期刊文献+
共找到8,445篇文章
< 1 2 250 >
每页显示 20 50 100
Elevational patterns of temperature and humidity in the middle Tianshan Mountain area in Central Asia 被引量:1
1
作者 Gheyur GHEYRET Anwar MOHAMMAT TANG Zhi-yao 《Journal of Mountain Science》 SCIE CSCD 2020年第2期397-409,共13页
The vertical distribution of vegetation types along an elevational gradient in mountain areas largely depends on the elevational changes in air temperature and humidity. In this study, we presented the seasonal and di... The vertical distribution of vegetation types along an elevational gradient in mountain areas largely depends on the elevational changes in air temperature and humidity. In this study, we presented the seasonal and diurnal variations in the elevational gradients of air temperature and humidity on the southern and northern slopes in the middle Tianshan Mountain Range using data collected throughout the year via HOBO data loggers. The measurements were conducted at 12 different elevations from 1548 to 3277 m from September 2004 to August 2005. The results showed that the annual mean air temperature decreased along the elevational gradients with temperature lapse rates of(0.71±0.20)°C/100 m and(0.59±0.05)°C/100 m on the northern and southern slopes, respectively. The annual mean absolute humidity significantly decreased with increasing elevation on the northern slope but showed no significant trend on the southern slope. The annual mean relative humidity did not show a significant trend on the northern slope but increased with increasing elevation on the southern slope. The mean air temperature lapse rate exhibited significant seasonal variation, which is steeper insummer and shallower in winter, and this value varied between 0.37°C/100 m and 0.75°C/100 m on the southern slope and between 0.30°C/100 m and 1.02°C/100 m on the northern slope. The mean absolute and relative humidity also exhibited significant seasonal variations on both slopes, with the maximum occurring in summer and the minimum occurring in winter or spring. The monthly diurnal range of air temperature on both slopes was higher in spring than in winter. The annual range of air temperature on the southern slope was higher than that on the northern slope. Our results suggest that significant spatiotemporal variations in humidity and temperature lapse rate are useful when analyzing the relationships between species range sizes and climate in mountain areas. 展开更多
关键词 temperature lapse rate Absolute humidity Relative humidity Annual range of temperature Diurnal range of temperature HOBO data loggers
下载PDF
Impact of Relative Humidity of Supply Gas on Temperature Distributions in Single Cell of Polymer Electrolyte Fuel Cell When Operated at High Temperature 被引量:2
2
作者 Akira Nishimura Masato Yoshimura +2 位作者 Satoru Kamiya Masafumi Hirota Eric Hu 《Journal of Energy and Power Engineering》 2017年第11期706-718,共13页
For improving the performance of stationary PEFC (polymer electrolyte fuel cell) system, the cell operating temperature up to 90℃ will be preferred in Japan during the period from 2020 to 2030. To understand the op... For improving the performance of stationary PEFC (polymer electrolyte fuel cell) system, the cell operating temperature up to 90℃ will be preferred in Japan during the period from 2020 to 2030. To understand the operation of the PEFC system under relatively high temperature conditions, detail heat and mass transfer analysis is required. The purpose of this study is to analyze the impact of relative humidity of supply gas on temperature distribution on the backside of separator in single ceil of PEFC using Nation membrane at higher temperature e.g. 90℃. The in-plane temperature distribution when power was being generated was measured using thermograph with various relative humidity of supply gases. It was found that the in-plane temperature distribution at the anode was more even than that at the cathode irrespective of the relative humidity of supply gas at the anode and the cathode. The temperature elevated along gas flow through the gas channel at the cathode irrespective of relative humidity of supply gas at the anode and the cathode. The in-plane temperature distribution at the cathode was narrower with the increase in Tini irrespective of relative humidity of supply gas at the cathode, while it was not observed when changing the relative humidity of supply gas at the anode. When the relative humidity of supply gas at cathode decreased, the in-plane temperature distribution at the anode was wider compared to decreasing the relative humidity of supply gas at the anode. The study concluded that the impact of relative humidity of supply gas at both anode and cathode had little impact on the in-plane temperature distribution at the cathode. 展开更多
关键词 PEFC temperature distribution high temperature operation relative humidity.
下载PDF
Study on Temperature and Humidity of Plastic Greenhouse under Different Ventilation Modes in the Yangtze-Huai Region in Hot Season 被引量:1
3
作者 孟力力 刘建龙 +3 位作者 柳军 夏礼如 唐玉邦 虞利俊 《Agricultural Science & Technology》 CAS 2016年第12期2885-2888,2900,共5页
In order to analyze the ventilation and cooling performance of single-tunnel plastic greenhouse in Yangtze-Huai region, the effects of two different ventilation modes (side window, side window+roof window) on the t... In order to analyze the ventilation and cooling performance of single-tunnel plastic greenhouse in Yangtze-Huai region, the effects of two different ventilation modes (side window, side window+roof window) on the temperature and humidity of plastic greenhouse were studied. The results showed that the ventilation mode of opening side window and roof window could effectively reduce the temperature and humidity at the plant canopy height, which was conducive to the growth of plant in greenhouse. 展开更多
关键词 Plastic greenhouse temperature humidity Ventilation COOLING
下载PDF
One-Dimensional Variational Retrieval of Temperature and Humidity Profiles from the FY4A GIIRS 被引量:4
4
作者 Qiumeng XUE Li GUAN Xiaoning SHI 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2022年第3期471-486,共16页
A physical retrieval approach based on the one-dimensional variational(1 D-Var) algorithm is applied in this paper to simultaneously retrieve atmospheric temperature and humidity profiles under both clear-sky and part... A physical retrieval approach based on the one-dimensional variational(1 D-Var) algorithm is applied in this paper to simultaneously retrieve atmospheric temperature and humidity profiles under both clear-sky and partly cloudy conditions from FY-4 A GIIRS(geostationary interferometric infrared sounder) observations. Radiosonde observations from upper-air stations in China and level-2 operational products from the Chinese National Satellite Meteorological Center(NSMC)during the periods from December 2019 to January 2020(winter) and from July 2020 to August 2020(summer) are used to validate the accuracies of the retrieved temperature and humidity profiles. Comparing the 1 D-Var-retrieved profiles to radiosonde data, the accuracy of the temperature retrievals at each vertical level of the troposphere is characterized by a root mean square error(RMSE) within 2 K, except for at the bottom level of the atmosphere under clear conditions. The RMSE increases slightly for the higher atmospheric layers, owing to the lack of temperature sounding channels there.Under partly cloudy conditions, the temperature at each vertical level can be obtained, while the level-2 operational products obtain values only at altitudes above the cloud top. In addition, the accuracy of the retrieved temperature profiles is greatly improved compared with the accuracies of the operational products. For the humidity retrievals, the mean RMSEs in the troposphere in winter and summer are both within 2 g kg^(–1). Moreover, the retrievals performed better compared with the ERA5 reanalysis data between 800 h Pa and 300 h Pa both in summer and winter in terms of RMSE. 展开更多
关键词 temperature and humidity profiles one-dimensional variational(1D-Var) GIIRS hyperspectral data
下载PDF
Mesocosmic study on autogenous shrinkage of concrete with consideration of effects of temperature and humidity 被引量:1
5
作者 Yan HAI Yue-ming ZHU 《Water Science and Engineering》 EI CAS 2009年第4期85-94,共10页
A study on the autogenous shrinkage (AS) of concrete from a mesocosmic perspective was carried out using numerical simulation technology. The temperature history and the autogenous relative humidity (ARH), two fac... A study on the autogenous shrinkage (AS) of concrete from a mesocosmic perspective was carried out using numerical simulation technology. The temperature history and the autogenous relative humidity (ARH), two factors that have been shown to have occasional influence on this process in previous studies, were introduced into this study. According to these concepts, a program for simulation of the temperature field, humidity field, and stress field based on the equivalent age method and a fully automatic aggregate modeling tool were used. With the help of these programs, the study of a small concrete specimen provided some useful conclusions: the aggregate and the matrix show distinct distribution properties in the temperature field, humidity field, and stress field; the aggregate-matrix interface has a high possibility of becoming the location of the initial cracking caused by AS of concrete; the distribution of random aggregates is extremely important for mesoscopical analysis; and the temperature history is the main factor affecting the AS of concrete. On the whole, inherent mechanisms and cracking mechanisms of AS of concrete can be explained more reasonably and realistically only by considering the different characteristics of material phases and the effects of temperature and humidity. 展开更多
关键词 CONCRETE autogenous shrinkage meso-analysis equivalent age temperature history autogenous relative humidity
下载PDF
Comparisons of the temperature and humidity profiles of reanalysis products with shipboard GPS sounding measurements obtained during the 2018 Eastern Indian Ocean Open Cruise 被引量:3
6
作者 WANG Lei BAO Qing +4 位作者 LI Jinxiao WANG Dongxiao LIU Yimin WU Guoxiong WU Xiaofei 《Atmospheric and Oceanic Science Letters》 CSCD 2019年第3期177-183,共7页
It is important to be able to characterize the thermal conditions over the equatorial Indian Ocean for both weather forecasting and climate prediction. This study compared the equatorial eastern Indian Ocean (EEIO) te... It is important to be able to characterize the thermal conditions over the equatorial Indian Ocean for both weather forecasting and climate prediction. This study compared the equatorial eastern Indian Ocean (EEIO) temperature and relative humidity profiles from three reanalysis products (JRA-55, MERRA2, and FGOALS-f2) with shipboard global positioning system (GPS) sounding measurements obtained during the Eastern Indian Ocean Open Cruise in spring 2018. The FGOALS-f2 reanalysis product is based on the initialization module of a sub-seasonal to seasonal prediction system with a nudging-based data assimilation method. The results indicated that:(1) both JRA-55 and MERRA2 were reliable in characterizing the temperature profile from 850 to 600 hPa, with a maximum deviation of about <0.5℃. Both datasets showed a large negative deviation below 825 hPa, with a maximum bias of about 2℃ at 1000 hPa and 1.5℃ at 900 hPa, respectively.(2) JRA-55 showed good performance in characterizing the relative humidity profile above 850 hPa, with a maximum deviation of < 8%, while it showed much wetter conditions below 850 hPa. MERRA2 overestimated the relative humidity in the middle to lower troposphere, with a maximum deviation of about 15% at 925 hPa.(3) The FGOALS-f2 reanalysis product more accurately reproduced the temperature profile in the marine atmospheric boundary layer over the EEIO than that in JRA-55 and MERRA2, but showed much wetter conditions than the GPS sounding observations, with a maximum deviation of up to 20% at 600 hPa. Future applications of GPS sounding datasets are discussed. 展开更多
关键词 GPS sounding measurements equatorial eastern Indian Ocean temperature and humidity profiles reanalysis datasets characterization of performance
下载PDF
ACCURACY OF THE RETRIEVED TEMPERATURE AND HUMIDITY FIELDS FOR TYPHOON HAIYAN UTILIZING THE ADVANCED TECHNOLOGY MICROWAVE SOUNDER 被引量:1
7
作者 盛文杰 刘健文 黄江平 《Journal of Tropical Meteorology》 SCIE 2017年第4期408-416,共9页
One-dimensional retrieval was performed on Typhoon Haiyan utilizing the advanced technology microwave sounder onboard the satellite Suomi NPP to retrieve the temperature and water vapor profiles of the typhoon.Compari... One-dimensional retrieval was performed on Typhoon Haiyan utilizing the advanced technology microwave sounder onboard the satellite Suomi NPP to retrieve the temperature and water vapor profiles of the typhoon.Comparisons of the retrieved profiles and ECMWF reanalysis were made to assess the results. The main conclusions are as follows.(1) The results have high spatial resolution and therefore can precisely represent the temperature and humidity distribution of the typhoon.(2) The retrieved temperature is low in the areas of low temperature and high in the areas of high temperature; similar patterns are observed for humidity. This means that systematic revision may be needed during routine application.(3) The results of the retrieved temperature and humidity profiles are generally accurate, which is quite important for typhoon monitoring. 展开更多
关键词 1-D VAR retrieving algorithm temperature and humidity profiles ATMS NPP Typhoon Haiyan
下载PDF
Reciprocal Analysis of Sensible and Latent Heat Fluxes in a Forest Region Using Single Height Temperature and Humidity Based on the Bowen Ratio Concept 被引量:2
8
作者 Toshisuke Maruyama Manabu Segawa 《Journal of Water Resource and Protection》 2016年第7期724-742,共19页
Evapotranspiration in forests has been researched for a long time because it serves an important role in water resource issues and biomass production. By applying the reciprocal analysis based on the Bowen ratio conce... Evapotranspiration in forests has been researched for a long time because it serves an important role in water resource issues and biomass production. By applying the reciprocal analysis based on the Bowen ratio concept to the canopy surface, the sum result of sensible and latent heat fluxes, i.e., actual evapotranspiration (ET), is estimated from engineering aspect using the net radiation (Rn) and heat flux into the ground (G). The new method uses air temperature and humidity at a single height by determining the relative humidity (rehs) using the canopy temperature (Ts). The validity of the method is confirmed by the latent heat flux (lE) and sensible heat flux (H) observed by mean of eddy covariance method. The heat imbalance is corrected by multiple regression analysis. The temporal change of lE and H at the canopy surface is clarified using hourly and yearly data. Furthermore, the observed and estimated monthly evapotranspiration of the sites are compared. The research is conducted using hourly data and the validation of the method is conducted using observed covariance at five sites in the world using FLUXNET. 展开更多
关键词 Bowen Ratio Eddy Covariance Reciprocal Determination Estimation of Evapotranspiration Canopy Surface temperature and humidity
下载PDF
THE DISTRIBUTION REGION AND THE DISTRIBUTIVE TEMPERATURE AND HUMIDITY THRESHOLD OF OSIER WEEVIL IN CHINA
9
作者 段立清 《Journal of Northeast Forestry University》 SCIE CAS CSCD 1995年第2期50-53,共4页
A distribution map of osier weevil (Crytorrynchus lapathi L.) was drown up based on widely collecting information and field survey. The results showed that Osier weevil has a widespread in China, stretching from 33&#... A distribution map of osier weevil (Crytorrynchus lapathi L.) was drown up based on widely collecting information and field survey. The results showed that Osier weevil has a widespread in China, stretching from 33°21' to 51°42' N latitude and 83°00' to 132°58' E longitude, and distributes in forms of big or small patches or sports uncontinously. According to the analysis of meteorological data, the temperature and humidity threshold for osier weevil's distribution were determined by methods of PCA (Principle Component Analysis) and RA(Relativity Analysis): January temperature is -30~ 0℃. Annual temperature -4~13℃, Annual precipitation from 411~ 1,136 min.The areas with January temperature under 0℃, annual temperature above 0℃ and annual precipitation of 400~ 800 mm are the optimum distributing places for osier weevil in China. 展开更多
关键词 Osier weevil Cryptorrynchus lapath Distribution region temperature and humidity threshold
下载PDF
Effects of Temperature and Humidity Changes inside and outside Insect-proof Net in the Spring on the Spring Shoot Growth of Citrus Shatangju
10
作者 Xiaofeng ZHANG Yanjun GUO +4 位作者 Hui JIANG Liying GUO Xiqin ZHOU Yaping HU Qianhua JI 《Asian Agricultural Research》 2018年第1期69-72,共4页
The experiment was mainly used to study the effect of insect-proof net mulching cultivation technology on the temperature and humidity of the greenhouse and the spring shoot growth of citrus Shatangju. The results sho... The experiment was mainly used to study the effect of insect-proof net mulching cultivation technology on the temperature and humidity of the greenhouse and the spring shoot growth of citrus Shatangju. The results showed that the 40-mesh translucent insect-proof net had a positive effect on the spring shoot growth of Shatangju in the spring from January to April. In the meantime,according to the change of the temperature and humidity inside and outside the insect-proof net and the change of quantity of Aleyrodidae,Tetranychidae and Phyllocnisidae,it was found that the role of insect-proof net in enhancing the spring shoot growth of Shatangju was possibly achieved by the regulation of citrus pests and the temperature and humidity inside the net. 展开更多
关键词 Insect-proof net Citrus Shatangju Spring shoot temperature and humidity Citrus pests
下载PDF
PRELIMINARY STUDY OF INDOOR FEATURES OF TEMPERATURE AND HUMIDITY FOR ROOMS FACING NORTH-SOUTH IN WINTER IN A LOW-LATITUDE PLATEAU CITY
11
作者 张一平 李佑荣 +2 位作者 王进欣 刘玉洪 马友鑫 《Journal of Tropical Meteorology》 SCIE 2002年第1期85-92,共8页
Analyzing observations of wintertime air temperature in both indoor and outdoor surroundings in Kunming, a city lying in low latitudes, characteristics of temperature and humidity have been studied for the interior of... Analyzing observations of wintertime air temperature in both indoor and outdoor surroundings in Kunming, a city lying in low latitudes, characteristics of temperature and humidity have been studied for the interior of rooms facing north-south under different weather conditions. Significant warming effect has been identified in terms of lowest and daily-mean indoor temperature in the area of Kunming. The heating amplitude ranges from 7.7C to 10.0C and from 4.6C to 5.8C for the interior part of rooms facing the south and from 4.6C to 7.0C and from 1.3C to 4.4C for the interior part of rooms facing the north, respectively for the two elements. The highest air temperature is higher indoor than outdoor for rooms facing the south, but otherwise is usually true for rooms facing the north. Additional findings point out that buildings not only help maintain relatively warm indoor temperature but delay its variation. The diurnal cycle of temperature indoor is smaller and ranges by 40% ~ 48% for south-facing rooms, and by 20% ~ 30% for north-facing rooms, than outdoor, and the highest temperature is about 2 hours late inside the room than outside. It shows how inertly indoor temperature varies. The work also finds that relative humidity is less indoor in southward rooms than in northward ones and difference is the largest on fine days but the smallest when it is overcast. For the diurnal variation, the indoor relative humidity is large at nighttime with small amplitude but small during daytime with large amplitude. The above-presented results can be served as scientific foundation for more research on climate in low-latitude cities and rational design of urban architectures. 展开更多
关键词 orientation of room air temperature and humidity different weather condition WINTER low-latitude plateau city
下载PDF
Equivalent materials simulation experimental study on bed separations developing and mining subsidence in constant humidity and constant temperature conditions
12
作者 付志亮 王素华 高延法 《Journal of Coal Science & Engineering(China)》 2008年第4期585-590,共6页
A new experiment was made on the developing of bed separations and mining subsidence from Tangshan T2192 working face by equivalent materials simulation.The overburden deformation and the developing of bed separations... A new experiment was made on the developing of bed separations and mining subsidence from Tangshan T2192 working face by equivalent materials simulation.The overburden deformation and the developing of bed separations with working face advanc- ing was simulated by a new model.The results show that the maximum value of bed separations moved forward gradually along with the working face advancing;the maxi- mum value of bed separations is 0.31~0.50 times of mining thickness.The key strata have a great influence upon surface subsidence during the overburden movement process.The mechanics parameters of new experiment are fitted with results in fields perfectly. 展开更多
关键词 SUBSIDENCE bed separations constant humidity constant temperature equivalent simulation experiment
下载PDF
Wireless sensing system for environmental humidity and temperature monitoring
13
作者 袁耀东 张爱军 《Journal of Measurement Science and Instrumentation》 CAS 2013年第3期267-271,共5页
Aiming at the actual demand for monitoring environmental information,a wireless sensing system for temperature and relative humidity(RH)monitoring based on radio frequency(RF)technology and mobile network was designed... Aiming at the actual demand for monitoring environmental information,a wireless sensing system for temperature and relative humidity(RH)monitoring based on radio frequency(RF)technology and mobile network was designed.This paper introduces the architecture of the system.The system uses AVR micro controller unit(MCU),KYL-1020U RF module and SHT71 to complete real-time temperature and humidity monitoring,and uses SIM900A module to realize remote alarming and monitoring with short message system(SMS)through global system for mobile communication(GSM).Experimental results show that the designed system has good stability of measurement and real-time performance,and it can be used in some small temperature and humidity monitoring occasions. 展开更多
关键词 environmental monitoring temperature and humidity radio frequency (RF) technology wireless transmission global system for mobile communication (GSM)CLC number:TP274 Document code:AArticle ID:1674-8042(2013)03-0267-05
下载PDF
Application of Intelligent Blood Temperature and Humidity Monitoring System in Blood Station
14
作者 Shengwang Chen Zhenquan Ning +1 位作者 Wenlong Lin Shanchang Chen 《Natural Science》 2022年第5期186-192,共7页
Objective: To explore the application of intelligent blood temperature and humidity monitoring system in cold chain management of blood station. Methods: Through the monitoring of fifty sets of cold-chain equipment in... Objective: To explore the application of intelligent blood temperature and humidity monitoring system in cold chain management of blood station. Methods: Through the monitoring of fifty sets of cold-chain equipment in the central blood station in Hezhou for 6 months, the differences between the management of the automatic temperature and humidity monitoring system and the manual management were compared in terms of real-time recording, equipment alarm, data storage, historical data traceability and data analysis. Results: Temperature and humidity automatic monitoring system can automatically real-time acquisition, transmission, storage and alarm according to the required time interval;meanwhile, historical data can be quickly exported and traced, data and charts can be analyzed, and the alarm is real-time and effective. Conclusion: The system can effectively monitor the process of blood cold chain in blood stations and play a key role in ensuring blood quality. It can be popularized and used in blood stations. 展开更多
关键词 BLOOD temperature and humidity Automatic Monitoring SYSTEM
下载PDF
Design of greenhouse temperature and humidity wireless control system based on CC3200
15
作者 ZHAO Cheng-cheng DING Hai-fei +1 位作者 LIU Wen-yi KANG Xi 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2018年第2期134-139,共6页
Referring to the shortages that the process of traditional greenhouse measurement by using thermometer and hygrometer is complex,the measurement result is not accurate,and the control system operation is cumbersome,a ... Referring to the shortages that the process of traditional greenhouse measurement by using thermometer and hygrometer is complex,the measurement result is not accurate,and the control system operation is cumbersome,a greenhouse temperature and humidity(TH)control system based on CC3200 is designed.The system uses FPGA as the main controller,sends the TH signals to the wireless module CC3200 by controlling DHT22.The proposed system realizes the remote transmission of data and the automatic control of system. 展开更多
关键词 field programmable gate array(FPGA) CC3200 DHT22 temperature and humidity(TH)of greenhouse wireless control
下载PDF
Effects of Extreme Air Temperature and Humidity on the Insecticidal Expression Level of Bt Cotton 被引量:12
16
作者 CHENYuan WEN Yu-jin +5 位作者 CHEN Yuan John Tom Cothren ZHANG Xiang WANG Yong-hui WilliamA Payne CHEN De-hua 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2012年第11期1836-1844,共9页
The higher survival rates of Helicoverpa amigera larvae were usually observed after adverse climate which was related to extreme temperature (T) and relative humidity (RH) stresses in transgenic Bacillus thuringie... The higher survival rates of Helicoverpa amigera larvae were usually observed after adverse climate which was related to extreme temperature (T) and relative humidity (RH) stresses in transgenic Bacillus thuringiensis (Bt) cotton. The unstable resistance of Bt cotton to bollworms has been correlated with the reduced expression of CrylAc δ-endotoxin. The objective of this study was to investigate the effects of combined temperature and relative humidity stresses on the leaf CrylAc insecticidal protein expression during critical developmental stages. The study was undertaken on two transgenic cotton cultivars that share same parental background, Sikang 1 (a conventional cultivar) and Sikang 3 (a hybrid cultivar), during the 2007 and 2008 growing seasons at the Yangzhou University Farm, Yangzhou, China. The study was arranged with two factors that consisted of temperature (two levels) and relative humidity (three levels). The six T/RH treatments were 37℃/95%, 37℃/70%, 37℃/50%, 18℃/95%, 18℃/70%, and 18℃/50%. In 2007, the six treatments were imposed to the plants at peak flowering stage for 24 h; in 2008, the six treatments were applied to the plants at peak square, peak flowering, and peak boll stages for 48 h. The results of the study indicated that the leaf insecticidal protein expression in CrylAc was significantly affected by extreme temperature only at peak flowering stage, and by both extreme temperature and relative humidity during boll filling stage. The greatest reductions were observed when the stresses were applied at peak boll stage. In 2008, after 48 h stress treatment, the leaf Bt endotoxin expression reduced by 25.9-36.7 and 23.6-40.5% at peak boll stage, but only by 14.9-26.5 and 12.8-24.0% at peak flowering stage for Sikang 1 and Sikang 3, respectively. The greatest reduction was found under the low temperature combined with low relative humidity condition for both years. It is believed that the temperature and relative humidity stresses may be attributed to the reduced efficacy of Bt cotton in growing conditions in China, where extreme temperatures often increase up to 35-40℃ and/or decrease down to 15-20℃, and relative humidity may reach to 85-95% and/or reduce to 40-55% during the cotton growing season. 展开更多
关键词 Bt cotton high temperature low temperature relative humidity CryIAc protein
下载PDF
Spatial distribution of air temperature and relative humidity in the greenhouse as affected by external shading in arid climates 被引量:9
17
作者 Hesham AAhmed TONG Yu-xin +2 位作者 YANG Qi-chang Abdulellah AAl-Faraj Ahmed MAbdel-Ghany 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2019年第12期2869-2882,共14页
The effect of external roof shading on the spatial distribution of air temperature and relative humidity in a greenhouse(Tin and RHin) was evaluated under the arid climatic conditions of Riyadh City, Saudi Arabia. Two... The effect of external roof shading on the spatial distribution of air temperature and relative humidity in a greenhouse(Tin and RHin) was evaluated under the arid climatic conditions of Riyadh City, Saudi Arabia. Two identical, evaporatively-cooled, single-span greenhouses were used in the experiment. One greenhouse was externally shaded(Gs) using a movable black plastic net(30% transmissivity), and the other greenhouse was kept without shading(Gc). Strawberry plants were cultivated in both greenhouses. The results showed that the spatial distribution of the Tin and RHin was significantly affected by the outside solar radiation and evaporative cooling operation. The regression analysis showed that when the outside solar radiation intensity increased from 200 to 800 W m–2, the Tin increased by 4.5℃ in the Gc and 2℃in the Gs, while the RHin decreased by 15% in the Gc and 5% in the Gs, respectively. Compared with those in the Gc, more uniformity in the spatial distribution of the Tin and RHin was observed in the Gs. The difference between the maximum and minimum Tin of 6.4℃ and the RHin of 10% was lower in the Gs than those in the Gc during the early morning. Around 2℃ difference in the Tin was shown between the area closed to the exhausted fans and the area closed to the cooling pad with the external shading. In an evaporatively-cooled greenhouse in arid regions, the variation of the Tin and RHin in the vertical direction and along the sidewalls was much higher than that in the horizontal direction. The average variation of the Tin and RHin in the vertical direction was 5.2℃ and 10% in the Gc and 5.5℃ and 13% in the Gs, respectively. The external shading improved the spatial distribution of the Tin and RHin and improved the cooling efficiency of the evaporative cooling system by 12%, since the transmitted solar radiation and accumulated thermal energy in the greenhouse were significantly reduced. 展开更多
关键词 GREENHOUSE temperature humidity distribution UNIFORMITY EVAPORATIVE cooling SHADING ARID climate
下载PDF
Circadian Rhythm of Calling Behavior in the Emei Music Frog(Babina daunchina) is Associated with Habitat Temperature and Relative Humidity 被引量:12
18
作者 Jianguo CUI Xiaoyan SONG +3 位作者 Guangzhan FANG Fei XU Steven E. BRAUTH Yezhong TANG 《Asian Herpetological Research》 SCIE 2011年第3期149-154,共6页
Generally, the function of vocalizations made by male anurans are to attract females or defend resources. Typically, males vocalize in choruses during one or more periods in a twenty-four-hour cycle, which varies, how... Generally, the function of vocalizations made by male anurans are to attract females or defend resources. Typically, males vocalize in choruses during one or more periods in a twenty-four-hour cycle, which varies, however, among species. Nevertheless, the causal factors influencing circadian variations of calling patterns in anuran species are not clear. In this study, male chorus vocalizations were monitored in the Emei music frog(Babina daunchina) for 17 consecutive days during the breeding season, while its habitat air temperature and relative humidity in the course of experiments were measured as well. The results revealed that the circadian calling patterns were characterized by two periods of peak vocalization, which were observed from 0500 h to 0700 h and from 1300 h to 2000 h, while the lowest activity period was found from 2100 h to 2200 h. Both calls/h and notes/h were positively correlated with air temperature and negatively with relative humidity. Overall, our data indicate that the Emei music frogs(B. daunchina) could regulate their vocal activities based on the changes of physical micro-environment(e. g., temperature or humidity) to maximize reproductive success. 展开更多
关键词 rest-activity cycle advertisement call temperature humidity Emei music frog(Babina daunchina
下载PDF
Seasonal Variation in Air Temperature and Relative Humidity on Building Areas and in Green Spaces in Beijing, China 被引量:9
19
作者 KUANG Wenhui 《Chinese Geographical Science》 SCIE CSCD 2020年第1期75-88,共14页
The cooling and humidifying effects of urban parks are an essential component of city ecosystems in terms of regulating microclimates or mitigating urban heat islands(UHIs).Air temperature and relative humidity are tw... The cooling and humidifying effects of urban parks are an essential component of city ecosystems in terms of regulating microclimates or mitigating urban heat islands(UHIs).Air temperature and relative humidity are two main factors of thermal environmental comfort and have a critical impact on the urban environmental quality of human settlements.We measured the 2-m height air temperature and relative humidity at the Beijing Olympic Park and a nearby building roof for more than 1 year to elucidate seasonal variations in air temperature and relative humidity,as well as to investigate the outdoor thermal comfort.The results showed that the lawn of the park could,on average,reduce the air temperature by(0.80±0.19)℃,and increase the relative humidity by(5.24±2.91)% relative to the values measured at the building roof during daytime.During the nighttime,the lawn of the park reduced the air temperature by(2.64±0.64)℃ and increased the relative humidity by(10.77±5.20)%.The park was cooler and more humid than surrounding building area,especially in night period(more pronounced cooling with 1.84℃).Additionally,the lawn of the park could improve outdoor thermal comfort through its cooling and humidifying effects.The level of thermal comfort in the park was higher than that around the building roof for a total of 11 days annually in which it was above one or more thermal comfort levels(average reduced human comfort index of 0.92)except during the winter. 展开更多
关键词 air temperature relative humidity outdoor thermal comfort urban park planning
下载PDF
Visco-elastic-plastic model of deep underground rock affected by temperature and humidity 被引量:9
20
作者 GAO, Yanan GAO, Feng +1 位作者 ZHANG, Zhizhen ZHANG, Tao 《Mining Science and Technology》 EI CAS 2010年第2期183-187,共5页
As the depth of exploitation increases,studies on constitutive models of rock affected by temperature and humidity become very important.Based on the Nishihara model,a visco-elastic-plastic rock model was established ... As the depth of exploitation increases,studies on constitutive models of rock affected by temperature and humidity become very important.Based on the Nishihara model,a visco-elastic-plastic rock model was established by using the coefficients of thermal and humidity expansion,thermal viscosity attenuation,humid viscosity attenuation and acceleration rheology components.We used the definition of a controlled heat circle to explain the model.The results show that the behavior of rock,affected by temperature and humidity,is stable as a function of time when the stress is lower than the first yield stress σS1;the creep rate will increase due to the effect of temperature and humidity when the stress is greater than or equal to σS1;the creep rate will accelerate at an increasing rate when the stress is greater than or equal to the second yield stress σS2,which results in a failure of the roadway.The model derived in this study can completely describe visco-elastic-plastic characteristics and reflects the three stages of rock creep. 展开更多
关键词 temperature humidity CREEP controlled heat circle
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部