期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
New Development of VPI Process for Large Superconducting Coils
1
作者 潘皖江 武松涛 崔益民 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第4期1877-1880,共4页
High vacuum is required for Vacuum Pressure Impregnation (VPI) process of large coils used in cryogenic. The defects such as dry spots and over rich resins should be minimized in large superconducting coils used. Both... High vacuum is required for Vacuum Pressure Impregnation (VPI) process of large coils used in cryogenic. The defects such as dry spots and over rich resins should be minimized in large superconducting coils used. Both sealing problems associated with the mold and over rich resin problems are eliminated by using vacuum bag mold method with which we can simplify the design of vacuum mold. 展开更多
关键词 superconducting coils vacuum pressure impregnation vacuum bag method
下载PDF
Calculation of AC Losses of CICC for Superconducting Outsert Coils in a Hybrid Magnet
2
作者 何鹏 陈灼民 +4 位作者 陈文革 谭运飞 潘引年 王福堂 匡光力 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第5期636-640,共5页
This paper is devoted to predict AC loss of cable in conduit conductor (CICC) which is of importance in the design of conductors. The consideration for the conductor's design and main parameters for the magnets are... This paper is devoted to predict AC loss of cable in conduit conductor (CICC) which is of importance in the design of conductors. The consideration for the conductor's design and main parameters for the magnets are introduced. In order to attain a good accuracy in the calculation of AC losses, the field distribution within superconducting outsert should be considered. Calculation of the AC losses, including hysteresis losses and coupling losses, is conducted. An emphasis is put on the hysteresis loss during the ramp up of the current to the operational current (15.3 kA) and the coupling loss of the conductor in a power-down condition for insert. The results are obtained to be 74.9 kJ and 950 J for 40 T hybrid magnets, respectively. Based on the calculation, a brief analysis of losses effect on the conductor design and the operation of magnet is given for the purpose that the capacity of the cryogenertor can be evaluated and the stability regime can be improved in our future work on the hybrid magnets. 展开更多
关键词 AC losses coupling losses HYSTERESIS superconducting outsert coils
下载PDF
Transient multi-physics behavior of an insert high temperature superconducting no-insulation coil in hybrid superconducting magnets with inductive coupling
3
作者 Xiang KANG Yujin TONG +1 位作者 Wei WU Xingzhe WANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2023年第2期255-272,共18页
A transient multi-physics model incorporated with an electromagneto-thermomechanical coupling is developed to capture the multi-field behavior of a single-pancake(SP)insert no-insulation(NI)coil in a hybrid magnet dur... A transient multi-physics model incorporated with an electromagneto-thermomechanical coupling is developed to capture the multi-field behavior of a single-pancake(SP)insert no-insulation(NI)coil in a hybrid magnet during the charging and discharging processes.The coupled problem is resolved by means of the finite element method(FEM)for the magneto-thermo-elastic behaviors and the Runge-Kutta method for the transient responses of the electrical circuits of the hybrid superconducting magnet system.The results reveal that the transient multi-physics responses of the insert NI coil primarily depend on the charging/discharging procedure of the hybrid magnet.Moreover,a reverse azimuthal current and a compressive hoop stress are induced in the insert NI coil during the charging process,while a forward azimuthal current and a tensile hoop stress are observed during the discharging process.The induced voltages in the insert NI coil can drive the currents flowing across the radial turns where the contact resistance exists.Therefore,it brings forth significant Joule heat,causing a temperature rise and a uniform distribution of this heat in the coil turns.Accordingly,a thermally/mechanically unstable or quenching event may be encountered when a high operating current is flowing in the insert NI coil.It is numerically predicted that a quick charging will induce a compressive hoop stress which may bring a risk of buckling instability in the coil,while a discharging will not.The simulations provide an insight of hybrid superconducting magnets under transient start-up or shutdown phases which are inevitably encountered in practical applications. 展开更多
关键词 hybrid superconducting magnet high temperature superconducting(HTS)no-insulation(NI)coil inductive coupling multi-physics field thermal stability
下载PDF
Proton linac-based therapy facility for ultra-high dose rate (FLASH) treatment 被引量:4
4
作者 Wen-Cheng Fang Xiao-Xia Huang +10 位作者 Jian-Hao Tan Chao-Peng Wang Cheng-Cheng Xiao Yi-Xing Lu Yu Zhang Yu-Qing Yang Yi-Ming Xu Han-Yu Gong Jun-Qiang Zhang Shao-Peng Zhong Zhen-Tang Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第4期1-9,共9页
As an advanced treatment method in the past five years,ultra-high dose rate(FLASH)radiotherapy as a breakthrough and milestone in radiotherapy development has been verified to be much less harmful to healthy tissues i... As an advanced treatment method in the past five years,ultra-high dose rate(FLASH)radiotherapy as a breakthrough and milestone in radiotherapy development has been verified to be much less harmful to healthy tissues in different experiments.FLASH treatments require an instantaneous dose rate as high as hundreds of grays per second to complete the treatment in less than 100 ms.Current proton therapy facilities with the spread-out of the Bragg peak formed by different energy layers,to our knowledge,cannot easily achieve an adequate dose rate for FLASH treatments because the energy layer switch or gantry rotation of current facilities requires a few seconds,which is relatively long.A new design for a therapy facility based on a proton linear accelerator(linac)for FLASH treatment is proposed herein.It is designed under two criteria:no mechanical motion and no magnetic field variation.The new therapy facility can achieve an ultrahigh dose rate of up to 300 Gy/s;however,it delivers an instantaneous dose of 30 Gy within 100 ms to complete a typical FLASH treatment.The design includes a compact proton linac with permanent magnets,a fast beam kicker in both azimuth and elevation angles,a fixed gantry with a static superconducting coil to steer proton bunches with all energy,a fast beam scanner using radio-frequency(RF)deflectors,and a fast low-level RF system.All relevant principles and conceptual proposals are presented herein. 展开更多
关键词 Proton therapy FLASH Proton linac DEFLECTOR superconducting coil Fast scanner
下载PDF
Strain Measurement on the Toroidal Field (TF) Coil Cases 被引量:1
5
作者 陈灼民 龙风 吴浩 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第2期2734-2736,共3页
The stress-strain state of the structure is a matter of interest to designer. The strain measurement of superconducting magnets at cryogenic temperature is a specific technique. Based on strain measurement of TF coil ... The stress-strain state of the structure is a matter of interest to designer. The strain measurement of superconducting magnets at cryogenic temperature is a specific technique. Based on strain measurement of TF coil case for EAST, this paper presents a measuring technique at cryogenic temperature and on intense magnetic field. The compensation methods for both temperature and magnetic field effects of the gauges, together with the measured results are involved, and the discussions of the measured results are given in the paper. 展开更多
关键词 superconducting coil strain measurement COMPENSATION
下载PDF
Ramping loss and mechanical response in a no-insulation high-temperature superconducting layer-wound coil and intra-layers no-insulation coil 被引量:1
6
作者 LI DongKe LIU DongHui YONG HuaDong 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2022年第1期115-130,共16页
The layer-wound coil has a great potential in nuclear magnetic resonance and magnetic resonance imaging owing to the better spatial homogeneity of the magnetic field.However,high-temperature superconducting(HTS)coil w... The layer-wound coil has a great potential in nuclear magnetic resonance and magnetic resonance imaging owing to the better spatial homogeneity of the magnetic field.However,high-temperature superconducting(HTS)coil wound by no-insulation(NI)layer-wound technique has been verified with a long field delay time.A new method named the intra-layer no-insulation(LNI)winding technique has been proposed to reduce the charging delay time of the coil.This paper is mainly to study and compare the ramping loss and mechanical characteristics of the layer-wound coil and LNI coil.The results indicate that the total ramping loss can be significantly reduced by using the LNI winding method.The effects of the ramping rate of power supply current and the contact resistivity on the ramping loss are also discussed in the paper.Furthermore,the stress distributions in the layer-wound coil and LNI coil are compared,where the cooling process and Lorentz force are both considered.It can be found that the copper sheet of the LNI coil experiences relatively higher stress than its(RE)Ba;Cu;O;(REBCO)conductor layer.Meanwhile,the magnitude of stress generated in the REBCO conductor of the LNI coil is slightly different from that of the layer-wound coil. 展开更多
关键词 high-temperature superconducting coil ramping loss stress
原文传递
上一页 1 下一页 到第