The characteristics of the flowfields of a synthetic jet actuator are experimentally investigated with the slot-nozzle driven by the piezoelectric membrane. The particle image velocimetry (PIV) and the hot-wire anem...The characteristics of the flowfields of a synthetic jet actuator are experimentally investigated with the slot-nozzle driven by the piezoelectric membrane. The particle image velocimetry (PIV) and the hot-wire anemometer are utilized to measure the flowfields and the velocity profiles of the actuator with different actuating factors. Analytical results show that pairs of counter-rotating vortices are generated near the nozzle. With the development of the synthetic ject, the synthetic jet rapidly spreads in the slot-width direction; while in the slot-length direction, it contracts firstly and slowly spreads. The centerline velocity distribution has a up-down tendency varying with axial distances, and accelerates to its maximum at z/b= 10. The transverse velocity profile across the slot-width is centro-symmetric and self-similar. However, the velocity profiles across the slot-length are saddle-like near the nozzle. It shows that there are two resonance frequencies for the actuator. If the actuator works with the resonance frequency, the vorticity and the velocity of the synthetic jet are higher than those of other frequencies. Compared with the continuous jet, the synthetic jet shows special flow characteristics.展开更多
A primary air jet vectoring control system with a novel synthetic jet actuator (SJA) is presented and simulated numerically. The results show that, in comparison with an existing traditional synthetic jet actuator, ...A primary air jet vectoring control system with a novel synthetic jet actuator (SJA) is presented and simulated numerically. The results show that, in comparison with an existing traditional synthetic jet actuator, which is able to perform the duty of either "push" or "pull", one novel synthetic jet actuator can fulfill both "push" and "pull" functions to vector the primary jet by shifting a slide block inside it. Therefore, because the new actuator possesses greater efficiency, it has potentiality to replace the existing one in various appli- cations, such as thrust vectoring and the reduction of thermal signature. Moreover, as the novel actuator can fulfill those functions that the existing one can not, it may well be expected to popularize it into more flow control systems.展开更多
The plasma synthetic jet is a novel active flow control method because of advantages such as fast response, high frequency and non-moving parts, and it has received more attention recently, especially regarding its ap...The plasma synthetic jet is a novel active flow control method because of advantages such as fast response, high frequency and non-moving parts, and it has received more attention recently, especially regarding its application to high-speed flow control. In this paper, the experimental characterization of the plasma synthetic jet actuator is investigated. The actuator consists of a copper anode, a tungsten cathode and a ceramic shell, and with these three parts a cavity can be formed inside the actuator. A pulsed-DC power supply was adopted to generate the arc plasma between the electrodes, through which the gas inside was heated and expanded from the orifice. Discharge parameters such as voltage and current were recorded, respectively, by voltage and current probes. The schlieren system was used for flow visualization, and jet velocities with different discharge parameters were measured. The schlieren images showed that the strength of plasma jets in a series of pulses varies from each other. Through velocity measurement, it is found that at a fixed frequency, the jet velocity hardly increases when the discharge voltage ranges from 16 kV to 20 kV. However, with the discharge voltage fixed, the jet velocity suddenly decreases when the pulse frequency rises above 500 Hz, whereas at other testing frequencies no such decrease was observed. The maximum jet velocity measured in the experiment was up to 110 m/s, which is believed to be effective for high-speed flow control.展开更多
A primary jet vectoring using synthetic jet actuators with different exit configurations was investigated, and the main physical factors influencing jet vectoring were analyzed and summarized. The physical factors of ...A primary jet vectoring using synthetic jet actuators with different exit configurations was investigated, and the main physical factors influencing jet vectoring were analyzed and summarized. The physical factors of the pressure difference, the location and area of the lower pressure region, the component of the synthetic jet momentum and the entrainment ratio of the synthetic jet flow to primary jet flow directly control the vectoring force and the vectoring angle. Three characteristic parameters of the synthetic jet contribute to the pressure difference and the area of the lower pressure region Both the extension step and slope angle of the actuator exit have functions of regulating the location of the lower pressure region, the area of the lower pressure region, and the entrainment ratio of the synthetic jet flow to primary jet flow. The slope angle of the actuator exit has additional functions of regulating the component of the synthetic jet momentum. Based upon analyzing the physical factors of jet vectoring control with synthetic jets, the source variables of the physical factors were established. A preparatory control model of jet vectoring using synthetic jet actuator was presented, and it has the benefit of explaining the efficiency of jet vectoring using synthetic jet actuator with source variables at different values, and it indicates the optimal actuator is taking full advantage of the regulating function.展开更多
This work investigates the active control of a fully developed turbulent boundary layer by a submerged synthetic jet actuator.The impacts of the control are explored by measuring the streamwise velocities using partic...This work investigates the active control of a fully developed turbulent boundary layer by a submerged synthetic jet actuator.The impacts of the control are explored by measuring the streamwise velocities using particle image velocimetry,and reduction of the skin-friction drag is observed in a certain range downstream of the orifice.The coherent structure is defined and extracted using a spatial two-point correlation function,and it is found that the synthetic jet can efficiently reduce the streamwise scale of the coherent structure.Proper orthogonal decomposition analysis reveals that large-scale turbulent kinetic energy is significantly attenuated with the introduction of a synthetic jet.The conditional averaging results show that the induction effect of the prograde vortex on the low-speed fluid in a large-scale fluctuation velocity field is deadened,thereby suppressing the bursting process near the wall.展开更多
The flow around a square cylinder with a synthetic jet positioned at the rear surface is numerically investigated with the unsteady Reynolds-averaged Navier-Stokes(URANS)method.Instead of the typical sinusoidal wave,a...The flow around a square cylinder with a synthetic jet positioned at the rear surface is numerically investigated with the unsteady Reynolds-averaged Navier-Stokes(URANS)method.Instead of the typical sinusoidal wave,a bi-frequency signal is adopted to generate the synthetic jet.The bi-frequency signal consists of a basic sinusoidal wave and a high-frequency wave.Cases with various amplitudes of the high-frequency component are simulated.It is found that synthetic jets actuated by bi-frequency signals can realize better drag reduction with lower energy consumption when appropriate parameter sets are applied.A new quantity,i.e.,the actuation efficiency Ae,is used to evaluate the controlling efficiency.The actuation efficiency Ae reaches its maximum of 0.2668 when the amplitude of the superposed high-frequency signal is 7.5%of the basic signal.The vortex structures and frequency characteristics are subsequently analyzed to investigate the mechanism of the optimization of the bi-frequency signal.When the synthetic jet is actuated by a single-frequency signal with a characteristic velocity of 0.112 m/s,the wake is asymmetrical.The alternative deflection of vortex pairs and the peak at half of the excitation frequency in the power spectral density(PSD)function are detected.In the bi-frequency cases with the same characteristic velocity,the wake gradually turns to be symmetrical with the increase in the amplitude of the high-frequency component.Meanwhile,the deflection of the vortex pairs and the peak at half of the excitation frequency gradually disappear as well.展开更多
A major issue of plasma synthetic jet actuator(PSJA)is the severe performance deterioration at high working frequency.In this study,experiments and numerical simulation are combined together to investigate the influen...A major issue of plasma synthetic jet actuator(PSJA)is the severe performance deterioration at high working frequency.In this study,experiments and numerical simulation are combined together to investigate the influence of thermal conductivity,throat length(Lth)and discharge duration(Td)on the high-frequency characteristics of PSJA.Results show that the variation of the actuator thermal conductivity and discharge duration will not alter the saturation frequency of the actuator,whereas decreasing the throat length results in an increase of the saturation frequency.For a short-duration capacitive discharge of 1.7μs,a clear shock wave is issued from the orifice,followed by a weak jet.As a comparison,when the discharge duration is increased up to 202.6μs,a strong jet column is formed and no obvious shock wave can be visualized.Based on numerical simulation results,it becomes clear that the long-duration pulse-DC discharge is able to heat the cavity gas to a much higher temperature(3141 K)than capacitive discharge,greatly improving the conversion efficiency of the arc discharge energy to the internal energy of the cavity gas.In addition,high-speed Schlieren imaging is deployed to study the performance degradation mechanism of PSJA at high working frequency.Monitor of the exit jet grayscale indicates that as long as the saturation frequency is exceeded,the actuator becomes unstable due to insufficient refresh time.The higher the discharge frequency,the more frequently the phenomenon of‘misfires’will occur,which explains well the decaying jet total pressure at above saturation frequency.展开更多
This paper studied a concept of micromixer with a synthetic jet placed at the bottom of a rectangular channel. Due to periodic ejections from and suctions into the channel, the fluids are mixed effectively. To study t...This paper studied a concept of micromixer with a synthetic jet placed at the bottom of a rectangular channel. Due to periodic ejections from and suctions into the channel, the fluids are mixed effectively. To study the effects of the inlet velocity, the jet intensity and frequency, and the jet location on the mixing efficiency, 3-D numerical simulations of the micromixer have been carried out. It has been found that when the jet intensity and the frequency are fixed, the mixing efficiency increases when Re 〈 50, and decreases when Re 〉 50 with the best mixing efficiency achieved at Re = 50. When the ratio of the jet velocity magnitude to the inlet velocity is taken as 10 and the jet frequency is 100 Hz, the mixing index reaches the highest value. It has also been found that to get better mixing efficiency, the orifice of the synthetic jet should be asymmetrically located away from the channel's centerline.展开更多
Plasma synthetic jet actuator(PSJA) has a wide application prospect in the high-speed flow control field for its high jet velocity.In this paper,the influence of the air pressure on the performance of a two-electrod...Plasma synthetic jet actuator(PSJA) has a wide application prospect in the high-speed flow control field for its high jet velocity.In this paper,the influence of the air pressure on the performance of a two-electrode PSJA is investigated by the schlieren method in a large range from 7 k Pa to 100 k Pa.The energy consumed by the PSJA is roughly the same for all the pressure levels.Traces of the precursor shock wave velocity and the jet front velocity vary a lot for different pressures.The precursor shock wave velocity first decreases gradually and then remains at 345 m/s as the air pressure increases.The peak jet front velocity always appears at the first appearance of a jet,and it decreases gradually with the increase of the air pressure.A maximum precursor shock wave velocity of 520 m/s and a maximum jet front velocity of 440 m/s are observed at the pressure of 7 k Pa.The averaged jet velocity in one period ranges from 44 m/s to 54 m/s for all air pressures,and it drops with the rising of the air pressure.High velocities of the precursor shock wave and the jet front indicate that this type of PSJA can still be used to influence the high-speed flow field at 7 k Pa.展开更多
The turbulent boundary layer(TBL)is actively controlled by the synthetic jet generated from a circular hole.According to the datasets of velocity fields acquired by a time-resolved particle image velocimetry(TR-PIV)sy...The turbulent boundary layer(TBL)is actively controlled by the synthetic jet generated from a circular hole.According to the datasets of velocity fields acquired by a time-resolved particle image velocimetry(TR-PIV)system,the average drag reduction rate of 6.2%in the downstream direction of the hole is obtained with control.The results of phase averaging show that the synthetic jet generates one vortex pair each period and the consequent vortex evolves into hairpin vortex in the environment with free-stream,while the reverse vortex decays rapidly.From the statistical average,it can be found that a low-speed streak is generated downstream.Induced by the two vortex legs,the fluid under them converges to the middle.The drag reduction effect produced by the synthetic jet is local,and it reaches a maximum value at x^(+)=400,where the drag reduction rate reaches about 12.2%.After the extraction of coherent structure from the spatial two-point correlation analysis,it can be seen that the synthetic jet suppresses the streamwise scale and wall–normal scale of the large scale coherent structure,and slightly weakens the spanwise motion to achieve the effect of drag reduction.展开更多
Numerical simulations are performed to investigate the effects of gas compressibility on the synthetic jet flow. A slot synthetic jet and a circular orifice synthetic jet are simulated assuming 2D and axis-symmetric b...Numerical simulations are performed to investigate the effects of gas compressibility on the synthetic jet flow. A slot synthetic jet and a circular orifice synthetic jet are simulated assuming 2D and axis-symmetric behavior. The velocity of orifice, frequency response and the compressibility are studied through simulation. The numerical results are validated against existing experimental and analytical data, and good agreement are obtained, Gas compressibility effects on the synthetic jet flow are discussed. In conclusion, for the two kinds of different synthetic jets studied in this paper, the critical values of Mach number are 0. 082 and 0. 033.展开更多
An array of 30 plasma synthetic jet actuators(PSJAs)is deployed using a modified multichannel discharge circuit to suppress the flow separation over a straight-wing model.The lift and drag of the wing model are measur...An array of 30 plasma synthetic jet actuators(PSJAs)is deployed using a modified multichannel discharge circuit to suppress the flow separation over a straight-wing model.The lift and drag of the wing model are measured by a force balance,and the velocity fields over the suction surface are captured by a particle imaging velocimetry system.Results show that the flow separation of the straight wing originates from the middle of the model and expands towards the wingtips as the angle of attack increases.The flow separation can be suppressed effectively by the PSJAs array.The best flow control effect is achieved at a dimensionless discharge frequency of F^+=1,with the peak lift coefficient increased by 10.5%and the stall angle postponed by 2°.To further optimize the power consumption of the PSJAs,the influence of the density of PSJAs on the flow control effect is investigated.A threshold of the density exits(with the spanwise spacing of PSJAs being 0.2 times of the chord length in the current research),below which the flow control effect starts to deteriorate remarkably.In addition,for comparison purposes,a dielectric barrier discharge(DBD)plasma actuator is installed at the same location of the PSJAs.At the same power consumption,4.9%increase of the peak lift coefficient is achieved by DBD,while that achieved by PSJAs reaches 5.6%.展开更多
The primary issue regarding the plasma synthetic jet actuator(PSJA)is its performance attenuation at high frequencies.To solve this issue,a self-supplementing,dual-cavity,plasma synthetic jet actuator(SD-PSJA)is desig...The primary issue regarding the plasma synthetic jet actuator(PSJA)is its performance attenuation at high frequencies.To solve this issue,a self-supplementing,dual-cavity,plasma synthetic jet actuator(SD-PSJA)is designed,and the static properties of the SD-PSJA are investigated through experiments and numerical simulations.The pressure measurement shows that the SD-PSJA has two saturation frequencies(1200 Hz and 2100 Hz),and the experimental results show that both the saturation frequencies decrease as the volume of the bottom cavity of the SD-PSJA increases.As the size of the supplement hole increases,the first saturation frequency increases continuously,while the second saturation frequency shows a trend of first decreasing and then increasing.Numerical simulations show that the working process of the SD-PSJA is similar to that of the PSJA,but the volume of the cavity in the SD-PSJA is smaller than that of the PSJA;the SD-PSJA can supplement air to the top cavity through two holes,thus reducing the refresh time and effectively improving the jet intensity of the actuator at high frequencies.展开更多
This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of thi...This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of this phenomenon were used: the pressure profile using the Kiel total pressure probe, the velocity profile using the CTA (constant temperature anemometry) probe and the visualization of the flow field using the hot film and the thermo camera, The experimental results with and without the influence of the synthetic jet were compared, as well the impact of the phase shift of the neighbouring synthetic jets. As a reference case, the flow around the hump without the influence of the synthetic jet was selected. The results of the measurement are presented in figures and compared.展开更多
In the last two decades synthetic jet actuators have gained much interest among flow control techniques due to their short response time, high jet velocity and absence of traditional piping, that matches the requireme...In the last two decades synthetic jet actuators have gained much interest among flow control techniques due to their short response time, high jet velocity and absence of traditional piping, that matches the requirements of reduced size and low weight. A synthetic jet is generated by the diaphragm oscillation (generally driven by a piezo- electric element) in a relatively small cavity, producing periodic cavity pressure variations associated to cavity volume changes. The high pressure air exhausts through an orifice, converting membrane elastic energy in jet kinetic energy. This review paper faces the development of various lumped-element models (LEM) as practical tools to design and manufacturing actuators. LEM can predict quickly device performances such as frequency response in terms of membrane displacement, cavity pressure and jet velocity, as well as efficiency of energy conversion of input Joule power into useful kinetic power of air jet. Actuator performance is analyzed also by varying typical geometric parameters such as cavity height and orifice diameter and length, through a proper dimensionless form of the governing equations.展开更多
The hypersonic shock-shock interaction flow field at double-wedge geometries controlled by plasma synthetic jet actuator is experimentally studied in a Ma = 8 high-enthalpy shock tunnel with the purpose of exploring a...The hypersonic shock-shock interaction flow field at double-wedge geometries controlled by plasma synthetic jet actuator is experimentally studied in a Ma = 8 high-enthalpy shock tunnel with the purpose of exploring a novel technique for reducing surface heat flux in a real flight environment. The results demonstrate that increasing the discharge energy is advantageous in eliminating the shock wave, shifting the shock wave interaction point, and shortening the control response time. The oblique shock wave can be completely removed when the actuator's discharge energy grows from 0.4 J to 11.5 J, and the displacement of the shock wave interaction point increases by 124.56%, while the controlled response time is shortened by 30 μs. Besides, the reduction in diameter of the jet exit is firstly proved to have a negative impact on energy deposition in a working environment with incoming flow, which reduces the discharge energy and hence decreases the control effect. The shock wave control response time lengthens when the jet exits away from the second wedge. Along with comparing the change in wall heat flux at the second wedge over time, the control effect of plasma synthetic jet actuator with and without inflation is also analyzed. When plasma synthetic jet works in inflatable mode, both the ability to eliminate shock waves and the shifting effect of the shock wave interaction point are increased significantly, and the wall heat flux is also reduced.展开更多
Large Eddy Simulation(LES)is first used to investigate the drag reduction effect of an array-based configuration of Plasma Synthetic Jet Actuators(PSJAs)on a hemisphere in supersonic inflow,and analyze the effect of e...Large Eddy Simulation(LES)is first used to investigate the drag reduction effect of an array-based configuration of Plasma Synthetic Jet Actuators(PSJAs)on a hemisphere in supersonic inflow,and analyze the effect of energy allocation and array angle on the drag reduction performance of opposing Plasma Synthetic Jet(PSJ)in this paper.Numerical simulation results have been compared with experimental data,confirming the validity of the simulation method.The results show that different energy allocations have a significant effect on the drag of the hemisphere.However,the effect of the change in array angle on the drag of the hemisphere is not as noticeable as the effect caused by energy allocation.Interference regions between the two PSJAs occur,which undermine the effectiveness of drag reduction.High Turbulent Kinetic Energy(TKE)regions primarily concentrate on the core region of the jet and downstream of the bow shock.The influence of the array angle on TKE is most evident in the downstream region of the exits of the PSJs on both sides.Temporal evolution of the coherent structures reveals that as the PSJ intensity decreases,the largescale vortices progressively break up into smaller-scale vortices,and energy is also transferred from large-scale structures to small-scale structures.展开更多
A three-electrode high-energy plasma synthetic jet(PSJ) actuator was used for shock wave control. This actuator is an enhanced version of the two-electrode actuator as a high-voltage trigger electrode is added to incr...A three-electrode high-energy plasma synthetic jet(PSJ) actuator was used for shock wave control. This actuator is an enhanced version of the two-electrode actuator as a high-voltage trigger electrode is added to increase the cavity volume and the input energy while retaining a relatively low disruptive voltage. The electrical properties were studied using current-voltage measurements, and the energy consumption was calculated. To assess the jet strength, the penetration of PSJ was compared with empirical values, and the results show that the momentum flux ratio of PSJ for a capacitance of 0.96, 1.6, and 3 μF was approximately equal to 0.6, 1.0, and 1.3, respectively. The interaction of PSJ with shock waves was acquired using high-speed shadowgraph imaging. The shock was generated by a 25° compression ramp in Mach 2 flow, and PSJ actuator was placed up-stream of the compression ramp. Under the action of PSJ, the strength of the shock was notably weakened, and the near-wall part of the shock was entirely eliminated. The results show the good control effect of the three-electrode high-energy PSJ in high-speed flow.展开更多
Plasma Synthetic Jet(PSJ) actuators have shown wide and promising application prospects in high-speed flow control, due to their advantages including high exhaust speed, wide frequency band, rapid response, and non-mo...Plasma Synthetic Jet(PSJ) actuators have shown wide and promising application prospects in high-speed flow control, due to their advantages including high exhaust speed, wide frequency band, rapid response, and non-moving components. Although previous studies on PSJ actuators are abundant, most of them have focused on the performance of a single actuator. However, in practice, an actuator array is very necessary for large-scale aerodynamic actuation on account of the small affected area of a single PSJ. In this paper, the characteristics of a twoelectrode plasma synthetic jet actuator array in serial are investigated experimentally. Compared to a parallel actuator array, the serial actuator array requires simpler power supply design and is much easier to realize. High-speed photography of the discharge evolution, voltage-current measurement, and shadowgraphy visualization are used in the investigation. Experimental results show that, for the serial actuator array, weak discharges happen firstly between energized and suspending electrodes, and then a strong pulse arc discharge is triggered. The breakdown voltage in serial is irrelevant to such factors as the number of actuators, the maximum or minimum gap in serial,the connection sequence, etc. It is mainly determined by the sum of gaps. For serial actuators with the same anode-to-cathode spacing, the energy deposition is the same, and the jet is synchronous and similar. Because of the entrainment and merging of adjacent jet vortices, the jet front speed of an aligned synchronous jet array increases as the orifice distance decreases. To achieve the highest jet front velocity, the orifice of the actuator has an optimal diameter.展开更多
A promising strategy of synthetic jet arrays (SJA) control for NACA0021 airfoil in preventing flow separation and delaying stall is investigated. Through aerodynamic forces, flowfield and velocity profiles measureme...A promising strategy of synthetic jet arrays (SJA) control for NACA0021 airfoil in preventing flow separation and delaying stall is investigated. Through aerodynamic forces, flowfield and velocity profiles measurements, it indicates that the synthetic jet (S J) could enlarge the mixing of the shear layer and then enhance the stability of boundary layer, resulting in scope reduction of the flow separation zone. Furthermore, the control effects of dual jet arrays positioned at 15%c (Actuator 1) and 40%c (Actuator 2) respectively are systematically investigated with different jet parameters, such as two typical relative phase angles and various incline angles of the jet. The jet closer to the leading edge of airfoil is more advantageous in delaying the stall of airfoil, and overall, the flow control performances of jet arrays are better than those of single actuator. At the angle of attack (AoA) just approaching and larger than the stall AoA, jet array with 180° phase difference could increase the lift coefficient more significantly and prevent flow separation. When momentum coefficient of the jet arrays is small, a larger jet angle of Actuator 2 is more effective in improving the maximum lift coefficient of airfoil. With a larger momentum coefficient of jet array, a smaller jet angle of Actuator 2 is more effective.展开更多
文摘The characteristics of the flowfields of a synthetic jet actuator are experimentally investigated with the slot-nozzle driven by the piezoelectric membrane. The particle image velocimetry (PIV) and the hot-wire anemometer are utilized to measure the flowfields and the velocity profiles of the actuator with different actuating factors. Analytical results show that pairs of counter-rotating vortices are generated near the nozzle. With the development of the synthetic ject, the synthetic jet rapidly spreads in the slot-width direction; while in the slot-length direction, it contracts firstly and slowly spreads. The centerline velocity distribution has a up-down tendency varying with axial distances, and accelerates to its maximum at z/b= 10. The transverse velocity profile across the slot-width is centro-symmetric and self-similar. However, the velocity profiles across the slot-length are saddle-like near the nozzle. It shows that there are two resonance frequencies for the actuator. If the actuator works with the resonance frequency, the vorticity and the velocity of the synthetic jet are higher than those of other frequencies. Compared with the continuous jet, the synthetic jet shows special flow characteristics.
基金National Natural Science Foundation of China (90205016, 50176055)
文摘A primary air jet vectoring control system with a novel synthetic jet actuator (SJA) is presented and simulated numerically. The results show that, in comparison with an existing traditional synthetic jet actuator, which is able to perform the duty of either "push" or "pull", one novel synthetic jet actuator can fulfill both "push" and "pull" functions to vector the primary jet by shifting a slide block inside it. Therefore, because the new actuator possesses greater efficiency, it has potentiality to replace the existing one in various appli- cations, such as thrust vectoring and the reduction of thermal signature. Moreover, as the novel actuator can fulfill those functions that the existing one can not, it may well be expected to popularize it into more flow control systems.
基金supported by National Natural Science Foundation of China(Nos.51207169,51276197)
文摘The plasma synthetic jet is a novel active flow control method because of advantages such as fast response, high frequency and non-moving parts, and it has received more attention recently, especially regarding its application to high-speed flow control. In this paper, the experimental characterization of the plasma synthetic jet actuator is investigated. The actuator consists of a copper anode, a tungsten cathode and a ceramic shell, and with these three parts a cavity can be formed inside the actuator. A pulsed-DC power supply was adopted to generate the arc plasma between the electrodes, through which the gas inside was heated and expanded from the orifice. Discharge parameters such as voltage and current were recorded, respectively, by voltage and current probes. The schlieren system was used for flow visualization, and jet velocities with different discharge parameters were measured. The schlieren images showed that the strength of plasma jets in a series of pulses varies from each other. Through velocity measurement, it is found that at a fixed frequency, the jet velocity hardly increases when the discharge voltage ranges from 16 kV to 20 kV. However, with the discharge voltage fixed, the jet velocity suddenly decreases when the pulse frequency rises above 500 Hz, whereas at other testing frequencies no such decrease was observed. The maximum jet velocity measured in the experiment was up to 110 m/s, which is believed to be effective for high-speed flow control.
基金Project supported by the National Natural Science Foundation of China(Nos.90205016 and 50176055)
文摘A primary jet vectoring using synthetic jet actuators with different exit configurations was investigated, and the main physical factors influencing jet vectoring were analyzed and summarized. The physical factors of the pressure difference, the location and area of the lower pressure region, the component of the synthetic jet momentum and the entrainment ratio of the synthetic jet flow to primary jet flow directly control the vectoring force and the vectoring angle. Three characteristic parameters of the synthetic jet contribute to the pressure difference and the area of the lower pressure region Both the extension step and slope angle of the actuator exit have functions of regulating the location of the lower pressure region, the area of the lower pressure region, and the entrainment ratio of the synthetic jet flow to primary jet flow. The slope angle of the actuator exit has additional functions of regulating the component of the synthetic jet momentum. Based upon analyzing the physical factors of jet vectoring control with synthetic jets, the source variables of the physical factors were established. A preparatory control model of jet vectoring using synthetic jet actuator was presented, and it has the benefit of explaining the efficiency of jet vectoring using synthetic jet actuator with source variables at different values, and it indicates the optimal actuator is taking full advantage of the regulating function.
基金supported by the National Natural Science Foundation of China(Grant Nos.11732010,11972251,11872272,11902218,and 11802195)the National Key Research and Development Program of China,on‘Green Buildings and Building Industrialization’(Grant No.2018YFC0705300)。
文摘This work investigates the active control of a fully developed turbulent boundary layer by a submerged synthetic jet actuator.The impacts of the control are explored by measuring the streamwise velocities using particle image velocimetry,and reduction of the skin-friction drag is observed in a certain range downstream of the orifice.The coherent structure is defined and extracted using a spatial two-point correlation function,and it is found that the synthetic jet can efficiently reduce the streamwise scale of the coherent structure.Proper orthogonal decomposition analysis reveals that large-scale turbulent kinetic energy is significantly attenuated with the introduction of a synthetic jet.The conditional averaging results show that the induction effect of the prograde vortex on the low-speed fluid in a large-scale fluctuation velocity field is deadened,thereby suppressing the bursting process near the wall.
基金supported by the National Natural Science Foundation of China(No.11721202)。
文摘The flow around a square cylinder with a synthetic jet positioned at the rear surface is numerically investigated with the unsteady Reynolds-averaged Navier-Stokes(URANS)method.Instead of the typical sinusoidal wave,a bi-frequency signal is adopted to generate the synthetic jet.The bi-frequency signal consists of a basic sinusoidal wave and a high-frequency wave.Cases with various amplitudes of the high-frequency component are simulated.It is found that synthetic jets actuated by bi-frequency signals can realize better drag reduction with lower energy consumption when appropriate parameter sets are applied.A new quantity,i.e.,the actuation efficiency Ae,is used to evaluate the controlling efficiency.The actuation efficiency Ae reaches its maximum of 0.2668 when the amplitude of the superposed high-frequency signal is 7.5%of the basic signal.The vortex structures and frequency characteristics are subsequently analyzed to investigate the mechanism of the optimization of the bi-frequency signal.When the synthetic jet is actuated by a single-frequency signal with a characteristic velocity of 0.112 m/s,the wake is asymmetrical.The alternative deflection of vortex pairs and the peak at half of the excitation frequency in the power spectral density(PSD)function are detected.In the bi-frequency cases with the same characteristic velocity,the wake gradually turns to be symmetrical with the increase in the amplitude of the high-frequency component.Meanwhile,the deflection of the vortex pairs and the peak at half of the excitation frequency gradually disappear as well.
基金supported by National Natural Science Foundation of China(No.12002384)the National Key Laboratory Foundation of China(No.614220210200112)the Foundation Strengthening Project(No.2019-JCJQ-JJ-077)。
文摘A major issue of plasma synthetic jet actuator(PSJA)is the severe performance deterioration at high working frequency.In this study,experiments and numerical simulation are combined together to investigate the influence of thermal conductivity,throat length(Lth)and discharge duration(Td)on the high-frequency characteristics of PSJA.Results show that the variation of the actuator thermal conductivity and discharge duration will not alter the saturation frequency of the actuator,whereas decreasing the throat length results in an increase of the saturation frequency.For a short-duration capacitive discharge of 1.7μs,a clear shock wave is issued from the orifice,followed by a weak jet.As a comparison,when the discharge duration is increased up to 202.6μs,a strong jet column is formed and no obvious shock wave can be visualized.Based on numerical simulation results,it becomes clear that the long-duration pulse-DC discharge is able to heat the cavity gas to a much higher temperature(3141 K)than capacitive discharge,greatly improving the conversion efficiency of the arc discharge energy to the internal energy of the cavity gas.In addition,high-speed Schlieren imaging is deployed to study the performance degradation mechanism of PSJA at high working frequency.Monitor of the exit jet grayscale indicates that as long as the saturation frequency is exceeded,the actuator becomes unstable due to insufficient refresh time.The higher the discharge frequency,the more frequently the phenomenon of‘misfires’will occur,which explains well the decaying jet total pressure at above saturation frequency.
基金the National Natural Science Foundation of China(10372099)
文摘This paper studied a concept of micromixer with a synthetic jet placed at the bottom of a rectangular channel. Due to periodic ejections from and suctions into the channel, the fluids are mixed effectively. To study the effects of the inlet velocity, the jet intensity and frequency, and the jet location on the mixing efficiency, 3-D numerical simulations of the micromixer have been carried out. It has been found that when the jet intensity and the frequency are fixed, the mixing efficiency increases when Re 〈 50, and decreases when Re 〉 50 with the best mixing efficiency achieved at Re = 50. When the ratio of the jet velocity magnitude to the inlet velocity is taken as 10 and the jet frequency is 100 Hz, the mixing index reaches the highest value. It has also been found that to get better mixing efficiency, the orifice of the synthetic jet should be asymmetrically located away from the channel's centerline.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.51407197,51522606,51336011,91541120,and 11472306)
文摘Plasma synthetic jet actuator(PSJA) has a wide application prospect in the high-speed flow control field for its high jet velocity.In this paper,the influence of the air pressure on the performance of a two-electrode PSJA is investigated by the schlieren method in a large range from 7 k Pa to 100 k Pa.The energy consumed by the PSJA is roughly the same for all the pressure levels.Traces of the precursor shock wave velocity and the jet front velocity vary a lot for different pressures.The precursor shock wave velocity first decreases gradually and then remains at 345 m/s as the air pressure increases.The peak jet front velocity always appears at the first appearance of a jet,and it decreases gradually with the increase of the air pressure.A maximum precursor shock wave velocity of 520 m/s and a maximum jet front velocity of 440 m/s are observed at the pressure of 7 k Pa.The averaged jet velocity in one period ranges from 44 m/s to 54 m/s for all air pressures,and it drops with the rising of the air pressure.High velocities of the precursor shock wave and the jet front indicate that this type of PSJA can still be used to influence the high-speed flow field at 7 k Pa.
基金the National Natural Science Foundation of China(Grant Nos.11732010,11972251,11872272,11902218,and 12172242)the National Key Research and Development Program of the Ministry of Science and Technology,China(Grant No.2018YFC0705300)。
文摘The turbulent boundary layer(TBL)is actively controlled by the synthetic jet generated from a circular hole.According to the datasets of velocity fields acquired by a time-resolved particle image velocimetry(TR-PIV)system,the average drag reduction rate of 6.2%in the downstream direction of the hole is obtained with control.The results of phase averaging show that the synthetic jet generates one vortex pair each period and the consequent vortex evolves into hairpin vortex in the environment with free-stream,while the reverse vortex decays rapidly.From the statistical average,it can be found that a low-speed streak is generated downstream.Induced by the two vortex legs,the fluid under them converges to the middle.The drag reduction effect produced by the synthetic jet is local,and it reaches a maximum value at x^(+)=400,where the drag reduction rate reaches about 12.2%.After the extraction of coherent structure from the spatial two-point correlation analysis,it can be seen that the synthetic jet suppresses the streamwise scale and wall–normal scale of the large scale coherent structure,and slightly weakens the spanwise motion to achieve the effect of drag reduction.
基金Supported by the National Natural Science Foundation of China (60843005) BIT Fundamental Research Foundation( 20110542016)
文摘Numerical simulations are performed to investigate the effects of gas compressibility on the synthetic jet flow. A slot synthetic jet and a circular orifice synthetic jet are simulated assuming 2D and axis-symmetric behavior. The velocity of orifice, frequency response and the compressibility are studied through simulation. The numerical results are validated against existing experimental and analytical data, and good agreement are obtained, Gas compressibility effects on the synthetic jet flow are discussed. In conclusion, for the two kinds of different synthetic jets studied in this paper, the critical values of Mach number are 0. 082 and 0. 033.
基金National Natural Science Foundation of China(Nos.12002384 and 11802341)the National Key Laboratory Foundation of China(No.614220210200112)the Academician Workstation Foundation of the Green Aerotechnics Research Institute of Chongqing Jiaotong University(No.GATRI2020C06003)。
文摘An array of 30 plasma synthetic jet actuators(PSJAs)is deployed using a modified multichannel discharge circuit to suppress the flow separation over a straight-wing model.The lift and drag of the wing model are measured by a force balance,and the velocity fields over the suction surface are captured by a particle imaging velocimetry system.Results show that the flow separation of the straight wing originates from the middle of the model and expands towards the wingtips as the angle of attack increases.The flow separation can be suppressed effectively by the PSJAs array.The best flow control effect is achieved at a dimensionless discharge frequency of F^+=1,with the peak lift coefficient increased by 10.5%and the stall angle postponed by 2°.To further optimize the power consumption of the PSJAs,the influence of the density of PSJAs on the flow control effect is investigated.A threshold of the density exits(with the spanwise spacing of PSJAs being 0.2 times of the chord length in the current research),below which the flow control effect starts to deteriorate remarkably.In addition,for comparison purposes,a dielectric barrier discharge(DBD)plasma actuator is installed at the same location of the PSJAs.At the same power consumption,4.9%increase of the peak lift coefficient is achieved by DBD,while that achieved by PSJAs reaches 5.6%.
基金National Natural Science Foundation of China(No.61971345)the Foundation for Key Laboratories of National Defense Science and Technology of China(No.614220120030810).
文摘The primary issue regarding the plasma synthetic jet actuator(PSJA)is its performance attenuation at high frequencies.To solve this issue,a self-supplementing,dual-cavity,plasma synthetic jet actuator(SD-PSJA)is designed,and the static properties of the SD-PSJA are investigated through experiments and numerical simulations.The pressure measurement shows that the SD-PSJA has two saturation frequencies(1200 Hz and 2100 Hz),and the experimental results show that both the saturation frequencies decrease as the volume of the bottom cavity of the SD-PSJA increases.As the size of the supplement hole increases,the first saturation frequency increases continuously,while the second saturation frequency shows a trend of first decreasing and then increasing.Numerical simulations show that the working process of the SD-PSJA is similar to that of the PSJA,but the volume of the cavity in the SD-PSJA is smaller than that of the PSJA;the SD-PSJA can supplement air to the top cavity through two holes,thus reducing the refresh time and effectively improving the jet intensity of the actuator at high frequencies.
文摘This paper deals with the influence of phase modulated synthetic jet on the aerodynamics of the hump in a closed test section Of the Eiffel-type wind tunnel. Three experimental methods of measurement techniques of this phenomenon were used: the pressure profile using the Kiel total pressure probe, the velocity profile using the CTA (constant temperature anemometry) probe and the visualization of the flow field using the hot film and the thermo camera, The experimental results with and without the influence of the synthetic jet were compared, as well the impact of the phase shift of the neighbouring synthetic jets. As a reference case, the flow around the hump without the influence of the synthetic jet was selected. The results of the measurement are presented in figures and compared.
文摘In the last two decades synthetic jet actuators have gained much interest among flow control techniques due to their short response time, high jet velocity and absence of traditional piping, that matches the requirements of reduced size and low weight. A synthetic jet is generated by the diaphragm oscillation (generally driven by a piezo- electric element) in a relatively small cavity, producing periodic cavity pressure variations associated to cavity volume changes. The high pressure air exhausts through an orifice, converting membrane elastic energy in jet kinetic energy. This review paper faces the development of various lumped-element models (LEM) as practical tools to design and manufacturing actuators. LEM can predict quickly device performances such as frequency response in terms of membrane displacement, cavity pressure and jet velocity, as well as efficiency of energy conversion of input Joule power into useful kinetic power of air jet. Actuator performance is analyzed also by varying typical geometric parameters such as cavity height and orifice diameter and length, through a proper dimensionless form of the governing equations.
基金supported by the National Natural Science Foundation of China (Nos. 92271110, 12202488, 12072352 and T2221002)the National Major Science and Technology Project of China (Nos. J2019-II-0016-0037 and J2019-Ⅲ-0010-0054)the Natural Science Program of National University of Defense Technology, China (No. ZK22-30)。
文摘The hypersonic shock-shock interaction flow field at double-wedge geometries controlled by plasma synthetic jet actuator is experimentally studied in a Ma = 8 high-enthalpy shock tunnel with the purpose of exploring a novel technique for reducing surface heat flux in a real flight environment. The results demonstrate that increasing the discharge energy is advantageous in eliminating the shock wave, shifting the shock wave interaction point, and shortening the control response time. The oblique shock wave can be completely removed when the actuator's discharge energy grows from 0.4 J to 11.5 J, and the displacement of the shock wave interaction point increases by 124.56%, while the controlled response time is shortened by 30 μs. Besides, the reduction in diameter of the jet exit is firstly proved to have a negative impact on energy deposition in a working environment with incoming flow, which reduces the discharge energy and hence decreases the control effect. The shock wave control response time lengthens when the jet exits away from the second wedge. Along with comparing the change in wall heat flux at the second wedge over time, the control effect of plasma synthetic jet actuator with and without inflation is also analyzed. When plasma synthetic jet works in inflatable mode, both the ability to eliminate shock waves and the shifting effect of the shock wave interaction point are increased significantly, and the wall heat flux is also reduced.
基金supported by the National Science and Technology Major Project of China (No. J2019-Ⅲ-00100054)the National Natural Science Foundation of China (Nos. 52075538, 12202488, 92271110)+1 种基金the Natural Science Foundation of Hunan Province, China (No. 2023JJ30622)the Natural Science Program of National University of Defense Technology, China (No. ZK22-30)
文摘Large Eddy Simulation(LES)is first used to investigate the drag reduction effect of an array-based configuration of Plasma Synthetic Jet Actuators(PSJAs)on a hemisphere in supersonic inflow,and analyze the effect of energy allocation and array angle on the drag reduction performance of opposing Plasma Synthetic Jet(PSJ)in this paper.Numerical simulation results have been compared with experimental data,confirming the validity of the simulation method.The results show that different energy allocations have a significant effect on the drag of the hemisphere.However,the effect of the change in array angle on the drag of the hemisphere is not as noticeable as the effect caused by energy allocation.Interference regions between the two PSJAs occur,which undermine the effectiveness of drag reduction.High Turbulent Kinetic Energy(TKE)regions primarily concentrate on the core region of the jet and downstream of the bow shock.The influence of the array angle on TKE is most evident in the downstream region of the exits of the PSJs on both sides.Temporal evolution of the coherent structures reveals that as the PSJ intensity decreases,the largescale vortices progressively break up into smaller-scale vortices,and energy is also transferred from large-scale structures to small-scale structures.
基金supported by the National Natural Science Foundation of China(Grant Nos.11372349&11502295)the Nature Science Fund for Distinguished Young Scholars of National University of Defense Technology(Grant No.CJ110101)
文摘A three-electrode high-energy plasma synthetic jet(PSJ) actuator was used for shock wave control. This actuator is an enhanced version of the two-electrode actuator as a high-voltage trigger electrode is added to increase the cavity volume and the input energy while retaining a relatively low disruptive voltage. The electrical properties were studied using current-voltage measurements, and the energy consumption was calculated. To assess the jet strength, the penetration of PSJ was compared with empirical values, and the results show that the momentum flux ratio of PSJ for a capacitance of 0.96, 1.6, and 3 μF was approximately equal to 0.6, 1.0, and 1.3, respectively. The interaction of PSJ with shock waves was acquired using high-speed shadowgraph imaging. The shock was generated by a 25° compression ramp in Mach 2 flow, and PSJ actuator was placed up-stream of the compression ramp. Under the action of PSJ, the strength of the shock was notably weakened, and the near-wall part of the shock was entirely eliminated. The results show the good control effect of the three-electrode high-energy PSJ in high-speed flow.
基金supported by the National Natural Science Foundation of China(Nos.11372349,11502295,and11572349)
文摘Plasma Synthetic Jet(PSJ) actuators have shown wide and promising application prospects in high-speed flow control, due to their advantages including high exhaust speed, wide frequency band, rapid response, and non-moving components. Although previous studies on PSJ actuators are abundant, most of them have focused on the performance of a single actuator. However, in practice, an actuator array is very necessary for large-scale aerodynamic actuation on account of the small affected area of a single PSJ. In this paper, the characteristics of a twoelectrode plasma synthetic jet actuator array in serial are investigated experimentally. Compared to a parallel actuator array, the serial actuator array requires simpler power supply design and is much easier to realize. High-speed photography of the discharge evolution, voltage-current measurement, and shadowgraphy visualization are used in the investigation. Experimental results show that, for the serial actuator array, weak discharges happen firstly between energized and suspending electrodes, and then a strong pulse arc discharge is triggered. The breakdown voltage in serial is irrelevant to such factors as the number of actuators, the maximum or minimum gap in serial,the connection sequence, etc. It is mainly determined by the sum of gaps. For serial actuators with the same anode-to-cathode spacing, the energy deposition is the same, and the jet is synchronous and similar. Because of the entrainment and merging of adjacent jet vortices, the jet front speed of an aligned synchronous jet array increases as the orifice distance decreases. To achieve the highest jet front velocity, the orifice of the actuator has an optimal diameter.
基金support of the National Natural Science Foundation of China(No.11272150)
文摘A promising strategy of synthetic jet arrays (SJA) control for NACA0021 airfoil in preventing flow separation and delaying stall is investigated. Through aerodynamic forces, flowfield and velocity profiles measurements, it indicates that the synthetic jet (S J) could enlarge the mixing of the shear layer and then enhance the stability of boundary layer, resulting in scope reduction of the flow separation zone. Furthermore, the control effects of dual jet arrays positioned at 15%c (Actuator 1) and 40%c (Actuator 2) respectively are systematically investigated with different jet parameters, such as two typical relative phase angles and various incline angles of the jet. The jet closer to the leading edge of airfoil is more advantageous in delaying the stall of airfoil, and overall, the flow control performances of jet arrays are better than those of single actuator. At the angle of attack (AoA) just approaching and larger than the stall AoA, jet array with 180° phase difference could increase the lift coefficient more significantly and prevent flow separation. When momentum coefficient of the jet arrays is small, a larger jet angle of Actuator 2 is more effective in improving the maximum lift coefficient of airfoil. With a larger momentum coefficient of jet array, a smaller jet angle of Actuator 2 is more effective.