A laboratory information system (LIS) established in a microbiology department has the potential to play an important role in the quality of microbiology data such as culture of blood, urine, stool, pus swab samples e...A laboratory information system (LIS) established in a microbiology department has the potential to play an important role in the quality of microbiology data such as culture of blood, urine, stool, pus swab samples etc. Such data could be effectively utilised to measure the burden of antimicrobial resistance among patients presented to various hospitals and clinics with an episode of an infectious illness of bacterial origin. A variety of clinical and epidemiological investigations are conducted using culture data and the presence of an electronic system such as LIS enhances such investigations and improves the reliability of measures of antimicrobial resistance owing to improved data quality as well as completeness of data gathered as opposed to paper based system. Therefore to improve surveillance of antimicrobial resistance in South Africa, there is a need to reinforce the functionality of the LIS in both public and private microbiology laboratories as this will help to improve internal quality control methodologies.展开更多
Objective:To evaluate the sensitivity pattern of bacterial pathogens in the intensive care unit(ICU) of a tertiary care of Falmawati Hospital Jakarta Indonesia.Methods:A cross sectional retrospective study of bacteria...Objective:To evaluate the sensitivity pattern of bacterial pathogens in the intensive care unit(ICU) of a tertiary care of Falmawati Hospital Jakarta Indonesia.Methods:A cross sectional retrospective study of bacterial pathogen was carried out on a total of 722 patients that were admitted to the ICU of Fatmawati Hospital Jakarta Indonesia during January 2009 to March 2010. All bacteria were identified by standard microbiologic methods,and(heir antibiotic susceptibility testing was performed using disk diffusion method.Results:Specimens were collected from 385 patients who were given antimicrobial treatment,of which 249(64.68%) were cultured positive and 136(35.32%) were negative.The most predominant isolate was Pseudomonas aeruginosa(P.aeruginosa)(26.5%) followed by Klebsiella pneumoniae(K.pneumoniae)(15.3%) and Staphylococcus epidermidis(14.9%).P.aeruginosa isolates showed high rate of resistance to cephalexin(95.3%),cefotaxime(64.1%),and ceftriaxone(60.9%).Amikacin was the most effective(84.4%) antibiotic against P.aeruginosa followed by imipenem(81.2%),and meropenem(75.0%).K.pneumoniae showed resistance to cephalexin(86.5%),ceftriaxone(75.7%),ceftazidime(73.0%),cefpirome(73.0%) and cefotaxime(67.9%),respectively.Conclusions:Most bacteria isolated from ICU of Fatmawati Hospital Jakarta Indonesia were resistant to the third generation of cephalosporins,and quinolone antibiotics.Regular surveillance of antibiotic susceptibility pallerns is very important for setting orders to guide the clinician in choosing empirical or directed therapy of infected patients.展开更多
文摘A laboratory information system (LIS) established in a microbiology department has the potential to play an important role in the quality of microbiology data such as culture of blood, urine, stool, pus swab samples etc. Such data could be effectively utilised to measure the burden of antimicrobial resistance among patients presented to various hospitals and clinics with an episode of an infectious illness of bacterial origin. A variety of clinical and epidemiological investigations are conducted using culture data and the presence of an electronic system such as LIS enhances such investigations and improves the reliability of measures of antimicrobial resistance owing to improved data quality as well as completeness of data gathered as opposed to paper based system. Therefore to improve surveillance of antimicrobial resistance in South Africa, there is a need to reinforce the functionality of the LIS in both public and private microbiology laboratories as this will help to improve internal quality control methodologies.
文摘Objective:To evaluate the sensitivity pattern of bacterial pathogens in the intensive care unit(ICU) of a tertiary care of Falmawati Hospital Jakarta Indonesia.Methods:A cross sectional retrospective study of bacterial pathogen was carried out on a total of 722 patients that were admitted to the ICU of Fatmawati Hospital Jakarta Indonesia during January 2009 to March 2010. All bacteria were identified by standard microbiologic methods,and(heir antibiotic susceptibility testing was performed using disk diffusion method.Results:Specimens were collected from 385 patients who were given antimicrobial treatment,of which 249(64.68%) were cultured positive and 136(35.32%) were negative.The most predominant isolate was Pseudomonas aeruginosa(P.aeruginosa)(26.5%) followed by Klebsiella pneumoniae(K.pneumoniae)(15.3%) and Staphylococcus epidermidis(14.9%).P.aeruginosa isolates showed high rate of resistance to cephalexin(95.3%),cefotaxime(64.1%),and ceftriaxone(60.9%).Amikacin was the most effective(84.4%) antibiotic against P.aeruginosa followed by imipenem(81.2%),and meropenem(75.0%).K.pneumoniae showed resistance to cephalexin(86.5%),ceftriaxone(75.7%),ceftazidime(73.0%),cefpirome(73.0%) and cefotaxime(67.9%),respectively.Conclusions:Most bacteria isolated from ICU of Fatmawati Hospital Jakarta Indonesia were resistant to the third generation of cephalosporins,and quinolone antibiotics.Regular surveillance of antibiotic susceptibility pallerns is very important for setting orders to guide the clinician in choosing empirical or directed therapy of infected patients.