In this paper the development status and background of 350-MW China-made supercritical steam turbines are introduced.Through the study on the eight turbines that are put into operation,their technical performances are...In this paper the development status and background of 350-MW China-made supercritical steam turbines are introduced.Through the study on the eight turbines that are put into operation,their technical performances are compared and summarized.The major factors affecting the heat consumption rate are analyzed in details and the technical measures to reduce the heat consumption rate are put forward.These measures have been applied to several such units with significant improvements,which can provide important references for the maintenance and retrofit of 350-MW super critical steam turbines.展开更多
As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introd...As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introduces a new design of for steam feeding the water pump of an air-cooled unit using the back-pressure steam turbine as the prime motor. Using variable condition analysis on a 600 MW direct air-cooled unit, and with consideration of the effect on the ambient conditions, the feasibility, economy, and adaptability of the design are verified.展开更多
文摘In this paper the development status and background of 350-MW China-made supercritical steam turbines are introduced.Through the study on the eight turbines that are put into operation,their technical performances are compared and summarized.The major factors affecting the heat consumption rate are analyzed in details and the technical measures to reduce the heat consumption rate are put forward.These measures have been applied to several such units with significant improvements,which can provide important references for the maintenance and retrofit of 350-MW super critical steam turbines.
文摘As the performance of an air-cooled condenser is apt to be affected by the fluctuating ambient condition, some difficulties are brought to the use of a steam feeding water pump in an air-cooled unit. This paper introduces a new design of for steam feeding the water pump of an air-cooled unit using the back-pressure steam turbine as the prime motor. Using variable condition analysis on a 600 MW direct air-cooled unit, and with consideration of the effect on the ambient conditions, the feasibility, economy, and adaptability of the design are verified.