A theoretical study is presented herein on the pen- etration of a semi-infinite target by a spherical-headed long rod for Yp 〉 S, where Yp is the penetrator strength and S is the static target resistance. For Yp 〉 S...A theoretical study is presented herein on the pen- etration of a semi-infinite target by a spherical-headed long rod for Yp 〉 S, where Yp is the penetrator strength and S is the static target resistance. For Yp 〉 S, depending upon initial impact velocity, there exist three types of penetration, namely, penetration by a rigid long rod, penetration by a deforming non-erosive long rod and penetration by an erosive long rod. If the impact velocity of the penetrator is higher than the hydrodynamic velocity (VH), it will penetrate the target in an erosive mode; if the impact velocity lies between the hydrodynamic velocity (VH) and the rigid body velocity (VR), it will penetrate the target in a deformable mode; if the impact velocity is less than the rigid body velocity (VR), it will penetrate the target in a rigid mode. The critical conditions for the transition among these three penetration modes are proposed. It is demonstrated that the present model predictions correlate well with the experimental observations in terms of depth of penetration (DOP) and the critical transition conditions.展开更多
The polonium-210 activity in raw material targets which was used to make the start neutron source rods of Qinshan Nuclear Power Station was determined in calorimetry. The calorimeter used is a twin-cup isothermal one....The polonium-210 activity in raw material targets which was used to make the start neutron source rods of Qinshan Nuclear Power Station was determined in calorimetry. The calorimeter used is a twin-cup isothermal one. It works at room temperature and does not need any device of constant temperature. The instruments used for calorimetry are simple and have good properties. The background is from -1μV to + 2 μ V when the room temperature changs between 16℃ and 28 ℃. The data gotten in calorimetry are in correspondence within ±3.4 % with those from liquid scintillation method after the targets were dissolved, additionally in correspondence within ±1.7% with the data given by Amersham Laboratories for 241Am determination.展开更多
基金supported by the National Natural Science Foundation of China (10872195)
文摘A theoretical study is presented herein on the pen- etration of a semi-infinite target by a spherical-headed long rod for Yp 〉 S, where Yp is the penetrator strength and S is the static target resistance. For Yp 〉 S, depending upon initial impact velocity, there exist three types of penetration, namely, penetration by a rigid long rod, penetration by a deforming non-erosive long rod and penetration by an erosive long rod. If the impact velocity of the penetrator is higher than the hydrodynamic velocity (VH), it will penetrate the target in an erosive mode; if the impact velocity lies between the hydrodynamic velocity (VH) and the rigid body velocity (VR), it will penetrate the target in a deformable mode; if the impact velocity is less than the rigid body velocity (VR), it will penetrate the target in a rigid mode. The critical conditions for the transition among these three penetration modes are proposed. It is demonstrated that the present model predictions correlate well with the experimental observations in terms of depth of penetration (DOP) and the critical transition conditions.
文摘The polonium-210 activity in raw material targets which was used to make the start neutron source rods of Qinshan Nuclear Power Station was determined in calorimetry. The calorimeter used is a twin-cup isothermal one. It works at room temperature and does not need any device of constant temperature. The instruments used for calorimetry are simple and have good properties. The background is from -1μV to + 2 μ V when the room temperature changs between 16℃ and 28 ℃. The data gotten in calorimetry are in correspondence within ±3.4 % with those from liquid scintillation method after the targets were dissolved, additionally in correspondence within ±1.7% with the data given by Amersham Laboratories for 241Am determination.