期刊文献+
共找到47,390篇文章
< 1 2 250 >
每页显示 20 50 100
Low-temperature characteristicsof rubbers and performance testsof type 120 emergencyvalve diaphragms 被引量:1
1
作者 Ming Gao Anhui Pan +5 位作者 Yi Huang Jiaqi Wang Yan Zhang Xiao Xie Huanre Han Yinghua Jia 《Railway Sciences》 2024年第1期47-58,共12页
Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resista... Purpose–The type 120 emergency valve is an essential braking component of railway freight trains,butcorresponding diaphragms consisting of natural rubber(NR)and chloroprene rubber(CR)exhibit insufficientaging resistance and low-temperature resistance,respectively.In order to develop type 120 emergency valverubber diaphragms with long-life and high-performance,low-temperatureresistant CR and NR were processed.Design/methodology/approach–The physical properties of the low-temperature-resistant CR and NRwere tested by low-temperature stretching,dynamic mechanical analysis,differential scanning calorimetryand thermogravimetric analysis.Single-valve and single-vehicle tests of type 120 emergency valves werecarried out for emergency diaphragms consisting of NR and CR.Findings–The low-temperature-resistant CR and NR exhibited excellent physical properties.The elasticityand low-temperature resistance of NR were superior to those of CR,whereas the mechanical properties of thetwo rubbers were similar in the temperature range of 0℃–150℃.The NR and CR emergency diaphragms metthe requirements of the single-valve test.In the low-temperature single-vehicle test,only the low-temperaturesensitivity test of the NR emergency diaphragm met the requirements.Originality/value–The innovation of this study is that it provides valuable data and experience for futuredevelopment of type 120 valve rubber diaphragms. 展开更多
关键词 Natural rubber Chloroprene rubber Low-temperature characteristic 120 emergency valve DIAPHRAGM
下载PDF
The use of fluoroscopy for detecting hypertensive lung edema due to prosthetic valve dysfunction: a case report
2
作者 Yusuf Kantar Necmi Baykan 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期313-315,共3页
Heart valve diseases affect more than one hundred million people around the world,which are a serious cause of illness and mortality.[1]Among the valve diseases,mitral valve insufficiency ranks second in the list of v... Heart valve diseases affect more than one hundred million people around the world,which are a serious cause of illness and mortality.[1]Among the valve diseases,mitral valve insufficiency ranks second in the list of valve diseases requiring surgical repair in Europe.[2]Prosthetic valve replacement is the standard treatment in cases where repair is not sufficient for valve diseases.[3]Mechanical and bioprosthetic valves can be preferred for replacement,mechanical valves are more durable and require lifelong use of anticoagulants.The disadvantage of bioprosthetic valves is early degeneration,and infective reoperation is required due to the formation of endocarditis.[4-5]The risk of thromboembolism,lifetime anticoagulant use and complications related to anticoagulation remain disadvantages of valve surgery.[3]The most important complication requiring urgent intervention is valve dysfunction due to thrombosis.It usually occurs due to inappropriate use of the anticoagulants.[6]Surgical treatment is used for severe obstructions,such as thrombi larger than 10 mm.Thrombolytic therapy can be applied in small thrombi and in cases where surgical intervention is risky. 展开更多
关键词 valve DISADVANTAGE LIFETIME
下载PDF
Animal Model of Aortic Valve Calcification: Their Methodology Helps Us Understand Aortic Valve Calcification
3
作者 Yinze Wei Zhen Wang +1 位作者 Miao Chen Liang Ma 《Advances in Bioscience and Biotechnology》 CAS 2024年第4期235-268,共34页
Aortic valve calcification disease (CAVD) is the most prevalent degenerative valve disease in humans, leading to significant morbidity and mortality. Despite its common occurrence, our understanding of the underlying ... Aortic valve calcification disease (CAVD) is the most prevalent degenerative valve disease in humans, leading to significant morbidity and mortality. Despite its common occurrence, our understanding of the underlying mechanisms remains incomplete, and available treatment options are limited and risky. A more comprehensive understanding of the biology of CAVD is essential to identify new therapeutic strategies. Animal models have played a crucial role in advancing our knowledge of CAVD and exploring potential treatments. However, these models have inherent limitations as they cannot fully replicate the complex physiological mechanisms of human CAVD. In this review, we examine various CAVD models ranging from pigs to mice, highlighting the unique characteristics of each model to enhance our understanding of CAVD. While these models offer valuable insights, they also have limitations and shortcomings. We propose that the guide wire model shows promise for future CAVD research, and streamlining the methodology could enhance our understanding and expand the research scope in this field. 展开更多
关键词 Animal Model Aortic valve Stenosis CALCIFICATION CARDIOVASCULAR
下载PDF
Psychological Status and Warfarin Therapy in Patients after Valve Replacement during the COVID-19 Pandemic:A Cross-sectional Study
4
作者 Xiao-yan CHEN Sheng HE +6 位作者 Zhen TAN Feng GAO Hui JIANG Lu CHEN Li YANG Yu-shan LIU Si-yi HE 《Current Medical Science》 SCIE CAS 2024年第4期686-691,共6页
Objective The standardization of warfarin anticoagulant therapy is the key to lifelong treatment for patients after heart valve replacement.The present study explored the possible risk factors for anxiety and depressi... Objective The standardization of warfarin anticoagulant therapy is the key to lifelong treatment for patients after heart valve replacement.The present study explored the possible risk factors for anxiety and depression during the coronavirus disease 2019(COVID-19)pandemic and analyzed the influence of psychological state on medication safety.Methods Eligible patients received a web-based questionnaire survey via the Wenjuanxing platform during outpatient visits.Depression was evaluated by the Self-Rating Depression Scale(SDS).Anxiety was evaluated by the Self-Rating Anxiety Scale(SAS).Medication adherence was evaluated by the Morisky scale.Results A total of 309 patients(aged 52.2±11.4 years)were included in the present study.The SDS score of all included patients was 36.9±9.4 points,of which 11(3.6%)patients were diagnosed as having depression.The SAS score of all included patients was 43.1±9.3 points,of which 71(23%)patients were diagnosed as having anxiety.Seven patients(2.3%)had both anxiety and depression.Logistic regression analysis revealed that only monthly income was an independent influencing factor for depression.Regarding anxiety,patients who underwent repeated operations had a 2.264-fold greater risk,and patients who received combination medication had a 2.140-fold greater risk.More bleeding events and coagulation disorders could be observed in patients with anxiety,depression or both.When anxiety occurred,patients showed worse medication adherence.However,depression had no significant effect on medication adherence.Conclusion During the COVID-19 pandemic,the detection rate of mental illnesses such as anxiety and depression was high,which seriously affected the medication safety of warfarin.Analysis of its influencing factors will provide a reference for further standardized regulation of warfarin anticoagulant therapy after valve replacement. 展开更多
关键词 WARFARIN COVID-19 valve replacement DEPRESSION ANXIETY
下载PDF
Transcatheter aortic valve replacement in low-risk young population:A double edge sword?
5
作者 Sukhdeep Bhogal Akash Batta 《World Journal of Cardiology》 2024年第4期177-180,共4页
Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediat... Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediate to highsurgical risk patients.In 2019,the United States Food and Drug Administration approved TAVR in low-risk patients based on two randomized trials.However,these breakthrough trials excluded patients with certain unfavorable anatomies and odd profiles.While currently there is no randomized study of TAVR in young patients,it may be preferred by the young population given the benefits of early discharge,shorter hospital stay,and expedite recovery.Nonetheless,it is important to ruminate various factors including lifetime expectancy,risk of pacemaker implantation,and the need for future valve or coronary interventions in young cohorts before considering TAVR in these patients.Furthermore,the data on long-term durability(>10 years)of TAVR is still unknown given most of the procedures were initially performed in the high or prohibitive surgical risk population.Thus,this editorial aims to highlight the importance of considering an individualized approach in young patients with consideration of various factors including lifetime expectancy while choosing TAVR against surgical aortic valve replacement. 展开更多
关键词 Transcatheter aortic valve replacement Surgical aortic valve replacement Pacemaker implantation Coronary re-access Structural deterioration
下载PDF
Electric-controlled pressure relief valve for enhanced safety in liquid-cooled lithium-ion battery packs
6
作者 Yuhang Song Jidong Hou +6 位作者 Nawei Lyu Xinyuan Luo Jingxuan Ma Shuwen Chen Peihao Wu Xin Jiang Yang Jin 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第3期98-109,I0004,共13页
The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above... The liquid-cooled battery energy sto rage system(LCBESS) has gained significant attention due to its superior thermal management capacity.However,liquid-cooled battery pack(LCBP) usually has a high sealing level above IP65,which can trap flammable and explosive gases from battery thermal runaway and cause explosions.This poses serious safety risks and challenges for LCBESS.In this study,we tested overcharged battery inside a commercial LCBP and found that the conventionally mechanical pressure relief valve(PRV) on the LCBP had a delayed response and low-pressure relief efficiency.A realistic 20-foot model of an energy storage cabin was constructed using the Flacs finite element simulation software.Comparative studies were conducted to evaluate the pressure relief efficiency and the influence on neighboring battery packs in case of internal explosions,considering different sizes and installation positions of the PRV.Here,a newly developed electric-controlled PRV integrated with battery fault detection is introduced,capable of starting within 50 ms of the battery safety valve opening.Furthermore,the PRV was integrated with the battery management system and changed the battery charging and discharging strategy after the PRV was opened.Experimental tests confirmed the efficacy of this method in preventing explosions.This paper addresses the safety concerns associated with LCBPs and proposes an effective solution for explosion relief. 展开更多
关键词 Pressure relief valve Liquid-cooled battery pack Explosion Flacs
下载PDF
Isogeometric Analysis of Hyperelastic Material Characteristics for Calcified Aortic Valve
7
作者 Long Chen Ting Li +3 位作者 Liang Liu Wenshuo Wang Xiaoxiao Du Wei Wang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第6期2773-2806,共34页
This study explores the implementation of computed tomography(CT)reconstruction and simulation techniques for patient-specific valves,aiming to dissect the mechanical attributes of calcified valves within transcathete... This study explores the implementation of computed tomography(CT)reconstruction and simulation techniques for patient-specific valves,aiming to dissect the mechanical attributes of calcified valves within transcatheter heart valve replacement(TAVR)procedures.In order to facilitate this exploration,it derives pertinent formulas for 3D multi-material isogeometric hyperelastic analysis based on Hounsfield unit(HU)values,thereby unlocking foundational capabilities for isogeometric analysis in calcified aortic valves.A series of uniaxial and biaxial tensile tests is executed to obtain an accurate constitutive model for calcified active valves.To mitigate discretization errors,methodologies for reconstructing volumetric parametric models,integrating both geometric and material attributes,are introduced.Applying these analytical formulas,constitutive models,and precise analytical models to isogeometric analyses of calcified valves,the research ascertains their close alignment with experimental results through the close fit in displacement-stress curves,compellingly validating the accuracy and reliability of the method.This study presents a step-by-step approach to analyzing themechanical characteristics of patient-specific valves obtained fromCT images,holding significant clinical implications and assisting in the selection of treatment strategies and surgical intervention approaches in TAVR procedures. 展开更多
关键词 Calcified aortic valves tensile test constitutive relations CT reconstruction isogeometric hyperelastic analysis
下载PDF
Early Prosthetic Valve Endocarditis with Mycobacterium Tuberculosis after Mitral Valve Replacement: A Case Report
8
作者 Papa Amath Diagne Mory Camara +12 位作者 Papa Ousmane Ba Momar Sokhna Diop Moussa Samba Abdou Lahad Mbengue Jean Claude Ndiogou Dione Myriam Bizrane Marième Soda Mbaye Moussa Seck Diop Toudiani Malam Kaka Papa Salmane Ba Papa Adama Dieng Amadou Gabriel Ciss Assane Ndiaye 《World Journal of Cardiovascular Surgery》 2024年第3期33-40,共8页
Background: Tuberculous endocarditis is a rare but serious complication of heart valve replacement surgery. We report the case of a 24-year-old patient, who presented with tuberculous endocarditis after mechanical mit... Background: Tuberculous endocarditis is a rare but serious complication of heart valve replacement surgery. We report the case of a 24-year-old patient, who presented with tuberculous endocarditis after mechanical mitral valve replacement, with a favorable clinical course following anti-tuberculosis treatment. Case Presentation: We report a 24-year-old male patient, admitted to the cardiac surgery department of the Fann Hospital (Dakar, Senegal), for the management of severe mixed (rheumatic and endocarditic) mitral insufficiency with associated tricuspid insufficiency. He had a history of recurrent angina and polyarthralgia in childhood, was hospitalized several times for refractory global cardiac decompensation, and for a suspected infective endocarditis a month before his admission. On admission, the clinical examination revealed signs suggestive of mitral and tricuspid insufficiency. Transthoracic echocardiography revealed severe post-endocarditic mitral insufficiency with A3 amputation, highly mobile 15 mm vegetations on the free edge of the large valve, moderate tricuspid insufficiency, and severe pulmonary artery hypertension. Mechanical mitral valve replacement and tricuspid valve annuloplasty using autologous pericardial strip were performed via median sternotomy. After ten days, the patient presented with global cardiac decompensation associated with a clinico-biological infectious syndrome, and tans-oesophageal echography revealed an abscess at the sinotubular junction, communicating with the aorta. A thoraco-abdomino-pelvic CT scan was done, which revealed a bilateral alveolar-interstitial syndrome with mediastinal lymphadenopathy. Anti-tuberculosis treatment with RHZE was initiated for 06 months. The clinical course was favorable. Conclusion: Tuberculous endocarditis in prostheses is a serious complication of heart valve replacement surgery, which may evolve favorably under medical treatment. 展开更多
关键词 Tuberculous Endocarditis Prosthetic valve Endocarditis Mycobacterium Tuberculosis
下载PDF
Switching Frequency Improvement of a High Speed on/off Valve Based on Pre-excitation Control Algorithm
9
作者 Qi Zhong Xiaotian Li +4 位作者 Yongxin Mao Enguang Xu Tiwei Jia Yanbiao Li Huayong Yang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第4期94-106,共13页
The high-speed on/off valve(HSV)serves as the fundamental component responsible for generating discrete fluids within digital hydraulic systems.As the switching frequency of the HSV increases,the properties of the gen... The high-speed on/off valve(HSV)serves as the fundamental component responsible for generating discrete fluids within digital hydraulic systems.As the switching frequency of the HSV increases,the properties of the generated discrete fluid approach those of continuous fluids.Therefore,a higher frequency response characteristic of HSV is the key to ensure the control accuracy of digital hydraulic systems.However,the current research mainly focuses on its dynamic performance,but neglect its FRC.This paper presents a theoretical analysis demonstrating that the FRC of the HSV can be enhanced by minimizing its switching time.The maximum switching frequency(MSF)is mainly determined by opening dynamic performance when HSV operates with low switching duty ratio(SDR),whereas the closing dynamic performance limits the MSF when HSV operates with high SDR.Building upon these findings,the pre-excitation control algorithm(PECA)is proposed to reduce the switching time of the HSV,and consequently enhance its FRC.Experimental results demonstrate that PECA shortens the opening delay time of HSV by 1.12 ms,the closing delay time by 2.54 ms,and the closing moving time by 0.47 ms in comparison to the existing advanced control algorithms.As a result,a larger MSF of 417 Hz and a wider controllable SDR range from 20%to 70%were achieved at a switching frequency of 250 Hz.Thus,the proposed PFCA in this paper has been verified as an effective and promising approach for enhancing the control performance of digital hydraulic systems. 展开更多
关键词 High speed on/off valve Switching frequency Pre-excitation Dynamic performance Switching duty ratio
下载PDF
Rates, predictors, and causes of readmission after transcatheter aortic valve replacement in patients with chronic kidney disease
10
作者 Taha Teaima Gianfranco Bittar Carlini +5 位作者 Rohan A Gajjar Imran Aziz Sami J Shoura Abdul-Rahim Shilbayeh Naim Battikh Tareq Alyousef 《World Journal of Cardiology》 2024年第7期402-411,共10页
BACKGROUND Transcatheter aortic valve replacement(TAVR)is a revolutionary procedure for severe aortic stenosis.The coexistence of chronic kidney disease(CKD)and TAVR introduces a challenge that significantly impacts p... BACKGROUND Transcatheter aortic valve replacement(TAVR)is a revolutionary procedure for severe aortic stenosis.The coexistence of chronic kidney disease(CKD)and TAVR introduces a challenge that significantly impacts patient outcomes.AIM To define readmission rates,predictors,and causes after TAVR procedure in CKD stage 1-4 patients.METHODS We used the national readmission database 2018 and 2020 to look into readmission rates,causes and predictors after TAVR procedure in patients with CKD stage 1-4.RESULTS Out of 24758 who underwent TAVR and had CKD,7892(32.4%)patients were readmitted within 90 days,and had higher adjusted odds of being females(adjusted odds ratio:1.17,95%CI:1.02-1.31,P=0.02)with longer length of hospital stay>6 days,and more comorbidities including but not limited to diabetes mellitus,anemia,and congestive heart failure(CHF).CONCLUSION Most common causes of readmission included CHF(18.0%),sepsis,and complete atrioventricular block.Controlling readmission predictors with very close followup is warranted to prevent such high rate of readmission. 展开更多
关键词 Chronic kidney disease Transcatheter aortic valve replacement READMISSION PREDICTORS Rates
下载PDF
Risk of permanent pacemaker implantation following transcatheter aortic valve replacement:Which factors are most relevant?
11
作者 Akash Batta Juniali Hatwal 《World Journal of Cardiology》 2024年第2期49-53,共5页
Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized ... Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized controlled trials has resulted in an exponential rise in the use of TAVR even in the low-risk patients.However,this is not without challenges.Need for permanent pacemaker(PPM)post-TAVR remains the most frequent and clinically relevant challenge.Naturally,identifying risk factors which predispose an individual to develop high grade conduction block post-TAVR is important.Various demographic factors,electrocardiographic features,anatomic factors and procedural characteristics have all been linked to the development of advanced conduction block and need for PPM following TAVR.Amongst these electrophysiological variables,most notably a prolonged QRS>120 ms regardless of the type of conduction block seems to be one of the strongest predictors on logistic regression models.The index study by Nwaedozie et al highlights that patients requiring PPM post-TAVR had higher odds of having a baseline QRS>120 ms and were more likely to be having diabetes mellitus that those who did not require PPM. 展开更多
关键词 Transcatheter aortic valve replacement Permanent pacemaker Diabetes mellitus QRS duration Electrophysiological variables
下载PDF
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention?
12
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Predictors of permanent pacemaker implantation following transcatheter aortic valve replacement-the search is still on!
13
作者 Sudesh Prajapathi Akshyaya Pradhan 《World Journal of Cardiology》 2024年第3期104-108,共5页
Several anatomical,demographic,clinical,electrocardiographic,procedural,and valve-related variables can be used to predict the probability of developing con-duction abnormalities after transcatheter aortic valve repla... Several anatomical,demographic,clinical,electrocardiographic,procedural,and valve-related variables can be used to predict the probability of developing con-duction abnormalities after transcatheter aortic valve replacement(TAVR)that necessitate permanent pacemaker(PPM)implantation.These variables include calcifications around the device landing zone and in the mitral annulus;pre-existing electrocardiographic abnormalities such as left and right bundle branch blocks(BBB),first-and second-degree atrioventricular blocks,as well as bifas-cicular and trifascicular blocks;male sex;diabetes mellitus(DM);hypertension;history of atrial fibrillation;renal failure;dementia;and use of self-expanding valves.The current study supports existing literature by demonstrating that type 2 DM and baseline right BBB are significant predictors of PPM implantation post-TAVR.Regardless of the side of the BBB,this study demonstrated,for the first time,a linear association between the incidence of PPM implantation post-TAVR and every 20 ms increase in baseline QRS duration(above 100 ms).After a 1-year follow-up,patients who received PPM post-TAVR had a higher rate of hospital-ization for heart failure and nonfatal myocardial infarction. 展开更多
关键词 Bundle branch block Self expanding aortic valve Atrioventricular node Diabetes mellitus QRS duration
下载PDF
Prognostic Role of Preoperative Tricuspid Annular Plane Systolic Excursion (TAPSE) in Mitral Valve Replacement (MVR) for Rheumatic Mitral Stenosis Patients
14
作者 Satyajit Sharma Muhit Abdullah +9 位作者 Md. Noor-E-Elahi Mozumder Munjerin Refat Synthee Md. Zafar-Al-Nimari Anowarul Azim Saikat Das Gupta Dewan Iftakher Raza Chowdhury Siddhartha Shankar Howlader Noel Crypian Gomes Saleh Ahmed Samir Kumar Biswas 《World Journal of Cardiovascular Surgery》 2024年第8期115-130,共16页
Tricuspid annular plane systolic excursion has been proposed as a simple and reproducible parameter for quantitative assessment of the right ventricular ejection fraction. The prognostic importance of preoperative TAP... Tricuspid annular plane systolic excursion has been proposed as a simple and reproducible parameter for quantitative assessment of the right ventricular ejection fraction. The prognostic importance of preoperative TAPSE in patients with mitral valve replacement for rheumatic mitral stenosis patients is still under focused. Therefore, the objective of the study was to predict the outcome after MVR in rheumatic mitral stenosis patients in relation to preoperative TAPSE. This comparative cross-sectional study was conducted at the Department of Cardiac Surgery, National Heart Foundation Hospital and Research Institute. A total of 72 patients of rheumatic mitral stenosis patients who underwent mitral valve replacement were included in the study. They were divided into two groups: Group A and B. Group A included 36 patients with TAPSE 0.05) except for the preoperative TAPSE. Mean TAPSE of Group A was 13.17 (±1.40) and Group B was 18.61 (±1.57), the difference was statistically significant (p 0.05). Among the postoperative complications, including postoperative atrial fibrillation was higher in Group A (30.56%) than Group B (11.11%), mean ventilation time was higher in Group A (27.78%) than Group B (5.56%), length of intensive care was higher in Group A (33.33%) than Group B (11.12%), and hospital stay was higher in Group A (25.0%) than Group B (5.56%), (p < 0.05). Higher preoperative TASPE could be used as a prognostic tool for MVR in rheumatic mitral stenosis patients in our settings. 展开更多
关键词 Tricuspid Annular Plane Systolic Excursion Mitral valve Replacement Rheumatic Heart Disease Mitral Stenosis Right Ventricular Ejection Fraction Postoperative Complications
下载PDF
Effect of safety valve types on the gas venting behavior and thermal runaway hazard severity of large-format prismatic lithium iron phosphate batteries
15
作者 Zhuangzhuang Jia Yuanyuan Min +5 位作者 Peng Qin Wenxin Mei Xiangdong Meng Kaiqiang Jin Jinhua Sun Qingsong Wang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第2期195-207,I0006,共14页
The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the ... The safety valve is an important component to ensure the safe operation of lithium-ion batteries(LIBs).However,the effect of safety valve type on the thermal runaway(TR)and gas venting behavior of LIBs,as well as the TR hazard severity of LIBs,are not known.In this paper,the TR and gas venting behavior of three 100 A h lithium iron phosphate(LFP)batteries with different safety valves are investigated under overheating.Compared to previous studies,the main contribution of this work is in studying and evaluating the effect of gas venting behavior and TR hazard severity of LFP batteries with three safety valve types.Two significant results are obtained:(Ⅰ)the safety valve type dominates over gas venting pressure of battery during safety venting,the maximum gas venting pressure of LFP batteries with a round safety valve is 3320 Pa,which is one order of magnitude higher than other batteries with oval or cavity safety valve;(Ⅱ)the LFP battery with oval safety valve has the lowest TR hazard as shown by the TR hazard assessment model based on gray-fuzzy analytic hierarchy process.This study reveals the effect of safety valve type on TR and gas venting,providing a clear direction for the safety valve design. 展开更多
关键词 Lithium iron phosphate battery Safety valve Thermal runaway Gas venting behavior Thermal runaway hazard severity Gray-fuzzy analytic hierarchy process
下载PDF
Research on static characteristic of double redundance double nozzle flapper valve based on AMESim
16
作者 孙亚南 LIANG Qiuhui +2 位作者 WANG Wentao YANG Guang ZHANG Wei 《High Technology Letters》 EI CAS 2024年第2期164-169,共6页
The feedback spring rod of the armature assembly is cancelled in the double redundance double nozzle flapper valve(DRDNFV),and the difficulty of valve core displacement control is increased.Therefore,this paper intend... The feedback spring rod of the armature assembly is cancelled in the double redundance double nozzle flapper valve(DRDNFV),and the difficulty of valve core displacement control is increased.Therefore,this paper intends to study the static characteristic of DRDNFV through the AMESet and AMESim simulation.It is explored under the circumstance of the fixed orifices being clogged and experimentally verified on the test bench.The results show that the pressure gain increases and the flow gain decreases with the increasing clogged degree of the fixed orifices on both sides.The zero bias increases synchronously with the increasing clogged degree of the unilateral fixed orifice.The experimental results are basically consistent with the theoretical curves and the theoretical correctness of the simulation model is effectively verified.The results can provide the theoretical reference for design,debugging,maintenance and fault diagnosis of DRDNFV. 展开更多
关键词 double redundance double nozzle flapper valve(DRDNFV) AMESet torquemotor armature assembly fault diagnosis
下载PDF
Pacemaker post transcatheter aortic valve replacement:A multifactorial risk?
17
作者 Stephane Noble Karim Bendjelid 《World Journal of Cardiology》 2024年第4期168-172,共5页
Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have a... Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have at least as much impact on the final need for a permanent pacemaker and potentially on the pacing rate.In this regard,long-term follow-up and understanding of the impact of long-term stimulation is of utmost importance. 展开更多
关键词 Transcatheter aortic valve replacement Permanent pacemaker implantation Conduction abnormalities Right bundle branch block Left bundle branch block
下载PDF
A Rare Case of Aortic Valve Endocarditis and Acute Meningitis Due to Haemophilus influenzae
18
作者 Zachary M. Visinoni Justin D. Tse Christopher F. Pease 《Case Reports in Clinical Medicine》 2024年第6期207-211,共5页
HACEK organisms represent a rare but important group of causative pathogens in endocarditis. These bacteria have historically been associated with culture-negative endocarditis;however, modern laboratory techniques ha... HACEK organisms represent a rare but important group of causative pathogens in endocarditis. These bacteria have historically been associated with culture-negative endocarditis;however, modern laboratory techniques have made this less common. In this case, we present a 74-year-old man who presented with acute onset altered mentation, fever, and sepsis. He was ultimately found to have Haemophilus influenzae meningitis, cerebral empyema, aortic valve endocarditis, psoas myositis, and L2 - L3 diskitis with osteomyelitis. Although HACEK organisms are commonly found in the oropharynx and upper respiratory tract in humans, our patient did not report recent preceding dental or ENT procedures. H. influenzae is responsible for approximately 0.16% of all cases of bacterial endocarditis, representing a very limited subset. Although generally considered low virulent pathogens, this case demonstrates the unusual extent of infection from a HACEK organism, H. influenzae, causing aortic valve endocarditis as well as atypical non-cardiac sequelae, including acute meningitis. 展开更多
关键词 HACEK Haemophilus influenzae Aortic valve Endocarditis Bacterial Meningitis Cerebral Empyema
下载PDF
In-Hospital Outcomes in Minimally Invasive Mitral Valve Surgery: First Results in a Brazilian Single Center
19
作者 Daniel de Magalhães Freitas João Alberto Pansani +4 位作者 Max Weyler Nery Stanlley de Oliveira Loyola Maurício Lopes Prudente Giulliano Gardenghi Artur Henrique de Souza 《Open Journal of Thoracic Surgery》 2024年第1期17-28,共12页
Introduction: Treatments for cardiovascular diseases have increasingly evolved with the tendency to offer minimally invasive or transcatheter procedures instead of conventional sternotomy surgery. In this context, we ... Introduction: Treatments for cardiovascular diseases have increasingly evolved with the tendency to offer minimally invasive or transcatheter procedures instead of conventional sternotomy surgery. In this context, we highlight minimally invasive mitral valve surgery (MIMVS), which has been shown to be an increasingly solid option with some superior results when compared to the conventional technique: better pain control, shorter hospital stays, shorter recovery time, shorter readmission rate in the first postoperative year, better aesthetic results, and lower overall cost. Aim: This study aims to evaluate the stages of MIMVS, by primary mitral valve consultation, in our service and compare these results with data from the literature. Methods: All electronic medical records of patients who underwent MIMVS for primary mitral valve injury in the Encore Hospital from January 2020 to February 2023 were analyzed. Tabulation and statistical analysis were performed using the Microsoft Excel<sup>®</sup> program. Quantitative variables were presented as means, standard deviations. Results: 46 patients were enrolled in our study (Age: 59.1 ± 12.4 years old;60.8% Female, BMI: 26 ± 4.4 Kg/m<sup>2</sup>, Low risk STS score: 82.6%). The observed 30-day mortality was 2.1%, plastic rate of 23.9%, blood transfusion rate of 41.3%, length of stay in an intensive care bed (ICB) of 3.3 ± 3.3 days and hospital stay of 6.4 ± 5.1 days. Conclusions: We noticed that the MIMVS results carried out in our service agree with data from national and international literature with approximately 1.3 days more hospitalization in ICB. 展开更多
关键词 Minimally Invasive Surgical Procedures Mitral valve Outcome Assessment Health Care
下载PDF
The Impact of Temperature on the Electromagnet and Structural Optimization of a Solenoid Valve
20
作者 Zhixiong Tang Zhijun Feng 《Journal of Electronic Research and Application》 2024年第1期28-35,共8页
The mathematical model of the solenoid valve under varying temperatures is constructed to investigate its performance and enhance heat dissipation balance.The relationship between temperature and electromagnetic force... The mathematical model of the solenoid valve under varying temperatures is constructed to investigate its performance and enhance heat dissipation balance.The relationship between temperature and electromagnetic force is determined.Electrothermal coupling simulation using COMSOL is conducted,optimizing the outer diameter and length structure parameters of the coil.It is established that the heat dissipation of the coil is influenced by its outer diameter.Subsequently,based on optimized coil structure parameters,an orthogonal experimental design method combined with Ansys Maxwell is employed for simulation solution analysis to study the impact of structural parameters such as length,position,front and rear angles of the magnetic barrier ring in the iron core,armature length,and through-hole size on electromagnetic force.Optimal structural parameters are identified.Results indicate a decrease in steady-state electromagnet temperature by 3-4℃,an increase in the initial electromagnetic force by 32.63%,and a rise in the maximum electromagnetic force by 27.10%. 展开更多
关键词 Solenoid valve ELECTROMAGNET TEMPERATURE Electromagnetic force
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部