Design of DSTATCOM Controller for Compensating Unbalances 被引量:1
1
作者 Murugesan Kullan Ranganath Muthu +1 位作者 Jebamalai Benny Mervin Vijayenthiran Subramanian 《Circuits and Systems》 2016年第9期2362-2372,共11页
In a three phase power system, the voltages at the generation side are in sinusoidal and equal in magnitude with 120? phase difference between the phases. However, at the load side voltages may become unbalanced due t... In a three phase power system, the voltages at the generation side are in sinusoidal and equal in magnitude with 120? phase difference between the phases. However, at the load side voltages may become unbalanced due to unequal voltage magnitudes at the fundamental frequency, phase angle deviations or unequal distribution of single phase loads. The voltage unbalance is a major power quality issue, because a small unbalance in the phase voltages can cause a larger unbalance in the phase currents. A completely balanced three-phase three wire system contains only positive sequence components of voltage, current and impedance, whereas unbalanced system contains both positive and negative sequence components of voltages and currents. The negative sequence component of current in the unbalanced system increases the temperature and losses in the equipments. Hence, it is necessary to mitigate this problem by supplying the negative sequence current to the load at the load side and keep the source side balanced. This paper proposes the shunt connected, current injecting Distribution Static Synchronous Compensator (DSTATCOM) with appropriate controller to mitigate the unbalanced load current. The symmetrical components based Hysteresis Current Controller (HCC) is designed for DSTATCOM to diminish the unbalances in a three-phase three-wire system. The performance of the controller is studied by simulating the entire system in the MATLAB/Simulink environment. The DSTATCOM with HCC is found to be better than other controllers because it is suitable for compensating both balanced and unbalanced loads. 展开更多
关键词 COMPENSATION DSTATCOM Hysteresis Current Controller symmetrical components Unbalanced Systems Negative Sequence Current
下载PDF
Consistency evaluation of the current distribution of short-circuit tests in AT feeding systems for high-speed railways
2
作者 Qing-an Ma Wei Liu 《Journal of Modern Transportation》 2018年第3期163-172,共10页
To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China. However,... To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China. However, no systematic algorithm yet exists to evaluate the consistency of the current distribution of short-circuit tests. A methodology is proposed in this paper to address this problem. Based on Kirchhoff’s current law and the generalized method of symmetrical components, the current deviations of the AT feeding systems are analysed and then normalized with the short-circuit current as they vary greatly with systems and short-circuit sites. It is also found that the short-circuit current varies with the calculation methods, and its unbiased standard deviation also reflects the consistency of the short-circuit test. The mean and maximum of the current deviations, as well as the unbiased standard deviation of the short-circuit current, show the consistency of the short-circuit test from different aspects,although the last two items are highly relevant. Therefore, a unified evaluation index is defined as the sum of the three items, and then applied in two case studies to test its performance. The results show that, the proposed index canclearly distinguish the consistency of the short-circuit tests and may be used to sort the short-circuit tests for fault location systems. Besides, some short-circuit tests may have very poor consistency indices, and thus are not applicable to the tuning of fault location systems. In the authors’ opinion, the determination of the threshold of the proposed index needs further investigation. 展开更多
关键词 Autotransformer feeding system Short-circuittest Consistency evaluation Kirchhoff’s current law Generalized method of symmetrical components
下载PDF
Electric Power Quality Analysis 6-10/0.4 kV Distribution Networks
3
作者 Kholiddinov Ilkombek Khosiljonovich 《Energy and Power Engineering》 2016年第6期263-269,共8页
The paper reports quality analysis and evaluation at 6 - 10/0.4 kV low-voltage distribution grids in Uzbekistan. Power quality frequently does not correspond to the rated value which is largely due to unbalanced phase... The paper reports quality analysis and evaluation at 6 - 10/0.4 kV low-voltage distribution grids in Uzbekistan. Power quality frequently does not correspond to the rated value which is largely due to unbalanced phase loading in grids and which also results in increased power loss. The study of the asymmetrical operating modes of the rural distribution networks of 0.4 kV was conducted in three steps: measurement, calculations and analysis of relevant data;providing practical guidelines and finally, implementing instruments to normalize grid operation. Measuring was conducted using certified instrumentation analyzer “MALIKA” designed by authors. The study and analysis of additional power losses as the function of indicators of asymmetrical features of voltage and current in operating 0.4 kV grids reveals that, quality of electric power at grids under investigation, merely does not meet the requirements of the Interstate Standard. 展开更多
关键词 Electric Power Quality Indicators Power Grids Power Losses The Method of symmetrical components
下载PDF
Adaline and FIS Techniques for Fault Identification in HV Transmission Line
4
作者 K. Elango G. Geetha 《Circuits and Systems》 2016年第10期3183-3192,共10页
This paper is to identify and classify the various types of shunt and line faults in transmission line. The faults may be an insulation failure, lightning or accidental faulty operation. In a transmission line protect... This paper is to identify and classify the various types of shunt and line faults in transmission line. The faults may be an insulation failure, lightning or accidental faulty operation. In a transmission line protection important factor is identifying a fault because if any error occurs in finding fault may leads to abnormal operation of the protection system. So either a disturbance or steady state variation is called power quality variation. The proposed test system is modeled based on the neural network and fuzzy algorithm. The online symmetrical components are extracted by this above algorithm. The fuzzy is used to separate the oscillating components and average components. Here input for the fuzzy is trained by using neural network. It is based on current samples and very effective in fault classifier using rule base. This method is very much suitable for online implementation. 展开更多
关键词 symmetrical components FUZZY Fuzzy Interference System Transmission-Line Protection
下载PDF
Fault diagnosis and protection of motors in coal shearer
5
作者 陈霞 王瑾 《Journal of Measurement Science and Instrumentation》 CAS 2012年第1期34-38,共5页
Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And prob... Symmetrical components method is employed in analysis of the characteristic motor faults.Motor protection method is put forward based on detecting positive sequence,negative sequence and zero sequence current.And problems of lack of motor overload capacity in existing mining motor protection system,impact of dynamic current on stage and definite-time delay operation and inaccuracy of criterion phase failure protection are analyzed.The unbalanced faults protection and inverse-time overload protection,which can make protection time change with the current movement,are proposed.The above problems can be solved,and the reliability and intelligent of coal shearer are improved. 展开更多
关键词 symmetrical component method mining machine inverse-time protection protection of motor
下载PDF
An Open-circuit Fault Diagnosis Method for PMSM Drives Using Symmetrical and DC Components
6
作者 Wentao Huang Jiachen Du +1 位作者 Wei Hua Qigao Fan 《Chinese Journal of Electrical Engineering》 CSCD 2021年第3期124-135,共12页
In this paper,a diagnostic method based on symmetrical and DC components is presented for multiple open-circuit faults(OCFs)in a three-phase permanent magnet synchronous motor drive.The remaining phase currents under ... In this paper,a diagnostic method based on symmetrical and DC components is presented for multiple open-circuit faults(OCFs)in a three-phase permanent magnet synchronous motor drive.The remaining phase currents under faulty situations are theoretically analyzed based on the Fourier series method and the mechanism of torque generation.To evaluate the asymmetry and discriminate fault types,the magnitude ratio of the positive sequence to the negative sequence of phase currents is designed as a fault detection index.Thereafter,the DC components of the phase currents in different reference frames are utilized to locate faults.Specifically,the polarities of the DC contents in the natural reference frame are utilized to locate a single OCF and two OCFs in different legs.Two OCFs in the same leg are diagnosed by evaluating the signs of the phase currents in the dq reference frame with a negative rotating direction.The simulated and experimental results validate the effectiveness of the developed method in fault detection and robustness against operating point and motor parameter variations. 展开更多
关键词 Permanent magnet synchronous motor open-circuit fault fault diagnosis symmetrical component
原文传递
A New Diagnostic Method for Winding Short-Circuit Fault for SRM Based on Symmetrical Component Analysis 被引量:3
7
作者 Li Xiao Hexu Sun +2 位作者 Feng Gao Shuping Hou Lipeng Li 《Chinese Journal of Electrical Engineering》 CSCD 2018年第1期74-82,共9页
Winding short-circuit is one of the more common faults in switched reluctance motors(SRM).This paper takes an in-depth look at winding short-circuit.The characteristic of non-sinusoidal intermittent single phase curre... Winding short-circuit is one of the more common faults in switched reluctance motors(SRM).This paper takes an in-depth look at winding short-circuit.The characteristic of non-sinusoidal intermittent single phase current,fundamental components are extracted to reconstruct four phase symmetrical currents based on spectrum analysis of phase currents.The method of symmetrical component is used to calculate positive and negative sequence components of reconstructed currents,where then the ratio between positive and negative sequence component is seen as a fault feature and the diagnostic criterion is proposed.The simulation and experimental results are presented to confirm the implementation of the proposed method. 展开更多
关键词 symmetrical component spectral analysis winding short-circuit fault switched reluctance motor
原文传递
Parallel Perturbed Gauss-Newton State Estimator Based on Fortescue Transformation for Unbalanced Power Systems
8
作者 Izudin Džafić 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第6期1778-1783,共6页
This letter extends the complex-variable perturbed Gauss-Newton method to estimate the state of unbalanced power systems by exploiting the Fortescue transformation.It proposes a novel and efficient graph-based way to ... This letter extends the complex-variable perturbed Gauss-Newton method to estimate the state of unbalanced power systems by exploiting the Fortescue transformation.It proposes a novel and efficient graph-based way to deal with singularities due to zero-sequence network parts bounded with delta transformer windings and isolated from the ground.The estimator can handle both phasor and complex power measurements.Compared with the standard complex-variable unbalanced state estimator,it achieves better numerical stability and a speed-up of around three times using a sequential implementation and five times using parallel execution. 展开更多
关键词 Delta-windings Fortescue transformation iterative algorithms least-squares approximation parallel algorithm perturbation methods ILL-CONDITIONING state estimation symmetrical components
原文传递
Robust fault analysis in transmission lines using Synchrophasor measurements
9
作者 Rajaraman P. Sundaravaradan N.A. +2 位作者 Mallikarjuna B. Jaya Bharata Reddy M. Mohanta D.K. 《Protection and Control of Modern Power Systems》 2018年第1期108-120,共13页
As more electric utilities and transmission system operators move toward the smart grid concept,robust fault analysis has become increasingly complex.This paper proposes a methodology for the detection,classification,... As more electric utilities and transmission system operators move toward the smart grid concept,robust fault analysis has become increasingly complex.This paper proposes a methodology for the detection,classification,and localization of transmission line faults using Synchrophasor measurements.The technique involves the extraction of phasors from the instantaneous three-phase voltages and currents at each bus in the system which are then decomposed into their symmetrical components.These components are sent to the phasor data concentrator(PDC)for real-time fault analysis,which is completed within 2–3 cycles after fault inception.The advantages of this technique are its accuracy and speed,so that fault information may be appropriately communicated to facilitate system restoration.The proposed algorithm is independent of the transmission system topology and displays high accuracy in its results,even with varying parameters such as fault distance,fault inception angle and fault impedance.The proposed algorithm is validated using a three-bus system as well as the Western System Coordinating Council(WSCC)nine bus system.The proposed algorithm is shown to accurately detect the faulted line and classify the fault in all the test cases presented. 展开更多
关键词 Transmission line faults Fault analysis Phasor measurement units symmetrical components