In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study des...In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.展开更多
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car...To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average.展开更多
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running...Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...展开更多
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h...This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.展开更多
为探索多能互补的清洁能源供暖技术,满足北京市村镇分散式建筑清洁供暖需求,在北京农村地区建设太阳能-地源热泵复合式系统,进行太阳能补热热泵供暖实验,并利用COMSOL软件开展地温场热均衡模拟研究。结果表明:相较单一地源热泵系统,太...为探索多能互补的清洁能源供暖技术,满足北京市村镇分散式建筑清洁供暖需求,在北京农村地区建设太阳能-地源热泵复合式系统,进行太阳能补热热泵供暖实验,并利用COMSOL软件开展地温场热均衡模拟研究。结果表明:相较单一地源热泵系统,太阳能补热热泵供暖方案下,地源侧出水温度提升23%,系统制热能效比(Coefficient of Performance,COP)和机组COP分别提升19%、25%;系统运行10 a,地源热泵系统单季节运行方案下总的取热量要多于间歇期自然恢复量,地温场总均衡为-8.91×10^(9)kJ;单一地源热泵方式运行和太阳能补热方式运行在双季节情况下总的取热量小于总的排热量,地温场总均衡分别为4.220×10^(9)、1.084×10^(10)kJ。因此,双季节运行方案对地温场不会产生负均衡,反而会对地温场有一定的热量补充。地源热泵系统运行中加入太阳能补热,对地温场的影响更小,可显著提升系统和机组效率,该模式适用于北京农村地区特别是供暖需求较大的建筑。展开更多
The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter seas...The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump.展开更多
针对电动汽车冬天取暖能耗较高,设计了基于蒸气压缩循环的热泵空调试验系统,研究了制热模式下不同的环境温度和压缩机转速对车室内平均温度、高压管路内部工质的温度和压力、系统能效比(COP,Coefficient of Performance)等参数的影响....针对电动汽车冬天取暖能耗较高,设计了基于蒸气压缩循环的热泵空调试验系统,研究了制热模式下不同的环境温度和压缩机转速对车室内平均温度、高压管路内部工质的温度和压力、系统能效比(COP,Coefficient of Performance)等参数的影响.试验结果表明,当环境温度和压缩机的转速较高时,压缩机出口、车室内换热器出口处工质的温度和压力值较大,车室内平均温度的上升速度越快,达到舒适温度所需的时间越短.在压缩机转速相同时,环境温度越高,系统的COP值越大.展开更多
文摘In the field of heat pumps,there are a number of parameters that affect the performance and efficiency of the apparatus,which have been the subject of studies by individual researchers in the literature.This study describes an experimental method in order to investigate the effects of some significant parameters on heat pump performance.In this regard,a laboratory heat pump setup has been utilized to operate in different working conditions for achieving an appropriate estimation to find out effects of mentioned parameters such as refrigerant type and charge amount,compressor oil viscosity,compressor cooling fan,secondary fluids temperature and flow rate.Different refrigerants have been selected and used as circulating fluid in the installed heat pump.Although this work has been devoted to a detailed attempt to recognize the effects of various parameters on the coefficient of performance(COP) value,an appropriate method has been carried out to survey the obtained results by using economic analysis.It was revealed that one of the main parameters is refrigerant charge amount which has a notable effect on COP.The temperature of the heat source was also tested and the performance of the system increased by more than 11% by employing mentioned modifications and various operating conditions.In addition,by selecting a low viscosity compressor oil,the system performance increased by 18%.This improvement is more than 6% for the case that cooling fan is installed to cool the compressor element.
基金The National Natural Science Foundation of China(No.50676059)
文摘To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average.
基金Supported by National Natural Science Foundation of China (No. 50578048)"Heating, Gas, Ventilation and Air Conditioning" Key Laboratory Open Subject in Beijing (No. KF200710)the Postdoctoral Researcher Science Foundation of China (No. 20090450986)
文摘Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...
文摘This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5.
文摘为探索多能互补的清洁能源供暖技术,满足北京市村镇分散式建筑清洁供暖需求,在北京农村地区建设太阳能-地源热泵复合式系统,进行太阳能补热热泵供暖实验,并利用COMSOL软件开展地温场热均衡模拟研究。结果表明:相较单一地源热泵系统,太阳能补热热泵供暖方案下,地源侧出水温度提升23%,系统制热能效比(Coefficient of Performance,COP)和机组COP分别提升19%、25%;系统运行10 a,地源热泵系统单季节运行方案下总的取热量要多于间歇期自然恢复量,地温场总均衡为-8.91×10^(9)kJ;单一地源热泵方式运行和太阳能补热方式运行在双季节情况下总的取热量小于总的排热量,地温场总均衡分别为4.220×10^(9)、1.084×10^(10)kJ。因此,双季节运行方案对地温场不会产生负均衡,反而会对地温场有一定的热量补充。地源热泵系统运行中加入太阳能补热,对地温场的影响更小,可显著提升系统和机组效率,该模式适用于北京农村地区特别是供暖需求较大的建筑。
文摘The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump.
文摘针对电动汽车冬天取暖能耗较高,设计了基于蒸气压缩循环的热泵空调试验系统,研究了制热模式下不同的环境温度和压缩机转速对车室内平均温度、高压管路内部工质的温度和压力、系统能效比(COP,Coefficient of Performance)等参数的影响.试验结果表明,当环境温度和压缩机的转速较高时,压缩机出口、车室内换热器出口处工质的温度和压力值较大,车室内平均温度的上升速度越快,达到舒适温度所需的时间越短.在压缩机转速相同时,环境温度越高,系统的COP值越大.