期刊文献+
共找到424篇文章
< 1 2 22 >
每页显示 20 50 100
Fiber cladding dual channel surface plasmon resonance sensor based on S-type fiber 被引量:1
1
作者 魏勇 赵晓玲 +6 位作者 刘春兰 王锐 蒋天赐 李玲玲 石晨 刘纯彪 竺栋 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期187-195,共9页
Fiber cladding surface plasmon resonance(SPR)sensors have few structures,and a clad SPR sensor based on S-type fiber is proposed in this paper.This new type of fiber cladding SPR sensor was formed by electrofusing an ... Fiber cladding surface plasmon resonance(SPR)sensors have few structures,and a clad SPR sensor based on S-type fiber is proposed in this paper.This new type of fiber cladding SPR sensor was formed by electrofusing an S-shaped structure on the fiber to couple the light in the fiber core to the cladding.In this paper,the effects of fiber parameters on the performance of the sensor were studied by simulation and experiment.Based on the conclusion that the smaller the core diameter is,the closer the working band of the SPR resonance is to long wavelengths,and that the geometric characteristics mean that a multimode fiber can receive the fiber cladding light from a small core diameter few-mode fiber,a dual channel SPR sensor with a double S-type fiber cascade was proposed.In the refractive index detection range of 1.333–1.385refractive index units(RIU),the resonant working band of channel I is 627.66 nm–759.78 nm,with an average sensitivity of 2540.77 nm/RIU,and the resonant working band of channel II is 518.24 nm–658.2 nm,with an average sensitivity of2691.54 nm/RIU.The processing method for the S-type fiber cladding SPR sensor is simple,effectively solving the problem of this type of SPR sensor structure and the difficult realization of a dual channel.The sensor is expected to be used in the fields of medical treatment and biological analysis. 展开更多
关键词 surface plasmon resonance(spr) S-type structure dual channel cladding fiber spr sensor
下载PDF
Dual-channel fiber-optic surface plasmon resonance sensor with cascaded coaxial dual-waveguide D-type structure and microsphere structure 被引量:1
2
作者 李玲玲 魏勇 +4 位作者 刘春兰 任卓 周爱 刘志海 张羽 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期201-208,共8页
To address the restriction of fiber-optic surface plasmon resonance(SPR) sensors in the field of multi-sample detection, a novel dual-channel fiber-optic SPR sensor based on the cascade of coaxial dual-waveguide D-typ... To address the restriction of fiber-optic surface plasmon resonance(SPR) sensors in the field of multi-sample detection, a novel dual-channel fiber-optic SPR sensor based on the cascade of coaxial dual-waveguide D-type structure and microsphere structure is proposed in this paper. The fiber sidepolishing technique converts the coaxial dual-waveguide fiber into a D-type one, and the evanescent wave in the ring core leaks, generating a D-type sensing region;the fiber optic fused ball push technology converts the coaxial dual waveguides into microspheres, and the stimulated cladding mode evanescent wave leaks, producing the microsphere sensing region. By injecting light into the coaxial dual-waveguide middle core alone, the sensor can realize single-stage sensing in the microsphere sensing area;it can also realize dual-channel sensing in the D-type sensing area and microsphere sensing area by injecting light into the ring core. The refractive index measurement ranges for the two channels are 1.333–1.365 and 1.375–1.405, respectively, with detection sensitivities of 981.56 nm/RIU and 4138 nm/RIU. The sensor combines wavelength division multiplexing and space division multiplexing technologies, presenting a novel research concept for multi-channel fiber SPR sensors. 展开更多
关键词 coaxial dual-waveguide optical fiber D structure optical fiber microsphere structure dual-channel fiber-optic surface plasmon resonance(spr)sensor
下载PDF
Surface Plasmon Resonance for C-Reactive Protein Detection in Human Plasma
3
作者 Hanen Chammem Imen Hafaid +3 位作者 Olivier Meilhac Farid Menaa Laurence Mora Adnane Abdelghani 《Journal of Biomaterials and Nanobiotechnology》 2014年第3期153-158,共6页
In this work, we describe an approach of detecting biomarkers by Surface Plasmon Resonance imaging (SPRi) technique in real samples. Two C-Reactive Protein (CRP)-antibody immobilization methods were used: The first me... In this work, we describe an approach of detecting biomarkers by Surface Plasmon Resonance imaging (SPRi) technique in real samples. Two C-Reactive Protein (CRP)-antibody immobilization methods were used: The first method was based on direct physisorption of CRP-antibody onto gold surface;the second one was based on oriented CRP-antibody with protein G intermediate layer. The two developed immunosensors were tested against CRP antigen in phosphate buffer saline solution with the SPRi technique. The response of the developed immunosensors was reproducible and stable. The detection limit of 10 pg&#183mL&#451 and 50 pg&#183mL&#451 CRP-antigen was observed with and without protein G respectively with this technique. Moreover, the developed SPRi immunosensor was used for CRP-antigen detection in human plasma. A detection limit of 5 ng&#183mL&#451 and 10 ng&#183mL&#451 was obtained with and without protein G respectively. These obtained results were compared to those obtained with QCM (Quartz Crystal Microbalance) and Enzyme-Linked Immunosorbent Assay (ELISA) techniques. 展开更多
关键词 C-Reactive PROTEIN PROTEIN G surface PLASMON resonance IMAGING Human plasma
下载PDF
Analysis of 17β-Estadiol from Sewage in Coastal Marine Environment by Surface Plasmon Resonance Technique 被引量:6
4
作者 ZHANG Wei-wei CHEN Yu-chun +2 位作者 LUO Zhao-feng WANG Ju-ying MA De-yi 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2007年第4期404-407,共4页
In this study, surface plasmon resonance (SPR) for monitoring 17β-eatradiol (E2) was developed. The small molecule E2 was immobilized on a CM5 sensor chip for an indirect competitive immunoassay to detect E2. The... In this study, surface plasmon resonance (SPR) for monitoring 17β-eatradiol (E2) was developed. The small molecule E2 was immobilized on a CM5 sensor chip for an indirect competitive immunoassay to detect E2. The SPR response bahed on the antigen-antibody reaction was measured by injecting the sample solution into the flow system. The limitation of detection was 0.445 μg/L. The developed SPE-SPR system was applied to analyze the seawater samples. Recovery of E2 was 91.6%-93. 1%. Relative standard deviations(RSD) for the E2 assay were between 10.9%-15.1% (n = 3). The range of determination of E2 samples from the sewage in the coastal marine environ-ment was between ND(lower than detection limit) and ca. 11.78 ng/L. 展开更多
关键词 surface plasmon resonance (spr 17Β-ESTRADIOL IMMUNOASSAY SPE
下载PDF
Detection of Penicillin via Surface Plasmon Resonance Biosensor 被引量:2
5
作者 ZHANG Ying JIN Wei +7 位作者 YANG Meng-chao ZHANG Ti-qiang ZHOU Chao XIE Fei SONG Qi REN Hao JIN Qin-han MU Ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第5期792-796,共5页
A method of using Au colloid to capture the decomposed product of penicillin, penicillamine, on a surface plasmon resonance(SPR) biosensor for the quantitative determination of penicillin was developed. Based on the... A method of using Au colloid to capture the decomposed product of penicillin, penicillamine, on a surface plasmon resonance(SPR) biosensor for the quantitative determination of penicillin was developed. Based on the de-composition of penicillin to generate penicillamine and penilloaldehyde, a high sensitive biosensor for detecting penicillin was also developed. In our experiment, it was penicillamine rather than penicillin that has been measured. This is because penicillamine contains a functional group that makes it self-assembling on Au colloid to increase the molecular weight so as to improve the surface plasmon resonance signal. On a UV-Vis spectrophotometer, a high concentration of penicilliamine-Au complex was determined, indicating that penicillamine was already well combined with Au colloid. The method, using the combination of Au colloid with penicillamine, proved to detect penicillin. 展开更多
关键词 surface plasmon resonance(spr) BIOSENSOR PENICILLAMINE Au colloid
下载PDF
Advances in Phase Detection Technique of Surface Plasmon Resonance Biosensor 被引量:1
6
作者 Yu Xinglong Wei Xing Deng Yan Liu Fangfang 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期299-304,共6页
Surface plasmon resonance (SPR) sensing is an optical method based on evanescent wave.SPR biosensor can detect interaction of label-free biomolecules in real-time.With further development,it can become a research ins... Surface plasmon resonance (SPR) sensing is an optical method based on evanescent wave.SPR biosensor can detect interaction of label-free biomolecules in real-time.With further development,it can become a research instrument in proteomics.SPR biosensor can be divided intensity measurement and phase measurement,and the latter possesses higher sensitivity than the former one.This paper attempts to summarize the SPR phase detection theory,discuss the major developments,compare the merits and deficiencies of various methods,and look forward to future prospects. 展开更多
关键词 surface plasmon resonance(spr) phase detection ELLIPSOMETRY HETERODYNE INTERFEROMETRY
下载PDF
Characteristics of Surface Plasmon Resonance Imaging lnterferometer
7
作者 Wei Xing Deng Yan Liu Fangfang Yu Xinglong 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期595-599,共5页
In recent life science research,identifying and characterizing entire biomolecular interaction networks is prerequisite to understanding cellular processes on a molecular and biophysical level.A surface plasmon resona... In recent life science research,identifying and characterizing entire biomolecular interaction networks is prerequisite to understanding cellular processes on a molecular and biophysical level.A surface plasmon resonance (SPR) imaging interferometer based on spatial phase modulation detection is presented to meet this demand.In this method,the SPR sensing chip surface is illuminated with collimated parallel light beam,and a Wollaston prism is introduced into the reflected light path to produce the interference of polarized light reflected from SPR sensing chip.Information of biomolecular interactions can be obtained by extracting the phase change from the SPR interference patterns.Using our interferometer,we made experiments on a series concentration of NaCl solutions to investigate its detection range,linearity,sensitivity and resolution.The results indicate that the SPR imaging interferometer is mainly sufficient for biomolecular interaction detection. 展开更多
关键词 surface plasmon resonance(spr) detection range LINEARITY sensitivity RESOLUTION
下载PDF
Particle-in-cell investigation on the resonant absorption of a plasma surface wave
8
作者 蓝朝晖 胡希伟 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第10期319-324,共6页
The resonant absorption of a plasma surface wave is supposed to be an important and efficient mechanism of power deposition for a surface wave plasma source. In this paper, by using the particle-in-cell method and Mon... The resonant absorption of a plasma surface wave is supposed to be an important and efficient mechanism of power deposition for a surface wave plasma source. In this paper, by using the particle-in-cell method and Monte Carlo simulation, the resonance absorption mechanism is investigated. Simulation results demonstrate the existence of surface wave resonance and show the high efficiency of heating electrons. The positions of resonant points, the resonance width and the spatio-temporal evolution of the resonant electric field are presented, which accord well with the theoretical results. The paper also discusses the effect of pressure on the resonance electric field and the plasma density. 展开更多
关键词 particle-in-cell simulation plasma surface wave resonant absorption
下载PDF
Surface plasmon resonance sensor based on molecularly imprinted films for the detection of pentaerythritol tetranitrate (PETN)
9
作者 ZHANG Qing-wen BAO Han +4 位作者 ZHAO Feng-qin BAO Si-miao WEI Tian-xin ZHANG Peng CUI He 《Journal of Beijing Institute of Technology》 EI CAS 2014年第1期126-130,共5页
A novel surface plasmon resonance (SPR) sensor based on molecularly imprinted films (MIFs) was developed for the detection of pentaerythritol tetranitrate (PETN). In this work, the thin MIFs were formed on a gol... A novel surface plasmon resonance (SPR) sensor based on molecularly imprinted films (MIFs) was developed for the detection of pentaerythritol tetranitrate (PETN). In this work, the thin MIFs were formed on a gold sensor chip through thermal co-polymerization of functional mono- mers (methacrylic acid, MAA) and crosslinking monomers (ethylene glycol dimethacrylate, EGD- MA) in the presence of template molecules PETN. The template molecules PETN were subsequently removed from the MIFs simply by rinsing the MIFs with a mixture of acetonitrile and acetic acid 9:1 ( v/v), thus the recognition sites were formed for specific detection of PETN. According to the mass coverage equation, the surface coverage of removed PETN from MIFs was about 10. 8 ng/mm~. The developed SPR sensor allowed for the detection of PETN at concentration down to 10-~~ mol/L. A control experiment utilizing an analogue cyclotrimethylenetrinitramine (RDX) showed MIFs' good selectivity to PETN. 展开更多
关键词 surface plasmon resonance (spr molecularly imprinted films (MIFs) pentaerythritoltetranitrate (PETN)
下载PDF
Improvement of the Specificity of Surface Plasmon Resonance with BSA-modified Chip
10
作者 Li Hua CHEN 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第12期1619-1622,共4页
A chip was modified with bovine serum albumin (BSA), then interaction between glutathione (GSH) immobilized on the top of BSA and glutathione-S-transferase (GST) was examined, using surface plasmon resonance (... A chip was modified with bovine serum albumin (BSA), then interaction between glutathione (GSH) immobilized on the top of BSA and glutathione-S-transferase (GST) was examined, using surface plasmon resonance (SPR). The SPR results showed that BSA-modified chip was effective not only in binding the target proteins but also in suppressing the nonspecific binding (NSB) of proteins. 展开更多
关键词 surface plasmon resonance (spr bovine serum albumin (BSA) glutathione (GSH) glutathione-S-trans ferase (GST).
下载PDF
Development and Application of Time-Resolved Surface Plasmon Resonance Spectrometer
11
作者 Yan Mao Yu Bao +3 位作者 Wei Wang Zhenggang Li Fenghua Li Li Niu 《American Journal of Analytical Chemistry》 2011年第5期589-604,共16页
Surface plasmon resonance (SPR) sensor, an optical sensor exploiting special electromagnetic waves-surface plasmon polaritons to probe interactions between an analyte in solution and a molecular recognition element im... Surface plasmon resonance (SPR) sensor, an optical sensor exploiting special electromagnetic waves-surface plasmon polaritons to probe interactions between an analyte in solution and a molecular recognition element immobilized on the SPR sensor surface, has been widely used in various realms, such as investigating biomolecular interactions and binding properties, detection of biological and chemical analytes, environmental monitoring, food safety and medical diagnostics. This paper reviews the development of SPR sensors and SPR commercial instruments, and emphatically introduces the time-resolved surface plasmon resonance (TR-SPR) techniques. The excellent performances of high sensitivity and rapid detection are easily achieved with TR-SPR spectrometer, whereas the traditional SPR spectrometer cannot be accomplished. Therefore, TR-SPR spectrometer is appropriate for real time analysis of bio-recognition events and small molecular dynamics. However, only two commercial TR-SPR instruments have been exhibited at present, Thermo FT-SPR 100 and Autolab ESPRIT (SPRINGLE). Unfortunately, the high-priced instruments are not suitable for extensive applications in laboratories at present. Herein, a novel commercial TR-SPR spectrometer has been introduced in this review. 展开更多
关键词 surface Alasmon resonance TIME-RESOLVED surface PLASMON resonance spr Sensor TIME-RESOLVED Measurement
下载PDF
基于SPR的重金属离子检测技术研究进展
12
作者 刘小锐 邱娉 +5 位作者 刘倩 陈嘉杰 王雪亮 戴小祺 黄松锋 邵永红 《光学仪器》 2024年第4期1-13,共13页
重金属离子浓度的检测对于人体健康和环境科学等领域具有重要意义。与其它离子检测方法相比,表面等离子体共振(surface plasmon resonance,SPR)技术具有无标记,灵敏度高和检测限低等优点,为重金属离子监测领域带来了新的可能性。本文综... 重金属离子浓度的检测对于人体健康和环境科学等领域具有重要意义。与其它离子检测方法相比,表面等离子体共振(surface plasmon resonance,SPR)技术具有无标记,灵敏度高和检测限低等优点,为重金属离子监测领域带来了新的可能性。本文综述了SPR传感技术在重金属离子检测中的应用及其技术进展。首先介绍了SPR传感的技术原理;然后在传感材料的选择以及表面修饰等方面,针对铅、汞等有害重金属离子,重点阐述了对灵敏度、线性动态范围和特异性等指标的改进;最后介绍了SPR成像传感技术在检测速度、灵敏度等方面取得的重大进展,展望了SPR技术的发展前景。 展开更多
关键词 表面等离子体共振 光学传感器 重金属离子 spr成像
下载PDF
Characteristic plume morphologies of atmospheric Ar and He plasma jets excited by a pulsed microwave hairpin resonator 被引量:1
13
作者 Zhao-Quan Chen Ben-Kuan Zhou +7 位作者 Huang Zhang Ling-Li Hong Chang-Lin Zou Ping Li Wei-Dong Zhao Xiao-Dong Liu Olga Stepanova A A Kudryavtsev 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第5期355-364,共10页
Different discharge morphologies in atmospheric Ar and He plasmas are excited by using a pulsed microwave hairpin resonator.Ar plasmas form an arched plasma plume at the opened end of the hairpin,whereas He plumes gen... Different discharge morphologies in atmospheric Ar and He plasmas are excited by using a pulsed microwave hairpin resonator.Ar plasmas form an arched plasma plume at the opened end of the hairpin,whereas He plumes generate only a contracted plasmas in between both tips of metal electrodes.Despite this different point,their discharge processes have three similar characteristics:(i)the ionization occurs at the main electrode firstly and then develops to the slave electrode,(ii)during the shrinking stage the middle domain of the discharge channels disappears at last,and(iii)even at zero power input(in between pulses)a weak light region always exists in the discharge channels.Both experimental results and electromagnetic simulations suggest that the discharge is resonantly excited by the local enhanced electric fields.In addition,Ar ionization and excitation energies are lower than those of He,the effect of Ar gas flow is far greater than that of He gas,and the contribution of accelerated electrons only locates at the domain with the strongest electric fields.These reasons could be used to interpret the different characteristic plume morphologies of the proposed atmospheric Ar and He plasmas. 展开更多
关键词 atmospheric pressure plasma jet pulsed microwave discharge surface plasmon polaritons hairpin resonant discharge
下载PDF
Resonant magneto-optical Kerr effect induced by hybrid plasma modes in ferromagnetic nanovoids 被引量:1
14
作者 张霞 石磊 +2 位作者 李晶 夏云杰 周仕明 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第11期489-497,共9页
With nanovoids buried in Co films, resonant structures were observed in spectra of polar magneto-optical Kerr effect(MOKE), where both a narrow bandwidth and high intensity were acquired. Through changing the thickn... With nanovoids buried in Co films, resonant structures were observed in spectra of polar magneto-optical Kerr effect(MOKE), where both a narrow bandwidth and high intensity were acquired. Through changing the thickness of Co films and the lattice of voids, different optical modes were introduced. For a very shallow array of voids, the resonant MOKE was induced by Ag plasma edge resonance, for deeper ones, hybrid plasma modes, such as void plasmons in the voids, surface lattice plasmons between the voids, and the co-action of them, etc. resulted in resonant MOKE. We found that resonant MOKE resulted from the void plasmons resonance which possesses the narrowest bandwidth for the lowest absorption of voids. The simulated electromagnetic field(EF) distribution consolidated different effects of these three optical modes on resonant MOKE modulation. Such resonant polar MOKE possesses high sensitivity, which might pave the way to on-chip MO devices. 展开更多
关键词 magneto-optical Kerr effect surface plasma polariton nanocavity mode surface lattice resonance
下载PDF
Comparison of Surface-enhanced Raman Scattering Spectra of Two Kinds of Silver Nanoplate Films
15
作者 TAO Jin-long TANG Bin +2 位作者 XU Shu-ping PAN Ling-yun XU Wei-qing 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第3期488-492,共5页
Surface-enhanced Raman scattering(SERS) spectra of different silver nanoplate selt-assembled tllmS at different excitation wavelengths were fairly compared. Shape conversion from silver nanoprisms to nanodisks on sl... Surface-enhanced Raman scattering(SERS) spectra of different silver nanoplate selt-assembled tllmS at different excitation wavelengths were fairly compared. Shape conversion from silver nanoprisms to nanodisks on slides was in situ carried out. The SERS spectra of 4-mercaptopyridine(4-MPY) on these anisotropic silver nanopar- ticle self-assembled films present that strong enhancement appeared when the excitation line and the surface plasmon resonance(SPR) band of silver substrate overlapped. In this model, the influence of the crystal planes of silver na- noplates on SERS enhancement could be ignored because the basal planes were nearly unchanged in two kinds of silver nanoplate self-assembled films. 展开更多
关键词 surface-enhanced Raman scattering(SERS) surface plasmon resonance(spr) Shape-dependant Silvernanoprism Silver nanodisk
下载PDF
Surface plasmon polaritons frequency-blue shift in low confinement factor excitation region
16
作者 Ling-Xi Hu Zhi-Qiang He +1 位作者 Min Hu Sheng-Gang Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第8期345-350,共6页
Surface plasmon polaritons'(SPPs')frequency blue shift is observed in finite-difference time-domain(FDTD)simulation of parallel electron excitation Au bulk structure.Comparing with cold dispersion of SPPs,an o... Surface plasmon polaritons'(SPPs')frequency blue shift is observed in finite-difference time-domain(FDTD)simulation of parallel electron excitation Au bulk structure.Comparing with cold dispersion of SPPs,an obvious frequency blue shift is obtained in low confinement region excitation simulation results.Then,according to SPPs'transverse attenuation characteristics,the excited frequency mode instead of cold dispersion corresponding frequency mode matches it.Thence,this excited mode is confirmed to be SPPs'mode.As is well known the lower the frequency,the smaller the confinement factor is and the lower the excitation efficiency,the wider the bandwidth of excited SPPs is.And considering the attenuation in whole structure,the excited surface field contains attenuation signal.In a low confinement factor region,the higher the SPPs'frequency,the higher the excitation efficiency is,while broadband frequency information obtained in attenuation signal provides high frequency information in stimulation signal.Thence,in the beam-wave interaction,as the signal oscillation time increases,the frequency of the oscillation field gradually increases.Thus,compared with cold dispersion,the frequency of excited SPP is blueshifted This hypothesis is verified by monitoring the time domain signal of excited field in low and high confinement factor regions and comparing them.Then,this frequency-blue shift is confirmed to have commonality of SPPs,which is independent of SPPs'material and structure.Finally,this frequency-blue shift is confirmed in an attenuated total reflection(ATR)experiment.Owing to frequency dependence of most of SPPs'devices,such as coherent enhancement radiation and enhancement transmission devices,the frequency-blue shift presented here is of great influence in the SPPs applications. 展开更多
关键词 surface plasmon polaritons(SPPs) frequency-blue shift surface plasmon resonance(spr) coherent enhancement radiation
下载PDF
纳米金用于SPR传感器检测小分子的研究进展
17
作者 王浩 郑欣欣 +4 位作者 孙宇航 陈子雷 颜朦朦 杨亲正 杨焕新 《齐鲁工业大学学报》 CAS 2023年第3期37-44,共8页
近年来,表面等离子体共振(Surface Plasmon Resonance,SPR)技术因具有可实时、动态监测SPR芯片上分子间相互作用的优点,而广泛应用于小分子传感检测领域。信号放大是小分子SPR传感器的重要研究内容,它决定小分子能否被检出及传感器灵敏... 近年来,表面等离子体共振(Surface Plasmon Resonance,SPR)技术因具有可实时、动态监测SPR芯片上分子间相互作用的优点,而广泛应用于小分子传感检测领域。信号放大是小分子SPR传感器的重要研究内容,它决定小分子能否被检出及传感器灵敏度,因此信号放大技术对其发展非常重要。纳米金因其高电子密度、介电特性及易修饰等特性而用于多种传感器的信号放大。重点介绍近5年来纳米金在小分子SPR传感器方面的应用情况,旨在为小分子SPR传感器的进一步发展提供参考依据。 展开更多
关键词 表面等离子体共振(spr)传感器 小分子 纳米金
下载PDF
群智能优化的动态基线调整在光纤SPR传感器信号处理中的应用
18
作者 戴峻峰 付丽辉 《传感技术学报》 CAS CSCD 北大核心 2023年第7期1092-1102,共11页
将谱宽(β)、基线下测量点数(m)、面积比(λ)作为最佳动态基线的选择依据,在两级适应度函数条件下,利用粒子群优化算法跟踪β、m、λ,寻找最佳组合参数下的动态基线,有效克服了传统基线选择较为随意的问题。搭建了光纤SPR测试装置,采集... 将谱宽(β)、基线下测量点数(m)、面积比(λ)作为最佳动态基线的选择依据,在两级适应度函数条件下,利用粒子群优化算法跟踪β、m、λ,寻找最佳组合参数下的动态基线,有效克服了传统基线选择较为随意的问题。搭建了光纤SPR测试装置,采集8种不同浓度的蔗糖标准溶液的光谱数据,将4种质心跟踪法进行实验对比。结果表明群智能优化动态基线法的预测精度和相关性均最好,可以有效提取质心参数,消除光源波动对测试结果的影响,为实现光纤SPR实时在线监测提供了一种有效途径,其共振波长拟合度为0.996 3,RMSE为1.78。另外,考察了三种质心计算参数的主导地位,结果表明:在设定相同适应度情况下,固定m方法效果最好,进而为质心参数的选择控制提供有效依据。 展开更多
关键词 光纤spr传感器 表面等离子共振效应 粒子群算法 群智能优化 动态基线
下载PDF
A Kind of Biomolecular Probe Sensor Based on TFBG Surface Plasma Resonance 被引量:1
19
作者 Mengwei XUE Qi JIANG +1 位作者 Chengjia ZHANG Jianqiang LIN 《Photonic Sensors》 SCIE EI CAS CSCD 2015年第2期102-108,共7页
This paper reports the application of the biomolecular probe sensor based on the tilted fiber Bragg grating (TFBG) surface plasma resonance (SPR) which can recognize the specificity of the specific molecule by dep... This paper reports the application of the biomolecular probe sensor based on the tilted fiber Bragg grating (TFBG) surface plasma resonance (SPR) which can recognize the specificity of the specific molecule by depositing sensitive biological membrane outside the active golden layer. The method of self-assembly was used to make the fixed sensitive biological membrane to achieve the best effect in the experiment. To illustrate the specific recognition of the DNA molecule, the TFBG-SPR biosensor was exposed to complementary DNA solutions with the concentration of 0.1 mmol/L and 0.05 mmol/L, respectively. The resonance wavelength of the TFBG-SPR biosensor increased gradually, indicating that the hybridization with the complementary DNA molecules changed the effective refractive index in the vicinity of the golden layer. Furthermore, the results illustrated the feasibility of the biomolecular probe sensor based on the TFBG surface plasma resonance for detecting the specific molecule. 展开更多
关键词 TFBG nanostructure golden layer surface plasma resonance BIOSENSOR
原文传递
波长型SPR检测仪的灵敏度探讨 被引量:5
20
作者 李海波 徐抒平 +2 位作者 刘钰 菅晓光 徐蔚青 《高等学校化学学报》 SCIE EI CAS CSCD 北大核心 2010年第11期2157-2161,共5页
利用自行设计构建的可变入射角的波长型表面等离子体共振(SPR)检测仪,在不同浓度的蔗糖溶液中测定了不同入射角度(80°~66°)的共振曲线,经过处理得到共振峰位、半高宽及灵敏度随入射角和样品折射率变化的三维图像.在此基础上... 利用自行设计构建的可变入射角的波长型表面等离子体共振(SPR)检测仪,在不同浓度的蔗糖溶液中测定了不同入射角度(80°~66°)的共振曲线,经过处理得到共振峰位、半高宽及灵敏度随入射角和样品折射率变化的三维图像.在此基础上探讨了波长型SPR检测仪的主要参数对仪器性能的影响,从理论和实验上证明了影响灵敏度的主要因素为共振波长,并且随着共振波长的增大,检测灵敏度迅速提高. 展开更多
关键词 表面等离子体共振(spr) 波长型spr检测仪 灵敏度 入射角 共振波长
下载PDF
上一页 1 2 22 下一页 到第
使用帮助 返回顶部