Founded in 1919, Shanghai Hua Tong Switchgear Works ("HTSW" in short for below) is one of large enterprises on state level. With high and new technology, it is designed as an export base for mechanical and e...Founded in 1919, Shanghai Hua Tong Switchgear Works ("HTSW" in short for below) is one of large enterprises on state level. With high and new technology, it is designed as an export base for mechanical and electrical product of the Ministry of Machinery Industry as well. It has been awarded the honor of first grade factory in the competition for key and major project construction in Shanghai year by year,展开更多
Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard ...Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard and electromagnetic interference to secondary equipment.This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage(UHV)substations.In this paper,the statistical characteristics of TEV at UHV level are collected from field experiments,and are analyzed and compared to those from a repeated strike process.The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first.Then,statistical characteristics,such as the pulse number,duration of pulses,frequency components,magnitude and single pulse duration,are extracted.The transmission line theory is introduced to analyze the TEV and is validated by the experimental results.Finally,the relationship between the TEV and the repeated strike process is analyzed.This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage.The results contribute to the definition of the standard testing waveform of the TEV,and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.展开更多
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ...Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.展开更多
Due to imperfect manufacturing technology, design defects and environmental impact, the failure rate of 10 kV switchgear is very high. For this reason, based on taken present situation of traditional switchgear and th...Due to imperfect manufacturing technology, design defects and environmental impact, the failure rate of 10 kV switchgear is very high. For this reason, based on taken present situation of traditional switchgear and the current technical requirements for switchgear into account, a new reliable and safe modular high voltage switchgear design method is presented in this paper, which can reduce the failure rate of switchgear and improve the reliability of power supply. The electric field and temperature rise simulation model are established to check the reasonability and validity. By using the finite element software, the simulation results show that the design in this paper has a maximum temperature rise of 55 K for the main cabinet and a maximum temperature rise of 45 K for the deputy cabinet, which is far below the international standard of 70 K. The areas where the partial discharge is likely to occur within the switchgear are places such as the connection between bus-bar and cabinet, bus-bar joint and bus-bar corner. In order to avoid potential dangers, the discharge point must be located in time to prevent insulation fault of electrical equipment of the high voltage switchgear. The simulation results demonstrate that the design method in this paper greatly improve the reliability of switchgear and meets the demands of power system.展开更多
Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection i...Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection in power plant switchgear,a method based on continuous adaptive wavelet threshold switchgear PD signals denoising is proposed in this paper.By constructing a continuous adaptive threshold function and introducing adjustment parameters,the problems of over⁃processing of traditional hard threshold functions and incomplete denoising of soft threshold functions can be improved.The analysis results of simulated signals and measured signals show that the continuous adaptive wavelet threshold denoising method is significantly better than the traditional denoising method for the PD signal.The proposed method in this paper retains the characteristics of the original signal.Compared with the traditional denoising methods,after denoising the simulated signals,the signal⁃to⁃noise ratio(SNR)is increased by more than 30%,and the root⁃mean⁃square error(RMSE)is reduced by more than 30%.After denoising the real signal,the noise suppression ratio(NRR)is increased by more than 40%.The recognition accuracy rate of PD signal has also been improved to a certain extent,which proves that the method has a certain practicability.展开更多
An automatic 3D wiring method for switchgear design is proposed in this paper. First, wiring constraints are created, and a corresponding evaluation model is proposed. Then, based on the structure of the cabinet, we p...An automatic 3D wiring method for switchgear design is proposed in this paper. First, wiring constraints are created, and a corresponding evaluation model is proposed. Then, based on the structure of the cabinet, we propose a contour expansion scheme to construct rough paths. Different wiring features of the switchgear are used to connect rough local paths. All the paths are represented in a uniform data structure and forma path network. Finally, an improved A* algorithm is used to search the wiring path between the components in the routing network; the evaluation model is considered as heuristic rules for path searching. The result can satisfy the practical requirements of switchgear design. Experimental results are also provided.展开更多
This paper develops a novel distributed temperature measurement system based on DSP and DS18B20 digital thermometer. The real-time temperature of each node in the switchgear is obtained by several DS18B20s which are c...This paper develops a novel distributed temperature measurement system based on DSP and DS18B20 digital thermometer. The real-time temperature of each node in the switchgear is obtained by several DS18B20s which are connected on the 1-wire bus together. RS-485 master-slave communication protocol is used to centralize monitoring temperatures of several switchgear cabinets. The system also has the function of temperature alarm. The operation of simulation experiment has showed that the system is able to complete monitoring real-time temperatures in high voltage switchgear.展开更多
We present a temperature monitoring and warning system, which is based on wireless communi- cation technology and applied in train switchgear in this paper. The system is consists of three parts, including wireless te...We present a temperature monitoring and warning system, which is based on wireless communi- cation technology and applied in train switchgear in this paper. The system is consists of three parts, including wireless temperature detection module, inter-vehicle transmission networks module and?remote monitoring server. The switchgear contact temperature data are collected via the wireless temperature detection module and exchanged in inter-vehicle wireless networking by Zigbee modules. Then the temperature of train switchgear cabinets can be monitored remotely through the GPRS wireless communication.展开更多
This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medi...This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.展开更多
气体绝缘金属封闭开关设备(gas insulated metal enclosed switchgear,GIS)机械缺陷是导致设备故障的重要因素,针对单测点、单证据机械缺陷诊断模型信息缺失和精度不足问题,该文提出一种多层融合振动数据分析的GIS设备机械缺陷诊断方法...气体绝缘金属封闭开关设备(gas insulated metal enclosed switchgear,GIS)机械缺陷是导致设备故障的重要因素,针对单测点、单证据机械缺陷诊断模型信息缺失和精度不足问题,该文提出一种多层融合振动数据分析的GIS设备机械缺陷诊断方法。首先,基于真型GIS设备振动模拟平台试验研究测点位置与缺陷类型对振动行为的影响特性;然后,联合统计分析、模态分解、尺度变换方法提出机械振动信号整体与局部信息关注的复合参数分析方法,引入主成分分析开展多测点振动信息的特征层融合降维;最后,提出改进放缩权重的Dempster-Shafer(DS)证据理论和Bagging投票机制的强/弱基学习器决策层融合机制,联合构建多层融合振动数据分析的GIS设备机械缺陷诊断模型。结果表明:不同类型机械缺陷信号的响应幅值、特征频点和畸变程度存在显著差异,复合特征参量大小及分散程度各不相同;同时,测点位置对缺陷信号的复合振动特征参量的表现形式及分布区间也具有一定影响;基于多层融合数据分析的诊断模型实现缺陷有效识别,辨识准确率为98.66%,相比单一分类器诊断效果提升5.83%。该文可为GIS设备机械缺陷诊断方法提供有价值的参考。展开更多
当前国内外对气体绝缘金属封闭开关设备(gas insulated metal enclosed switchgear,GIS)的异常振动,尤其是引发振动的激励源、多频振动产生机理等问题缺少实质性研究进展。首先,建立受力模型,研究引发GIS振动的激励源,得到引发分箱型GI...当前国内外对气体绝缘金属封闭开关设备(gas insulated metal enclosed switchgear,GIS)的异常振动,尤其是引发振动的激励源、多频振动产生机理等问题缺少实质性研究进展。首先,建立受力模型,研究引发GIS振动的激励源,得到引发分箱型GIS振动的力源值,并指出正常运行状态,三相母线间电动力是主频振动的主要激励源。触头接触不良将导致触头斥力合力增大,地脚螺栓松动将导致系统固有频率的变化,影响非线性振动响应频谱特征;然后,将GIS按照薄壁圆柱壳进行研究,计算GIS壳体多阶固有频率,建立有效的非线性振动方程,首次利用解析方法揭示非线性GIS系统多频振动信号的产生机理;最后,研制成功振动信号采集系统,在550 k VGIS产品上设置典型机械缺陷,经实验验证,系统激发出的振动响应幅值极值点及频率与理论分析结果一致。论文的研究成果可为GIS机械缺陷的检测及诊断提供一定的支持和参考。展开更多
文摘Founded in 1919, Shanghai Hua Tong Switchgear Works ("HTSW" in short for below) is one of large enterprises on state level. With high and new technology, it is designed as an export base for mechanical and electrical product of the Ministry of Machinery Industry as well. It has been awarded the honor of first grade factory in the competition for key and major project construction in Shanghai year by year,
基金supported by the National Basic Research Program of China(973 Program) under grant 2011CB209405
文摘Transient enclosure voltage(TEV),which is a phenomenon induced by the inner dielectric breakdown of SF_6 during disconnector operations in a gas-insulated switchgear(GIS),may cause issues relating to shock hazard and electromagnetic interference to secondary equipment.This is a critical factor regarding the electromagnetic compatibility of ultra-high-voltage(UHV)substations.In this paper,the statistical characteristics of TEV at UHV level are collected from field experiments,and are analyzed and compared to those from a repeated strike process.The TEV waveforms during disconnector operations are recorded by a self-developed measurement system first.Then,statistical characteristics,such as the pulse number,duration of pulses,frequency components,magnitude and single pulse duration,are extracted.The transmission line theory is introduced to analyze the TEV and is validated by the experimental results.Finally,the relationship between the TEV and the repeated strike process is analyzed.This proves that the pulse voltage of the TEV is proportional to the corresponding breakdown voltage.The results contribute to the definition of the standard testing waveform of the TEV,and can aid the protection of electronic devices in substations by minimizing the threat of this phenomenon.
文摘Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique.
文摘Due to imperfect manufacturing technology, design defects and environmental impact, the failure rate of 10 kV switchgear is very high. For this reason, based on taken present situation of traditional switchgear and the current technical requirements for switchgear into account, a new reliable and safe modular high voltage switchgear design method is presented in this paper, which can reduce the failure rate of switchgear and improve the reliability of power supply. The electric field and temperature rise simulation model are established to check the reasonability and validity. By using the finite element software, the simulation results show that the design in this paper has a maximum temperature rise of 55 K for the main cabinet and a maximum temperature rise of 45 K for the deputy cabinet, which is far below the international standard of 70 K. The areas where the partial discharge is likely to occur within the switchgear are places such as the connection between bus-bar and cabinet, bus-bar joint and bus-bar corner. In order to avoid potential dangers, the discharge point must be located in time to prevent insulation fault of electrical equipment of the high voltage switchgear. The simulation results demonstrate that the design method in this paper greatly improve the reliability of switchgear and meets the demands of power system.
基金Sponsored by the Liaoning Provincial Department of Education Scientific Research Funding Project(Youth)(Grant No.JDL2020020)the Changzhou City Applied Basic Research Program(Grant No.CJ2020007).
文摘Partial discharge(PD)is an important reason for the insulation failure of the switchgear.In the process of PD detection,PD signal is often annihilated in strong noise.In order to improve the accuracy of PD detection in power plant switchgear,a method based on continuous adaptive wavelet threshold switchgear PD signals denoising is proposed in this paper.By constructing a continuous adaptive threshold function and introducing adjustment parameters,the problems of over⁃processing of traditional hard threshold functions and incomplete denoising of soft threshold functions can be improved.The analysis results of simulated signals and measured signals show that the continuous adaptive wavelet threshold denoising method is significantly better than the traditional denoising method for the PD signal.The proposed method in this paper retains the characteristics of the original signal.Compared with the traditional denoising methods,after denoising the simulated signals,the signal⁃to⁃noise ratio(SNR)is increased by more than 30%,and the root⁃mean⁃square error(RMSE)is reduced by more than 30%.After denoising the real signal,the noise suppression ratio(NRR)is increased by more than 40%.The recognition accuracy rate of PD signal has also been improved to a certain extent,which proves that the method has a certain practicability.
基金Supported by National Key Technologies R&D Program of China(2015BAF23B03)National Nature Science Foundation of China(61672307)
文摘An automatic 3D wiring method for switchgear design is proposed in this paper. First, wiring constraints are created, and a corresponding evaluation model is proposed. Then, based on the structure of the cabinet, we propose a contour expansion scheme to construct rough paths. Different wiring features of the switchgear are used to connect rough local paths. All the paths are represented in a uniform data structure and forma path network. Finally, an improved A* algorithm is used to search the wiring path between the components in the routing network; the evaluation model is considered as heuristic rules for path searching. The result can satisfy the practical requirements of switchgear design. Experimental results are also provided.
文摘This paper develops a novel distributed temperature measurement system based on DSP and DS18B20 digital thermometer. The real-time temperature of each node in the switchgear is obtained by several DS18B20s which are connected on the 1-wire bus together. RS-485 master-slave communication protocol is used to centralize monitoring temperatures of several switchgear cabinets. The system also has the function of temperature alarm. The operation of simulation experiment has showed that the system is able to complete monitoring real-time temperatures in high voltage switchgear.
文摘We present a temperature monitoring and warning system, which is based on wireless communi- cation technology and applied in train switchgear in this paper. The system is consists of three parts, including wireless temperature detection module, inter-vehicle transmission networks module and?remote monitoring server. The switchgear contact temperature data are collected via the wireless temperature detection module and exchanged in inter-vehicle wireless networking by Zigbee modules. Then the temperature of train switchgear cabinets can be monitored remotely through the GPRS wireless communication.
文摘This paper discusses a preferable solution to mitigate the CT (current transformer) saturation problem, and at same time, reduce the accuracy errors when considering the selection of CTs for installation on the medium voltage switchgear of a nuclear power plant. This consideration is important for both measurement and protection functions of the digital protective relays. This is a study to ascertain the best options for a suitable solution to prevent CT saturation in relations to its protective capabilities during short circuit fault without compromising the CT accuracy class during normal operation of the system, while ensuring its conformity to the design requirement is within limit. The advantages of current transformers have proven not only to be reliable and safe, but also are of easy handling, reduction of the cost and components on the MV (medium voltage) switchgear. The purpose of this research is to identify best approach to resolve the existing problems in the current protection system. With the view of LPCT (low power current transformer) which has been newly constructed by few manufacturers to provide good protection and a wide range of measuring function without errors, some other solutions will be considered in this research.
文摘气体绝缘金属封闭开关设备(gas insulated metal enclosed switchgear,GIS)机械缺陷是导致设备故障的重要因素,针对单测点、单证据机械缺陷诊断模型信息缺失和精度不足问题,该文提出一种多层融合振动数据分析的GIS设备机械缺陷诊断方法。首先,基于真型GIS设备振动模拟平台试验研究测点位置与缺陷类型对振动行为的影响特性;然后,联合统计分析、模态分解、尺度变换方法提出机械振动信号整体与局部信息关注的复合参数分析方法,引入主成分分析开展多测点振动信息的特征层融合降维;最后,提出改进放缩权重的Dempster-Shafer(DS)证据理论和Bagging投票机制的强/弱基学习器决策层融合机制,联合构建多层融合振动数据分析的GIS设备机械缺陷诊断模型。结果表明:不同类型机械缺陷信号的响应幅值、特征频点和畸变程度存在显著差异,复合特征参量大小及分散程度各不相同;同时,测点位置对缺陷信号的复合振动特征参量的表现形式及分布区间也具有一定影响;基于多层融合数据分析的诊断模型实现缺陷有效识别,辨识准确率为98.66%,相比单一分类器诊断效果提升5.83%。该文可为GIS设备机械缺陷诊断方法提供有价值的参考。
文摘当前国内外对气体绝缘金属封闭开关设备(gas insulated metal enclosed switchgear,GIS)的异常振动,尤其是引发振动的激励源、多频振动产生机理等问题缺少实质性研究进展。首先,建立受力模型,研究引发GIS振动的激励源,得到引发分箱型GIS振动的力源值,并指出正常运行状态,三相母线间电动力是主频振动的主要激励源。触头接触不良将导致触头斥力合力增大,地脚螺栓松动将导致系统固有频率的变化,影响非线性振动响应频谱特征;然后,将GIS按照薄壁圆柱壳进行研究,计算GIS壳体多阶固有频率,建立有效的非线性振动方程,首次利用解析方法揭示非线性GIS系统多频振动信号的产生机理;最后,研制成功振动信号采集系统,在550 k VGIS产品上设置典型机械缺陷,经实验验证,系统激发出的振动响应幅值极值点及频率与理论分析结果一致。论文的研究成果可为GIS机械缺陷的检测及诊断提供一定的支持和参考。