期刊文献+
共找到15篇文章
< 1 >
每页显示 20 50 100
A frequency domain estimation and compensation method for system synchronization parameters of distributed-HFSWR
1
作者 WANG Hongyong SUO Ying +3 位作者 DENG Weibo WU Xiaochuan BAI Yang ZHANG Xin 《Journal of Systems Engineering and Electronics》 SCIE CSCD 2024年第5期1084-1097,共14页
To analyze the influence of time synchronization error,phase synchronization error,frequency synchronization error,internal delay of the transceiver system,and range error and angle error between the unit radars on th... To analyze the influence of time synchronization error,phase synchronization error,frequency synchronization error,internal delay of the transceiver system,and range error and angle error between the unit radars on the target detection performance,firstly,a spatial detection model of distributed high-frequency surface wave radar(distributed-HFSWR)is established in this paper.In this model,a method for accurate extraction of direct wave spectrum based on curve fitting is proposed to obtain accurate system internal delay and frequency synchronization error under complex electromagnetic environment background and low signal to noise ratio(SNR),and to compensate for the shift of range and Doppler frequency caused by time-frequency synchronization error.The direct wave component is extracted from the spectrum,the range estimation error and Doppler estimation error are reduced by the method of curve fitting,and the fitting accuracy of the parameters is improved.Then,the influence of frequency synchronization error on target range and radial Doppler velocity is quantitatively analyzed.The relationship between frequency synchronization error and radial Doppler velocity shift and range shift is given.Finally,the system synchronization parameters of the trial distributed-HFSWR are obtained by the proposed spectrum extraction method based on curve fitting,the experimental data is compensated to correct the shift of the target,and finally the correct target parameter information is obtained.Simulations and experimental results demonstrate the superiority and correctness of the proposed method,theoretical derivation and detection model proposed in this paper. 展开更多
关键词 distributed high-frequency surface wave radar(distributed-HFSWR) direct wave synchronization error curve fitting system synchronization parameter compensation
下载PDF
Comparative study of effectiveness of different var compensation devices in large-scale power networks 被引量:3
2
作者 Reza Sirjani Azah Mohamed Hussain Shareef 《Journal of Central South University》 SCIE EI CAS 2013年第3期715-723,共9页
A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power netwo... A comparison of the effectiveness of installing reactive power compensators,such as shunt capacitors,static var compensators(SVCs),and static synchronous compensators(STATCOMs),was presented in large-scale power networks.A suitable bus was first identified using modal analysis method.The single shunt capacitor,single SVC,and single STATCOM were installed separately on the most critical bus.The effects of the installation of different devices on power loss reduction,voltage profile improvement,and voltage stability margin enhancement were examined and compared for 57-and 118-bus transmission systems.The comparative study results show that SVC,and STATCOM are expensive compared to shunt capacitor,yet the effect of installing STATCOM is better than SVC and the effect of installing SVC is better than that of shunt capacitor in achieving power loss reduction,voltage profile improvement and voltage stability margin enhancement. 展开更多
关键词 shunt capacitor static var compensator static synchronous compensator power loss voltage profile voltage stability
下载PDF
Comprehensive Energy-Saving Optimization Model of Asynchronous Motor for Voltage Regulation Based on Static Synchronous Compensator
3
作者 Shuqiao Dan 《Energy Engineering》 EI 2022年第3期1047-1057,共11页
There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a compreh... There are several problems existing in the direct starting of asynchronous motor such as large starting current,reactive power absorption from network side and weak interference-resistance,etc.Aiming at this,a comprehensive energy-saving optimization model of asynchronous motor for voltage regulation based on static synchronous compensator(STATCOM)is put forward.By analyzing the working principle and operation performance of static synchronous compensator regulating voltage,a new energy-efficient optimization method for asynchronous motor is proposed based on the voltage regulator model to achieve soft start,continuous dynamic reactive power compensation and the terminal voltage stability control.The multi-objective optimal operation of asynchronous motor is realized by controlling the inverter to adjust the reactive current dynamically.The strategy reduces the influence of starting current and grid voltage by soft starting,and realizes the function of reactive power compensation and terminal voltage stabilization.The effectiveness and superiority of the proposed model is verified by the simulation analysis and the results of comparison with the motor started directly. 展开更多
关键词 Asynchronous motor direct starting static synchronous compensator(STATCOM) energy-saving optimization
下载PDF
Addressing Frequency Control Challenges in Future Low-Inertia Power Systems:A Great Britain Perspective 被引量:2
4
作者 Qiteng Hong Md Asif Uddin Khan +3 位作者 Callum Henderson AgustíEgea-Àlvarez Dimitrios Tzelepis Campbell Booth 《Engineering》 SCIE EI 2021年第8期1057-1063,共7页
The ambitious global targets on decarbonization present the need for massive integration of renewable generation in power systems,resulting in a significant decrease in the system inertia.In addition to the reduction ... The ambitious global targets on decarbonization present the need for massive integration of renewable generation in power systems,resulting in a significant decrease in the system inertia.In addition to the reduction in system inertia,the transmission system in Great Britain(GB)faces some unique challenges owing to its relatively small capacity,while being decoupled from other transmission systems and with the renewable resources largely non-uniformly distributed across the system.This paper presents opinions and insights on the challenges associated with frequency control in a low-inertia system and the potential solutions from a GB perspective.In this paper,we focus on three main techniques that act over different time scales:synchronous condensers,inertia emulation,and fast frequency response.We evaluate their relative advantages and limitations with learnings from recent research and development projects in GB,along with the opinions on their roles in addressing the frequency control challenges in future low-inertia systems. 展开更多
关键词 Fast frequency control Inertia emulation synchronous compensation Low-inertia systems
下载PDF
Research of Magnetic Bias Control System Based on STATCOM 被引量:1
5
作者 Zongqiang Zheng 《World Journal of Engineering and Technology》 2016年第3期9-15,共7页
As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This... As the most important style of reactive power compensation system, the research and design control system of static synchronous compensator (STATCOM) is an important aspect of keeping stable and normal operation. This paper analyzes the influences of bias magnetic to STATCOM, and proposes an effective magnetic bias control method and program realization, so reduced to producing two harmonics. It improves the quality and reliability of STATCOM output voltage;Finally, the tests are conducted in the ±500 kVar STATCOM, and the results show the validity and necessity of this compensation method. 展开更多
关键词 Static synchronous Compensator (STATCOM) Magnetic Bias Control Harmonic Suppression
下载PDF
Artificial Neural Network in Harmonic Reduction of STATCOM 被引量:1
6
作者 LiHongmei LiZhenran ZhengPeiying 《Electricity》 2005年第1期34-37,共4页
To eliminate harmonic pollution incurred from the static synchronous compensator(STATCOM), a method of applying artificial neural network is presented. When PWM wave is formed based on the harmonic suppression theory,... To eliminate harmonic pollution incurred from the static synchronous compensator(STATCOM), a method of applying artificial neural network is presented. When PWM wave is formed based on the harmonic suppression theory, a concave is set on certain angle of the square wave to suppress unnecessary harmonics, by timely and on-line determining the chopping angle corresponding to respective harmonics through artificial neural network, i.e. by setting the position of concave to eliminate corresponding harmonics, the harmonic component on output voltage of the inverter can be improved. To conclude through computer simulation test, the perfect control effect has been proved. 展开更多
关键词 static synchronous compensator (STATCOM) artificial neural network(ANN) HARMONICS
下载PDF
Fault Location Method for STATCOM Connected Transmission Lines Using CCM 被引量:1
7
作者 R. Ilango T. Sree Renga Raja 《Circuits and Systems》 2016年第10期3131-3141,共12页
Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to loca... Determining the fault location using conventional impedance based distance relay in the presence of FACTS controllers is a challenging task in a transmission line. A new distance protection method is developed to locate the fault in a transmission line compensated with STATCOM with simple calculations. The proposed protection method considers the STATCOM injected/absorbed current to correct the fault loop apparent impedance and accordingly calculates the actual distance to the fault location. The comprehensive equations needed for apparent impedance calculation are also outlined and the performance is evaluated and tested with a typical 400 KV transmission system for different fault types and locations using MATLAB/SIMULINK software. The evaluation results indicate that the new protection method effectively estimates the exact fault location by mitigating the impact of STATCOM on distance relay performance with error less than 0.3%. 展开更多
关键词 Distance Relay Fault Location Flexible AC Transmission Systems (FACTS) Power System Protection Static synchronous Compensator (STATCOM)
下载PDF
Enhancement of Distributed Generation by Using Custom Power Device
8
作者 Kishor V.Bhadane M.S.Ballal R.M.Moharil 《Journal of Electronic Science and Technology》 CAS CSCD 2015年第3期246-254,共9页
Wind energy (WE) has become immensely popular for distributed generation (DG). This case presents the monitoring, modeling, control, and analysis of the two-level three-phase WE based DG system where the electric ... Wind energy (WE) has become immensely popular for distributed generation (DG). This case presents the monitoring, modeling, control, and analysis of the two-level three-phase WE based DG system where the electric grid interfacing custom power device (CPD) is controlled to perform the smart exchanging of electric power as per the Indian grid code. WE is connected to DC link of CPD for the grid integration purpose. The CPD based distributed static compensator, i.e. the distributed static synchronous compensator (DSTATCOM), is utilized for injecting the wind power to the point of common coupling (PCC) and also acts against the reactive power demand. The novel indirect current control scheme of DSTATCOM regulates the power import and export between the WE and the electric grid system. It also acts as a compensator and performs both the key features simultaneously. Hence, the penetration of additional generated WE power to the grid is increased by 20% to 25%. The burden of reactive power compensation from grid is reduced by DSTATCOM. The modeling and simulation are done in MATLAB. The results are validated and verified. 展开更多
关键词 Custom power device distributed generation (DG) distributed static synchronous compensator (DSTATCOM) indirect current control scheme reactive power
下载PDF
Comparison and Performance Analysis of FACTs Controller in System Stability
9
作者 Karthikeyan Ramasamy 《Circuits and Systems》 2016年第10期2948-2958,共11页
In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of... In large inter connected power systems, inter-area oscillations are turned to be a severe problem. Hence inter-area oscillations cause severe problems like damage to generators, reduce the power transfer capability of transmission lines, increase wear and tear on network components, increase line losses etc. This paper is to maintain the stability of system by damping inter-area oscillations. Implementation of new equipment consists of high power electronics based technologies such as FACTs and proper controller design has become an essential to provide better damping performance than Power System Stabilizer (PSS). With development of Wide Area Measurement System (WAMS), remote signals have become as feedback signals to design Wide Area Damping Controller (WADC) for FACTs devices. In this work, POD is applied to both SVC and SSSC. Simulation studies are carried out in Power System Analysis Toolbox (PSAT) environment to evaluate the effectiveness of the FACTs controller in a large area power system. Results show that extensive analysis of FACTs controller for improving stability of system. 展开更多
关键词 Power System Stabilizer Wide-Area Measurement System Wide-Area Damping Controller Static VAR Compensator Flexible AC Transmission System Power Oscillation Damper Static synchronous Series Compensator
下载PDF
Stability enhancement of wind energy integrated hybrid system with the help of static synchronous compensator and symbiosis organisms search algorithm 被引量:11
10
作者 Pabitra Kumar Guchhait Abhik Banerjee 《Protection and Control of Modern Power Systems》 2020年第1期153-165,共13页
Conventional proportional integral derivative(PID)controllers are being used in the industries for control purposes.It is very simple in design and low in cost but it has less capability to minimize the low frequency ... Conventional proportional integral derivative(PID)controllers are being used in the industries for control purposes.It is very simple in design and low in cost but it has less capability to minimize the low frequency noises of the systems.Therefore,in this study,a low pass filter has been introduced with the derivative input of the PID controller to minimize the noises and to improve the transient stability of the system.This paper focuses upon the stability improvement of a wind-diesel hybrid power system model(HPSM)using a static synchronous compensator(STATCOM)along with a secondary PID controller with derivative filter(PIDF).Under any load disturbances,the reactive power mismatch occurs in the HPSM that affects the system transient stability.STATCOM with PIDF controller is used to provide reactive power support and to improve stability of the HPSM.The controller parameters are also optimized by using soft computing technique for performance improvement.This paper proposes the effectiveness of symbiosis organisms search algorithm for optimization purpose.Binary coded genetic algorithm and gravitational search algorithm are used for the sake of comparison. 展开更多
关键词 Binary coded genetic algorithm Gravitational search algorithm Hybrid power system model PID controller with derivative filter Static synchronous compensator Symbiosis organisms search algorithm Transient stability
原文传递
Robust design of static synchronous series compensator-based stabilizer for damping inter-area oscillations using quadratic mathematical programming 被引量:1
11
作者 Mahmoud Reza SHAKARAMI Ahad KAZEMI 《Journal of Zhejiang University-Science C(Computers and Electronics)》 SCIE EI 2010年第4期296-306,共11页
This paper presents a procedure for designing a supplementary damping stabilizer for a static synchronous series compensator(SSSC) in multi-machine power systems.The objective is to shift the lightly damped inter-area... This paper presents a procedure for designing a supplementary damping stabilizer for a static synchronous series compensator(SSSC) in multi-machine power systems.The objective is to shift the lightly damped inter-area modes toward the prescribed stability region.A lead-lag stabilizer is used to demonstrate this technique,in which a particular measure of stabilizer gain is considered as an objective function.Constraints of the problem for phase-lead and lag structures are derived.The objective function with the constraints is formed as a quadratic mathematical programming problem.For robust design,the parameters of the stabilizer are calculated under various operating conditions.Two types of SSSC-based stabilizer have been presented and designed.Numerical results including eigenvalue analysis and the nonlinear simulations on the 4-and 50-machine power systems are pre-sented to show the effectiveness of the proposed method. 展开更多
关键词 Inter-area oscillations Static synchronous series compensator(SSSC) Damping stabilizer Robust design Quadratic mathematical programming
原文传递
Improved Hybrid Reactive Power Compensation System Based on FC and STATCOM and Its Control Method 被引量:1
12
作者 Xiheng Liang Fei Jiang +4 位作者 Xing Peng Liansong Xiong Yongbin Jiang Samir Gautam Zhichang Li 《Chinese Journal of Electrical Engineering》 CSCD 2022年第2期29-41,共13页
The purpose of this study is to solve the main problems in distribution networks,including increased line loss and reduced power supply quality caused by insufficient capacitive reactive power.To reduce the capacity,v... The purpose of this study is to solve the main problems in distribution networks,including increased line loss and reduced power supply quality caused by insufficient capacitive reactive power.To reduce the capacity,voltage,and current stress of an active module of a compensation device and improve the cost performance of the device,an improved hybrid reactive power compensation system based on a fixed capacitor(FC)and a static synchronous compensator(STATCOM)is proposed.The topological structure and basic operating principle of the proposed reactive power compensation system are introduced.In addition,from the perspectives of output voltage,current,power,loss of the active part,and system compensation cost,the performances of the proposed reactive compensator and the inductively coupled STATCOM(L-STATCOM)are compared and analyzed.Furthermore,the key parameters of the proposed system are designed,and the joint optimization control strategy of the FC and STATCOM is studied.The correctness and effectiveness of the proposed topology structure and control method are verified by simulations. 展开更多
关键词 Static synchronous compensator hybrid topology reactive power compensation fixed capacitor
原文传递
Analysis on Circulating Current and Split Capacitor Voltage Balance for Modular Multilevel Converter Based Three-phase Four-wire Split Capacitor DSTATCOM 被引量:1
13
作者 Lei Lin Jialu He Chen Xu 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第3期657-667,共11页
We propose a modular multilevel converter(MMC)based three-phase four-wire(3P4W)split capacitor distribution static synchronous compensator(DSTATCOM),aiming at compensating unbalanced and reactive load currents.Due to ... We propose a modular multilevel converter(MMC)based three-phase four-wire(3P4W)split capacitor distribution static synchronous compensator(DSTATCOM),aiming at compensating unbalanced and reactive load currents.Due to the zero-sequence current compensation,the circulating current char-acteristics of 3P4W MMC-DSTATCOM are different from conventional MMCs.Moreover,the distinct working principle of IMMC would affect the features of split capacitor voltage.The decoupled positive-,negative-and zero-sequence second-order and DC components of the circulating current are deduced explicitly.Two proportional-integral controllers with dual dq transformation are employed to suppress the positive-and negative-sequence components of second-order circulating current,while quasi proportional-resonance controller is designed to eliminate the zero-sequence component.Besides,the phenomenon of the unbalanced split capacitor voltages is revealed,and fast-tracking balancing method by controlling zero-sequence current flowing through the split capacitors is provided.Digital simulation results verify the accuracy of the analysis and the feasibility of the suppression methods. 展开更多
关键词 Circulating current modular multilevel converter(MMC) distribution static synchronous compensator(DSTATCOM) split capacitor three-phase four-wire(3P4W)
原文传递
Inter-cluster Voltage Balancing Control of Modular Multilevel Cascaded Converter Under Unbalanced Grid Voltage 被引量:1
14
作者 Oghenewvogaga Oghorada Li Zhang +2 位作者 Ayodele Esan Dickson Egbune Julius Uwagboe 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第2期515-523,共9页
This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(ST... This paper presents a novel inter-cluster direct current(DC)capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter(MMCC)-based static synchronous compensator(STATCOM)under unbalanced grid voltage.The negative-sequence component of grid voltage at the point of common connection(PCC)causes unbalanced active power flow in the phase limbs of converter.This leads to the imbalance of DC voltages of the sub-module capacitors across the MMCC phases,and consequently,the malfunction of converter.The proposed solution is to inject both negative-sequence current(NSC)and zero-sequence voltage(ZSV)into the phase limbs of MMCC.A quantification factor Qf is used to achieve the sharing of inter-cluster active pow-er between the NSC and ZSV injection methods.Accurate determination of the quantification factor has been presented.In addition to maintaining the DC voltages of sub-module capacitor across the MMCC phases balanced,it also prevents the overcurrent and overvoltage of converter by injecting NSC and ZSV with the right proportion.The control scheme is validated on a 3.54 kV 1.2 MVA power system using MMCC-based STATCOM with 3-level bridge cells as sub-modules.The results show that the proposed scheme provides superior effectiveness in eliminating the voltage imbalance of DC capacitor in the phase limb while maintaining low voltage and current ratings. 展开更多
关键词 Low-voltage ride through(LVRT) single-star bridge converter(SSBC) static synchronous compensator(STATCOM) modular multilevel cascaded converter(MMCC) quantification factor
原文传递
Inter-cluster voltage balancing control of a delta connected modular multilevel cascaded converter under unbalanced grid voltage 被引量:3
15
作者 Oghenewvogaga J.K.Oghorada Li Zhang +2 位作者 Huang Han Ayodele B.Esan Mingxuan Mao 《Protection and Control of Modern Power Systems》 2021年第1期289-299,共11页
A new inter-cluster DC capacitor voltage balancing scheme for a delta connected modular multilevel cascaded converter (MMCC)-based static synchronous compensator (STATCOM) is presented. A detailed power flow analysis ... A new inter-cluster DC capacitor voltage balancing scheme for a delta connected modular multilevel cascaded converter (MMCC)-based static synchronous compensator (STATCOM) is presented. A detailed power flow analysis of applying negative sequence current (NSC) and zero-sequence current (ZSC) injection methods in addressing the issue of inter-cluster DC voltage imbalance under unbalance grid voltage is carried out. A control scheme is proposed which integrates both inter-cluster methods using a quantification factor QF. This is used to achieve the sharing of the inter-cluster active power between the NSC and ZSC injection methods. An accurate method of determining the quantification factor is also presented. The proposed method offers better sub-module DC capacitor voltage balancing and prevents converter overcurrent. The influence of unbalanced grid voltage on the delta connected MMCC-based STATCOM rating using this integrated cluster balancing technique is investigated. The control scheme is verified with a 5 kV 1.2MVA MMCC-STATCOM using 3-level bridge sub-modules, and the results show the advantages of the proposed method over other inter-cluster methods. 展开更多
关键词 Low voltage ride through(LVRT) Single delta bridge converter(SDBC) Static synchronous compensator(STATCOM) Quantification factor
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部