期刊文献+
共找到196篇文章
< 1 2 10 >
每页显示 20 50 100
Operando measurement of lattice deformation profiles of synchrotron radiation monochromator
1
作者 Yue Zhang Zhong-Liang Li +4 位作者 Shang-Yu Si Lian Xue Hong-Xin Luo Xiao-Wei Zhang Jun Hu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期8-19,共12页
This study presents a new method for characterizing the thermal lattice deformation of a monochromator with high precision under service conditions and first reports the operando measurements of nanoscale thermal latt... This study presents a new method for characterizing the thermal lattice deformation of a monochromator with high precision under service conditions and first reports the operando measurements of nanoscale thermal lattice deformation on a double-crystal monochromator at different incident powers.The nanoscale thermal lattice deformation of the monochromator first crystal was obtained by analyzing the intensity of the distorted DuMond diagrams.DuMond diagrams of the 333 diffraction index,sensitive to lattice deformation,were obtained directly using a 2D detector and an analyzer crystal orthogonal to the monochromator.With increasing incident power and power density,the maximum height of the lattice deformation increased from 3.2 to 18.5 nm,and the deformation coefficient of the maximum height increased from 1.1 to 3.2 nm/W.The maximum relative standard deviation was 4.2%,and the maximum standard deviation was 0.1 nm.Based on the measured thermal deformations,the flux saturation phenomenon and critical point for the linear operation of the monochromator were predicted with increasing incident power.This study provides a simple solution to the problem of the lower precision of synchrotron radiation monochromator characterizations compared to simulations. 展开更多
关键词 synchrotron radiation MONOCHROMATOR Lattice deformation x-ray dynamic diffraction
下载PDF
Polycapillary X-ray lens for the secondary focusing Beijing synchrotron radiation source 被引量:3
2
作者 李玉德 林晓燕 +4 位作者 刘世岗 何金龙 郭非 孙天希 刘鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第4期248-252,共5页
According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotr... According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results. 展开更多
关键词 Beijing synchrotron radiation facility polycapillary x-ray lens secondary focusing
下载PDF
L-shell x-ray fluorescence relative intensities for elements with 62≤Z≤83 at 18 keV and 23 keV by synchrotron radiation
3
作者 M Alqadi S AL-Humaidi +1 位作者 H Alkhateeb F Alzoubi 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第8期270-273,共4页
The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of... The relative intensities of L-subshell x-ray fluorescence(XRF)for elements with atomic numbers 62≤Z≤83 were measured at two excitation energies,18 keV and 23 keV,using a synchrotron radiation source at a beamline of the Synchrotron Light Center for Experimental Science and Applications in the Middle East(SESAME),Jordan.The experimentally measured results of the relative intensities were compared with the calculated results using the subshell fluorescence yield and the Coster-Kronig transition probabilities recommended by Campbell and the values based on the Dirac-Hartree-Slater model by Puri.The experimental and theoretical results are in agreement.In this work,L XRF relative intensities for the elements Sm,Gd,Tb,Er,Ta,W,Re,Hg,Pb and Bi at energies of 18 keV and 23 keV were measured. 展开更多
关键词 L shell x-ray fluorescence(XRF) relative intensities synchrotron radiation
下载PDF
Experimental Study of the X-Ray Radiation Source at Approximately Constant Radiation Temperature 被引量:1
4
作者 宋天明 杨家敏 +2 位作者 杨冬 李志超 尚万里 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第11期1108-1111,共4页
An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the... An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the shape of the drive laser pulse. Experiments are carried out on the Shenguang III prototype laser facility, and the experimentM results are presented for radiation sources with the flat-top lasting about 2.5 ns at two different peak temperatures of about 150 eV and 170 eV, respectively, including the the drive laser pulses and the time integrated possible improvements are discussed. time histories of the temperatures, the shapes of radiation spectra. The validity of the model and 展开更多
关键词 x-ray radiation source laser pulse shaping power balance
下载PDF
Small-angle X-ray scattering investigation of aging behavior of Al-Cu-Mg-Ag alloys using synchrotron radiation 被引量:3
5
作者 Zhang Jianbo Zhang Yongan +3 位作者 Zhu Baohong Liu Ruiqing Li Zhihui Li Xiwu 《Rare Metals》 SCIE EI CAS CSCD 2012年第6期537-540,共4页
The aging behavior of Al-Cu-Mg-Ag alloys with high Cu/Mg was studied by transmission electron microscopy (TEM) and small-angle X-ray scattering (SAXS) using synchrotron radiation. TEM study reveals that the major stre... The aging behavior of Al-Cu-Mg-Ag alloys with high Cu/Mg was studied by transmission electron microscopy (TEM) and small-angle X-ray scattering (SAXS) using synchrotron radiation. TEM study reveals that the major strengthening phases of the alloy after aging at 160?C for 10 h are Ω and less θ′. SAXS study shows that the scattering patterns are composed of several concentric circles at the beginning of aging process, which is replaced by the butterfly-wings scattering patterns with the increase of aging time. The butterfly-wings scattering patterns are composed of several branches. The angles between the branches are roughly equal to that between the habit planes of precipitates. The evolution of Guinier radius with aging time indicates the good coarsening resistance of the precipitates. The evolution of integrated intensity is consistent with the classical two-step precipitation process. 展开更多
关键词 Al-Cu-Mg-Ag alloys precipitate size synchrotron radiation small angle x-ray scattering
下载PDF
Internal Structure of Cambrian Fossil Embryo Markuelia Revealed in the Light of Synchrotron Radiation X-ray Tomographic Microscopy 被引量:5
6
作者 CHENG Gong PENG Fan +1 位作者 DUAN Baichuan DONG Xiping 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2011年第1期81-90,共10页
In the light of Synchrotron Radiation X-ray Tomographic Microscopy (SRXTM), the internal structure of Markuelia hunanensis is revealed. In one example, vitrification and peeling show the annuli hidden under the chor... In the light of Synchrotron Radiation X-ray Tomographic Microscopy (SRXTM), the internal structure of Markuelia hunanensis is revealed. In one example, vitrification and peeling show the annuli hidden under the chorion. Sectioning and 3-D reconstruction display an intact digestive tract from the inverted introvert to the terminal anus. The inverted introvert forms a rugby cavum. The following digestive tract is rope-like coiling, parallel to the body axis, about 650 μm in length, and uniform in diameter (-80 μm). An exquisitely preserved pipe-like structure is hidden in the middle of the rope-like structure, diameter 20--40 lam, with a length of -120 μm. We interpret this pipe-like structure as the possible epidermis of the gut and its surroundings as the possible residue of musculature, similar to that in Priapulans. The two symmetrical rod-shape structures connecting the body wall and digestive tract are interpreted as the possible retractor muscles. After comparing the well preserved Left-form and Right-form Body of Markuelia, we suggest that they may represent a dimorphism. Counted directly, one sample of Markuelia hunanensis possesses 62 annulations and the other 68. 展开更多
关键词 Markuelia synchrotron radiation x-ray Tomographic Microscopy (SRXTM) dimorphism
下载PDF
Three dimensional distribution of surfactant in microspheres revealed by synchrotron radiation X-ray microcomputed tomography 被引量:2
7
作者 Li Wu Manli Wang +7 位作者 Vikramjeet Singh Haiyan Li Zhen Guo Shuangying Gui Peter York Tiqiao Xiao Xianzhen Yin Jiwen Zhang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2017年第4期326-334,共9页
This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion s... This study investigated the formulation mechanism of microspheres via internal surfactant distribution. Eudragit L100 based microspheres loaded with bovine serum albumin were prepared by solid in oil in oil emulsion solvent evaporation method using acetone and liquid paraffin system containing sucrose stearate as a surfactant. The fabricated microspheres were evaluated for encapsulation efficiency, particle size, production yield, and in vitro release characteristics. The internal structures of microspheres were characterized using synchrotron radiation X-ray microcomputed tomography(SR-μCT). The enhanced contrast made the sucrose stearate distinguished from Eudragit to have its three dimensional(3D) distribution. Results indicated that the content and concentration determined the state of sucrose stearate and had significant influences on the release kinetics of protein. The dispersity of sucrose stearate was the primary factor that controlled the structure of the microspheres and further affected the encapsulation efficiency, effective drug loading, as well as in vitro release behavior. In conclusion, the 3D internal distribution of surfactant in microspheres and its effects on protein release behaviors have been revealed for the first time. The highly resolved 3D architecture provides new evidence for the deep understanding of the microsphere formation mechanism. 展开更多
关键词 Three dimensional synchrotron radiation x-ray microcomputed tomography DISTRIBUTION MICROSPHERE SUCROSE STEARATE
下载PDF
High pressure x-ray diffraction techniques with synchrotron radiation 被引量:6
8
作者 刘景 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期9-21,共13页
This article summarizes the developments of experimental techniques for high pressure x-ray diffraction(XRD) in diamond anvil cells(DACs) using synchrotron radiation. Basic principles and experimental methods for ... This article summarizes the developments of experimental techniques for high pressure x-ray diffraction(XRD) in diamond anvil cells(DACs) using synchrotron radiation. Basic principles and experimental methods for various diffraction geometry are described, including powder diffraction, single crystal diffraction, radial diffraction, as well as coupling with laser heating system. Resolution in d-spacing of different diffraction modes is discussed. More recent progress, such as extended application of single crystal diffraction for measurements of multigrain and electron density distribution, timeresolved diffraction with dynamic DAC and development of modulated heating techniques are briefly introduced. The current status of the high pressure beamline at BSRF(Beijing Synchrotron Radiation Facility) and some results are also presented. 展开更多
关键词 high pressure x-ray diffraction synchrotron radiation diamond anvil cell
下载PDF
The Study Internal Structure of the Annual Layers in Lake Sediments Using Synchrotron Radiation with X-ray Focusing Optics
9
作者 Fedor DARIN Ivan KALUGIN +1 位作者 Andrey DARIN Yakov RAKSHUN 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第S1期5-6,共2页
1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom se... 1 Introduction Annually laminated(varve)sedimentary deposits are considered as one of the most important archives,since they offer precise temporal information(years)in combination with high time resolutions.Bottom sediments of the lakes contain detailed geochemical information on 展开更多
关键词 VARVE .synchrotron radiation scanning X_ray fluorescence microanalysis focusing x-ray optics.
下载PDF
Investigation of the topological shape of bovine serum albumin in solution by small-angle x-ray scattering at Beijing synchrotron radiation facility
10
作者 董淑强 李丽琴 +2 位作者 刘鹏 董宇辉 陈熙萌 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第12期4574-4579,共6页
This paper reports that at a newly constructed small-angle x-ray scattering station of Beijing Synchrotron Radia- tion Facility, the topological shape of ligand-free bovine serum albumin in solution has been investiga... This paper reports that at a newly constructed small-angle x-ray scattering station of Beijing Synchrotron Radia- tion Facility, the topological shape of ligand-free bovine serum albumin in solution has been investigated. An appropriate scattering curve is obtained and the calculated value of the gyration radius is 31.2~=t=0.25 ~_ (11=0.1 nm) which is co- incident with other ones' results. It finds that the low-resolution structure models obtained by making use of ab initio reconstruction methods are fitting the crystal structure of human serum albumin very well. All of these results perform the potential of the beamline to apply to structural biology studies. The characteristics, the defects, and the improving measures of the station in future are also discussed. 展开更多
关键词 small-angle x-ray scattering ab initio methods bovine serum albumin Beijing synchrotron radiation facility
下载PDF
Hard X-ray in-line outline imaging for blood vessels:first generation synchrotron radiation without contrast agents in vitro
11
作者 姜庆军 冯赟 +5 位作者 肖湘生 刘士远 陈敏 肖体乔 田玉莲 朱佩平 《Journal of Medical Colleges of PLA(China)》 CAS 2006年第1期34-37,共4页
Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study in... Objective: Phase-contrast X-ray imaging which reduces radiation exposure, is a promising technique for observing the inner structures of biological soft tissues without the aid of contrast agents. The present study intends to depict blood vessels of rabbits and human livers with hard X-ray in-line outline imaging without contrast agents using synchrotron radiation. Methods: All samples were fixed with formalin and sliced into 6 mm sections. The imaging experiments were performed with Fuji-IX80 films on the 4W1A light beam of the first generation synchrotron radiation in Beijing, China. The device of the experiment, which supplies a maximum light spot size of 20×10 mm was similar to that of in-line holography. The photon energy was set at 8 KeV and high quality imagines were obtained by altering the distance between the sample and the film. Results: The trees of rabbit-liver blood vessels and the curved vessels of the cirrhotic human liver were revealed on the images, where vessels < 20 μm in diameter were differentiated. Conclusion: These results show that the blood vessels of liver samples can be revealed by using hard X-ray in-line outline imaging with the first generation synchrotron radiation without contrast agents. 展开更多
关键词 hard x-ray in-line outline imaging x-ray phase-contrast imaging blood vessels imaging synchrotron radiation
下载PDF
Focusing high-energy x-rays by a P MMA compound x-ray lens on Beijing synchrotron radiation facility
12
作者 乐孜纯 梁静秋 +6 位作者 董文 朱佩平 彭良强 王维彪 黄万霞 袁清习 王寯越 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第4期984-988,共5页
The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabricatio... The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays. 展开更多
关键词 PMMA compound x-ray lens focusing performance Beijing synchrotron radiation facility (BSRF)
下载PDF
The Significance of Solutions Obtained from Ill-Posed Systems of Linear Equations Constituted by Synchrotron Radiation Based Anomalous Small-Angle X-Ray Scattering
13
作者 Günter Johannes Goerigk 《Advances in Linear Algebra & Matrix Theory》 2018年第1期64-86,共23页
Synchrotron radiation based experimental techniques known as Anomalous Small-Angle X-ray Scattering (ASAXS) provide deep insight into the nanostructure of uncountable material systems in condensed matter research i.e.... Synchrotron radiation based experimental techniques known as Anomalous Small-Angle X-ray Scattering (ASAXS) provide deep insight into the nanostructure of uncountable material systems in condensed matter research i.e. solid state physics, chemistry, engineering and life sciences thereby rendering the origin of the macroscopic functionalization of the various materials via correlation to its structural architecture on a nanometer length scale. The techniques constitute a system of linear equations, which can be treated by matrix theory. The study aims to analyze the significance of the solutions of the stated matrix equations by use of the so-called condition numbers first introduced by A. Turing, J. von Neumann and H. Goldstine. Special attention was given for the comparison with direct methods i.e. the Gaussian elimination method. The mathematical roots of ill-posed ASAXS equations preventing matrix inversion have been identified. In the framework of the theory of von Neumann and Goldstine the inversion of certain matrices constituted by ASAXS gradually becomes impossible caused by non-definiteness. In Turing’s theory which starts from more general prerequisites, the principal minors of the same matrices approach singularity thereby imposing large errors on inversion. In conclusion both theories recommend for extremely ill-posed ASAXS problems avoiding inversion and the use of direct methods for instance Gaussian elimination. 展开更多
关键词 Matrix Inversion Condition NUMBERS LU-Decomposition Gaussian Elimination synchrotron radiation ANOMALOUS SMALL-ANGLE x-ray Scattering
下载PDF
Continued Study on Hohlraum Radiation Source with Approximately Constant Radiation Temperature
14
作者 宋天明 杨家敏 +2 位作者 朱托 李志超 黄成武 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第4期342-345,共4页
An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A ... An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A radiation source with a flattop temperature of about130 e V that lasted about 5 ns was obtained.The previous analytical iteration method based on power balance and self-similar solution of ablation was modified taking into account the plasma movements and it was used to design the laser pulse shape for experiment.A comparison between experimental results and simulation is presented and better agreement was achieved using the modified method.Further improvements are discussed. 展开更多
关键词 x-ray radiation source laser pulse shaping power balance
下载PDF
Characterization of metal element distributions in the rat brain following ischemic stroke by synchrotron radiation microfluorescence analysis 被引量:3
15
作者 Shu-Peng Shi Hui Wang +3 位作者 Zhuo-Hui Chen Xiao-Han Li Shi-Xin Liu Meng-Qi Zhang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第10期1-12,共12页
Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in... Ischemic stroke is one of the leading causes of death worldwide,and effective treatment strategies in the chronic phase of this disease remain insufficient.Homeostasis of metals in the brain plays an important role in maintaining normal brain function.However,the dynamic spatial distributions of iron,zinc,calcium,potassium,and copper in a rat brain following ischemic stroke and the association between structural distribution and function remain to be elucidated.In this study,we used a synchrotron radiation-based micro-X-ray fluorescence technique to image element mapping changes in special rat brain regions after ischemic stroke,showing the distribution characteristics of iron,zinc,calcium,potassium,and copper.We demonstrated,for the first time,the consistent dynamic spatial distributions of metal elements at a series of time points(3 h,4.5 h,6 h,12 h,1 d,3 d,5 d,7 d,10 d,14 d,28 d)after brain ischemia,which revealed that the homeostasis of iron,zinc,calcium,potassium,and copper in the brain was disturbed with distinctive change trends,providing clear insights in understanding the underlying pathogenesis of stroke from a novel perspective,thus laying the foundation of further developing new drug targets for stroke treatment. 展开更多
关键词 Ischemic stroke synchrotron radiation x-ray fluorescence METAL Rat brain
下载PDF
Time-resolved ultra-small-angle X-ray scattering beamline(BL10U1)at SSRF
16
作者 Wen-Qiang Hua Chun-Ming Yang +12 位作者 Ping Zhou Feng Tian Jin-You Lin Yu-Zhu Wang Xiao-Yun Li Xia-Ran Miao Chun-Xia Hong Qiu-Shi Huang Xin-Tong Zhao Yong-Feng Men Jie Wang Xing-Yu Gao Xiu-Hong Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第2期6-19,共14页
The construction of a new beamline,BL10U1,was completed at the Shanghai synchrotron radiation facility in 2020.This multipurpose beamline was designed to provide X-ray scattering techniques such as ultra-small-angle X... The construction of a new beamline,BL10U1,was completed at the Shanghai synchrotron radiation facility in 2020.This multipurpose beamline was designed to provide X-ray scattering techniques such as ultra-small-angle X-ray scattering(USAXS),small-angle X-ray scattering(SAXS),wide-angle X-ray scattering,and microfocus SAXS(μSAXS)for a broad user community.To realize fast time-resolved USAXS experiments,the beamline adopted an in-vacuum undulator with a total length of 1.6 m as the photon source.An in-house cryogenic-cooled double multilayer monochromator was installed to deliver a photon flux of approximately 10^(13) photons/s at a photon energy of 10 keV.The three-year successful operation of this beamline demonstrated that the monochromator operated smoothly,as expected.BL10U1 has three end stations in succession:USAXS end station,μSAXS end station,and end station for industrial applications.The minimum scattering vector q~0.0042 nm^(-1) at 10 keV can be achieved at the USAXS end station equipped with a 28 m-long and 1.8 m-diameter vacuum flight tube.At theμSAXS end station,a beam spot of less than 10×8μm was achieved for micro-SAXS experiments.In contrast,in situ experimental instruments up to 5 m high and 8 m wide can be mounted at the industrial application end station,which offers industrial scientists the opportunity to use their large industrial equipment.BL10U1 opens up a new capability to investigate phenomena such as non-equilibrium and dynamic processes of materials with a wide length scale from angstroms to micrometers with millisecond time resolution.In this paper,we also report beamline design considerations and commissioning results. 展开更多
关键词 synchrotron radiation Ultra-small-angle x-ray scattering Micro small-angle x-ray scattering USAXS Time resolved μSAXS
下载PDF
High-precision X-ray polarimeter based on channel-cut crystals
17
作者 Shang-Yu Si Zhong-Liang Li +8 位作者 Wen-Hong Jia Lian Xue Hong-Xin Luo Jian-Cai Xu Bai-Fei Shen Lin-Gang Zhang Liang-Liang Ji Yu-Xin Leng Ren-Zhong Tai 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期30-39,共10页
We report on using synthetic silicon for a high-precision X-ray polarimeter comprising a polarizer and an analyzer,each based on a monolithic channel-cut crystal used at multiple Brewster reflections with a Bragg angl... We report on using synthetic silicon for a high-precision X-ray polarimeter comprising a polarizer and an analyzer,each based on a monolithic channel-cut crystal used at multiple Brewster reflections with a Bragg angle very close to 45°.Experiments were performed at the BL09B bending magnet beamline of the Shanghai Synchrotron Radiation Facility using a Si(800)crystal at an X-ray energy of 12.914 keV.A polarization purity of 8.4×10^(-9)was measured.This result is encouraging,as the measured polarization purity is the best-reported value for the bending magnet source.Notably,this is the firstly systematic study on the hard X-ray polarimeter in China,which is crucial for exploring new physics,such as verifying vacuum birefringence. 展开更多
关键词 x-ray polarimeter Vacuum birefringence synchrotron radiation Channel-cut crystal
下载PDF
Real-time pore structure evolution difference between deep and shallow coal during gas adsorption:A study based on synchrotron radiation small-angle X-ray scattering
18
作者 Yingfeng Sun Shuaipeng Zhu +3 位作者 Fei Xie Chujian Han Yixin Zhao Zetian Zhang 《Particuology》 SCIE EI CAS CSCD 2024年第4期114-123,共10页
Coal seam CO_(2) sequestration is an important option to address global warming.A better knowledge on coal pore structure evolution during gas adsorption can provide guidance for coal seams CO_(2) seques-tration.Howev... Coal seam CO_(2) sequestration is an important option to address global warming.A better knowledge on coal pore structure evolution during gas adsorption can provide guidance for coal seams CO_(2) seques-tration.However,few investigations on the pore structure evolution differences between the deep and shallow coal were conducted during gas adsorption.In this study,based on the real-time synchrotron radiation small-angle X-ray scattering(SAXS)observation,the average pore diameter and pore surface fractal dimension evolution differences between deep and shallow coal were investigated from the as-pects of coal compositions and stress history.Two types of coal deformation(inner-swelling and outer-swelling)coexist during gas adsorption.Coal compositions have significant impact on the dominance of deformation type.The dominance of inner-swelling in deep coal is induced by the higher ash contents,and there is the decrease of average pore diameter during gas adsorption.The impact of stress-history(burial depth)on adsorption-induced deformation is more prominent than that of gas adsorption ca-pacity.In deep coal,the surface fractal dimension evolution presents a negative correlation with the evolution of pore diameters.In shallow coal,the surface fractal dimension evolution presents a Langmuir-type correlation with the adsorption time. 展开更多
关键词 COAL Gas adsorption synchrotron radiation small-angle x-ray SCATTERING Pore diameter Surface fractal dimension
原文传递
High-precision X-ray characterization for basic materials in modern high-end integrated circuit
19
作者 Weiran Zhao Qiuqi Mo +3 位作者 Li Zheng Zhongliang Li Xiaowei Zhang Yuehui Yu 《Journal of Semiconductors》 EI CAS CSCD 2024年第7期12-24,共13页
Semiconductor materials exemplify humanity's unwavering pursuit of enhanced performance,efficiency,and functionality in electronic devices.From its early iterations to the advanced variants of today,this field has... Semiconductor materials exemplify humanity's unwavering pursuit of enhanced performance,efficiency,and functionality in electronic devices.From its early iterations to the advanced variants of today,this field has undergone an extraordinary evolution.As the reliability requirements of integrated circuits continue to increase,the industry is placing greater emphasis on the crystal qualities.Consequently,conducting a range of characterization tests on the crystals has become necessary.This paper will examine the correlation between crystal quality,device performance,and production yield,emphasizing the significance of crystal characterization tests and the important role of high-precision synchrotron radiation X-ray topography characterization in semiconductor analysis.Finally,we will cover the specific applications of synchrotron radiation characterization in the development of semiconductor materials. 展开更多
关键词 x-ray topography synchrotron radiation semiconductor materials crystal defects
下载PDF
The hard X-ray nanoprobe beamline at the SSRF
20
作者 Yan He Hui Jiang +6 位作者 Dong-Xu Liang Zhi-Sen Jiang Huai-Na Yu Hua Wang Cheng-Wen Mao Jia-Nan Xie Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期79-88,共10页
The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 t... The hard X-ray nanoprobe beamline BL13U is a phase-Ⅱ beamline project at the Shanghai Synchrotron Radiation Facility.The beamline aims to enable comprehensive experiments at high spatial resolutions ranging from 50 to 10 nm. The X-ray energy range of the beamline, 5–25 keV, can detect most elements in the periodic table. Two operating modes were designed to accommodate the experimental requirements of high-energy resolution or high photon flux, respectively. X-ray nanofluorescence, nanodiffraction, and coherent diffraction imaging are developed as the main experimental techniques for BL13U. This paper describes the beamline optics, end station configurations, experimental methods under development, and preliminary test results. This comprehensive overview aims to provide a clear understanding of the beamline capabilities and potential applications. 展开更多
关键词 Shanghai synchrotron radiation facility Hard x-ray nanoprobe x-ray nanofocusing
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部