Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in...Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents.展开更多
Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.V...Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility.Barium sulfate and physiological saline were used as contrast agents for the blood vessels.Blood vessels of <Φ20μm could be detected by replacing resident blood with physiological saline or barium sulfate.An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image.It is demonstrated that selective angiography based on phase contrast X-ray imaging,with a physiological material of low Z elements (such as saline) being the contrast agent,is a viable imaging strategy.Further efforts will be focused on using the technique to image tumor angiogenesis.展开更多
An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas ...An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas made to enlarge the X-ray beam section and consequently larger samples could be imaged. In-line setup was em-ployed for experiments. Results on a series of samples were given and soft-tissue details of less than 50 μm inside afresh goldfish were obtained. Diagnosis of tumor in its early stage was also investigated taking SD rats as the model.Tumor at the size of ~ 100μm was observed. Potential of this technique in clinic diagnosis was discussed.展开更多
Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refr...Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse- projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensionak phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method.展开更多
A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a stro...A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified.展开更多
X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping informa...X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.展开更多
In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehens...In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging.展开更多
In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of...In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging.展开更多
A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1...A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1).This is part of the Phase II construction project of the SSRF.The BL13HB is dedicated to 2D and 3D static and dynamic X-ray imaging,with a field of view of up to 48.5 mm×5.2 mm and spatial resolution as high as 0.8μm.A super-bending magnet is used as the X-ray source in BL13HB,which has a maximum magnetic field of 2.293 T.The energy range of monochromatic X-ray photons from a double-multiplayer monochromator was 8–40 keV,and the white beam mode was provided on the beamline for dynamic X-ray imaging and dynamic X-ray micro-CT.While maintaining the previous experimental setup of BL13W1,new equipment was added to the beamline experimental station.The beamline is equipped with different sets of X-ray imaging detectors for several experimental methods such as micro-CT,dynamic micro-CT,and pair distribution function.The experimental station of BL13HB is designed specifically for various in situ dynamic experiments,and BL13HB has been open to users since June 2021.展开更多
We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images ar...We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images are subtracted to obtain the target element: one is at the absorption edge of the target element and the other is near the absorption edge. The x-ray exposure required by this method is expected to be significantly lower than that of conventional absorption-based x-ray elemental imaging methods. Numerical calculations confirm the advantages of this highly efficient imaging method.展开更多
A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imagin...A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imaging and the improved image contrast.By using this theory,several key parameters of phase contrast imaging can be predicted,for instance,the fringe visibility and period,and the conversion condition from the differential phase imaging(DPI)to the phase difference imaging(PDI).Additionally,numerical simulations are performed with certain x-ray optical components and imaging geometry.Comparison with the available experimental measurement[Appl.Phys.Lett.113063105(2018)]demonstrates the accuracy of this developed quantitative analysis method of x-ray phase-sensitive microscope imaging.展开更多
With the spatial coherence of X-rays and high flux and brightness of the 3rd generation synchrotron radiation facility,X-ray phase contrast microscopy(XPCM)at Shanghai Synchrotron Radiation Facility(SSRF)can provide h...With the spatial coherence of X-rays and high flux and brightness of the 3rd generation synchrotron radiation facility,X-ray phase contrast microscopy(XPCM)at Shanghai Synchrotron Radiation Facility(SSRF)can provide high resolution dynamic imaging of low electron density materials in principle.In this paper,we investigated the cavitation and water-refilling processes in rice and bamboo leaves utilizing XPCM at SSRF.The occurrence of xylem cavitation was recorded in vivo.The study also revealed that under different dehydration conditions,cavitation occurs in different degrees,and therefore,the refilling process is different.The results demonstrate that SSRF can provide high enough fluxes to study dynamic processes in plants in real-time,and XPCM is expected to be a promising method to reveal the mechanisms of cavitation and its repair in plants nondestructively.展开更多
The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray di...The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray diffraction and imaging using white and monochromatic light.The main scientific objectives of ultrahard X-ray beamlines are focused on two research areas.One is the study of the structural properties of Earth’s interior and new materials under extreme high-temperature and high-pressure conditions,and the other is the characterization of materials and processes in near-real service environments.The beamline utilizes a superconducting wiggler as the light source,with two diamond windows and SiC discs to filter out low-energy light(primarily below 30 keV)and a Cu filter assembly to control the thermal load entering the subsequent optical components.The beamline is equipped with dual monochromators.The first was a meridional bending Laue monochromator cooled by liquid nitrogen,achieving a full-energy coverage of 30-162 keV.The second was a sagittal bending Laue monochromator installed in an external building,providing a focused beam in the horizontal direction with an energy range of 60-120 keV.There were four experimental hutches:two large-volume press experimental hutches(LVP1 and LVP2)and two engineering material experimental hutches(ENG1 and ENG2).Each hutch was equipped with various near-real service conditions to satisfy different requirements.For example,LVP1 and LVP2 were equipped with a 200-ton DDIA press and a 2000-ton dual-mode(DDIA and Kawai)press,respectively.ENG1 and ENG2 provide in situ tensile,creep,and fatigue tests as well as high-temperature conditions.Since June 2023,the BL12SW has been in trial operation.It is expected to officially open to users by early 2024.展开更多
Diffraction-enhanced imaging (DEI) is a powerful phase-sensitive technique that provides higher spatial resolution and supercontrast of weakly absorbing objects than conventional radiography. It derives contrast fro...Diffraction-enhanced imaging (DEI) is a powerful phase-sensitive technique that provides higher spatial resolution and supercontrast of weakly absorbing objects than conventional radiography. It derives contrast from the X-ray absorption, refraction, and ultra-small-angle X-ray scattering (USAXS) properties of an object. The separation of different-contrast contributions from images is an important issue for the potential application of DEI. In this paper, an improved DEI (IDEI) method is proposed based on the Gaussian curve fitting of the rocking curve (RC). Utilizing only three input images, the IDEI method can accurately separate the absorption, refraction, and USAXS contrasts produced by the object. The IDEI method can therefore be viewed as an improvement to the extended DEI (EDEI) method. In contrast, the IDEI method can circumvent the limitations of the EDEI method well since it does not impose a Taylor approximation on the RC. Additionally, analysis of the IDEI model errors is performed to further investigate the factors that lead to the image artifacts, and finally validation studies are conducted using computer simulation and synchrotron experimental data.展开更多
Dual phase grating x-ray interferometry is compatible with common imaging detectors,and abandons the use of an absorption analyzer grating to reduce the radiation dose.When using x-ray tubes,an absorbing source gratin...Dual phase grating x-ray interferometry is compatible with common imaging detectors,and abandons the use of an absorption analyzer grating to reduce the radiation dose.When using x-ray tubes,an absorbing source grating must be introduced into the dual phase grating interferometer.In order to attain a high fringe visibility,in this work we conduct a quantitative coherence analysis of dual phase grating interferometry to find how the source grating affects the fringe visibility.Theoretical analysis shows that with the generalized Lau condition satisfied,the fringe visibility is influenced by the duty cycle of the source grating and the transmission through the grating bar.And the influence of the source grating profile on the fringe visibility is independent of the phase grating type.Numerical results illustrate that the maximum achievable fringe visibility decreases significantly with increasing transmission in the grating bar.Under a given transmission,one can always find an optimal duty cycle to maximize the fringe visibility.These results can be used as general guidelines for designing and optimizing dual phase grating x-ray interferometers for potential applications.展开更多
Non-interferometric X-ray quantitative phase imaging(XQPI),much simpler than the interferometric scheme,has provided high-resolution and reliable phase-contrast images.We report on implementing the volumetric XQPI ima...Non-interferometric X-ray quantitative phase imaging(XQPI),much simpler than the interferometric scheme,has provided high-resolution and reliable phase-contrast images.We report on implementing the volumetric XQPI images using concurrent-bidirectional scanning of the orthogonal plane on the optical axis of the Foucault differential filter;we then extracted data in conjunction with the transport-intensity equation.The volumetric image of the laminate microstructure of the gills of a fish was successfully reconstructed to demonstrate our XQPI method.The method can perform 3D rendering without any rotational motion for laterally extended objects by manipulating incoherent X-rays using the pinhole array.展开更多
Two algorithms for the phase retrieval of hard X-ray in-line phase contrast imaging are presented. One is referred to as Iterative Angular Spectrum Algorithm (IASA) and the other is a hybrid algorithm that combines IA...Two algorithms for the phase retrieval of hard X-ray in-line phase contrast imaging are presented. One is referred to as Iterative Angular Spectrum Algorithm (IASA) and the other is a hybrid algorithm that combines IASA with TIE (transport of intensity equation). The calculations of the algorithms are based on free space propagation of the angular spectrum. The new approaches are demonstrated with numerical simulations. Comparisons with other phase retrieval algorithms are also performed. It is shown that the phase retrieval method combining the IASA and TIE is a promising technique for the application of hard X-ray phase contrast imaging.展开更多
Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different...Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging.展开更多
Plate-like Fe-rich intermetallic phases directly influence the mechanical properties of recycled Al alloys;thus, many attempts have been made to modify the morphology of these phases. Through synchrotron X-ray imaging...Plate-like Fe-rich intermetallic phases directly influence the mechanical properties of recycled Al alloys;thus, many attempts have been made to modify the morphology of these phases. Through synchrotron X-ray imaging and electron microscopy, the underlying nucleation and growth mechanisms of Fe-rich phases during the solidification of Al-5 Ti-1 B-modified Al-2 Fe alloys were revealed in this study. The results showed that the Al-5 Ti-1 B grain refiner as well as the applied pressure both resulted in reduction of the size and number of primary Al_(3)Fe phases and promoted the formation of eutectic Al_(6)Fe phases.The tomography results demonstrated that Al-5 Ti-1 B changed the three-dimensional(3 D) morphology of primary Fe-rich phases from rod-like to branched plate-like, while a reduction in their thickness and size was also observed. This was attributed to the fact that Ti-containing solutes in the melts inhibit the diffusion of Fe atoms and the Al_(3)Fe twins produce re-entrant corner on the twin boundaries along the growth direction. Moreover, the TiB_(2) provides possible nucleation sites for Al_6Fe phases. The nucleation mechanism of Fe-rich phases is discussed in terms of experimental observations and crystallography calculations. The decrease in the lattice mismatch between TiB_(2) and Al_(6)Fe phases was suggested, which promoted the transformation of Al_(3)Fe to Al_(6)Fe phases.展开更多
The manufacturing of additives with projection micro litho stereo exposure(PμLSE)has provided an opportunity for the fabrication of metastructures with complex microstructures at micro-nano resolutions.However,the pe...The manufacturing of additives with projection micro litho stereo exposure(PμLSE)has provided an opportunity for the fabrication of metastructures with complex microstructures at micro-nano resolutions.However,the performance evaluation of as-fabricated metastructures is challenging.The benefit of synchrotron radiation-based 3 D imaging techniques and advanced image processing methods makes it is feasible to study fabrication defects and damage processes of micro-nanoscale bodycentered cubic(BCC)lattices manufactured with PμLSE.First,synchrotron radiation technology is used to capture the structural features inside the micro-lattice samples.Subsequently,several types of statistical defects-based image finite element models are adopted to analyze the failure process of the structure under compression loading.Finally,comparisons between in situ experiments and numerical simulation results are performed for verification.The method of the combined non-destructive testing of synchrotron radiation and image finite element technology provides a robust technique for evaluating the performances of additive-manufactured micro-lattice with complex microstructures.展开更多
基金Supported by National Natural Science Foundation of China (10275087)Shanghai Optic Science Fund (022261023)Shanghai Natural Science Fund (02ZF14116)
文摘Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents.
基金Supported by National Basic Research Program of China (973 Program Grant No.2010CB834305)
文摘Imaging blood vessels is of importance for determining the vascular distribution of organs and tumors.Phase-contrast X-ray imaging can reveal the vessels in much more detail than conventional X-ray absorption method.Visualizing murine liver microvasculature ex vivo with phase-contrast X-ray imaging was performed at Shanghai Synchrotron Radiation Facility.Barium sulfate and physiological saline were used as contrast agents for the blood vessels.Blood vessels of <Φ20μm could be detected by replacing resident blood with physiological saline or barium sulfate.An entire branch of the portal vein (from the main axial portal vein to the ninth generation of branching) could be captured in a single phase-contrast image.It is demonstrated that selective angiography based on phase contrast X-ray imaging,with a physiological material of low Z elements (such as saline) being the contrast agent,is a viable imaging strategy.Further efforts will be focused on using the technique to image tumor angiogenesis.
基金National Natural Science Foundation of China(No.10275087)Shanghai Foundation on Development of Science and Technology(No.022261023) Shanghai Foundation for Natural Science(No.02ZF14116)
文摘An experimental study on nondestructive X-ray imaging of inner structure of soft tissues in phase con-trast has been conducted with Beijing Synchrotron Radiation Facility (BSRF). Modification to the beamline setupwas made to enlarge the X-ray beam section and consequently larger samples could be imaged. In-line setup was em-ployed for experiments. Results on a series of samples were given and soft-tissue details of less than 50 μm inside afresh goldfish were obtained. Diagnosis of tumor in its early stage was also investigated taking SD rats as the model.Tumor at the size of ~ 100μm was observed. Potential of this technique in clinic diagnosis was discussed.
基金Project supported by the Knowledge Innovation Program of the Chinese Academy of Sciences (Grant No.KJCX2-YW-N42)the Key Project of the National Natural Science Foundation of China (Grant No.10734070)+3 种基金the National Natural Science Foundation of China (Grant No.11205157)the National Basic Research Program of China (Grant Nos. 2009CB930804 and 2012CB825800)the Fundamental Research Funds for the Central Universities,China (Grant No. WK2310000021)the China Postdoctoral Science Foundation (Grant No. 2011M501064)
文摘Grating-based X-ray phase contrast imaging has been demonstrated to he an extremely powerful phase-sensitive imaging technique. By using two-dimensional (2D) gratings, the observable contrast is extended to two refraction directions. Recently, we have developed a novel reverse-projection (RP) method, which is capable of retrieving the object information efficiently with one-dimensional (1D) grating-based phase contrast imaging. In this contribution, we present its extension to the 2D grating-based X-ray phase contrast imaging, named the two-dimensional reverse- projection (2D-RP) method, for information retrieval. The method takes into account the nonlinear contributions of two refraction directions and allows the retrieval of the absorption, the horizontal and the vertical refraction images. The obtained information can be used for the reconstruction of the three-dimensionak phase gradient field, and for an improved phase map retrieval and reconstruction. Numerical experiments are carried out, and the results confirm the validity of the 2D-RP method.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61101175,61571305,and 61227802)
文摘A fast and simple method to extract phase-contrast images from interferograms is proposed, and its effectiveness is demonstrated through simulation and experiment. For x-ray differential phase contrast imaging, a strong attenuation signal acts as an overwhelming background intensity that obscures the weak phase signal so that no obvious phase-gradient information is detectable in the raw image. By subtracting one interferogram from another, chosen at particular intervals,the phase signal can be isolated and magnified.
基金supported by the National Natural Science Foundation of China(Grant Nos.11275204,11475175,and 11405175)the China Postdoctoral Science Foundation(Grant No.2017M612097)the Fundamental Research Funds for the Central Universities(Grant No.WK2310000065)
文摘X-ray grating interferometer has attracted widely attention in the past years due to its capability in achieving x-ray phase contrast imaging with low brilliance source. However, the widely used phase stepping information extraction method reduces system stability and prolongs data acquisition time by several times compared with conventional x-ray absorption- based imaging. The mechanical stepping can be avoided by using a staggered grating, but at the cost of low vertical spatial resolution. In this paper, employing a modified staggered grating and the angular signal radiography, we proposed a single-shot grating-based x-ray differential phase contrast imaging with decent vertical spatial resolution. The theoretical framework was deduced and proved by numerical experiments. Absorption, phase, and scattering computed tomography can be performed without phase stepping. Therefore, we believe this fast and highly stable imaging method with decent resolution would be widely applied in x-ray grating-based phase contrast imaging.
基金Project supported by the National Natural Science Foundation of China (Grant No 10475044).
文摘In-line x-ray phase contrast imaging has attracted much attention due to two major advantages: its effectiveness in imaging weakly absorbing materials, and the simplicity of its facilities. In this paper a comprehensive theory based on Wigner distribution developed by Wu and Liu [Med. Phys. 31 2378-2384 (2004)] is reviewed. The influence of x-ray source and detector on the image is discussed. Experiments using a microfocus x-ray source and a CCD detector are conducted, which show the role of two key factors on imaging: the tube voltage and tube current. High tube current and moderate tube voltage are suggested for imaging.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11074172 and 11674232)the National Key Basic Research Program,China(Grant No.2012CB825804)the National Special Foundation for Major Science Instrument,China(Grant No.61227802)
文摘In theory, we find that the actual function of the analyzer grating in the Talbot–Lau interferometer is segmenting the self-images of the phase grating and choosing integral areas, which make sure that each period of self-images in one detector pixel contributes the same signal to the detector. Furthermore, in the case of the lack of an analyzer grating, the shifting curves are still existent in theory as long as the number of fringes is non-integral in a detector pixel, which is a sufficient condition for creating shifting curve. The sufficient condition is available for not only the Talbot–Lau interferometer and the inverse geometry of Talbot–Lau interferometer, but also the x-ray phase contrast imaging system based on geometrical optics. In practical applications, we propose a method to improve the performances of the existing systems by employing the sufficient condition. This method can shorten the system length, is applicable to large period gratings, and can use the detectors with large pixels and large field of view. In addition, the experimental arrangement can be simplified due to the lack of an analyzer grating. In order to improve detection sensitivity and resolution, we also give an optimal fringe period.We believe that the theory and method proposed here is a step forward for x-ray phase contrast imaging.
基金supported by the National Major Scientific Instruments and Equipment Development Project of China(No.11627901)the National Key Research and Development Program of China(Nos.2021YFF0701202 and 2021YFA1600703)the National Natural Science Foundation of China(Nos.U1932205,12275343)。
文摘A new X-ray imaging and biomedical application beamline(BL13HB)has been implemented at the Shanghai Radiation Synchrotron Facility(SSRF)as an upgrade to the old X-ray imaging and biomedical application beamline(BL13W1).This is part of the Phase II construction project of the SSRF.The BL13HB is dedicated to 2D and 3D static and dynamic X-ray imaging,with a field of view of up to 48.5 mm×5.2 mm and spatial resolution as high as 0.8μm.A super-bending magnet is used as the X-ray source in BL13HB,which has a maximum magnetic field of 2.293 T.The energy range of monochromatic X-ray photons from a double-multiplayer monochromator was 8–40 keV,and the white beam mode was provided on the beamline for dynamic X-ray imaging and dynamic X-ray micro-CT.While maintaining the previous experimental setup of BL13W1,new equipment was added to the beamline experimental station.The beamline is equipped with different sets of X-ray imaging detectors for several experimental methods such as micro-CT,dynamic micro-CT,and pair distribution function.The experimental station of BL13HB is designed specifically for various in situ dynamic experiments,and BL13HB has been open to users since June 2021.
基金supported by the National Basic Research Program of China(Grant No.2012CB825801)the National Natural Science Foundation of China(Grant Nos.11505188,and 11305173)
文摘We develop an element-specific x-ray microscopy method by using Zernike phase contrast imaging near absorption edges, where a real part of refractive index changes abruptly. In this method two phase contrast images are subtracted to obtain the target element: one is at the absorption edge of the target element and the other is near the absorption edge. The x-ray exposure required by this method is expected to be significantly lower than that of conventional absorption-based x-ray elemental imaging methods. Numerical calculations confirm the advantages of this highly efficient imaging method.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.12027812 and 11804356)the Youth Innovation Promotion Association of the Chinese Academy of Sciences(Grant No.2021362).
文摘A general theoretical framework is presented to explain the formation of the phase signal in an x-ray microscope integrated with a grating interferometer,which simultaneously enables the high spatial resolution imaging and the improved image contrast.By using this theory,several key parameters of phase contrast imaging can be predicted,for instance,the fringe visibility and period,and the conversion condition from the differential phase imaging(DPI)to the phase difference imaging(PDI).Additionally,numerical simulations are performed with certain x-ray optical components and imaging geometry.Comparison with the available experimental measurement[Appl.Phys.Lett.113063105(2018)]demonstrates the accuracy of this developed quantitative analysis method of x-ray phase-sensitive microscope imaging.
基金Supported by the National Natural Science Foundation of China(No.11105213)the State Key Development Program for Basic Research of China(No.2010CB834301)+1 种基金the External Cooperation Program of the Chinese Academy of Sciences(No.GJHZ09058)the Knowledge Innovation Program of the Chinese Academy of Sciences
文摘With the spatial coherence of X-rays and high flux and brightness of the 3rd generation synchrotron radiation facility,X-ray phase contrast microscopy(XPCM)at Shanghai Synchrotron Radiation Facility(SSRF)can provide high resolution dynamic imaging of low electron density materials in principle.In this paper,we investigated the cavitation and water-refilling processes in rice and bamboo leaves utilizing XPCM at SSRF.The occurrence of xylem cavitation was recorded in vivo.The study also revealed that under different dehydration conditions,cavitation occurs in different degrees,and therefore,the refilling process is different.The results demonstrate that SSRF can provide high enough fluxes to study dynamic processes in plants in real-time,and XPCM is expected to be a promising method to reveal the mechanisms of cavitation and its repair in plants nondestructively.
基金National Natural Science Foundation of China(Nos.12334010,42274121).
文摘The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray diffraction and imaging using white and monochromatic light.The main scientific objectives of ultrahard X-ray beamlines are focused on two research areas.One is the study of the structural properties of Earth’s interior and new materials under extreme high-temperature and high-pressure conditions,and the other is the characterization of materials and processes in near-real service environments.The beamline utilizes a superconducting wiggler as the light source,with two diamond windows and SiC discs to filter out low-energy light(primarily below 30 keV)and a Cu filter assembly to control the thermal load entering the subsequent optical components.The beamline is equipped with dual monochromators.The first was a meridional bending Laue monochromator cooled by liquid nitrogen,achieving a full-energy coverage of 30-162 keV.The second was a sagittal bending Laue monochromator installed in an external building,providing a focused beam in the horizontal direction with an energy range of 60-120 keV.There were four experimental hutches:two large-volume press experimental hutches(LVP1 and LVP2)and two engineering material experimental hutches(ENG1 and ENG2).Each hutch was equipped with various near-real service conditions to satisfy different requirements.For example,LVP1 and LVP2 were equipped with a 200-ton DDIA press and a 2000-ton dual-mode(DDIA and Kawai)press,respectively.ENG1 and ENG2 provide in situ tensile,creep,and fatigue tests as well as high-temperature conditions.Since June 2023,the BL12SW has been in trial operation.It is expected to officially open to users by early 2024.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.30900333 and 81371549)the WBE Liver Fibrosis Foundation,China(Grant No.CFHPC20131033)
文摘Diffraction-enhanced imaging (DEI) is a powerful phase-sensitive technique that provides higher spatial resolution and supercontrast of weakly absorbing objects than conventional radiography. It derives contrast from the X-ray absorption, refraction, and ultra-small-angle X-ray scattering (USAXS) properties of an object. The separation of different-contrast contributions from images is an important issue for the potential application of DEI. In this paper, an improved DEI (IDEI) method is proposed based on the Gaussian curve fitting of the rocking curve (RC). Utilizing only three input images, the IDEI method can accurately separate the absorption, refraction, and USAXS contrasts produced by the object. The IDEI method can therefore be viewed as an improvement to the extended DEI (EDEI) method. In contrast, the IDEI method can circumvent the limitations of the EDEI method well since it does not impose a Taylor approximation on the RC. Additionally, analysis of the IDEI model errors is performed to further investigate the factors that lead to the image artifacts, and finally validation studies are conducted using computer simulation and synchrotron experimental data.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.U1532113,11475170,and 11905041)the Fundamental Research Funds for the Central Universities,China(Grant No.PA2020GDKC0024)。
文摘Dual phase grating x-ray interferometry is compatible with common imaging detectors,and abandons the use of an absorption analyzer grating to reduce the radiation dose.When using x-ray tubes,an absorbing source grating must be introduced into the dual phase grating interferometer.In order to attain a high fringe visibility,in this work we conduct a quantitative coherence analysis of dual phase grating interferometry to find how the source grating affects the fringe visibility.Theoretical analysis shows that with the generalized Lau condition satisfied,the fringe visibility is influenced by the duty cycle of the source grating and the transmission through the grating bar.And the influence of the source grating profile on the fringe visibility is independent of the phase grating type.Numerical results illustrate that the maximum achievable fringe visibility decreases significantly with increasing transmission in the grating bar.Under a given transmission,one can always find an optimal duty cycle to maximize the fringe visibility.These results can be used as general guidelines for designing and optimizing dual phase grating x-ray interferometers for potential applications.
基金supported by the National Research Foundation of Korea(NRF)funded by the Korean government(MEST)(No.2021R1C1C200514).
文摘Non-interferometric X-ray quantitative phase imaging(XQPI),much simpler than the interferometric scheme,has provided high-resolution and reliable phase-contrast images.We report on implementing the volumetric XQPI images using concurrent-bidirectional scanning of the orthogonal plane on the optical axis of the Foucault differential filter;we then extracted data in conjunction with the transport-intensity equation.The volumetric image of the laminate microstructure of the gills of a fish was successfully reconstructed to demonstrate our XQPI method.The method can perform 3D rendering without any rotational motion for laterally extended objects by manipulating incoherent X-rays using the pinhole array.
基金supported by the National Natural Science Foundation of China(Grant No.60472107)the Natural Science Foundation of Guangdong Province(Grant Nos.04300862 and 04300864)Shenzhen Bureau of Science,Technology&Information(Grant No.200426).
文摘Two algorithms for the phase retrieval of hard X-ray in-line phase contrast imaging are presented. One is referred to as Iterative Angular Spectrum Algorithm (IASA) and the other is a hybrid algorithm that combines IASA with TIE (transport of intensity equation). The calculations of the algorithms are based on free space propagation of the angular spectrum. The new approaches are demonstrated with numerical simulations. Comparisons with other phase retrieval algorithms are also performed. It is shown that the phase retrieval method combining the IASA and TIE is a promising technique for the application of hard X-ray phase contrast imaging.
基金Supported by the National Natural Science Foundation of China (10475090)
文摘Employing the approximation theory based on refraction and the definition of the total pointspread-function of the imaging system, the variation in the edge contrast of simple model samples is discussed with different source-to-sample and sample-to-detector distances, which actually means different spatial resolutions of the imaging system. The experiments were carried out with the Beamline 4W1A imaging setup at the Beijing Synchrotron Radiation Facility for simple model and insect samples. The results show that to obtain clear phase-contrast images of biologic tissues for the X-ray in-line imaging setup, with determined parameters such as the size of the X-ray source, the pixel size of the detector and the fixed source-to-sample distance, there is a range of optimized sample-to-detector distances. The analysis method discussed in this article can be helpful in optimizing the setup of X-ray in-line phase-contrast imaging.
基金supported by the Team Project Natural Science Foundation of Guangdong Province(2015A030312003)Basic and Applied Basic Foundation of Guangdong Province(2019A1515110270)+2 种基金Research start-up funds of DGUT(GC300501138)Scientific Research Foundation of Advanced Talents(Innovation Team)DGUT(No.KCYCXPT2016004 and No.TDQN2019005)Natural Science Foundation of China(52074131)。
文摘Plate-like Fe-rich intermetallic phases directly influence the mechanical properties of recycled Al alloys;thus, many attempts have been made to modify the morphology of these phases. Through synchrotron X-ray imaging and electron microscopy, the underlying nucleation and growth mechanisms of Fe-rich phases during the solidification of Al-5 Ti-1 B-modified Al-2 Fe alloys were revealed in this study. The results showed that the Al-5 Ti-1 B grain refiner as well as the applied pressure both resulted in reduction of the size and number of primary Al_(3)Fe phases and promoted the formation of eutectic Al_(6)Fe phases.The tomography results demonstrated that Al-5 Ti-1 B changed the three-dimensional(3 D) morphology of primary Fe-rich phases from rod-like to branched plate-like, while a reduction in their thickness and size was also observed. This was attributed to the fact that Ti-containing solutes in the melts inhibit the diffusion of Fe atoms and the Al_(3)Fe twins produce re-entrant corner on the twin boundaries along the growth direction. Moreover, the TiB_(2) provides possible nucleation sites for Al_6Fe phases. The nucleation mechanism of Fe-rich phases is discussed in terms of experimental observations and crystallography calculations. The decrease in the lattice mismatch between TiB_(2) and Al_(6)Fe phases was suggested, which promoted the transformation of Al_(3)Fe to Al_(6)Fe phases.
基金supported by the National Natural Science Foundation of China(Grant Nos.11702023,and 11972081)。
文摘The manufacturing of additives with projection micro litho stereo exposure(PμLSE)has provided an opportunity for the fabrication of metastructures with complex microstructures at micro-nano resolutions.However,the performance evaluation of as-fabricated metastructures is challenging.The benefit of synchrotron radiation-based 3 D imaging techniques and advanced image processing methods makes it is feasible to study fabrication defects and damage processes of micro-nanoscale bodycentered cubic(BCC)lattices manufactured with PμLSE.First,synchrotron radiation technology is used to capture the structural features inside the micro-lattice samples.Subsequently,several types of statistical defects-based image finite element models are adopted to analyze the failure process of the structure under compression loading.Finally,comparisons between in situ experiments and numerical simulation results are performed for verification.The method of the combined non-destructive testing of synchrotron radiation and image finite element technology provides a robust technique for evaluating the performances of additive-manufactured micro-lattice with complex microstructures.