The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),follow...The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),followed by nitrogen doping.A"2/6"condition is adopted,similar to that for 1.3 GHz cavities of Linear Coherent Light Source II.The quality factor of both cavities improved to 7×10^(10)in low fields,i.e.,higher than that obtained from the baseline test.One 650 MHz two-cell cavity is nitrogen infused at 165℃for 48 h with a BCP surface base.The intrinsic quality factor(Q0)reached6×10^(10)at 22 MV/m in the vertical test,and the maximum gradient is 25 MV/m,which exceeds the specification of the CEPC(4×10^(10)at 22 MV/m).展开更多
A third harmonic superconducting niobium cavity has been proposed for installation in the Shanghai Synchrotron Radiation Facility (SSRF) storage ring to improve the Touschek lifetime. In order to investigate the fea...A third harmonic superconducting niobium cavity has been proposed for installation in the Shanghai Synchrotron Radiation Facility (SSRF) storage ring to improve the Touschek lifetime. In order to investigate the feasibility of the superconducting cavity fabrication indigenously and the possibility to master the fabrica tion techniques, cavities were fabricated from copper and niobium sheets by deep drawing and electron-beam welding, and a series of measurements, such as resonant frequency, shape dimensions and wall thickness, were carried out during this process. After analysis of various problems existing in the fabrication process, technique improvements were proposed, and finally the precise shape as designed and resonant frequency within 1.2 MHz were achieved for the new completed cavities. In addition, full annealing was finally proved to be a good cure for niobium sheets' tearing up during deep drawing. By fabricating niobium cavities successfully, some problems to the next step were cleared. This paper introduces the process of cavity fabrication and its technique improvements towards forming, and the initial vertical test result of niobium cavity is also presented.展开更多
The Superconducting Radio Frequency (SRF) system of the upgrade project of the Beijing Electron Positron Collider (BEPCII) has been in operation for almost 8 years. During operation, many problems have been encoun...The Superconducting Radio Frequency (SRF) system of the upgrade project of the Beijing Electron Positron Collider (BEPCII) has been in operation for almost 8 years. During operation, many problems have been encountered, such as excessive heating of the power couplers, frequent beam trips during high intensity colliding, false arc interlock trigger and so on. Among them, some has been solved successfully, some have been alleviated. This paper will describe some experiences with BEPCII SRF system operation, including the symptoms, causes and solutions of problems.展开更多
基金supported by the National Key Program for S&T Research and Development(No.2016YFA0400400)the Platform of Advanced Photon Source Technology R&D,National Natural Science Foundation of China(No.11505197).
文摘The nitrogen doping/infusion of 650 MHz cavities for the circular electron positron collider(CEPC)is investigated in this study.Two 650 MHz 1-cell cavities are first treated via buffered chemical polishing(BCP),followed by nitrogen doping.A"2/6"condition is adopted,similar to that for 1.3 GHz cavities of Linear Coherent Light Source II.The quality factor of both cavities improved to 7×10^(10)in low fields,i.e.,higher than that obtained from the baseline test.One 650 MHz two-cell cavity is nitrogen infused at 165℃for 48 h with a BCP surface base.The intrinsic quality factor(Q0)reached6×10^(10)at 22 MV/m in the vertical test,and the maximum gradient is 25 MV/m,which exceeds the specification of the CEPC(4×10^(10)at 22 MV/m).
基金Supported by Science and Technology Commission of Shanghai Municipality (026505027, 036505011)
文摘A third harmonic superconducting niobium cavity has been proposed for installation in the Shanghai Synchrotron Radiation Facility (SSRF) storage ring to improve the Touschek lifetime. In order to investigate the feasibility of the superconducting cavity fabrication indigenously and the possibility to master the fabrica tion techniques, cavities were fabricated from copper and niobium sheets by deep drawing and electron-beam welding, and a series of measurements, such as resonant frequency, shape dimensions and wall thickness, were carried out during this process. After analysis of various problems existing in the fabrication process, technique improvements were proposed, and finally the precise shape as designed and resonant frequency within 1.2 MHz were achieved for the new completed cavities. In addition, full annealing was finally proved to be a good cure for niobium sheets' tearing up during deep drawing. By fabricating niobium cavities successfully, some problems to the next step were cleared. This paper introduces the process of cavity fabrication and its technique improvements towards forming, and the initial vertical test result of niobium cavity is also presented.
文摘The Superconducting Radio Frequency (SRF) system of the upgrade project of the Beijing Electron Positron Collider (BEPCII) has been in operation for almost 8 years. During operation, many problems have been encountered, such as excessive heating of the power couplers, frequent beam trips during high intensity colliding, false arc interlock trigger and so on. Among them, some has been solved successfully, some have been alleviated. This paper will describe some experiences with BEPCII SRF system operation, including the symptoms, causes and solutions of problems.