Stepped heating treatment has been applied to aluminum alloy thick plate to improve the mechanical performance and corrosion resistance.Accurate temperature control of the plate is the difficulty in engineering applic...Stepped heating treatment has been applied to aluminum alloy thick plate to improve the mechanical performance and corrosion resistance.Accurate temperature control of the plate is the difficulty in engineering application.The heating process,the calculation of surface heat transfer coefficient and the accurate temperature control method were studied based on measured heating temperature for the large-size thick plate.The results show that,the temperature difference between the surface and center of the thick plate is small.Based on the temperature uniformity,the surface heat transfer coefficient was calculated,and it is constant below300°C,but grows greatly over300°C.Consequently,a lumped parameter method(LPM)was developed to predict the plate temperature.A stepped solution treatment was designed by using LPM,and verified by finite element method(FEM)and experiments.Temperature curves calculated by LPM and FEM agree well with the experimental data,and the LPM is more convenient in engineering application.展开更多
AIM: To investigate the ocular hemodynamic effects of applying a hot compress to the eye.METHODS: The right eyes of five New Zealand white rabbits, both male and female, were hot-compressed for 18 min. An independentl...AIM: To investigate the ocular hemodynamic effects of applying a hot compress to the eye.METHODS: The right eyes of five New Zealand white rabbits, both male and female, were hot-compressed for 18 min. An independently designed novel ocular contacttype temperature measuring device was used to measure the ocular surface temperature before and after the heating. Relevant retrobulbar hemodynamic parameters such as peak systolic velocity(PSV), end diastolic velocity(EDV), and resistance index(RI) of each of the central retinal artery(CRA), long posterior ciliary artery(LPCA), and ophthalmic artery(OA), as well as the mean velocity(V_m) of the central retinal vein(CRV), were measured using a color Doppler flow imaging(CDFI) technique and expressed as mean values with standard deviation(mean±SD). A statistical analysis was conducted based on a paired t-test and the Wilcoxon signed-rank test. RESULTS: The employed real-time temperature measuring device was able to accurately measure ocular surface temperature during the hot-compress process. The temperature increased after the hot compress was applied. Analysis showed that the PSV and EDV values of the CRA and LPCA significantly increased after the application of the hot compress, as did the V_m of the CRV. There were no significant changes in the EDV of the OA nor the RI of each artery. CONCLUSION: This experiment, which is the first of its kind, confirms that the retrobulbar blood flow velocities can increase upon heating the ocular surface. This simple method may be useful in the future.展开更多
The interannual variations of atmospheric heat sources and moisture sinks over the Equatorial Pacific and their relations with the SST anomalies are studied using ECMWF reanalysis data from 1979 to 1993. It is found b...The interannual variations of atmospheric heat sources and moisture sinks over the Equatorial Pacific and their relations with the SST anomalies are studied using ECMWF reanalysis data from 1979 to 1993. It is found by singular value decomposition (SVD) analysis that the region in the tropical Pacific with high positive correlation between the vertically integrated heat source <Q1> anomaly and the SST anomaly, and between the vertically integrated moisture sink <Q2> anomaly and the SST anomaly, is mainly located in a long and narrow belt to the east of 170 °E between 5 °S and 5 °N. The analysis of the vertical structure of atmospheric heat sources and moisture sinks shows that the interannual variations of Q1, Q2 and SST in the equatorial central and eastern Pacific are strongly and positively correlated in the whole troposphere except the bottom (962.5 hPa) and the top (85 hPa) layers. However, in the western Pacific, the interannual variations of Q1 below 850 hPa is negatively related to the SST. The correlation coefficient at the level 962.5 hPa reaches even –0.59. In other layers the positive correlation between the interannual variations of Q1, Q2 and the SST are weak in the western Pacific.展开更多
To address the problems of thermal damage to a workpiece surface caused by the instantaneous high temperature during grinding and the difficulty in monitoring temperature in real time,the temperature field in the case...To address the problems of thermal damage to a workpiece surface caused by the instantaneous high temperature during grinding and the difficulty in monitoring temperature in real time,the temperature field in the case of composite surface grinding by a cup wheel is studied.In order to predict the grinding temperature,considering material removal and grinding force distribution,a nonuniform heat source model with different function distributions in the circumferential and radial directions in the cylindrical coordinate system is first proposed;then,the analytical model is deduced and the numerical model of the temperature field is established based on the heat source model.The validation experiments for grinding temperature field are carried out using a high-definition infrared thermal imager and an artificial thermocouple.Compared to the temperature field based on the uniform heat source model,the results based on the non-uniform heat source model are in better agreement with the actual temperature field,and the temperature prediction error is reduced from approximately 23% to 6%.Thus,the present study provides a more accurate theoretical basis for preventing bums in cup wheel surface grinding.展开更多
基金Project(2012CB619500)supported by the National Basic Research Program of ChinaProject(51375503)supported by the National Natural Science Foundation of China+1 种基金Project(2016YFB0300901)supported by the Major State Research Program of ChinaProject(2013A017)supported by the Bagui Scholars Program of Guangxi Zhuang Autonomous Region,China
文摘Stepped heating treatment has been applied to aluminum alloy thick plate to improve the mechanical performance and corrosion resistance.Accurate temperature control of the plate is the difficulty in engineering application.The heating process,the calculation of surface heat transfer coefficient and the accurate temperature control method were studied based on measured heating temperature for the large-size thick plate.The results show that,the temperature difference between the surface and center of the thick plate is small.Based on the temperature uniformity,the surface heat transfer coefficient was calculated,and it is constant below300°C,but grows greatly over300°C.Consequently,a lumped parameter method(LPM)was developed to predict the plate temperature.A stepped solution treatment was designed by using LPM,and verified by finite element method(FEM)and experiments.Temperature curves calculated by LPM and FEM agree well with the experimental data,and the LPM is more convenient in engineering application.
基金Supported by the National Natural Science Funds for Young Scholar(No.81400394)Heilongjiang Province Science Foundation for Youths(No.QC08C97)Research Fund for the Doctoral Program of the Second Affiliated Hospital of Harbin Medical University(No.BS2008-23)
文摘AIM: To investigate the ocular hemodynamic effects of applying a hot compress to the eye.METHODS: The right eyes of five New Zealand white rabbits, both male and female, were hot-compressed for 18 min. An independently designed novel ocular contacttype temperature measuring device was used to measure the ocular surface temperature before and after the heating. Relevant retrobulbar hemodynamic parameters such as peak systolic velocity(PSV), end diastolic velocity(EDV), and resistance index(RI) of each of the central retinal artery(CRA), long posterior ciliary artery(LPCA), and ophthalmic artery(OA), as well as the mean velocity(V_m) of the central retinal vein(CRV), were measured using a color Doppler flow imaging(CDFI) technique and expressed as mean values with standard deviation(mean±SD). A statistical analysis was conducted based on a paired t-test and the Wilcoxon signed-rank test. RESULTS: The employed real-time temperature measuring device was able to accurately measure ocular surface temperature during the hot-compress process. The temperature increased after the hot compress was applied. Analysis showed that the PSV and EDV values of the CRA and LPCA significantly increased after the application of the hot compress, as did the V_m of the CRV. There were no significant changes in the EDV of the OA nor the RI of each artery. CONCLUSION: This experiment, which is the first of its kind, confirms that the retrobulbar blood flow velocities can increase upon heating the ocular surface. This simple method may be useful in the future.
基金National Natural Science Foundation of China (40275026) Part One of National Key Fundamental Research and Development Planning Project (G1998040900)
文摘The interannual variations of atmospheric heat sources and moisture sinks over the Equatorial Pacific and their relations with the SST anomalies are studied using ECMWF reanalysis data from 1979 to 1993. It is found by singular value decomposition (SVD) analysis that the region in the tropical Pacific with high positive correlation between the vertically integrated heat source <Q1> anomaly and the SST anomaly, and between the vertically integrated moisture sink <Q2> anomaly and the SST anomaly, is mainly located in a long and narrow belt to the east of 170 °E between 5 °S and 5 °N. The analysis of the vertical structure of atmospheric heat sources and moisture sinks shows that the interannual variations of Q1, Q2 and SST in the equatorial central and eastern Pacific are strongly and positively correlated in the whole troposphere except the bottom (962.5 hPa) and the top (85 hPa) layers. However, in the western Pacific, the interannual variations of Q1 below 850 hPa is negatively related to the SST. The correlation coefficient at the level 962.5 hPa reaches even –0.59. In other layers the positive correlation between the interannual variations of Q1, Q2 and the SST are weak in the western Pacific.
基金This work was supported by the Natural Science Foundation of Hebei Province(Grant No.F2017202243)the Natural Science Foundation of Tianjin(Grant No.18JCTPJC54700)+1 种基金the State Key Laboratory of Robotics and System(HIT)(Grant No.SKLRS-2017-KF-15)the Science and Technology on Space Intelligent Control Laboratory(Grant No.ZDSYS-2017-08).
文摘To address the problems of thermal damage to a workpiece surface caused by the instantaneous high temperature during grinding and the difficulty in monitoring temperature in real time,the temperature field in the case of composite surface grinding by a cup wheel is studied.In order to predict the grinding temperature,considering material removal and grinding force distribution,a nonuniform heat source model with different function distributions in the circumferential and radial directions in the cylindrical coordinate system is first proposed;then,the analytical model is deduced and the numerical model of the temperature field is established based on the heat source model.The validation experiments for grinding temperature field are carried out using a high-definition infrared thermal imager and an artificial thermocouple.Compared to the temperature field based on the uniform heat source model,the results based on the non-uniform heat source model are in better agreement with the actual temperature field,and the temperature prediction error is reduced from approximately 23% to 6%.Thus,the present study provides a more accurate theoretical basis for preventing bums in cup wheel surface grinding.