为满足5.8 GHz雷达系统的需要,在HLMC55LP工艺中设计了一款12 bit SAR ADC,ADC的采样率为500 kHz/250 kHz两档可调,采用单调电容开关时序,且在电容阵列的高位部分加上2个冗余位设计,该冗余位对高位的CDAC建立误差,比较器误差都有一定的...为满足5.8 GHz雷达系统的需要,在HLMC55LP工艺中设计了一款12 bit SAR ADC,ADC的采样率为500 kHz/250 kHz两档可调,采用单调电容开关时序,且在电容阵列的高位部分加上2个冗余位设计,该冗余位对高位的CDAC建立误差,比较器误差都有一定的容忍能力,可以带来ADC性能上的提升。系统采用上极板采样,可以在采样周期结束的瞬间就开始逐位比较过程,省去了采用底极板采样第一拍CDAC建立的过程,提高了转换速度,相对于底极板采样也节省了一定的开关功耗。后仿结果表明,模拟输入20 kHz差分中频信号,在500 kHz采样频率,3.3 V电源电压下,ADC的有效位数为11.56 bit,SNR为71.04 dB,SFDR为80.37 dBc,功耗约为2 mW。展开更多
The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by...The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced.展开更多
文摘The results are presented of an experimental investigation of heat transfer in an air-liquid cooling system for a Switch-Mode Power Supply (SMPS) for TV digital power amplifiers. Since these SMPSs are characterized by high power and high compactness, thereby making the standard cooling techniques difficult to be used, a new cooling system is developed, using water and air as the cooling media. The active components (MOSFETs) are cooled with a liquid cold-plate, the passive ones (condensers, transformers, coils) with an air flow, in turn cooled by the cold-plate. By inserting the cooling system in an experimental tool where it is possible to control the cooling water, measurements are made of temperature in the significant points of the SMPS. The electric efficiency is also measured. The evaluation of the thermal performance of this cooling system is useful in order to limit its maximum operational temperature. The efficacy of the cooling system is demonstrated;the trends of efficiency and power dissipation are evidenced.