Micro-grid smooth switchover between different operation modes is important for steady operation and reliable power supply of micro-grid. In order to reduce the transient fluctuation of voltage and frequency during sw...Micro-grid smooth switchover between different operation modes is important for steady operation and reliable power supply of micro-grid. In order to reduce the transient fluctuation of voltage and frequency during switchover, this paper proposed a new switchover method based on controller state following. When transferring to island mode, the control method for inverter of storage device changed from PQ control to V/f control. Before switchover, the output of V/f controller is always following the output of PQ controller. So that the sudden change of output is avoided at the moment of switchover. A micro-grid model with photovoltaic and battery is built on DIgSILENT Power Factory simulation software, to simulate micro-grid switchover from grid-connected mode to island mode. Results show this method can effectively suppress the transient fluctuation of voltage and frequency, and reduce the influence of transient process on power grid. This conclusion has important practical significance on micro-grid smooth switchover from grid-con- nected mode to island mode.展开更多
Exposure to chloramphenicol(CAP),a chlorinated nitroaromatic antibiotic,can induce CAP-resistant bacteria/genes in diverse environments. A biocathode bioelectrochemical system(BES) was applied to reduce CAP under ...Exposure to chloramphenicol(CAP),a chlorinated nitroaromatic antibiotic,can induce CAP-resistant bacteria/genes in diverse environments. A biocathode bioelectrochemical system(BES) was applied to reduce CAP under switched operational temperatures.When switching from 25 to 10°C,the CAP reduction rate(kCAP) and the maximum amount of the dechlorinated reduced amine product(AMCl,with no antibacterial activity) by the biocathode communities were both markedly decreased. The acetate and ethanol yield from cathodophilic microbial glucose fermentation(with release of electrons) was also reduced. Formation of the product AMCl was enhanced by the biocathode dechloridation reaction compared with that produced from pure electrochemical or microbial dechloridation processes. The electrochemical and morphological analyses of cathode biofilms demonstrated that some cathodophilic microbes could adapt to low temperature and play a key role in CAP degradation. The resilient biocathode BES has a potential for the treatment of CAP-containing wastewater in temperature fluctuating environments.展开更多
文摘Micro-grid smooth switchover between different operation modes is important for steady operation and reliable power supply of micro-grid. In order to reduce the transient fluctuation of voltage and frequency during switchover, this paper proposed a new switchover method based on controller state following. When transferring to island mode, the control method for inverter of storage device changed from PQ control to V/f control. Before switchover, the output of V/f controller is always following the output of PQ controller. So that the sudden change of output is avoided at the moment of switchover. A micro-grid model with photovoltaic and battery is built on DIgSILENT Power Factory simulation software, to simulate micro-grid switchover from grid-connected mode to island mode. Results show this method can effectively suppress the transient fluctuation of voltage and frequency, and reduce the influence of transient process on power grid. This conclusion has important practical significance on micro-grid smooth switchover from grid-con- nected mode to island mode.
基金supported by the National Science Foundation for Distinguished Young Scholars of China (No.51225802)the National Natural Science Foundation of China (No.51178140)+2 种基金the National Creative Research Groups Project (No.51121062)the State Key Laboratory of Urban Water Resource and Environment of HIT (No.2013DX02)the Hundred Talents Program of the Chinese Academy of Sciences (No.29BR2013001)
文摘Exposure to chloramphenicol(CAP),a chlorinated nitroaromatic antibiotic,can induce CAP-resistant bacteria/genes in diverse environments. A biocathode bioelectrochemical system(BES) was applied to reduce CAP under switched operational temperatures.When switching from 25 to 10°C,the CAP reduction rate(kCAP) and the maximum amount of the dechlorinated reduced amine product(AMCl,with no antibacterial activity) by the biocathode communities were both markedly decreased. The acetate and ethanol yield from cathodophilic microbial glucose fermentation(with release of electrons) was also reduced. Formation of the product AMCl was enhanced by the biocathode dechloridation reaction compared with that produced from pure electrochemical or microbial dechloridation processes. The electrochemical and morphological analyses of cathode biofilms demonstrated that some cathodophilic microbes could adapt to low temperature and play a key role in CAP degradation. The resilient biocathode BES has a potential for the treatment of CAP-containing wastewater in temperature fluctuating environments.