期刊文献+
共找到20,861篇文章
< 1 2 250 >
每页显示 20 50 100
On-Chip Micro Temperature Controllers Based on Freestanding Thermoelectric Nano Films for Low-Power Electronics
1
作者 Qun Jin Tianxiao Guo +4 位作者 Nicolas Perez Nianjun Yang Xin Jiang Kornelius Nielsch Heiko Reith 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第7期98-108,共11页
Multidimensional integration and multifunctional com-ponent assembly have been greatly explored in recent years to extend Moore’s Law of modern microelectronics.However,this inevitably exac-erbates the inhomogeneity ... Multidimensional integration and multifunctional com-ponent assembly have been greatly explored in recent years to extend Moore’s Law of modern microelectronics.However,this inevitably exac-erbates the inhomogeneity of temperature distribution in microsystems,making precise temperature control for electronic components extremely challenging.Herein,we report an on-chip micro temperature controller including a pair of thermoelectric legs with a total area of 50×50μm^(2),which are fabricated from dense and flat freestanding Bi2Te3-based ther-moelectric nano films deposited on a newly developed nano graphene oxide membrane substrate.Its tunable equivalent thermal resistance is controlled by electrical currents to achieve energy-efficient temperature control for low-power electronics.A large cooling temperature difference of 44.5 K at 380 K is achieved with a power consumption of only 445μW,resulting in an ultrahigh temperature control capability over 100 K mW^(-1).Moreover,an ultra-fast cooling rate exceeding 2000 K s^(-1) and excellent reliability of up to 1 million cycles are observed.Our proposed on-chip temperature controller is expected to enable further miniaturization and multifunctional integration on a single chip for microelectronics. 展开更多
关键词 temperature control Low-power electronics On-chip micro temperature controller Freestanding thermoelectric nano films temperature-sensitive components
下载PDF
Temperature-Based Fan Speed Optimization Strategy
2
作者 Chucheng Wang Chongyi Luo +3 位作者 Junnian Wei Haiyang Peng Xiaorong Zhong Cai Ye 《Journal of Electronic Research and Application》 2024年第3期135-141,共7页
As energy efficiency and indoor comfort increasingly become key standards in modern residential and office environments,research on intelligent fan speed control systems has become particularly important.This study ai... As energy efficiency and indoor comfort increasingly become key standards in modern residential and office environments,research on intelligent fan speed control systems has become particularly important.This study aims to develop a temperature-feedback-based fan speed optimization strategy to achieve higher energy efficiency and user comfort.Firstly,by analyzing existing fan speed control technologies,their main limitations are identified,such as the inability to achieve smooth speed transitions.To address this issue,a BP-PID speed control algorithm is designed,which dynamically adjusts fan speed based on indoor temperature changes.Experimental validation demonstrates that the designed system can achieve smooth speed transitions compared to traditional fan systems while maintaining stable indoor temperatures.Furthermore,the real-time responsiveness of the system is crucial for enhancing user comfort.Our research not only demonstrates the feasibility of temperature-based fan speed optimization strategies in both theory and practice but also provides valuable insights for energy management in future smart home environments.Ultimately,this research outcome will facilitate the development of smart home systems and have a positive impact on environmental sustainability. 展开更多
关键词 Smart temperature control Fan speed optimization temperature feedback control Dynamic speed adjustment Smart home systems Energy-saving technology
下载PDF
Reinforced temperature control of a reactive double dividing-wall distillation column
3
作者 Wei Qin Lijing Zang +5 位作者 Kejin Huang Haisheng Chen Yang Yuan Xing Qian Liang Zhang Shaofeng Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第2期288-295,共8页
The mass and thermal coupling makes the control of the reactive double dividing-wall distillation column(R-DDWDC) an especially challenging issue with a highly interactive nature. With reference to the separation of a... The mass and thermal coupling makes the control of the reactive double dividing-wall distillation column(R-DDWDC) an especially challenging issue with a highly interactive nature. With reference to the separation of an ideal endothermic quaternary reversible reaction with the most unfavorable ranking of relative volatilities(A + B ■ C + D with α_(A)>α_(C)>α_(D)>α_(B)), the operation rationality of the R-DDWDC is studied in this contribution. The four-point single temperature control system leads to great steady-state discrepancies in the compositions of products C and D and the reason stems essentially from the failure in keeping strictly the stoichiometric ratio between reactants A and B. A temperature plus temperature cascade control scheme is then employed to reinforce the stoichiometric ratio control and helps to secure a substantial abatement in the steady-state discrepancies. A temperature difference plus temperature cascade control scheme is finally synthesized and leads even to better performance than the most effective double temperature difference control scheme. These outcomes reveal not only the operation feasibility of the R-DDWDC but also the general significance of the proposed temperature difference plus temperature cascade control scheme to the inferential control of any other complicated distillation columns. 展开更多
关键词 Reactive double dividing-wall distillation column temperature control temperature plus temperature cascade control temperature difference plus temperature cascade control Process operation
下载PDF
Experimental study on temperature stress calculation and temperature control optimization of concrete based on early age parameters
4
作者 HU Yintao ZHOU Qiujing +3 位作者 YANG Ning QIAO Yu JIA Fan Xin Jianda 《中国水利水电科学研究院学报(中英文)》 北大核心 2023年第6期586-597,共12页
Temperature control curve is the key to achieving temperature control and crack prevention of high concrete dam during construction,and its rationality depends on the accurate measurement of temperature stress.With th... Temperature control curve is the key to achieving temperature control and crack prevention of high concrete dam during construction,and its rationality depends on the accurate measurement of temperature stress.With the simulation testing machine for the temperature stress,in the present study,we carried out the deformation process tests of concrete under three temperature curves:convex,straight and concave.Besides,we not only measured the early-age elastic modulus,creep parameters and stress process,but also proposed the preferred type.The results show that at early age,higher temperature always leads to greater elastic modulus and smaller creep.However,the traditional indoor experiments have underestimated the elastic modulus and creep development at early age,which makes the calculated value of temperature stress too small,thus increasing the cracking risk.In this study,the stress values of the three curves calculated based on the strain and early-age parameters are in good agreement with the temperature stress measured by the temperature stress testing machine,which verifies the method accuracy.When the temperature changes along the concave curve,the law of stress development is in consistent with that of strength.Under this condition,the stress fluctuation is small and the crack prevention safety of the concave type is higher,so the concave type is better.The test results provide a reliable basis and support for temperature control curve design and optimization of concrete dams. 展开更多
关键词 concrete dam temperature control curve early-age parameters temperature stress testing machine elastic modulus
下载PDF
Optimization of the Plugging Agent Dosage for High Temperature Salt Profile Control in Heavy Oil Reservoirs
5
作者 Jiayu Ruan Mingjing Lu +5 位作者 Wei Zhang Yuxi Zhang Yuhui Zhou Jie Gong Fan Wang Yuanxiao Guan 《Fluid Dynamics & Materials Processing》 EI 2023年第2期421-436,共16页
After steam discharge in heavy oil reservoirs,the distribution of temperature,pressure,and permeability in different wells becomes irregular.Flow channels can easily be produced,which affect the sweep efficiency of th... After steam discharge in heavy oil reservoirs,the distribution of temperature,pressure,and permeability in different wells becomes irregular.Flow channels can easily be produced,which affect the sweep efficiency of the oil displacement.Previous studies have shown that the salting-out plugging method can effectively block these channels in high-temperature reservoirs,improve the suction profile,and increase oil production.In the present study,the optimal dosage of the plugging agent is determined taking into account connection transmissibility and inter-well volumes.Together with the connectivity model,a water flooding simulation model is introduced.Moreover,a non-gradient stochastic disturbance algorithm is used to obtain the optimal plugging agent dosage,which provides the basis for the high-temperature salting-out plugging agent adjustment in the field. 展开更多
关键词 Heavy oil salting out profile control high temperature plugging agent dosage optimization numerical simulation connectivity model
下载PDF
Single-Stage Wide-Range CMOS VGA with Temperature Compensation and Linear-in-dB Gain Control 被引量:1
6
作者 恽廷华 尹莉 +1 位作者 吴建辉 时龙兴 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2007年第4期518-525,共8页
A novel wide-range CMOS variable gain amplifier (VGA) topology is presented. The proposed VGA is composed of a variable transconductor and a novel variable output resistor and can offer a high gain variation range o... A novel wide-range CMOS variable gain amplifier (VGA) topology is presented. The proposed VGA is composed of a variable transconductor and a novel variable output resistor and can offer a high gain variation range of 80dB while using a single variable-gain stage. Temperature-compensation and decibel-linear gain characteristic are achieved by using a control circuit that provides a gain error lower than ±1.5dB over the full temperature and gain ranges. Realized in 0.25μm CMOS technology, a prototype of the proposed VGA provides a total gain range of 64.5dB with 55.6dB-linear range,a P-1dB varying from - 17.5 to 11.5dBm,and a 3dB-bandwith varying from 65 to 860MHz while dissipating 16.5mW from a 2.5V supply voltage. 展开更多
关键词 linear-in-dB temperature compensation variable-gain amplifier automatic gain control
下载PDF
Response of Over-summer Hydroponic Lettuce to Nutrient Solution Temperature Control 被引量:2
7
作者 李锋 陈学东 《Agricultural Science & Technology》 CAS 2017年第6期1072-1075,共4页
Temperature, as an important feature of hydroponic nutrient solution, is closely related to dissolved oxygen content of nutrient solution and growth status of plant roots. How to precisely adjust the temperature of nu... Temperature, as an important feature of hydroponic nutrient solution, is closely related to dissolved oxygen content of nutrient solution and growth status of plant roots. How to precisely adjust the temperature of nutrient solution is the key to obtain high quality and high yield of hydroponic vegetables over summer. With Lactuca sativa vat. crispa 'Luosheng No.3' as the test material, the effect of chiller cooling technology on the temperature of nutrient solution, as well as on the yield and quality of Luosheng No.3, in over-summer hydroponic cultivation was studied. The results showed that the chiller cooling technology controlled the nutrient solution temperature in a reasonable range ((20 ± 1)℃) and promoted the growth and dry matter accumulation of Luosheng No.3, instead of affecting the quality. In short, the chiller cooling technology is applicable to the temperature regulation of nutrient solu- tion in hydroponics over summer. 展开更多
关键词 HYDROPONICS Nutrient solution temperature control LETTUCE Over sum-mer
下载PDF
Studies on the Economical and Practical Temperature Control Facility of Deep-Litter Systems for Swine Production
8
作者 林家彬 秦竹 +5 位作者 周忠凯 顾洪如 杨杰 汤赤 陈俊 余刚 《Agricultural Science & Technology》 CAS 2013年第7期1053-1056,共4页
Deep-Litter System is a high yield approach to raise swine with pollution free in a lower cost. In the research, based on the heat stress in summer caused by fermentation, three temperature-control systems were design... Deep-Litter System is a high yield approach to raise swine with pollution free in a lower cost. In the research, based on the heat stress in summer caused by fermentation, three temperature-control systems were designed, including natural ventilation through transoms, forced ventilation via fans, and cooling by hyperbaric spray system. Specifically, the latter intermittent auto-pressurized spray system developed in our lab, which could spray successively via pressure from storage tubes without wetting the fermentation bed, is suitable for the promotion with the deep-litter technology in rural regions , since the power consumption is only 1 kwh per day. 展开更多
关键词 Deep litter system temperature control facilities Intermittent auto-pressurized spray system Economical and practical
下载PDF
Preference-based multiobjective artificial bee colony algorithm for optimization of superheated steam temperature control
9
作者 周霞 沈炯 李益国 《Journal of Southeast University(English Edition)》 EI CAS 2014年第4期449-455,共7页
In order to incorporate the decision maker's preference into multiobjective optimization a preference-based multiobjective artificial bee colony algorithm PMABCA is proposed.In the proposed algorithm a novel referenc... In order to incorporate the decision maker's preference into multiobjective optimization a preference-based multiobjective artificial bee colony algorithm PMABCA is proposed.In the proposed algorithm a novel reference point based preference expression method is addressed.The fitness assignment function is defined based on the nondominated rank and the newly defined preference distance.An archive set is introduced for saving the nondominated solutions and an improved crowding-distance operator is addressed to remove the extra solutions in the archive.The experimental results of two benchmark test functions show that a preferred set of solutions and some other non-preference solutions are achieved simultaneously.The simulation results of the proportional-integral-derivative PID parameter optimization for superheated steam temperature verify that the PMABCA is efficient in aiding to making a reasonable decision. 展开更多
关键词 PREFERENCE MULTIOBJECTIVE artificial bee colony superheated steam temperature control OPTIMIZATION
下载PDF
Temperature distribution and dynamic control of secondary cooling in slab continuous casting 被引量:9
10
作者 Liang-hang Guo Yong Tian +1 位作者 Man Yao Hou-fa Shen 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2009年第6期626-631,共6页
To predict and optimize the temperature distribution of slab continuous casting in steady operational state, a three-dimensional model (named "offline model") based on the heat transfer and solidification theories... To predict and optimize the temperature distribution of slab continuous casting in steady operational state, a three-dimensional model (named "offline model") based on the heat transfer and solidification theories was developed. Both heat transfer and flux distribution characteristics of the nozzle sprays on the slab were considered, and the complicated boundary conditions, such as spray cooling, natural convection, thermal radiation as well as contact cooling of individual rolls were involved in the model. By using the calibrated caster dependent model factors, the calculated temperature and shell thickness accorded well with the measured. Furthermore, a dynamic secondary water cooling control system was also developed on the basis of a two-dimensional transient heat transfer model (named "online model") and incremental PID control algorithm to reduce slab surface temperature fluctuation in unsteady state. Compared with the traditional spray table control method, the present online model and dynamic PID control demonstrate a higher capability and flexibility to adjust cooling water flowrate and reduce slab surface temperature fluctuation when the casting speed is changed. 展开更多
关键词 mathematical model slab temperature dynamic control continuous casting
下载PDF
Fuzzy self-tuning PID control of the operation temperatures in a two-staged membrane separation process 被引量:8
11
作者 Lei Wang Wencai Du +1 位作者 Hai Wang Hong Wu 《Journal of Natural Gas Chemistry》 EI CAS CSCD 2008年第4期409-414,共6页
A two-staged membrane separation process for hydrogen recovery from refinery gases is introduced. The principle of the gas membrane separation process and the influence of the operation temperatures are analyzed. As t... A two-staged membrane separation process for hydrogen recovery from refinery gases is introduced. The principle of the gas membrane separation process and the influence of the operation temperatures are analyzed. As the conventional PID controller is difficult to make the operation temperatures steady, a fuzzy self-tuning PID control algorithm is proposed. The application shows that the algorithm is effective, the operation temperatures of both stages can be controlled steadily, and the operation flexibility and adaptability of the hydrogen recovery unit are enhanced with safety. This study lays a foundation to optimize the control of the membrane separation process and thus ensure the membrane performance. 展开更多
关键词 membrane separation hydrogen recovery operation temperature fuzzy self-tuning PID control
下载PDF
Intelligent Temperature Control System Design Based on Single-Chip Microcomputer 被引量:7
12
作者 Jun Li Xian-Lin Meng Wen-Long Song 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2014年第3期91-94,共4页
A design method of an intelligent temperature control system based on single-chip microcomputer is presented in this paper. The intelligent temperature control system is divided into four parts: monitor,heater,control... A design method of an intelligent temperature control system based on single-chip microcomputer is presented in this paper. The intelligent temperature control system is divided into four parts: monitor,heater,controlled process and feedback loop. Among them,the temperature detection circuit is designed with the conductivity of water by sensor detection. The optical coupler MOC3041 is used to implement the power control circuit,whose control object is 1 kW electric heater with the 220 V alternating current power; keyboard and display circuit SMC1602A include four buttons and LCD display to achieve human-computer interaction; Based on single-chip system STC89C52,the sensor signal and keyboard set target temperature are compared to the power automatically in order to finish the water temperature control. Through the static and dynamic data testing,the results show that the proposed method provides an effective way to realize the real-time acquisition and control of temperature. 展开更多
关键词 MICROcontrolLER temperature sensors power control SCR
下载PDF
Multivariable temperature measurement and control system of large-scaled vertical quench furnace based on temperature field 被引量:7
13
作者 XuanZHOU ShouyiYU +1 位作者 JiangYU LiequanLIANG 《控制理论与应用(英文版)》 EI 2004年第4期401-405,共5页
A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospac... A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospace industry. For the effective operation of the furnace, it is essential to analyze the radial temperature distribution of the furnace. A set of thermodynamic balance equations modeling is established firsdy. By utilizing the numerical analysis result to modify the temperature measurements, the control accuracy and precision of the temperature are truly guaranteed. Furthermore, the multivariable decoupling self-learning PID control algorithm based on the characteristics of strong coupling between the multi-zones in the large-scaled furnace is implemented to ensure the true homogeneity of the axial temperature distribution. Finally, the redundant structure composed of industrial control computers and touch panels leads to great improvement of system reliability. 展开更多
关键词 Axial temperature distribution homogeneity Radial temperature distribution Decoupling self-learning PID control Redundant structure
下载PDF
Temperature inferential control of a reactive distillation column with double reactive sections 被引量:4
14
作者 Lijing Zang Kejin Huang +5 位作者 Ting Guo Yang Yuan Haisheng Chen Liang Zhang Xing Qian Shaofeng Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2019年第4期896-904,共9页
Temperature inferential control (TIC) is studied for a reactive distillation column with double reactive sections (RDC-DRSs) processing a hypothetical two-stage consecutive reversible reaction (A + B■C + D, C + B■E ... Temperature inferential control (TIC) is studied for a reactive distillation column with double reactive sections (RDC-DRSs) processing a hypothetical two-stage consecutive reversible reaction (A + B■C + D, C + B■E + D with αD > αB > αC > αA > αE). Because of the complicated dynamic behaviors, the controlled stages by sensitivity analysis lead to great steady-state deviations (SSDs) in top and bottom product purities. Since TIC involves considerably reduced settling times in comparison with direct composition control, small SSDs in product qualities correspond generally to small transient deviations (TDs) in product qualities. An objective function that measures SSDs in product qualities is formulated to represent the performance of a TIC system and an iterative procedure is devised to search for the best control configuration. The application of the procedure to the RDC-DRS gives considerably suppressed TDs and SSDs in top and bottom product qualities as compared with the one by sensitivity analysis. The method is simpler in principle and less computationally intensive than the current practice. These striking outcomes show the effectiveness of the proposed principle for the development of TIC systems for complicated reactive distillation columns. 展开更多
关键词 REACTIVE DISTILLATION COLUMN temperature inferential control Sensitivity analysis Transient deviation STEADY-STATE deviation
下载PDF
Neuro-fuzzy generalized predictive control of boiler steam temperature 被引量:5
15
作者 Xiangjie LIU Jizhen LIU Ping GUAN 《控制理论与应用(英文版)》 EI 2007年第1期83-88,共6页
Power plants are nonlinear and uncertain complex systems. Reliable control of superheated steam temperature is necessary to ensure high efficiency and high load-following capability in the operation of modem power pla... Power plants are nonlinear and uncertain complex systems. Reliable control of superheated steam temperature is necessary to ensure high efficiency and high load-following capability in the operation of modem power plant. A nonlinear generalized predictive controller based on neuro-fuzzy network (NFGPC) is proposed in this paper. The proposed nonlinear controller is applied to control the superheated steam temperature of a 200MW power plant. From the experiments on the plant and the simulation of the plant, much better performance than the traditional controller is obtained, 展开更多
关键词 Neuro-fuzzy networks Generalized predictive control Superheated steam temperature
下载PDF
Optimization of Holding Temperature and Holding Thickness for Controlled Rolling on Plate Mill 被引量:3
16
作者 HU Xian-lei ZHAO Zhong WANG Jun WANG Zhao-dong LIU Xiang-hua WANG Guo-dong 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2006年第3期21-25,共5页
Holding temperature and holding thickness are main parameters for two-phase controlled rolling on plate mill. The optimization of holding temperature and holding thickness for pass schedule calculation of two-phase co... Holding temperature and holding thickness are main parameters for two-phase controlled rolling on plate mill. The optimization of holding temperature and holding thickness for pass schedule calculation of two-phase controlled rolling on plate mill was presented and its feature is as follows: (1) Determination of holding thickness can be automatically obtained based on the influence of mill safety limits, tracking zone length and holding time on holding thickness; (2) Determination of holding temperature can be automatically obtained and the holding time can be reduced as much as possible; (3) Algorithm can modify the holding temperature and thickness depending on slab size and product size. 展开更多
关键词 PLATE two-phase controlled rolling pass schedule holding temperature holding thickness
下载PDF
Temperature control and cracking prevention in coastal thin-wall concrete structures 被引量:3
17
作者 Li-xia GUO Xiao-hong BAI +1 位作者 Ling ZHONG Sheng QIANG 《Water Science and Engineering》 EI CAS 2011年第4期455-462,共8页
A three-dimensional finite element program for thermal analysis of hydration heat in concrete structures with a plastic pipe cooling system is introduced in this paper. The program was applied to simulation of the tem... A three-dimensional finite element program for thermal analysis of hydration heat in concrete structures with a plastic pipe cooling system is introduced in this paper. The program was applied to simulation of the temperature and stress field of the Cao'e Sluice during the construction period. From the calculated results, we can find that the temperaiure and stress of concrete cooled with plastic pipes are much lower than those of concrete without pipes. Moreover, plastic pipes could not be corroded by seawater. That is to say, a good effect of temperature control and cracking prevention can be achieved, which provides a useful reference for other similar nearshore concrete projects. 展开更多
关键词 coastal structures plastic pipe cooling temperature control cracking prevention steel corrosion
下载PDF
Preparation of graphene oxides with different sheet sizes by temperature control 被引量:2
18
作者 钱哲 陈亮 +5 位作者 李德远 彭兵权 石国升 徐刚 方海平 吴明红 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期316-320,共5页
The sheet size of a graphene oxide (GO) can greatly influence its electrical, optical, mechanical, electrochemical and catalytic property. It is a key challenge to how to control the sheet size during its preparatio... The sheet size of a graphene oxide (GO) can greatly influence its electrical, optical, mechanical, electrochemical and catalytic property. It is a key challenge to how to control the sheet size during its preparation in different application fields. According to our previous theoretical calculations of the effect of temperature on the oxidation process of graphene, we use Hummers method to prepare GOs with different sheet sizes by simply controlling the temperature condition in the process of the oxidation reaction of potassium permanganate (KMnO4) with graphene and the dilution process with deionized water. The results detected by transmission electron microscopy (TEM) and atomic force microscopy (AFM) show that the average sizes of GO sheets prepared at different temperatures are about 1 μm and 7 μm respectively. The ultraviolet-visible spectroscopy (UV-vis) shows that lower temperature can lead to smaller oxidation degrees of GO and less oxygen functional groups on the surface. In addition, we prepare GO membranes to test their mechanical strengths by ultrasonic waves, and we find that the strengths of the GO membranes prepared under low temperatures are considerably higher than those prepared under high temperatures, showing the high mechanical strengths of larger GO sheets. Our experimental results testify our previous theoretical calculations. Compared with the traditional centrifugal separation and chemical cutting method, the preparation process of GO by temperature control is simple and low-cost and also enables large-size synthesis. These findings develop a new method to control GO sheet sizes for large-scale potential applications. 展开更多
关键词 graphene oxide sheet size temperature control degree of oxidation
下载PDF
A Two-stage pH and Temperature Control with Substrate Feeding Strategy for Production of Gamma-aminobutyric Acid by Lactobacillus brevis CGMCC 1306 被引量:7
19
作者 彭春龙 黄俊 +3 位作者 胡升 赵伟睿 姚善泾 梅乐和 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2013年第10期1190-1194,共5页
Methods to optimize the production of gamma-aminobutyric acid (GABA) by Lactobacillus brevis CGMCC 1306 were investigated. Results indicated that cell growth was maximal at pH 5.0, while pH 4.5 was pref-erable to GA... Methods to optimize the production of gamma-aminobutyric acid (GABA) by Lactobacillus brevis CGMCC 1306 were investigated. Results indicated that cell growth was maximal at pH 5.0, while pH 4.5 was pref-erable to GABA formation. The optimal temperature for cell growth (35 °C) was lower than that for GABA forma-tion (40 °C). In a two-stage pH and temperature control fermentation, cultures were maintained at pH 5.0 and 35 °C for 32 h, then adjusted to pH 4.5 and 40 °C, GABA production increased remarkably and reached 474.79 mmol·L-1 at 72 h, while it was 398.63 mmol·L-1 with one stage pH and temperature control process, in which cultivation con-ditions were constantly controlled at pH 5.0 and 35 °C. In order to avoid the inhibition of cell growth at higher L-monosodium glutamate (L-MSG) concentrations, the two-stage control fermentation with substrate feeding strat-egy was applied to GABA production, with 106.87 mmol (20 g) L-MSG supplemented into the shaking-flask at 32 h and 56 h post-inoculation separately. The GABA concentration reached 526.33 mmol·L-1 at 72 h with the fer-mentation volume increased by 38%. These results will provide primary data to realize large-scale production of GABA by L. brevis CGMCC 1306. 展开更多
关键词 gamma-aminobutyric acid Lactobacillus brevis CGMCC 1306 two-stage pH and temperature control substrate feeding
下载PDF
Real-Time Temperature Control for High Arch Dam Based on Decision Support System 被引量:4
20
作者 井向阳 刘杏红 +1 位作者 周伟 常晓林 《Transactions of Tianjin University》 EI CAS 2014年第2期118-125,共8页
It is important and difficult to control the temperature of mass concrete structure during high arch dam construction.A new method with decision support system is presented for temperature control and crack prevention... It is important and difficult to control the temperature of mass concrete structure during high arch dam construction.A new method with decision support system is presented for temperature control and crack prevention.It is a database system with functions of data storage,information inquiry,data analysis,early warning and resource sharing.Monitoring information during construction can be digitized via this system,and the intelligent analysis and dynamic control of concrete temperature can be conducted.This method has been applied in the construction of the Dagangshan Arch Dam in China and has proven to be very convenient.Based on the decision support of this system and the dynamic adjustment of construction measures,the concrete temperature of this project is well-controlled. 展开更多
关键词 concrete arch dam temperature control decision support system pipe cooling MONITORING
下载PDF
上一页 1 2 250 下一页 到第