In order to reduce the mismatch error, a direct current (DC) calibration method is introduced when the modulated microwave signal is measured. The microwave power is input to the left section of the power sensor, an...In order to reduce the mismatch error, a direct current (DC) calibration method is introduced when the modulated microwave signal is measured. The microwave power is input to the left section of the power sensor, and the DC power is input to the right of the power sensor. Due to the existence of parasitic loss and electromagnetic coupling, the microwave power results in a mismatch error. However, the DC power does not have the mismatch error. So the DC power applied in the right section can calibrate the mismatch error of the microwave power in the left section. The calibration factor is measured at different modulation rates and modulation depths.The measurement results show that the carrier frequency is the major factor influencing the measurement results. After calibration, the carrier frequency and the modulation rate have little effect on the output voltage. The frequency response becomes relatively flat in the frequency range up to 20 GHz, and the sensitivity on average is enhanced by about 0.12 mV/dBm. Therefore, the DC calibration method has a certain reference value for the terminal-type microwave power sensor.展开更多
To realize equal power splitting at two arbitrary gigahertz-frequencies, this paper presents a new type of Wilkinson dual frequency power divider, consisting of three-section transmission lines and a series RLC(resist...To realize equal power splitting at two arbitrary gigahertz-frequencies, this paper presents a new type of Wilkinson dual frequency power divider, consisting of three-section transmission lines and a series RLC(resistor, inductor and capacitor)circuit. By equating the [ABCD] matrix of the proposed circuit to that of the quarter-wave impedance transformer, coupled with even/odd mode analyses, the design equations of the proposed network are derived. For verification, two dual-frequency power dividers with dual-band operating frequencies at 0.6 GHz and 3.0 GHz, and 3.8 GHz and 10 GHz respectively are designed and simulated. Simulation results show that the dual-band ratio of the proposed power divider can be as large as 5. Comparisons of the simulation results at X-band and S-band with different power dividers indicate that the proposed dual-band power divider performs better under the scenario of the upper operating frequency extending to X-band.展开更多
Although the application of Symmetrical Components to time-dependent variables was introduced by Lyon in 1954, for many years its application was essentially restricted to electric machines. Recently, thanks to its ad...Although the application of Symmetrical Components to time-dependent variables was introduced by Lyon in 1954, for many years its application was essentially restricted to electric machines. Recently, thanks to its advantages, the Lyon transformation is also applied to power network calculation. In this paper, time-dependent symmetrical components are used to study the dynamic analysis of asymmetrical faults in a power system. The Lyon approach allows the calculation of the maximum values of overvoltages and overcurrents under transient conditions and to study network under non-sinusoidal conditions. Finally, some examples with longitudinal asymmetrical faults are illustrated.展开更多
A novel carbon foam with microporous structure(CFMS),with the advantages of a simple fabrication process,low energy consumption,large specific surface area and high conductivity,has been prepared by a facile one-step ...A novel carbon foam with microporous structure(CFMS),with the advantages of a simple fabrication process,low energy consumption,large specific surface area and high conductivity,has been prepared by a facile one-step carbonization.In addition,the carbon foam possesses suitable interlayer spacing in short range which is flexible to accommodate the deformation of carbon layer caused by the ion insertion and deinsertion at the charge and discharge state.Furthermore,a low cost carbon-based symmetric potassium dual-ion capacitor(PDIC),which integrates the virtues of potassium ion capacitors and dual-ion batteries,is successfully established with CFMS as both the battery-type cathode and the capacitor-type anode.PDIC displays a superior rate performance,an ultra-long cycle life(90%retention after 10000 cycles),and a high power density of 7800 W kg^-1 at an energy density of 39Whkg^-1.The PDIC also exhibits excellent ultrafast charge and slow discharge properties,with a full charge in just 60 s and a discharge time of more than 3000 s.展开更多
Distance relays are prone to symmetrical power swing phenomenon.To mitigate this issue,a dynamic threshold-supported algorithm is proposed.A single logic is not supposed to be secure for all cases.Thus,a supervisory a...Distance relays are prone to symmetrical power swing phenomenon.To mitigate this issue,a dynamic threshold-supported algorithm is proposed.A single logic is not supposed to be secure for all cases.Thus,a supervisory algorithm,as proposed in this study,can aid in the improvement of the immunity of the relay during swing cases and be sensitive to symmetrical faults.In the developed stages,a three-phase power signal was used and processed in two different steps:(i)extraction of the effective intrinsic mode function(IMF)selected from the Kurtosis analysis using the wavelet synchro-squeezing transform,and(ii)estimation of the average Euclidean distance index using the absolute values of the decomposed IMF’s.The adaptive threshold facilitated resistance to swing situations.At the onset of a symmetrical fault,the proposed algorithm efficiently discriminated among events using a dynamic threshold.The IEEE 39-bus test system and Indian Eastern Power Grid networks were modelled using PSCAD software,and cases were generated to test the efficacy of the method.The impact of the proposed method on a large-scale wind farm was also evaluated.A comparative analysis with other existing methods revealed the security and dependability of the proposed method.展开更多
In this paper,we consider the derivatives of intersection local time for two independent d-dimensional symmetricα-stable processes X^(α) and X^(α)with respective indices α and α.We first study the sufficient cond...In this paper,we consider the derivatives of intersection local time for two independent d-dimensional symmetricα-stable processes X^(α) and X^(α)with respective indices α and α.We first study the sufficient condition for the existence of the derivatives,which makes us obtain the exponential integrability and H?lder continuity.Then we show that this condition is also necessary for the existence of derivatives of intersection local time at the origin.Moreover,we also study the power variation of the derivatives.展开更多
The paper reports quality analysis and evaluation at 6 - 10/0.4 kV low-voltage distribution grids in Uzbekistan. Power quality frequently does not correspond to the rated value which is largely due to unbalanced phase...The paper reports quality analysis and evaluation at 6 - 10/0.4 kV low-voltage distribution grids in Uzbekistan. Power quality frequently does not correspond to the rated value which is largely due to unbalanced phase loading in grids and which also results in increased power loss. The study of the asymmetrical operating modes of the rural distribution networks of 0.4 kV was conducted in three steps: measurement, calculations and analysis of relevant data;providing practical guidelines and finally, implementing instruments to normalize grid operation. Measuring was conducted using certified instrumentation analyzer “MALIKA” designed by authors. The study and analysis of additional power losses as the function of indicators of asymmetrical features of voltage and current in operating 0.4 kV grids reveals that, quality of electric power at grids under investigation, merely does not meet the requirements of the Interstate Standard.展开更多
This paper, comparison of two sample tests, is motivated by the fact that in the test of significant difference between two independent samples, numerous methods can be adopted;each may lead to significant different r...This paper, comparison of two sample tests, is motivated by the fact that in the test of significant difference between two independent samples, numerous methods can be adopted;each may lead to significant different results;this implies that wrong choice of test statistic could lead to erroneous conclusion. To prevent misleading information, there is a need for proper investigation of some selected methods for test of significant difference between variables/subjects most especially, independent samples. The paper examines the efficiency and sensitivity of four test statistics to ascertain which test performs better. Based on the results, the relative efficiency favours median test as being more efficient than modified median test for both symmetric and asymmetric distributions. In terms of power of test, median test is more sensitive than Modified Median (MMED) test since it has higher power irrespective of the sample sizes for both symmetric and asymmetric distribution. In terms of relative efficiency for asymmetric distribution Modified Mann-Whitney U test is more efficient than Mann-Whitney U test (MMWU), and then for symmetric distribution, Mann-Whitney U test (MMWU) is more efficient than Modified Mann-Whitney in sample size of 5;but for other sample sizes considered Modified Mann-Whitney U test (MMWU) is better than Mann-Whitney. Using power of test for both symmetric and asymmetric distributions, Mann-Whitney is more sensitive than Modified Mann-Whitney U test (MMWU) because it has higher power.展开更多
In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach h...In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.展开更多
基金The National Natural Science Foundation of China(No.60976094)the National High Technology Research and Development Program of China(863 Program)(No.2007AA04Z328)
文摘In order to reduce the mismatch error, a direct current (DC) calibration method is introduced when the modulated microwave signal is measured. The microwave power is input to the left section of the power sensor, and the DC power is input to the right of the power sensor. Due to the existence of parasitic loss and electromagnetic coupling, the microwave power results in a mismatch error. However, the DC power does not have the mismatch error. So the DC power applied in the right section can calibrate the mismatch error of the microwave power in the left section. The calibration factor is measured at different modulation rates and modulation depths.The measurement results show that the carrier frequency is the major factor influencing the measurement results. After calibration, the carrier frequency and the modulation rate have little effect on the output voltage. The frequency response becomes relatively flat in the frequency range up to 20 GHz, and the sensitivity on average is enhanced by about 0.12 mV/dBm. Therefore, the DC calibration method has a certain reference value for the terminal-type microwave power sensor.
文摘To realize equal power splitting at two arbitrary gigahertz-frequencies, this paper presents a new type of Wilkinson dual frequency power divider, consisting of three-section transmission lines and a series RLC(resistor, inductor and capacitor)circuit. By equating the [ABCD] matrix of the proposed circuit to that of the quarter-wave impedance transformer, coupled with even/odd mode analyses, the design equations of the proposed network are derived. For verification, two dual-frequency power dividers with dual-band operating frequencies at 0.6 GHz and 3.0 GHz, and 3.8 GHz and 10 GHz respectively are designed and simulated. Simulation results show that the dual-band ratio of the proposed power divider can be as large as 5. Comparisons of the simulation results at X-band and S-band with different power dividers indicate that the proposed dual-band power divider performs better under the scenario of the upper operating frequency extending to X-band.
文摘Although the application of Symmetrical Components to time-dependent variables was introduced by Lyon in 1954, for many years its application was essentially restricted to electric machines. Recently, thanks to its advantages, the Lyon transformation is also applied to power network calculation. In this paper, time-dependent symmetrical components are used to study the dynamic analysis of asymmetrical faults in a power system. The Lyon approach allows the calculation of the maximum values of overvoltages and overcurrents under transient conditions and to study network under non-sinusoidal conditions. Finally, some examples with longitudinal asymmetrical faults are illustrated.
基金financially supported by the National Natural Science Foundation of China(Nos.51672078 and 21473052)Hunan University State Key Laboratory of Advanced Design and Manufacturing for Vehicle Body Independent Research Project(No.71675004)+2 种基金the Fundamental Research Funds for the Central UniversitiesHunan Natural Science Foundation(2019JJ40031)Foundation of State Key Laboratory of Coal Conversion(Grant J1718-903)。
文摘A novel carbon foam with microporous structure(CFMS),with the advantages of a simple fabrication process,low energy consumption,large specific surface area and high conductivity,has been prepared by a facile one-step carbonization.In addition,the carbon foam possesses suitable interlayer spacing in short range which is flexible to accommodate the deformation of carbon layer caused by the ion insertion and deinsertion at the charge and discharge state.Furthermore,a low cost carbon-based symmetric potassium dual-ion capacitor(PDIC),which integrates the virtues of potassium ion capacitors and dual-ion batteries,is successfully established with CFMS as both the battery-type cathode and the capacitor-type anode.PDIC displays a superior rate performance,an ultra-long cycle life(90%retention after 10000 cycles),and a high power density of 7800 W kg^-1 at an energy density of 39Whkg^-1.The PDIC also exhibits excellent ultrafast charge and slow discharge properties,with a full charge in just 60 s and a discharge time of more than 3000 s.
文摘Distance relays are prone to symmetrical power swing phenomenon.To mitigate this issue,a dynamic threshold-supported algorithm is proposed.A single logic is not supposed to be secure for all cases.Thus,a supervisory algorithm,as proposed in this study,can aid in the improvement of the immunity of the relay during swing cases and be sensitive to symmetrical faults.In the developed stages,a three-phase power signal was used and processed in two different steps:(i)extraction of the effective intrinsic mode function(IMF)selected from the Kurtosis analysis using the wavelet synchro-squeezing transform,and(ii)estimation of the average Euclidean distance index using the absolute values of the decomposed IMF’s.The adaptive threshold facilitated resistance to swing situations.At the onset of a symmetrical fault,the proposed algorithm efficiently discriminated among events using a dynamic threshold.The IEEE 39-bus test system and Indian Eastern Power Grid networks were modelled using PSCAD software,and cases were generated to test the efficacy of the method.The impact of the proposed method on a large-scale wind farm was also evaluated.A comparative analysis with other existing methods revealed the security and dependability of the proposed method.
基金Supported by National Natural Science Foundation of China(Grant Nos.12071003,12201294)Natural Science Foundation of Jiangsu Province,China(Grant No.BK20220865)。
文摘In this paper,we consider the derivatives of intersection local time for two independent d-dimensional symmetricα-stable processes X^(α) and X^(α)with respective indices α and α.We first study the sufficient condition for the existence of the derivatives,which makes us obtain the exponential integrability and H?lder continuity.Then we show that this condition is also necessary for the existence of derivatives of intersection local time at the origin.Moreover,we also study the power variation of the derivatives.
文摘The paper reports quality analysis and evaluation at 6 - 10/0.4 kV low-voltage distribution grids in Uzbekistan. Power quality frequently does not correspond to the rated value which is largely due to unbalanced phase loading in grids and which also results in increased power loss. The study of the asymmetrical operating modes of the rural distribution networks of 0.4 kV was conducted in three steps: measurement, calculations and analysis of relevant data;providing practical guidelines and finally, implementing instruments to normalize grid operation. Measuring was conducted using certified instrumentation analyzer “MALIKA” designed by authors. The study and analysis of additional power losses as the function of indicators of asymmetrical features of voltage and current in operating 0.4 kV grids reveals that, quality of electric power at grids under investigation, merely does not meet the requirements of the Interstate Standard.
文摘This paper, comparison of two sample tests, is motivated by the fact that in the test of significant difference between two independent samples, numerous methods can be adopted;each may lead to significant different results;this implies that wrong choice of test statistic could lead to erroneous conclusion. To prevent misleading information, there is a need for proper investigation of some selected methods for test of significant difference between variables/subjects most especially, independent samples. The paper examines the efficiency and sensitivity of four test statistics to ascertain which test performs better. Based on the results, the relative efficiency favours median test as being more efficient than modified median test for both symmetric and asymmetric distributions. In terms of power of test, median test is more sensitive than Modified Median (MMED) test since it has higher power irrespective of the sample sizes for both symmetric and asymmetric distribution. In terms of relative efficiency for asymmetric distribution Modified Mann-Whitney U test is more efficient than Mann-Whitney U test (MMWU), and then for symmetric distribution, Mann-Whitney U test (MMWU) is more efficient than Modified Mann-Whitney in sample size of 5;but for other sample sizes considered Modified Mann-Whitney U test (MMWU) is better than Mann-Whitney. Using power of test for both symmetric and asymmetric distributions, Mann-Whitney is more sensitive than Modified Mann-Whitney U test (MMWU) because it has higher power.
文摘In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.