期刊文献+
共找到102篇文章
< 1 2 6 >
每页显示 20 50 100
Experimental investigation for temperature and emissivity by flame emission spectrum in a cavity of rocket based combined cycle combustor chamber
1
作者 Weiguang Cai Shu Zheng +4 位作者 Yan Wang Bing Liu Shaohua Zhu Li Zhao Qiang Lu 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第9期114-122,共9页
Flame temperature and spectral emissivity were the important parameters characterizing the sufficient degree of fuel combustion and the particle radiative characteristics in the Rocket Based Combined Cycle(RBCC)combus... Flame temperature and spectral emissivity were the important parameters characterizing the sufficient degree of fuel combustion and the particle radiative characteristics in the Rocket Based Combined Cycle(RBCC)combustor.To investigate the combustion characteristics of the complex supersonic flame in the RBCC combustor,a new radiation thermometry combined with Levenberg-Marquardt(LM)algorithm and the least squares method was proposed to measure the temperature,emissivity and spectral radiative properties based on the flame emission spectrum.In-situ measurements of the flame temperature,emissivity and spectral radiative properties were carried out in the RBCC direct-connected test bench with laser-induced plasma combustion enhancement(LIPCE)and without LIPCE.The flame average temperatures at fuel global equivalence ratio(a)of 1.0b and 0.6 with LIPCE were 4.51%and 2.08%higher than those without LIPCE.The flame combustion oscillation of kerosene tended to be stable in the recirculation zone of cavity with the thermal and chemical effects of laser induced plasma.The differences of flame temperature at a=1.0b and 0.6 were 503 K and 523 K with LIPCE,which were 20.07%and42.64%lower than those without LIPCE.The flame emissivity with methane assisted ignition was 80.46%lower than that without methane assisted ignition,due to the carbon-hydrogen ratio of kerosene was higher than that of methane.The spectral emissivities at 600 nm with LIPCE were 1.25%,22.2%,and 4.22%lower than those without LIPCE at a=1.0a(with methane assisted ignition),1.0b(without methane assisted ignition)and 0.6.The effect of concentration in the emissivity was removed by normalization to analyze the flame radiative properties in the RBCC combustor chamber.The maximum differences of flame normalized emissivity were 50.91%without LIPCE and 27.53%with LIPCE.The flame radiative properties were stabilized under the thermal and chemical effects of laser induced plasma at a=0.6. 展开更多
关键词 Rocket-based combined-cycle Supersonic combustion Flame temperature measurement EMISSIVITY Laser induced plasma combustion enhancement
下载PDF
Deep learning-assisted common temperature measurement based on visible light imaging
2
作者 朱佳仪 何志民 +8 位作者 黄成 曾峻 林惠川 陈福昌 余超群 李燕 张永涛 陈焕庭 蒲继雄 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期230-236,共7页
Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This pap... Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This paper proposes an alternative approach of extracting temperature information in real time from the visible light images of the monitoring target using a convolutional neural network(CNN).A mean-square error of<1.119℃was reached in the temperature measurements of low to medium range using the CNN and the visible light images.Imaging angle and imaging distance do not affect the temperature detection using visible optical images by the CNN.Moreover,the CNN has a certain illuminance generalization ability capable of detection temperature information from the images which were collected under different illuminance and were not used for training.Compared to the conventional machine learning algorithms mentioned in the recent literatures,this real-time,contact-free temperature measurement approach that does not require any further image processing operations facilitates temperature monitoring applications in the industrial and civil fields. 展开更多
关键词 convolutional neural network visible light image temperature measurement low-to-medium-range temperatures
下载PDF
Multipoint Infrared Telemetry System for Measuring the Piston Temperature in Internal Combustion Engines 被引量:5
3
作者 刘金祥 魏春源 +1 位作者 张卫正 郭良平 《Journal of Beijing Institute of Technology》 EI CAS 2002年第4期346-349,共4页
A high precision, high antijamming multipoint infrared telemetry system was developed to measure the piston temperature in internal combustion engine. The temperature at the measuring point is converted into correspon... A high precision, high antijamming multipoint infrared telemetry system was developed to measure the piston temperature in internal combustion engine. The temperature at the measuring point is converted into corresponding voltage signal by the thermo-couple first. Then after the V/F stage, the voltage signal is converted into the frequency signal to drive the infrared light-emitting diode to transmit infrared pulses. At the receiver end, a photosensitive audion receives the infrared pulses. After conversion, the voltage recorded by the receiver stands for the magnitude of temperature at the measuring point. Test results of the system indicate that the system is practical and the system can perform multipoint looping temperature measurements for the piston. 展开更多
关键词 PISTON temperature measurement infrared telemetry
下载PDF
Investigation on the plastic work-heat conversion coefficient of 7075-T651 aluminum alloy during an impact process based on infrared temperature measurement technology 被引量:3
4
作者 Tong Zhang Ze-Rong Guo +1 位作者 Fu-Ping Yuan Hu-Sheng Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2018年第2期327-333,共7页
The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic com... The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat. 展开更多
关键词 Plastic work-heat conversion coefficient Infrared temperature measurement Dynamic compression 7075-T651 Aluminum alloy
下载PDF
The dating and temperature measurement technologies for carbonate minerals and their application in hydrocarbon accumulation research in the paleouplift in central Sichuan Basin, SW China 被引量:5
5
作者 SHEN Anjiang ZHAO Wenzhi +3 位作者 HU Anping WANG Hui LIANG Feng WANG Yongsheng 《Petroleum Exploration and Development》 CSCD 2021年第3期555-568,共14页
A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearin... A new method for reconstructing the geological history of hydrocarbon accumulation is developed, which are constrained by U-Pb isotope age and clumped isotope((35)47) temperature of host minerals of hydrocarbon-bearing inclusions. For constraining the time and depth of hydrocarbon accumulation by the laser in-situ U-Pb isotope age and clumped isotope temperature, there are two key steps:(1) Investigating feature, abundance and distribution patterns of liquid and gaseous hydrocarbon inclusions with optical microscopes.(2) Dating laser in-situ U-Pb isotope age and measuring clumped isotope temperature of the host minerals of hydrocarbon inclusions. These technologies have been applied for studying the stages of hydrocarbon accumulation in the Sinian Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin. By dating the U-Pb isotope age and measuring the temperature of clumped isotope((35)47) of the host minerals of hydrocarbon inclusions in dolomite, three stages of hydrocarbon accumulation were identified:(1) Late Silurian: the first stage of oil accumulation at(416±23) Ma.(2) Late Permian to Early Triassic: the second stage of oil accumulation between(248±27) Ma and(246.3±1.5) Ma.(3) Yanshan to Himalayan period: gas accumulation between(115±69) Ma and(41±10) Ma. The reconstructed hydrocarbon accumulation history of the Dengying gas reservoir in the paleo-uplift of the central Sichuan Basin is highly consistent with the tectonic-burial history, basin thermal history and hydrocarbon generation history, indicating that the new method is a reliable way for reconstructing the hydrocarbon accumulation history. 展开更多
关键词 laser in-situ U-Pb isotope dating clumped isotope thermometry hydrocarbon inclusions carbonate mineral dating carbonate mineral temperature measurement host mineral hydrocarbon accumulation paleo-uplift in central Sichuan Basin Sinian Dengying Formation
下载PDF
Infrared radiation method for measuring ice segregation temperature of artificially frozen soils 被引量:3
6
作者 Zhou Guoqing Zhang Qi +1 位作者 Xu Zhiwei Zhou Yang 《International Journal of Mining Science and Technology》 2012年第1期35-40,共6页
In order to study the evolution of the freezing fringe and final lenses of frost susceptible soils and advance the understanding of frost heave and mechanism of frost heave control, we used an open one-dimensional fro... In order to study the evolution of the freezing fringe and final lenses of frost susceptible soils and advance the understanding of frost heave and mechanism of frost heave control, we used an open one-dimensional frost heave test system of infrared radiation technology, instead of a traditional thermistor method. Temperatures of the freezing fringe and segregated ice were measured in a non-contact mode. The results show that accurate and precise temperatures of ice segregation can be obtained by infrared thermal imaging systems. A self-developed inversion program inverted the temperature field of frozen soils. Based on our analysis of temperature variation in segregated ice and our study of the relationship between temperature and rate of ice segregation in cooling and warming processes during intermittent freezing, the mechanism of decreasing frost heave of frozen soils by controlling the growth of final lenses with an intermittent freezing mode, can be explained properly. 展开更多
关键词 One-dimensional freezing Final lens Ice segregation temperature measurement Infrared radiation method
下载PDF
Rock temperature variability in high-altitude rockfall-prone areas 被引量:1
7
作者 Guido NIGRELLI Marta CHIARLE +2 位作者 Andrea MERLONE Graziano COPPA Chiara MUSACCHIO 《Journal of Mountain Science》 SCIE CSCD 2022年第3期798-811,共14页
In a context of cryosphere degradation caused by climate warming,rock temperature is one of the main driving factors of rockfalls that occur on high-elevation mountain slopes.In order to improve the knowledge of this ... In a context of cryosphere degradation caused by climate warming,rock temperature is one of the main driving factors of rockfalls that occur on high-elevation mountain slopes.In order to improve the knowledge of this critical relationship,it is necessary to increase measurement capability of rock temperature and its variability in different lithological and slope/aspect conditions,and also to increase local scale studies,increasing the quality and the comparability of the data.This paper shows an example of metrological characterization of sensors used for rock temperature measurement in mountain regions,by means of the measurement uncertainty.Under such approach,data and results from temperature measurements carried out in the Bessanese high-elevation experimental site(Western European Alps)are illustrated.The procedures for the calibration and field characterization of sensors allow to measure temperature in different locations,depths and lithotypes,within 0.10°C of overall uncertainty.This work has highlighted that metrological traceability is fundamental to asses data quality and establish comparability among different measurements;that there are strong differences between air temperature and near-surface rock temperature;and that there are significant differences of rock temperature acquired in different aspect conditions.Finally,solar radiation,slope/aspect conditions and lithotype,seem to be the main driving factors of rock temperature. 展开更多
关键词 Rock temperature ROCKFALLS European Alps Climate warming temperature measurement
下载PDF
Measurement of a Three-dimensional Gas Temperature Field with Holographic Interferometry 被引量:2
8
作者 CHEN Shaohua(Yibin Teacher’s College, Yibin 644007, CHN)ZHAO Xuxin HUANG Suyi SHI Dufang(Huazhong University of Science and Technology, Wuhan 430074, CHN) 《Semiconductor Photonics and Technology》 CAS 1996年第1期72-78,共7页
It is well known that optical tomography can accurately and quantitatively reconstruct the refractive index field of a transparent medium and display the three dimensional image of other physical quantities relevant t... It is well known that optical tomography can accurately and quantitatively reconstruct the refractive index field of a transparent medium and display the three dimensional image of other physical quantities relevant to temperature or density. In this paper, a new multidirectional holographic interferometric system is built, and two kinds of image reconstruction algorithms are introduced and an automatic image processing system of interferogram is designed. A three dimentsional asymmetric gas flow field above a combustor is expertmentally investigated with holographic interferometry. The reconstructed temperatures are similar to those measured with a thermocouple. 展开更多
关键词 Optical Tomography Orthographic Holography Reconstruction Algorithm Image Processing temperature Measurement
下载PDF
Research on the Explosion Temperature Response of Fuel Air Explosive Measured by Colorimetric Pyrometer 被引量:1
9
作者 刘庆明 白春华 《Defence Technology(防务技术)》 SCIE EI CAS 2010年第1期59-64,共6页
An infrared colorimetric radiation thermometrical system was established based on the theory of optical radiation. The dynamic temperature history of fuel air explosive (FAE) was measured to obtain the temperature res... An infrared colorimetric radiation thermometrical system was established based on the theory of optical radiation. The dynamic temperature history of fuel air explosive (FAE) was measured to obtain the temperature responses of primary initiation FAE and secondary initiation FAE in real time. And the characteristics of their temperature history curves were compared and analyzed. The results show that the primary initiation FAE has higher explosion temperature and longer duration compared to the secondary initiation FAE. 展开更多
关键词 mechanics of explosion explosion temperature fuel air explosive radiation pyrometry colorimetric pyrometer infrared temperature measurement
下载PDF
Development of 2D Temperature and Concentration Measurement Method Using Tunable Diode Laser Absorption Spectroscopy 被引量:7
10
作者 Yoshihiro Deguchi Daisuke Yasui Akira Adachi 《Journal of Mechanics Engineering and Automation》 2012年第9期543-549,共7页
Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is int... Exhaust gas temperature is an important factor in NOx, THC and PM emissions of engines. Especially 2D temperature and concentration distribution plays an important role for the engine efficiency. A thermocouple is intrinsically a point temperature measurement method and noncontact 2D temperature distribution cannot be attained by thermocouples. Recently, as a measurement technique with high sensitivity and high response, laser diagnostics has been developed and applied to the actual engine combustions. With these engineering developments, transient phenomena such as start-ups and load changes in engines have been gradually elucidated in various conditions. In this study, the theoretical and experimental research has been conducted in order to develop the noncontact and fast response 2D temperature and concentration distribution measurement method. The method is based on a Computed Tomography (CT) method using absorption spectra of water vapor at 1388 nm. It has been demonstrated that the method has been successfully applied to engine exhausts to measure 2D temperature distributions. 展开更多
关键词 2D temperature measurement tunable diode laser absorption spectroscopy CT (computed tomography) engine exhausts.
下载PDF
Numerical investigation on the flow characteristics of a reverse-polarity plasma torch by two-temperature thermal non-equilibrium modelling 被引量:1
11
作者 Zhengxin YIN Deping YU +3 位作者 Yana WEN Qingbo ZHANG Jier QIU Shengyuan YANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2021年第9期86-101,共16页
A two-temperature(2 T)thermal non-equilibrium model is developed to address the thermal nonequilibrium phenomenon that inevitably exists in the reverse-polarity plasma torch(RPT)and applied to numerically investigate ... A two-temperature(2 T)thermal non-equilibrium model is developed to address the thermal nonequilibrium phenomenon that inevitably exists in the reverse-polarity plasma torch(RPT)and applied to numerically investigate the plasma flow characteristics inside and outside the RPT.Then,a detailed comparison of the results of the 2 T model with those of the local thermal equilibrium(LTE)model is presented.Furthermore,the temperature of the plasma jet generated by a RPT and the RPT’s voltage are experimentally measured to compare and validate the result obtained by different models.The differences of the measured excitation temperature and the arc voltage between the 2 T model and experimental measurement are less than 13%and 8%,respectively,in all operating cases,validating the effectiveness of the 2 T model.The LTE model overestimates the velocity and temperature distribution of the RPT and its plasma jet,showing that thermal non-equilibrium phenomena cannot be neglected in the numerical modelling of the RPT.Unlike other common hot cathode plasma torches,the thermal non-equilibrium phenomenon is found even in the arc core of the RPT,due to the strong cooling effect caused by the big gas flow rate. 展开更多
关键词 optical emission spectroscopy reverse-polarity plasma torch temperature measurement two-temperature thermal non-equilibrium modelling
下载PDF
Research on the principle of space high-precision temperature control system of liquid crystals based Stokes polarimeter 被引量:1
12
作者 Xin-Wei Zhang Yang Zhang +2 位作者 Jia-Ben Lin Jun-Feng Hou Yuan-Yong Deng 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第1期97-104,共8页
The magnetic field is one of the most important parameters in solar physics,and a polarimeter is the key device to measure the solar magnetic field.Liquid crystals based Stokes polarimeter is a novel technology,and wi... The magnetic field is one of the most important parameters in solar physics,and a polarimeter is the key device to measure the solar magnetic field.Liquid crystals based Stokes polarimeter is a novel technology,and will be applied for magnetic field measurement in the first space-based solar observatory satellite developed by China,Advanced Space-based Solar Observatory.However,the liquid crystals based Stokes polarimeter in space is not a mature technology.Therefore,it is of great scientific significance to study the control method and characteristics of the device.The retardation produced by a liquid crystal variable retarder is sensitive to the temperature,and the retardation changes 0.09°per 0.10℃.The error in polarization measurement caused by this change is 0.016,which affects the accuracy of magnetic field measurement.In order to ensure the stability of its performance,this paper proposes a high-precision temperature control system for liquid crystals based Stokes polarimeter in space.In order to optimize the structure design and temperature control system,the temperature field of liquid crystals based Stokes polarimeter is analyzed by the finite element method,and the influence of light on the temperature field of the liquid crystal variable retarder is analyzed theoretically.By analyzing the principle of highprecision temperature measurement in space,a high-precision temperature measurement circuit based on integrated operational amplifier,programmable amplifier and 12 bit A/D is designed,and a high-precision space temperature control system is developed by applying the integral separation PI temperature control algorithm and PWM driving heating films.The experimental results show that the effect of temperature control is accurate and stable,whenever the liquid crystals based Stokes polarimeter is either in the air or vacuum.The temperature stability is within±0.0150℃,which demonstrates greatly improved stability for the liquid crystals based Stokes polarimeter. 展开更多
关键词 liquid crystals based Stokes polarimeter high-precision temperature measurement space high-precision temperature control temperature field analysis PID control
下载PDF
Spatial resolved temperature measurement based on absorption spectroscopy using a single tunable diode laser 被引量:3
13
作者 Xilong Yu Fei Li Lihong Chen Xinyu Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2010年第1期147-149,共3页
A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS... A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS. 展开更多
关键词 WMS-2fTDLAS - Profile fitting Spatial resolved - temperature measurement
下载PDF
Research on key techniques of expendable conductivity temperature depth measuring system 被引量:5
14
作者 CHEN Guangyuan DU Libin +3 位作者 HE Haijing LEI Zhuo ZHANG Qisheng WU Chengxuan 《Instrumentation》 2015年第2期18-27,共10页
This paper analysis the developing of expendable conductivity temperature depth measuring system(XCTD)and introduce its principle of measuring about temperature,salinity and depth of ocean.Some key techniques are put ... This paper analysis the developing of expendable conductivity temperature depth measuring system(XCTD)and introduce its principle of measuring about temperature,salinity and depth of ocean.Some key techniques are put forward.According to the real needs of XCTD,conductivity sensor with high sensitivity is designed by principle of electromagnetic induce,the ocean conductivity from induced electromotive force has been calculated.Adding temperature correction circuit would help to reduce error of conductivity measurement because of sharply changing temperature.Advanced temperature measuring circuit of high precision and the constant current source is used to weaken effect of self-heating of resistance and fluctuation of the source.On respect of remote data transmission,LVDS is a good choice for the purpose of guarantee the quality of data transmitted and the transmission distance is reaching to thousand meters in the seawater.Modular programming method is also brought into this research aimed at improve the stability,reliability and maintainability of the whole measuring system.In February,2015,the trials in South China Sea demonstrate that the developed XCTD realize effective measurement at a speed of 6 knots and detection depth at 800 m.The consistency coefficient of the acquired data is greater than 0.99 and the success rate of probe launching is above 90%. 展开更多
关键词 expendable device XCTD conductivity sensor high precision temperature measuring circuit remote data transmission
下载PDF
Comparison of TMI and AMSR-E sea surface temperatures with Argo near-surface temperatures over the global oceans 被引量:1
15
作者 CHEN Xingrong LIU Zenghong +1 位作者 SUN Chaohui WANG Haiyan 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2017年第3期52-59,共8页
Satellite-derived sea surface temperatures(SSTs) from the tropical rainfall measuring mission(TRMM)microwave imager(TMI) and the advanced microwave scanning radiometer for the earth observing system(AMSR-E) we... Satellite-derived sea surface temperatures(SSTs) from the tropical rainfall measuring mission(TRMM)microwave imager(TMI) and the advanced microwave scanning radiometer for the earth observing system(AMSR-E) were compared with non-pumped near-surface temperatures(NSTs) obtained from Argo profiling floats over the global oceans. Factors that might cause temperature differences were examined, including wind speed, columnar water vapor, liquid cloud water, and geographic location. The results show that both TMI and AMSR-E SSTs are highly correlated with the Argo NSTs; however, at low wind speeds, they are on average warmer than the Argo NSTs. The TMI performs slightly better than the AMSR-E at low wind speeds, whereas the TMI SST retrievals might be poorly calibrated at high wind speeds. The temperature differences indicate a warm bias of the TMI/AMSR-E when columnar water vapor is low, which can indicate that neither TMI nor AMSR-E SSTs are well calibrated at high latitudes. The SST in the Kuroshio Extension region has higher variability than in the Kuroshio region. The variability of the temperature difference between the satellite-retrieved SSTs and the Argo NSTs is lower in the Kuroshio Extension during spring. At low wind speeds, neither TMI nor AMSR-E SSTs are well calibrated, although the TMI performs better than the AMSR-E. 展开更多
关键词 Argo near-surface temperature tropical rainfall measuring mission(TRMM) microwave imager advanced microwave scanning radiometer for the earth observing system sea surface temperature
下载PDF
TEMPERATURE MEASUREMENT OF REFLECTED SHOCK WAVE BY USING CHEMICAL INDICATOR
16
作者 崔季平 何宇中 +2 位作者 王苏 王静 范秉诚 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2000年第1期63-69,共7页
This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction o... This report describes a new method for measuring the temperature of the gas behind the reflected shock wave in shock tube, corresponding to the reservoir temperature of a shock tunnel, based on the chemical reaction of small amount of CF4 premixed in the test gas. The final product C2F4 is used as the temperature indicator, which is sampled and detected by a gas chromatography in the experiment. The detected concentration of C2F4 is correlated to the temperature of the reflected shock wave with the initial pressure P-1 and test time tau as parameters in the temperature range 3 300 K < T < 5 600 K, pressure range 5 kPa < P1 <12 kPa and tau similar or equal to 0.4 ms. 展开更多
关键词 temperature measurement shock tube chemical reaction temperature indicator TETRAFLUOROMETHANE
下载PDF
A technique utilizing chemical reagents for direct measurement of temperature at a local area and its engineering applications
17
作者 M.Saka T.Hasegawa 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2009年第2期149-160,共12页
Temperature is one of the physical quantifies through which quantitative evaluation of the safety and reliability of industrial products can be achieved, and this has been used widely in practice. Under any environmen... Temperature is one of the physical quantifies through which quantitative evaluation of the safety and reliability of industrial products can be achieved, and this has been used widely in practice. Under any environmental condifion, regardless of the size of the object to be inspected, accurate and reliable measurement of temperature is of great practical importance. This review article presents a simple and direct method of temperature measurement, that can be applied to the local areas with difficulty in measuring the temperature by using normal thermometers. In the present article, two different application examples are demonstrated. One addresses the study of the electromigration of solders which are used as bonding metals in electronic devices (micro-structures). The application of the method to the shaft of a motor used in heavy industrial fields is explained as the second. 展开更多
关键词 temperature measurement Chemicalreagents Melting point temperature distribution
下载PDF
High-precision nuclear magnetic resonance probe suitable for in situ studies of high-temperature metallic melts
18
作者 Ao Li Wei Xu +4 位作者 Xiao Chen Bing-Nan Yao Jun-Tao Huo Jun-Qiang Wang Run-Wei Li 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第4期48-55,共8页
High-temperature nuclear magnetic resonance(NMR)has proven to be very useful for detecting the temperatureinduced structural evolution and dynamics in melts.However,the sensitivity and precision of high-temperature NM... High-temperature nuclear magnetic resonance(NMR)has proven to be very useful for detecting the temperatureinduced structural evolution and dynamics in melts.However,the sensitivity and precision of high-temperature NMR probes are limited.Here we report a sensitive and stable high-temperature NMR probe based on laser-heating,suitable for in situ studies of metallic melts,which can work stably at the temperature of up to 2000 K.In our design,a well-designed optical path and the use of a water-cooled copper radio-frequency(RF)coil significantly optimize the signal-to-noise ratio(S/NR)at high temperatures.Additionally,a precise temperature controlling system with an error of less than±1 K has been designed.After temperature calibration,the temperature measurement error is controlled within±2 K.As a performance testing,^(27)Al NMR spectra are measured in Zr-based metallic glass-forming liquid in situ.Results show that the S/NR reaches 45 within 90 s even when the sample's temperature is up to 1500 K and that the isothermal signal drift is better than0.001 ppm per hour.This high-temperature NMR probe can be used to clarify some highly debated issues about metallic liquids,such as glass transition and liquid-liquid transition. 展开更多
关键词 high-temperature NMR probe laser beams temperature measurement metallic melts
下载PDF
In situ temperature measurement of vapor based on atomic speed selection
19
作者 于露 曹俐 +2 位作者 岳子骞 李林 翟跃阳 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期189-192,共4页
We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position... We demonstrate an experimental method for the in situ temperature measurement of atomic vapor using the saturated absorption spectrum. By separately manipulating the frequency of the pump and probe beams, the position of the crossover peaks can move along the spectrum. Different velocity classes of atoms contribute to the crossover during the movement. We study the relationship between the intensity change of peaks and vapor temperature. Our experimental result around room temperature shows a deviation of less than 0.3 K. Compared with traditional thermometry using absorption spectroscopy, higher accuracy can theoretically be achieved with real-time thermometry. 展开更多
关键词 temperature measurement saturated absorption spectrum Doppler broadening atomic velocity distribution
下载PDF
Shock temperature and reflectivity of precompressed H2O up to 350 GPa:Approaching the interior of planets
20
作者 Zhi-Yu He Hua Shu +10 位作者 Xiu-Guang Huang Qi-Li Zhang Guo Jia Fan Zhang Yu-Chun Tu Jun-Yue Wang Jun-Jian Ye Zhi-Yong Xie Zhi-Heng Fang Wen-Bing Pei Si-Zu Fu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第12期405-412,共8页
Using a combination of static precompression and laser-driven shock compression, shock temperature and reflectivity of H2O have been measured up to 350 GPa and 2.1×10~4 K. Here, two calibration standards were app... Using a combination of static precompression and laser-driven shock compression, shock temperature and reflectivity of H2O have been measured up to 350 GPa and 2.1×10~4 K. Here, two calibration standards were applied to enhance temperature measurement reliability. Additionally, in temperature calculations, the discrepancy in reflectivity between active probe beam wavelength and self-emission wavelength has been taken into account to improve the data’s precision.Precompressed water’s temperature–pressure data are in very good agreement with our quantum molecular dynamics model,suggesting a superionic conductor of H2O in the icy planets’ deep interior. A sluggish slope gradually approaching Dulong–Petit limit at high temperature was found at a specific heat capacity. Also, high reflectivity and conductivity were observed at the same state. By analyzing the temperature–pressure diagram, reflectivity, conductivity and specific heat comprehensively at conditions simulating the interior of planets in this work, we found that as the pressure rises, a change in ionization appears; it is supposedly attributed to energetics of bond-breaking in the H2O as it transforms from a bonded molecular fluid to an ionic state. Such molecular dissociation in H2O is associated with the conducting transition because the dissociated hydrogen atoms contribute to electrical properties. 展开更多
关键词 high temperature measurement equation of state of water laser-driven shock diamond anvil cell
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部