期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
A novel cascaded H-bridge photovoltaic inverter with flexible arc suppression function
1
作者 Junyi Tang Wei Gao 《Global Energy Interconnection》 EI CSCD 2024年第4期513-527,共15页
This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elim... This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations. 展开更多
关键词 Photovoltaic inverter Flexible arc suppression Adaptive control Fuzzy neural network Sliding mode control Exit strategy
下载PDF
Control method based on DRFNN sliding mode for multifunctional flexible multistate switch 被引量:1
2
作者 Jianghua Liao Wei Gao +1 位作者 Yan Yang Gengjie Yang 《Global Energy Interconnection》 EI CSCD 2024年第2期190-205,共16页
To address the low accuracy and stability when applying classical control theory in distribution networks with distributed generation,a control method involving flexible multistate switches(FMSs)is proposed in this st... To address the low accuracy and stability when applying classical control theory in distribution networks with distributed generation,a control method involving flexible multistate switches(FMSs)is proposed in this study.This approach is based on an improved double-loop recursive fuzzy neural network(DRFNN)sliding mode,which is intended to stably achieve multiterminal power interaction and adaptive arc suppression for single-phase ground faults.First,an improved DRFNN sliding mode control(SMC)method is proposed to overcome the chattering and transient overshoot inherent in the classical SMC and reduce the reliance on a precise mathematical model of the control system.To improve the robustness of the system,an adaptive parameter-adjustment strategy for the DRFNN is designed,where its dynamic mapping capabilities are leveraged to improve the transient compensation control.Additionally,a quasi-continuous second-order sliding mode controller with a calculus-driven sliding mode surface is developed to improve the current monitoring accuracy and enhance the system stability.The stability of the proposed method and the convergence of the network parameters are verified using the Lyapunov theorem.A simulation model of the three-port FMS with its control system is constructed in MATLAB/Simulink.The simulation result confirms the feasibility and effectiveness of the proposed control strategy based on a comparative analysis. 展开更多
关键词 Distribution networks Flexible multistate switch Grounding fault arc suppression Double-loop recursive fuzzy neural network Quasi-continuous second-order sliding mode
下载PDF
Comparison between open phase fault of arc suppression coil and single phase to earth fault in coal mine distribution network 被引量:3
3
作者 LI Xiao-bo WANG Chong-lin 《Journal of China University of Mining and Technology》 EI 2008年第3期368-372,共5页
When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and ... When, in a coal mine distribution network whose neutral point is grounded by an arc suppression coil (ASC), a fault occurs in the ASC, compensation cannot be properly realized. Furthermore, it can damage the safe and reliable run of the network. We first introduce a three-phase five-column arc suppression coil (TPFCASC) and discuss its autotracking compensation theory. Then we compare the single phase to ground fault of the coal mine distribution network with an open phase fault at the TPFCASC using the Thévenin theory, the symmetrical-component method and the complex sequence network respectively. The results show that, in both types of faults, zero-sequence voltage of the network will appear and the maximum magnitude of this zero-sequence voltage is different in both faults. Based on this situation, a protection for the open phase fault at the TPFCASC should be estab-lished. 展开更多
关键词 open phase PROTECTION single phase to ground fault three-phase five-column arc suppression coil (TPFCASC)
下载PDF
Application of DC component to select fault branch in arc suppression coil grounding system 被引量:2
4
作者 Zhi-Jie WANG Yan-Wen WANG 《Journal of Coal Science & Engineering(China)》 2013年第3期396-401,共6页
When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is... When single phase earth fault occurs in the arc suppression coil grounding system, the amplitude of the transient capacitance current is high and decays fast, but the attenuation of the transient inductance current is much slower. This paper analyses the DC component of fault branch, and has found it is much bigger than that of the normal branches in transient state. All the simulation results obtained from three compensation types, different fault time and different wave cycles show that the DC component of fault branch is much higher than that of those normal branches. These results verify the effectiveness of taking the DC component as the method of fault line selection in the arc suppression coil grounding system. 展开更多
关键词 DC component arc suppression coil fault line selection transient state
下载PDF
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
5
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation Grounding current detection Zero sequence voltage detection
下载PDF
An optimization method for passive muzzle arc control devices in augmented railguns
6
作者 Bo Tang Qing-hua Lin Bao-ming Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第2期271-279,共9页
In this paper,a passive muzzle arc control device(PMACD)of the augmented railguns is studied.By discussing its performance at different numbers of extra rails,a parameter optimization model is proposed.Through the cal... In this paper,a passive muzzle arc control device(PMACD)of the augmented railguns is studied.By discussing its performance at different numbers of extra rails,a parameter optimization model is proposed.Through the calculation model,it is found that the PMACD works well in the simple railgun,which refers to the gun that there is only one pair of rails in the inner bore.The PMACD may decrease the simple railgun’s armature peak current and muzzle arc,but affect its muzzle velocity not much.However,in the augmented railguns it has different characteristics.If the parameters of the PMACD are not selected suitable.It may increase the armature peak current and muzzle arc,but greatly decrease the velocity.The reason for this problem is that the extra rails generate a strong magnetic field in front of the armature,which induces a large current to change the armature current.It is also found that when the resistance and inductance parameters of the PMACD satisfy with the optimization formula,the PMACD can also play a good role in arc suppression in the augmented railguns.Experiments of an augmented railgun with a stainless steel PMACD are carried out to verify this optimization method.Results show that the muzzle arc is obviously controlled.This work may provide a reference for the design of the muzzle arc control device. 展开更多
关键词 Augmented railguns Arc suppression Muzzle device Optimization method SHUNTS
下载PDF
A new design of foam spray nozzle used for precise dust control in underground coal mines 被引量:4
7
作者 Han Fangwei Wang Deming +1 位作者 Jiang Jiaxing Zhu Xiaolong 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2016年第2期241-246,共6页
In order to improve the utilization rate of foam,an arc jet nozzle was designed for precise dust control.Through theoretical analysis,the different demands of foam were compared amongst arc jets,flat jets and full con... In order to improve the utilization rate of foam,an arc jet nozzle was designed for precise dust control.Through theoretical analysis,the different demands of foam were compared amongst arc jets,flat jets and full cone jets when the dust source was covered identically by foam.It is proved that foam consumption was least when an arc jet was used.Foam production capability of an arc jet nozzle under different conditions was investigated through experiments.The results show that with the gas liquid ratio(GLR)increasing,the spray state of an arc jet nozzle presents successively water jet,foam jet and mist.Under a reasonable working condition range of foam production and a fixed GLR,foam production quantity increases at first,and then decreases with the increase of liquid supply quantity.When the inner diameter of the nozzle is 14 mm,the best GLR is 30 and the optimum liquid supply quantity is0.375 m^3/h.The results of field experiments show that the total dust and respirable dust suppression efficiency of arc jet nozzles is 85.8%and 82.6%respectively,which are 1.39 and 1.37 times higher than the full cone nozzles and 1.20 and 1.19 times higher than the fiat nozzles. 展开更多
关键词 Dust control Precise spray Arc jet Gas liquid ratio(GLR) Dust suppression efficiency
下载PDF
Simulation and experimental research on methods to suppress ferroresonance in potential transformers 被引量:2
8
作者 Hongwen Liu Ke Wang +2 位作者 Junhui Zhao Hao Li Shijin Tian 《Journal of Control and Decision》 EI 2018年第2期195-208,共14页
Ferroresonance in distribution networks is usually hard to be identified and predicted because it is nonlinear and dependent on multiple factors and conditions.This study discusses different common antiferroresonance... Ferroresonance in distribution networks is usually hard to be identified and predicted because it is nonlinear and dependent on multiple factors and conditions.This study discusses different common antiferroresonance methods by numerical simulations and experimental tests.In order to study the reliability of the anti-ferroresonance measures,a 10 kV ferroresonance testing system was setup.Then a number of simulations and experiments were carried out to show the ferroresonance phenomena initiated by single-phase grounding faults and/or single-phase disconnection faults.In addition,potential transformer models with the characteristic of non-linear magnetic excitation were developed and used in PSCAD-based simulation studies.These studies investigated the performance of primary resonance eliminators and arc suppression coils on restraining the ferroresonance under multiple power system parameters and initialisations.In addition,a joint anti-ferroresonance method is proposed and verified.The simulation and experimental studies can provide guidelines for evaluating the anti-ferroresonance methods in distribution networks. 展开更多
关键词 Arc suppression coil distribution network FERRORESONANCE primary resonance eliminator PSCAD/EMTDC
原文传递
上一页 1 下一页 到第