Energy recovery device (ERD) is an important part of the seawater reverse osmosis (SWRO) desalination system. There are principally two kinds of ERDs, the centrifugal type and the positive displacement (PD) type...Energy recovery device (ERD) is an important part of the seawater reverse osmosis (SWRO) desalination system. There are principally two kinds of ERDs, the centrifugal type and the positive displacement (PD) type. The PD type is of extensive concern and is preferred in large-scale plants. In this article, an innovative fluid switcher was presented and a two-cylinder hydraulic energy recovery unit with a lab-scale fluid switcher was set up. Tap water was used as the working medium instead of the actual seawater and brine in SWRO desalination plants. Under steady state operating conditions, the experimental results were obtained on the variations of the pressure and flow rate to and from the energy recovery unit. The hydraulic recovery efficiency (En) of the energy recovery unit with the fluid switcher reached up to 76.83%.展开更多
A DC regulated power supply with numerical control based on single chip microcomputer (SCM) is designed. SCM is the main controller and output voltage o{ DC power supply can be set by keyboard. The analog voltage ca...A DC regulated power supply with numerical control based on single chip microcomputer (SCM) is designed. SCM is the main controller and output voltage o{ DC power supply can be set by keyboard. The analog voltage can be obtained through D/A converter (DAC0832) so that different voltages can be provided by operational amplifier. The output voltage varies from 0 V to 12 V with the incremental value of 0. 1 V. The actual output voltage is shown in the nixietube. This DC regulated power supply is characterized by simple structure and easy operation.展开更多
A method which is especially suitable for microcomputer calculation of the true orientation distribution function (ODF) according to the maximum-entropy estimate is proposed for hexagonal system polycrystalline materi...A method which is especially suitable for microcomputer calculation of the true orientation distribution function (ODF) according to the maximum-entropy estimate is proposed for hexagonal system polycrystalline materials with physical symmetry.The resultant computational software system has been also designed and first carried out in a microcomputer PANAFACOM-U1200 being on line with the X-ray diffractometer D/max-3A.The simu- lated calculation shows that the method is concisely pragmatic and easily popularized,while the results obtained are trust worthy.展开更多
Pump controlled motor electrohydraulic servo systems are much used in circumstances where high power drive is needed. This kind of system has the advantage of energy-saving. But, it also has some defects that have to ...Pump controlled motor electrohydraulic servo systems are much used in circumstances where high power drive is needed. This kind of system has the advantage of energy-saving. But, it also has some defects that have to be improved. Microcomputer control of a pump controlled motor electrohydraulic servo system is studied. A PID controller is first adopted on the closed loop control system, and experimental results are obtained. Then, a model reference adaptive controller is designed and realised on the same system applying a single board microcomputer. Experimental results show that the dynamic properties of the adaptive control system is much better than those of the PID system under different inertia load conditions.展开更多
With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm...With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm system in many large- scale warehouses. Using advanced flame sensor, 485 bus communication, computer interactive software and related peripheral devices, this intelligent fire alarm system has functions of sound-light alarm and intelligent fire extinguishing. The human-com- puter interactive software was adopted for the remote control of the alarm main control panel through the 485 bus communication. This design of intelligent fire alarm system shows high reference and practical value to the development of intel- ligent alarm products with high integration and high reliability.展开更多
Presents a one grade adaptive controller with one reference model which is built according to δ MRACS adaptive control theory and used to control an actual high order hydraulic system, and the whole hardware system u...Presents a one grade adaptive controller with one reference model which is built according to δ MRACS adaptive control theory and used to control an actual high order hydraulic system, and the whole hardware system used, which includes a AT89C51 single chip microcomputer, 74Ls373 flip latch, 6116 store, eight bit ADC0809, and so on, and the satisfactory results obtained in study on hydraulic control system.展开更多
In this paper, a microcomputer program package for pharmacokinetics and biopharmaceutics (PKBP) was presented. This package is applicable to various calculations for pharmacokinetics and biopharmaceutics. Some mathema...In this paper, a microcomputer program package for pharmacokinetics and biopharmaceutics (PKBP) was presented. This package is applicable to various calculations for pharmacokinetics and biopharmaceutics. Some mathematical models and computing methods were developed. It has been used over 200 users.展开更多
This paper presents a microcomputer program system for the three-dimensional non-linear finite element method (FEM), which is developed for applications in mining engineering, such as excavation, filling, caving, damm...This paper presents a microcomputer program system for the three-dimensional non-linear finite element method (FEM), which is developed for applications in mining engineering, such as excavation, filling, caving, damming, etc. Our attention is focused on some of the key aspects of the programing techniques for an applicable microcomputer program, such as the structure of the program, data processing in the core, communication between the core and mass storage, input and output systems, etc. In the last part of this paper, two test examples are presented verifying the computational accuracy of this programing system and illustrating its applicability in practical engineering.展开更多
This paper describes the statistical methods of the comparison of the incidence or mortality rates in cancer registry and descriptive epidemiology, and the features of microcomputer program (CANTEST) which was designe...This paper describes the statistical methods of the comparison of the incidence or mortality rates in cancer registry and descriptive epidemiology, and the features of microcomputer program (CANTEST) which was designed to perform the methods. The program was written in IBM BASIC language. Using the program CANTEST we presented here the user can do several statistical tests or estimations as follow: 1. the comparison of the adjusted rates which were calculated by directly or indirectly standardized methods, 2. the calculation of the slope of regression line for testing the linear trends of the adjusted rates, 3. the estimation of the 95% or 99%conndence intervals of the directly adjusted rates, of the cumulative rates (0-64 and 0-74), and of the cumulative risk. Several examples are presented for testing the performances of the program.展开更多
For the first time, the split-unit experimental design was used in simulating free muscle transplantation by microneurovascular anastomoses on the rectus femoris of rabbits, and 12 functional indexes of contractile pr...For the first time, the split-unit experimental design was used in simulating free muscle transplantation by microneurovascular anastomoses on the rectus femoris of rabbits, and 12 functional indexes of contractile properties and the correlation between these indexes were analyzed with a microcomputer. The results showed that the maximum tetanic tension (TET) of grafted muscle would not return to normal level in the same animal until 1 year after operation (P>0.05), and, in our opinion,in view of tension balance between two sides, this was also the optimal time to appreciate the muscle function. It was found that the fatigue rate (FR) in each group was less than 25%, without any significant difference compared with that in the normal control side (F<F0.05, P>0.05). This was the functional evidence for the finding that the constituent ratio of 3 types of muscle fibers did not change in our study series. Therefore, the main character of fast contraction of the whole grafted muscles remained the same. There was a positive correlation between FR and TeT (r>r0.01), i.e. whenever TeT increased by 1 N, FR increased 0.12%.展开更多
基金the Seawater Desalination Research Programs of Tianjin(043185211-4)
文摘Energy recovery device (ERD) is an important part of the seawater reverse osmosis (SWRO) desalination system. There are principally two kinds of ERDs, the centrifugal type and the positive displacement (PD) type. The PD type is of extensive concern and is preferred in large-scale plants. In this article, an innovative fluid switcher was presented and a two-cylinder hydraulic energy recovery unit with a lab-scale fluid switcher was set up. Tap water was used as the working medium instead of the actual seawater and brine in SWRO desalination plants. Under steady state operating conditions, the experimental results were obtained on the variations of the pressure and flow rate to and from the energy recovery unit. The hydraulic recovery efficiency (En) of the energy recovery unit with the fluid switcher reached up to 76.83%.
文摘A DC regulated power supply with numerical control based on single chip microcomputer (SCM) is designed. SCM is the main controller and output voltage o{ DC power supply can be set by keyboard. The analog voltage can be obtained through D/A converter (DAC0832) so that different voltages can be provided by operational amplifier. The output voltage varies from 0 V to 12 V with the incremental value of 0. 1 V. The actual output voltage is shown in the nixietube. This DC regulated power supply is characterized by simple structure and easy operation.
文摘A method which is especially suitable for microcomputer calculation of the true orientation distribution function (ODF) according to the maximum-entropy estimate is proposed for hexagonal system polycrystalline materials with physical symmetry.The resultant computational software system has been also designed and first carried out in a microcomputer PANAFACOM-U1200 being on line with the X-ray diffractometer D/max-3A.The simu- lated calculation shows that the method is concisely pragmatic and easily popularized,while the results obtained are trust worthy.
基金The Project Supported by Doctoral Programme Foundation of Institution of Higher Education
文摘Pump controlled motor electrohydraulic servo systems are much used in circumstances where high power drive is needed. This kind of system has the advantage of energy-saving. But, it also has some defects that have to be improved. Microcomputer control of a pump controlled motor electrohydraulic servo system is studied. A PID controller is first adopted on the closed loop control system, and experimental results are obtained. Then, a model reference adaptive controller is designed and realised on the same system applying a single board microcomputer. Experimental results show that the dynamic properties of the adaptive control system is much better than those of the PID system under different inertia load conditions.
基金Supported by the National Natural Science Foundation of China(11275164)~~
文摘With principles of reliability, independence, practicality and economical effi- ciency, a set of intelligent fire alarm system based on AVRmega128 single chip microcomputer was designed to solve problems of fire alarm system in many large- scale warehouses. Using advanced flame sensor, 485 bus communication, computer interactive software and related peripheral devices, this intelligent fire alarm system has functions of sound-light alarm and intelligent fire extinguishing. The human-com- puter interactive software was adopted for the remote control of the alarm main control panel through the 485 bus communication. This design of intelligent fire alarm system shows high reference and practical value to the development of intel- ligent alarm products with high integration and high reliability.
文摘Presents a one grade adaptive controller with one reference model which is built according to δ MRACS adaptive control theory and used to control an actual high order hydraulic system, and the whole hardware system used, which includes a AT89C51 single chip microcomputer, 74Ls373 flip latch, 6116 store, eight bit ADC0809, and so on, and the satisfactory results obtained in study on hydraulic control system.
文摘In this paper, a microcomputer program package for pharmacokinetics and biopharmaceutics (PKBP) was presented. This package is applicable to various calculations for pharmacokinetics and biopharmaceutics. Some mathematical models and computing methods were developed. It has been used over 200 users.
文摘This paper presents a microcomputer program system for the three-dimensional non-linear finite element method (FEM), which is developed for applications in mining engineering, such as excavation, filling, caving, damming, etc. Our attention is focused on some of the key aspects of the programing techniques for an applicable microcomputer program, such as the structure of the program, data processing in the core, communication between the core and mass storage, input and output systems, etc. In the last part of this paper, two test examples are presented verifying the computational accuracy of this programing system and illustrating its applicability in practical engineering.
文摘This paper describes the statistical methods of the comparison of the incidence or mortality rates in cancer registry and descriptive epidemiology, and the features of microcomputer program (CANTEST) which was designed to perform the methods. The program was written in IBM BASIC language. Using the program CANTEST we presented here the user can do several statistical tests or estimations as follow: 1. the comparison of the adjusted rates which were calculated by directly or indirectly standardized methods, 2. the calculation of the slope of regression line for testing the linear trends of the adjusted rates, 3. the estimation of the 95% or 99%conndence intervals of the directly adjusted rates, of the cumulative rates (0-64 and 0-74), and of the cumulative risk. Several examples are presented for testing the performances of the program.
文摘For the first time, the split-unit experimental design was used in simulating free muscle transplantation by microneurovascular anastomoses on the rectus femoris of rabbits, and 12 functional indexes of contractile properties and the correlation between these indexes were analyzed with a microcomputer. The results showed that the maximum tetanic tension (TET) of grafted muscle would not return to normal level in the same animal until 1 year after operation (P>0.05), and, in our opinion,in view of tension balance between two sides, this was also the optimal time to appreciate the muscle function. It was found that the fatigue rate (FR) in each group was less than 25%, without any significant difference compared with that in the normal control side (F<F0.05, P>0.05). This was the functional evidence for the finding that the constituent ratio of 3 types of muscle fibers did not change in our study series. Therefore, the main character of fast contraction of the whole grafted muscles remained the same. There was a positive correlation between FR and TeT (r>r0.01), i.e. whenever TeT increased by 1 N, FR increased 0.12%.