In this paper,a probe method for nonlinear programming wiht equality and inequality is given. Its iterative directions at an arbitrary point x can be obtained through solving a liear system. The terminate conditions a...In this paper,a probe method for nonlinear programming wiht equality and inequality is given. Its iterative directions at an arbitrary point x can be obtained through solving a liear system. The terminate conditions and choices of the parameters are given. The global convergence of the method is proved. Further more,some well known gradient projection type algorithms [1-15] and new gradient projection type algorithms from the linear system are given in this paper.展开更多
The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of...The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of coarse sand,fine sand and silty clay in different water contents. The results that measured by the probe method are well consistent with those of QTM-D_2. The soil thermal conductivity increases in different levels with the increase of the water content. Compared the soil thermal conductivity measured by the probe method in laboratory with in-situ experiment,it shows that the measuring gap gradually increases with the increase of the depth. The reason is that the in-situ measuring thermal conductivity can reflect the actual situation of the soil mass.展开更多
A combined method for the fast 3-D finite element modeling of defect responses in nondestructive testing of electromagnetics is presented. The method consists of three numerical techniques: zoom-in technique, differen...A combined method for the fast 3-D finite element modeling of defect responses in nondestructive testing of electromagnetics is presented. The method consists of three numerical techniques: zoom-in technique, difference field technique and iterative solution technique. Utilizing the zoom-in technique, the computational zone focuses on a relatively small domain around the defect. Employing the difference field technique, the axisymmetrical field solution corresponding to the case with no defect can be used to simplify the mesh generation and obtain the modeling results quickly. Using the iterative solution technique, the matrix equation system in the 3-D finite element modeling of nondestructive probe signals can easily be solved. The sample calculation shows that the presented method is highly effective and can consequently save significant computer resources.展开更多
The deformation characteristic of bland in deep drawing is discussed. It is pointed out that the friction and lubrication conditions in for drawing are different from that in mechanical motion or machine work or other...The deformation characteristic of bland in deep drawing is discussed. It is pointed out that the friction and lubrication conditions in for drawing are different from that in mechanical motion or machine work or other plastic process. The common test methods in laboratories are analyzed. It shows that though all those test methods can test the friction coefficient, the probe test method is most suitable for the research of friction and lubrication and the process in deep drawing, for this method is identical with the actual work condition either from the test principle or deformation status of the blank. Last the successful application in the deep drawing simulator newly developed the the probe method are intro- duced in detail.展开更多
Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is...Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.展开更多
The contamination behavior of Langmuir probe in silane glow discharge plasma are discussed.A hot electrical probe is suggested to improve the diagnostics of SiH_(4) plasma.Results show the safe duration for reliable m...The contamination behavior of Langmuir probe in silane glow discharge plasma are discussed.A hot electrical probe is suggested to improve the diagnostics of SiH_(4) plasma.Results show the safe duration for reliable measurements of electron temperature can be as long as 40min by this method.展开更多
Brain tissue plays a significant role in both cognitive and psychomotor behavior of humans. However, their interaction with radiation emanating from hand held mobile devices is still not fully understood. This researc...Brain tissue plays a significant role in both cognitive and psychomotor behavior of humans. However, their interaction with radiation emanating from hand held mobile devices is still not fully understood. This research was aimed at investigating radiation absorption in brain tissue. Bovine brain tissues ranging from lesser than 1 year to greater than 10 years of age were bought from a specialty store (Sigma-Aldrich). The tissues were used within 72 h of extraction for ex vivo brain experiments. The brain tissue was stored at 6°C and then 16°C for 24 h in the MRI room to reach thermal equilibrium before any experiments were undertaken. The averages for the dielectric constant were measured from 1 - 4 GHz using open ended coaxial probe (OECP) (85,070E;Agilent Technologies). The results obtained for the dielectric properties were then used as raw data in the numerical computation and simulation of the radiation absorption by the brain tissues for both adolescent and adults bovine brain tissue using finite element method (FEM). The measured dielectric constants varied for the different brain tissue from 54.39 to 39.29. Analysis showed that adolescents tissue absorbed more radiation than adults from mobile phoneradiation which is due to the higher dielectric property of adolescent brain tissue. The results obtained can be applied to human brain tissue since bovine shares the same compositional properties with humans.展开更多
Experiments on specimens of mild steel and cast iron have beenperformed under vari- ous loading conditions. A modified formula isput forward to analyze the cruciform specimen which is often used inmagnetic methods for...Experiments on specimens of mild steel and cast iron have beenperformed under vari- ous loading conditions. A modified formula isput forward to analyze the cruciform specimen which is often used inmagnetic methods for calibration. We assume that the relationshipbetween the magnetic output and strain is linear and a newfour-coefficient method is deduced. Finally, the results of practi-cal applications are given.展开更多
The inverse scattering problems are to detect the property of obstacles from the measurements outside the obstacles. One of important research areas in this topic is the recovery of boundary property for impenetrable ...The inverse scattering problems are to detect the property of obstacles from the measurements outside the obstacles. One of important research areas in this topic is the recovery of boundary property for impenetrable obstacles. In this paper, we would like to give a brief review about the recently developed singular source methods. There are three different methods in this category, namely, linear sampling method, pointsource method and probe method. We also present some recent new results about the probe method.展开更多
为解决原子力显微镜(Atomic Force Microscope,AFM)系统更换探针后光路调整复杂耗时、精度不足的问题,本文首次提出通过精密控制探针与探针夹装配位置来实现更换的探针相对AFM系统原光路位置的一致,进而实现免去AFM系统换针后调整光路...为解决原子力显微镜(Atomic Force Microscope,AFM)系统更换探针后光路调整复杂耗时、精度不足的问题,本文首次提出通过精密控制探针与探针夹装配位置来实现更换的探针相对AFM系统原光路位置的一致,进而实现免去AFM系统换针后调整光路步骤。该系统的光路一致性组件采用光束偏转法对探针位置与偏转进行放大与监测,并使用高精度位移与角度调节平台进行探针相对于探针夹的方位调整。通过实物搭建对探针一致性效果进行了验证,并对紫外光(Ultraviolet,UV)胶水固化过程导致探针位置偏移影响;探针不同偏移量时产生的探测器噪音对AFM系统成像质量影响进行了系统分析。实验结果表明:经由该系统装配的探针平均位置精度接近1.1μm;并且在AFM系统中更换一致性探针仅需8 s。该系统实现了高精度且质量稳定的探针一致性装配,极大地简化了AFM系统重新校准光路的操作步骤,其与自动换针装置配合可有效提升工业计量型AFM的操作与测量性能。展开更多
文摘In this paper,a probe method for nonlinear programming wiht equality and inequality is given. Its iterative directions at an arbitrary point x can be obtained through solving a liear system. The terminate conditions and choices of the parameters are given. The global convergence of the method is proved. Further more,some well known gradient projection type algorithms [1-15] and new gradient projection type algorithms from the linear system are given in this paper.
基金Supported by Project of National Natural Science Foundation of China(No.41372239)
文摘The authors presented a new measuring method of the soil thermal conductivity,the probe method,which is designed and made based on the theory of line heat source. This method is used to measure thermal conductivity of coarse sand,fine sand and silty clay in different water contents. The results that measured by the probe method are well consistent with those of QTM-D_2. The soil thermal conductivity increases in different levels with the increase of the water content. Compared the soil thermal conductivity measured by the probe method in laboratory with in-situ experiment,it shows that the measuring gap gradually increases with the increase of the depth. The reason is that the in-situ measuring thermal conductivity can reflect the actual situation of the soil mass.
文摘A combined method for the fast 3-D finite element modeling of defect responses in nondestructive testing of electromagnetics is presented. The method consists of three numerical techniques: zoom-in technique, difference field technique and iterative solution technique. Utilizing the zoom-in technique, the computational zone focuses on a relatively small domain around the defect. Employing the difference field technique, the axisymmetrical field solution corresponding to the case with no defect can be used to simplify the mesh generation and obtain the modeling results quickly. Using the iterative solution technique, the matrix equation system in the 3-D finite element modeling of nondestructive probe signals can easily be solved. The sample calculation shows that the presented method is highly effective and can consequently save significant computer resources.
文摘The deformation characteristic of bland in deep drawing is discussed. It is pointed out that the friction and lubrication conditions in for drawing are different from that in mechanical motion or machine work or other plastic process. The common test methods in laboratories are analyzed. It shows that though all those test methods can test the friction coefficient, the probe test method is most suitable for the research of friction and lubrication and the process in deep drawing, for this method is identical with the actual work condition either from the test principle or deformation status of the blank. Last the successful application in the deep drawing simulator newly developed the the probe method are intro- duced in detail.
文摘Previous works have shown that the suction probe cannot be used to accurately measure the upward and downward particle fluxes independently. A new method using a single optical probe to measure the local solid flux is presented. The measurement of upward, downward and net solid fluxes was carried out in a cold model circulating fluidized bed (CFB) unit. The result shows that the profile of the net solid flux is in good agreement with the previous experimental data measured with a suction probe. The comparison between the average solid flux determined with the optical measuring system and the external solid flux was made, and the maximum deviationturned out to be 22%, with the average error being about 6.9%. These confirm that the optical fiber system can be successfully used to measure the upward, downward and net solid fluxes simultaneously by correctly processing the sampling signals obtained from the optical measuring system.
基金Supported by the National Natural Science Foundation of China.
文摘The contamination behavior of Langmuir probe in silane glow discharge plasma are discussed.A hot electrical probe is suggested to improve the diagnostics of SiH_(4) plasma.Results show the safe duration for reliable measurements of electron temperature can be as long as 40min by this method.
文摘Brain tissue plays a significant role in both cognitive and psychomotor behavior of humans. However, their interaction with radiation emanating from hand held mobile devices is still not fully understood. This research was aimed at investigating radiation absorption in brain tissue. Bovine brain tissues ranging from lesser than 1 year to greater than 10 years of age were bought from a specialty store (Sigma-Aldrich). The tissues were used within 72 h of extraction for ex vivo brain experiments. The brain tissue was stored at 6°C and then 16°C for 24 h in the MRI room to reach thermal equilibrium before any experiments were undertaken. The averages for the dielectric constant were measured from 1 - 4 GHz using open ended coaxial probe (OECP) (85,070E;Agilent Technologies). The results obtained for the dielectric properties were then used as raw data in the numerical computation and simulation of the radiation absorption by the brain tissues for both adolescent and adults bovine brain tissue using finite element method (FEM). The measured dielectric constants varied for the different brain tissue from 54.39 to 39.29. Analysis showed that adolescents tissue absorbed more radiation than adults from mobile phoneradiation which is due to the higher dielectric property of adolescent brain tissue. The results obtained can be applied to human brain tissue since bovine shares the same compositional properties with humans.
文摘Experiments on specimens of mild steel and cast iron have beenperformed under vari- ous loading conditions. A modified formula isput forward to analyze the cruciform specimen which is often used inmagnetic methods for calibration. We assume that the relationshipbetween the magnetic output and strain is linear and a newfour-coefficient method is deduced. Finally, the results of practi-cal applications are given.
文摘The inverse scattering problems are to detect the property of obstacles from the measurements outside the obstacles. One of important research areas in this topic is the recovery of boundary property for impenetrable obstacles. In this paper, we would like to give a brief review about the recently developed singular source methods. There are three different methods in this category, namely, linear sampling method, pointsource method and probe method. We also present some recent new results about the probe method.
文摘为解决原子力显微镜(Atomic Force Microscope,AFM)系统更换探针后光路调整复杂耗时、精度不足的问题,本文首次提出通过精密控制探针与探针夹装配位置来实现更换的探针相对AFM系统原光路位置的一致,进而实现免去AFM系统换针后调整光路步骤。该系统的光路一致性组件采用光束偏转法对探针位置与偏转进行放大与监测,并使用高精度位移与角度调节平台进行探针相对于探针夹的方位调整。通过实物搭建对探针一致性效果进行了验证,并对紫外光(Ultraviolet,UV)胶水固化过程导致探针位置偏移影响;探针不同偏移量时产生的探测器噪音对AFM系统成像质量影响进行了系统分析。实验结果表明:经由该系统装配的探针平均位置精度接近1.1μm;并且在AFM系统中更换一致性探针仅需8 s。该系统实现了高精度且质量稳定的探针一致性装配,极大地简化了AFM系统重新校准光路的操作步骤,其与自动换针装置配合可有效提升工业计量型AFM的操作与测量性能。