期刊文献+
共找到8篇文章
< 1 >
每页显示 20 50 100
Recovery of Hydrogen from Ammonia Plant Tail Gas by Absorption-Hydration Hybrid Method 被引量:5
1
作者 刘蓓 王秀林 +3 位作者 唐绪龙 杨兰英 孙长宇 陈光进 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第5期784-791,共8页
In this work, the absorption-hydration hybrid method was used to recover (hydrogen + nitrogen) from (hydrogen + nitrogen + methane + argon) tail gas mixtures of synthetic ammonia plant through hydrate formatio... In this work, the absorption-hydration hybrid method was used to recover (hydrogen + nitrogen) from (hydrogen + nitrogen + methane + argon) tail gas mixtures of synthetic ammonia plant through hydrate formation/dissociation. A high-pressure reactor with magnetic stirrer was used to study the separation efficiency. The in-fluences of the concentration of anti-agglomerant, temperature, pressure, initial gas-liquid volume ratio, and oil-water volume ratio on the separation efficiency were systematically investigated in the presence of tetrahydro-furan (THF). Anti-agglomerant was used to disperse hydrate particles into the condensate phase for water-in-oil emulsion system. Since nitrogen is the material for ammonia production, the objective production in our separation process is (hydrogen + nitrogen). Our experimental results show that by adopting appropriate operating conditions, high concentration of (hydrogen + nitrogen) can be obtained using the proposed technology based on forming hydrate. 展开更多
关键词 SEPARATION HYDRATE HYDROGEN synthetic ammonia plant tail gas
下载PDF
Corrosion of Different Materials in Combustion Chamber of Yellow Phosphorus Tail Gas in Industrial Boiler 被引量:2
2
作者 郜华萍 宁平 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第1期53-57,共5页
The corrosion of materials in combustion chamber of yellow phosphor tall gas was investrgated. The results reveal that the corrosion behavior is different for different materials under actual work conditions.
关键词 yellow phosphorus tail gas CORROSION industrial boiler CARBON metal material
下载PDF
Catalysts for decomposing ozone tail gas 被引量:1
3
作者 LIU Chang-an, SUN De-zhi, WANG Hui, LI Wei (Department of Environmental Science and Engineering, Harbin Institute of Technology, Harbin 150001,China. 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第6期779-782,共4页
The preparation of immobilizing-catalysts for decomposing ozone by using dipping method was studied. XRD, XPS and TEM were used to characterize the catalysts. The three kinds of catalysts were selected preferentially,... The preparation of immobilizing-catalysts for decomposing ozone by using dipping method was studied. XRD, XPS and TEM were used to characterize the catalysts. The three kinds of catalysts were selected preferentially, and their catalytic activities were investigated. The results showed that the catalyst with activated carbon dipping acetate(active components are Mn:Cu=3:2, active component proportion in catalyst is 15%, calcination temperature is 200℃) has the best catalytic activity for ozone decomposing. One gram of catalyst can decompose 17.6 g ozone at initial ozone concentration of 2.5 g/m 3 and the residence time in reactor of 0.1 s. The experimental results also indicated that humidity of reaction system had negative effect on catalytic activity. 展开更多
关键词 ozone tail gas catalytic decomposition immobilizing-catalyst MnO 2 CUO
下载PDF
Gas cyclone-liquid jet absorption separator used for treatment of tail gas containing HCl in titanium dioxide industry
4
作者 Liwang Wang Hualin Wang +2 位作者 Liang Ma Zhanghuang Yang Erwen Chen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2022年第4期435-446,共12页
In the titanium dioxide industry,there is a lack of a low-cost and high-efficiency treatment method for chloride containing tail gas.In this paper,the removal of HCl from the titanium dioxide industry by gas cyclone-l... In the titanium dioxide industry,there is a lack of a low-cost and high-efficiency treatment method for chloride containing tail gas.In this paper,the removal of HCl from the titanium dioxide industry by gas cyclone-liquid jet separator was studied,while Ca(OH)_(2),Na_(2)CO_(3),NaOH solution,and water were used as absorbents.This paper investigated the influence of gas cyclone-liquid jet separator’s various process parameters on the removal rate of hydrogen chloride gas.The mechanism of mass transfer in the process of removing hydrogen chloride was discussed,and the effect and feasibility of HCl gas removal in the gas cyclone-liquid jet absorption separator were studied.The results showd that the removal efficiency of hydrogen chloride maintained above 95%,up to 99.9%,and the total mass transfer coefficient reached0.28 mol·m^(-3)·s^(-1)·k Pa^(-1).Under the same conditions,the absorption effect and total mass transfer coefficient of weak basic absorption liquid can be greatly improved by increasing the flow rate of absorption liquid,but the absorption effect and total mass transfer coefficient of strong alkaline absorption liquid can’t be improved obviously.The larger the inlet gas volume,the higher the gas concentration,the lower the absorption efficiency and the lower the total volumetric mass transfer coefficient. 展开更多
关键词 Wet dechlorination HCL tail gas gas cyclone-liquid jet absorption SEPARATOR Titanium dioxide industry
下载PDF
Commercial Application of the RAR Sulfur Recovery and Tail Gas Treating Process
5
作者 GuoHong ZhangSongping 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2003年第4期1-9,共9页
The 40kt/a sulfur recovery unit for tail gas treating applying the reduction-absorption-recycling (RAR) technology is aimed at regeneration of the rich amine solution and recovery of sulfur to operate in tandem with t... The 40kt/a sulfur recovery unit for tail gas treating applying the reduction-absorption-recycling (RAR) technology is aimed at regeneration of the rich amine solution and recovery of sulfur to operate in tandem with the 1.2Mt/a diesel hydrofining unit. The process unit calibration data have revealed that the recovery of total sulfur reaches 99.86%, which is 6.65 percentage points higher than that before application of the RAR technology. The SO2 content in vented tail gas is 0.27 t/d, which is much less than the latest emission standard prescribed by the State. The factors that can affect the unit operation have been analyzed and corresponding measures have been suggested including the necessity to improve the control over the reaction temperature in the tail gas hydrogenation unit. 展开更多
关键词 sulfur recovery unit tail gas commercial scale claus sulfur recovery
下载PDF
Experimental Investigation on the Performance of[APMIm][NTf_(2)]for Capturing CO_(2)from Flue Gas of the Cement Kiln Tail 被引量:1
6
作者 PAN Lisheng SHI Weixiu +1 位作者 LI Bing WEI Xiaolin 《Journal of Thermal Science》 SCIE EI CAS CSCD 2021年第5期1780-1788,共9页
Facing the global warming trend,humanity has been paying more and more attention to the Carbon Capture,Utilization and Storage.Large amounts of CO_(2)is emitted with burning fossil fuel as well as by some special indu... Facing the global warming trend,humanity has been paying more and more attention to the Carbon Capture,Utilization and Storage.Large amounts of CO_(2)is emitted with burning fossil fuel as well as by some special industrial processes like the decomposition of calcium carbonate in a cement plant.The cement industry contributes about 7%of the total worldwide CO_(2)emissions and the CO_(2)concentration of flue gas of the cement kiln tail even exceeds 30%.Ionic liquid is considered to be an effective and potential material to capture CO_(2).In order to investigate the performance of ionic liquids for capturing CO_(2)from flue gas of the cement kiln tail,an experiment system was established and an ionic liquid,[APMIm][NTf_(2)](1-aminopropyl-3-imidazolium bis(trifluoromethylsulfonyl)imine),was tested using pure CO_(2)and simulated gas.The results showed that both physical and chemical absorption play roles while physical absorption dominates in the absorption process.Both the absorption capacity and rate decrease with raising the operating temperature.In the experiment with pure CO_(2),the absorption capacity is 0.296molCO_(2)⋅molIL−1 at 30℃ and 0.067molCO_(2)⋅molIL−1 at 70℃.Meanwhile,the ionic liquid can be regenerated for recycling without obvious changes of the absorption capacity.When the ionic liquid is used for flue gas of the cement kiln tail rather than pure CO_(2),a sharp decrease of the absorption capacity and rate was observed obviously.The absorption capacity at 30℃ dropped even to 0.038molCO_(2)⋅mol_(IL)^(−1),12.8%of that for pure CO_(2).Additionally,a natural desorption of CO_(2)from the ionic liquid was observed and affected the experimental results of the absorption capacity and the absorption-desorption rate to some extent. 展开更多
关键词 ionic liquid CO_(2)absorption Carbon Capture Utilization and Storage(CCUS) flue gas of the cement kiln tail
原文传递
An investigation of reaction furnace temperatures and sulfur recovery 被引量:2
7
作者 S.ASADI M.PAKIZEH M.POURAFSHARI CHENAR 《Frontiers of Chemical Science and Engineering》 SCIE EI CSCD 2011年第3期362-371,共10页
In a modern day sulfur recovery unit(SRU),hydrogen sulfide(H_(2)S)is converted to elemental sulfur using a modified Claus unit.A process simulator called TSWEET has been used to consider the Claus process.The effect o... In a modern day sulfur recovery unit(SRU),hydrogen sulfide(H_(2)S)is converted to elemental sulfur using a modified Claus unit.A process simulator called TSWEET has been used to consider the Claus process.The effect of the H_(2)S concentration,the H_(2)S/CO_(2) ratio,the input airflow rate,the acid gasflow of the acid gas(AG)splitter and the temperature of the acid gas feed at three different oxygen concentrations(in the air input)on the main burner temperature have been studied.Also the effects of the tail gas ratio and the catalytic bed type on the sulfur recovery were studied.The bed temperatures were optimized in order to enhance the sulfur recovery for a given acid gas feed and air input.Initially when the fraction of AG splitterflow to the main burner was increased,the temperature of the main burner increased to a maximum but then decreased sharply when theflow fraction was further increased;this was true for all three concentrations of oxygen.However,if three other parameters(the concentration of H_(2)S,the ratio H_(2)S/CO_(2) and theflow rate of air)were increased,the temperature of the main burner increased monotonically.This increase had differ-ent slopes depending on the oxygen concentration in the input air.But,by increasing the temperature of the acid gas feed,the temperature of the main burner decreased.In general,the concentration of oxygen in the input air into the Claus unit had little effect on the temperature of the main burner(This is true for all parameters).The optimal catalytic bed temperature,tail gas ratio and type of catalytic bed were also determined and these conditions are a minimum temperature of 300°C,a ratio of 2.0 and a hydrolysing Claus bed. 展开更多
关键词 Claus unit concentration of H_(2)S tail gas ratio sulfur recovery catalytic bed
原文传递
NICE's Indirect Coal-to-Liquid Process for Producing Clean Transportation Fuels Using Fischer-Tropsch Synthesis
8
作者 Omar M.Basha Li Weng +2 位作者 Zhuo-wu Men Wayne Xu Badie I.Morsi 《Frontiers of Engineering Management》 2016年第4期362-376,共15页
China is currently the world's top coal consumer and the largest oil importer to sustain its rising economy and meet the mounting demand for transportation fuels.However,the increasing emissions due to the huge fo... China is currently the world's top coal consumer and the largest oil importer to sustain its rising economy and meet the mounting demand for transportation fuels.However,the increasing emissions due to the huge fossil fuels consumption,coupled with oil market instability,could derail China's economic growth and jeopardize its national energy security.To face such a hurdle,China has been aggressively supporting low-carbon businesses opportunuties over the past decade,has recently announced several plans to cap coal utilization,and is currently the biggest investor in clean energy technologies.Coal-toLiquid(CTL) is one of the most promising clean coal technologies,offering an ideal solution that can meet China's energy demands and environmental expectations.It is widely known that the Shenhua Group has pioneered and is currently leading the commercialization of the Direct Coal Liquefaction(DCL) process in China.This paper highlights a part of the joint research effort undertaken by the National Institute of Clean-and-LowCarbon Energy(NICE) and University of Pittsburgh in order to develop and commercialize the Indirect Coal Liquefaction(ICL) process.In this mission,NICE has built and operated an ICL plant including a large-scale(5.8-m ID and 30-m height) Slurry-Bubble-Column Reactor(SBCR)for Fischer-Tropsch synthesis using iron catalyst.The research,conducted at the University of Pittsburgh over the past few years,allowed building a user-friendly Simulator,based on a comprehensive SBCR model integrated with Aspen Plus and is validated using data from the NICE actual ICL plant.In this paper,the Simulator predictions of the performance of the NICE SBCR,operating with ironand cobalt catalysts under four different tail gas recycle strategies:(1) direct recycle;(2) using a Pressure Swing Adsorption(PSA) unit;(3) using a reformer;and(4) using a Chemical looping Combustion(CLC) process,are presented.It should be mentioned also that our joint research effort has laid the foundation for the design of a commercial-scale SBCR for producing one-million tons per annum of environmentally friendly and ultraclean(no sulfur,no nitrogen and virtually no aromatics) transportation fuels,which could greatly contribute to ensuring China's national energy security while curbing its lingering emission problems. 展开更多
关键词 Fischer-Tropsch synthesis tail gas recycle simulations process design
原文传递
上一页 1 下一页 到第