This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short...This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short length twisted tape inserts. The length of the pipe is approximately 2436.80 mm long with 29 mm inner and 33 mm outer diameter respectively. A constant heat flux is taken which generated the boundary layer of the pipe close to the flowing fluid around the boundary. The simulations are considered for the stationary and the time dependent module for 35 seconds with different length of inserts. The comparisons are made among the results. We observed that the transfer of heat is enhanced significantly with the increase of the length of inserts inside the computational domain. We also found that, full length twisted tape inserts are more effective than comparing with the short length inserts and without insert.展开更多
Heat transfer and flow behaviors in three-dimensional circular tubes with loose-fit multiple channel twisted tapes were numerically studied. The investigation was examined for Reynolds numbers (Re) ranging from 5000...Heat transfer and flow behaviors in three-dimensional circular tubes with loose-fit multiple channel twisted tapes were numerically studied. The investigation was examined for Reynolds numbers (Re) ranging from 5000 to 15,000, by using air as testing fluid. Effects of the multiple channel number (N = 2, 3, and 4), clearance ratio (CR = 0.0, 0.025, 0.05, and 0.075) on heat transfer enhancement and flow friction were examined. The numerical results indicate that the tubes with loose-fit multiple channel twisted tapes perform higher heat transfer rates than the plain tube. The enhanced heat transfer rate is escorted with larger pressure drop. Both heat transfer and pressure drop increase with increasing multiple channel number (N) and decreasing clearance ratio (CR). Heat transfer augmented by the loose-fit multiple channel twisted tape with N = 4 is higher than those enhanced by the ones with N = 2 and 3 by around 9.5-17.8% and 5.8-7.8%, respectively. In addition, the loose-fit multiple channel twisted tapes with clearance ratio of 0.025, 0.05, and 0.075 give lower heat transfer rates than the one with CR = 0.0 by around 8.4%, 17.5%, and 28.8%, respectively.展开更多
文摘This paper performs a simulation study of the heat transfer phenomena in a tubular U-loop pipe. We have investigated the enhancement of heat transfer with mass flow in a pipe without insert, with full length and short length twisted tape inserts. The length of the pipe is approximately 2436.80 mm long with 29 mm inner and 33 mm outer diameter respectively. A constant heat flux is taken which generated the boundary layer of the pipe close to the flowing fluid around the boundary. The simulations are considered for the stationary and the time dependent module for 35 seconds with different length of inserts. The comparisons are made among the results. We observed that the transfer of heat is enhanced significantly with the increase of the length of inserts inside the computational domain. We also found that, full length twisted tape inserts are more effective than comparing with the short length inserts and without insert.
文摘Heat transfer and flow behaviors in three-dimensional circular tubes with loose-fit multiple channel twisted tapes were numerically studied. The investigation was examined for Reynolds numbers (Re) ranging from 5000 to 15,000, by using air as testing fluid. Effects of the multiple channel number (N = 2, 3, and 4), clearance ratio (CR = 0.0, 0.025, 0.05, and 0.075) on heat transfer enhancement and flow friction were examined. The numerical results indicate that the tubes with loose-fit multiple channel twisted tapes perform higher heat transfer rates than the plain tube. The enhanced heat transfer rate is escorted with larger pressure drop. Both heat transfer and pressure drop increase with increasing multiple channel number (N) and decreasing clearance ratio (CR). Heat transfer augmented by the loose-fit multiple channel twisted tape with N = 4 is higher than those enhanced by the ones with N = 2 and 3 by around 9.5-17.8% and 5.8-7.8%, respectively. In addition, the loose-fit multiple channel twisted tapes with clearance ratio of 0.025, 0.05, and 0.075 give lower heat transfer rates than the one with CR = 0.0 by around 8.4%, 17.5%, and 28.8%, respectively.