_(acc) exceeded40 MV/m.Such a high E_(acc) may result from the cold EP with more uniform removal.BCP is easy,cheap,and rough,whereas EP is complicated,expensive,and precise Therefore,the combination of BCP and EP investigated in this study is suitable for surface treatments of mass SRF cavities.Medium temperature(mid-T)furnace baking was also conducted,which demonstrated an ultrahigh Q_(0) of 8×10^(10) at 22 MV/m for both cavities,and an extremely low BCS resistance(R_(BCS))of~1.0 nΩwas achieved a2.0 K.展开更多
RF superconducting (SRF) cavities can work in continuous wave mode or long pulse mode. SRF technology has been developing rapidly since the end of the last century. RF superconducting technology is widely used in pa...RF superconducting (SRF) cavities can work in continuous wave mode or long pulse mode. SRF technology has been developing rapidly since the end of the last century. RF superconducting technology is widely used in particle accelerators around the world. As the key elements, research on superconducting cavities is carried out worldwide. Besides Europe, the United States and Japan, many countries have already started SRF projects, such as Canada, India, Korea, etc. Great improvements on SRF technology have been made in China in recent years. Progress in SRF cavities is introduced in this paper.展开更多
The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),follow...The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),followed by nitrogen doping.A"2/6"condition is adopted,similar to that for 1.3 GHz cavities of Linear Coherent Light Source II.The quality factor of both cavities improved to 7×10^(10)in low fields,i.e.,higher than that obtained from the baseline test.One 650 MHz two-cell cavity is nitrogen infused at 165℃for 48 h with a BCP surface base.The intrinsic quality factor(Q0)reached6×10^(10)at 22 MV/m in the vertical test,and the maximum gradient is 25 MV/m,which exceeds the specification of the CEPC(4×10^(10)at 22 MV/m).展开更多
Researches on large grain superconducting cavities are carried out at SRF laboratory of Peking University. A 1.3GHz TESLA type single cell cavity and a 1.3GHz 2-cell cavity made of large grain niobium were fabricated ...Researches on large grain superconducting cavities are carried out at SRF laboratory of Peking University. A 1.3GHz TESLA type single cell cavity and a 1.3GHz 2-cell cavity made of large grain niobium were fabricated by Peking University.With the collaboration of Jlab,the measured Eacc of the single-cell cavity reached 43.5MV/m after BCP,baking and high temperature heat treatment.展开更多
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDB25000000)the National Natural Science Foundation of China(No.12075270)the Platform of Advanced Photon Source Technology R&D。
文摘Two 650 MHz single-cell superconducting radio-frequency(SRF)cavities used for the Circular Electron Positron Collider(CEPC)were studied to achieve a high accelerating gradient(E_(acc))and high intrinsic quality factor(Q_(0)).The 650 MHz single-cell cavities were subjected to a combination of buffered chemical polishing(BCP)and electropolishing(EP),and their E_(acc) exceeded40 MV/m.Such a high E_(acc) may result from the cold EP with more uniform removal.BCP is easy,cheap,and rough,whereas EP is complicated,expensive,and precise Therefore,the combination of BCP and EP investigated in this study is suitable for surface treatments of mass SRF cavities.Medium temperature(mid-T)furnace baking was also conducted,which demonstrated an ultrahigh Q_(0) of 8×10^(10) at 22 MV/m for both cavities,and an extremely low BCS resistance(R_(BCS))of~1.0 nΩwas achieved a2.0 K.
基金Supported by Major State Basic Research Development Program (2002CB713600, 2008CB817706)
文摘RF superconducting (SRF) cavities can work in continuous wave mode or long pulse mode. SRF technology has been developing rapidly since the end of the last century. RF superconducting technology is widely used in particle accelerators around the world. As the key elements, research on superconducting cavities is carried out worldwide. Besides Europe, the United States and Japan, many countries have already started SRF projects, such as Canada, India, Korea, etc. Great improvements on SRF technology have been made in China in recent years. Progress in SRF cavities is introduced in this paper.
基金supported by the National Key Program for S&T Research and Development(No.2016YFA0400400)the Platform of Advanced Photon Source Technology R&D,National Natural Science Foundation of China(No.11505197).
文摘The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),followed by nitrogen doping.A"2/6"condition is adopted,similar to that for 1.3 GHz cavities of Linear Coherent Light Source II.The quality factor of both cavities improved to 7×10^(10)in low fields,i.e.,higher than that obtained from the baseline test.One 650 MHz two-cell cavity is nitrogen infused at 165℃for 48 h with a BCP surface base.The intrinsic quality factor(Q0)reached6×10^(10)at 22 MV/m in the vertical test,and the maximum gradient is 25 MV/m,which exceeds the specification of the CEPC(4×10^(10)at 22 MV/m).
文摘Researches on large grain superconducting cavities are carried out at SRF laboratory of Peking University. A 1.3GHz TESLA type single cell cavity and a 1.3GHz 2-cell cavity made of large grain niobium were fabricated by Peking University.With the collaboration of Jlab,the measured Eacc of the single-cell cavity reached 43.5MV/m after BCP,baking and high temperature heat treatment.