期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Improved Cardiac Contractility of Human Recombinant Growth Hormone on the Congestive Heart Failure of Pig
1
作者 YangPing HeYu-quan +4 位作者 ZengHong NiJin-song YunQing-jun HuangXiao-ping LiShu-mei 《Journal of Bionic Engineering》 SCIE EI CSCD 2005年第2期87-91,共5页
The enhanced cardiac contractility effect of human recombinant growth hormone (hr-GH) on the congestive heart failure (CHF) was studied on the pig. To build a pig model of congestive heart failure, a temporary artific... The enhanced cardiac contractility effect of human recombinant growth hormone (hr-GH) on the congestive heart failure (CHF) was studied on the pig. To build a pig model of congestive heart failure, a temporary artificial cardiac pacemaker was implanted in the pig’s body and paced at 220 beats to 240 beats per minute for 1 week. After the model of congestive heart failure was successfully set up, the frequency of the pacemaker was changed to 150 beats to 180 beats per minute to maintain the CHF model stable. Pigs were divided into three groups: The hr-GH group in which 0.5 mg/kg per day of hr-GH was administrated intramuscularly for 15 days, the injection control group in which an equal amount of physiological saline was injected intramuscularly, and a normal control group. The left ventricular diastolic end pressure was (10.60±2.41) mmHg in the hr-GH group, but (19.00±3.81) mmHg in the saline control group (P<0.01); Cardiac output was (1.86±0.13) L/min in the hr-GH group, but (1.56±0.18) L/min in the saline control group (P<0.05); Peripheral vascular resistance was (56.88±7.51) mmHg·(L/min) -1 in the hr-GH group, whereas (70.30±11.59) mmHg·(L/min) -1 in the saline control group (P<0.05); +dp/dt max was (2900±316.23) and (2280±286.36) in the hr-HG group and the saline control group respectively (P<0.05). The results show that hr-GH enhances myocardial contractility of CHF, and the CHF model built by a temporary artificial cardiac pacemaker at a high rate of stimulation is reasonable and applicable. 展开更多
关键词 human recombinant growth hormone improved cardiac contractility experimental animal model temporary artificial cardiac pacemaker congestive heart failure
下载PDF
Clinical application of temporary pacemaker insertion guided by bedside ultrasound in elder and critical patients
2
作者 HUANG Dao-zheng YAO Bo-qian +10 位作者 SONG Fei-er CHEN Shuo SU Ke XIAO Zhi-yuan LI Hua LIN Sheng-bin CHEN Ying Ma Huan WANG Shou-hong WU Yan QIN Tie-he 《South China Journal of Cardiology》 CAS 2017年第3期188-194,共7页
Background Ultrasound-guided temporary pacemaker implantation has been proven safe and efficient. However, few studies have focused on elder and critical patients. Methods Twelve elder and critical patients underwent ... Background Ultrasound-guided temporary pacemaker implantation has been proven safe and efficient. However, few studies have focused on elder and critical patients. Methods Twelve elder and critical patients underwent temporary cardiac pacing through the jugular vein or subclavian vein, with bedside ultrasound images to assist the placement of electrode within the right ventricle. Results Ultrasound-guided temporary cardiac pacemaker insertion was successful in all of the 12 patients. Electrodes were sent into the right ventricle correctly with the help of ultrasound imaging. In all cases, temporary pacemaker functioned well without procedure-related complications. Conclusion Temporary cardiac pacing guided by ultrasound is safe and effective in elder and critical patients, which is worth of promoting, especially in intensive care unit. 展开更多
关键词 ULTRASOUND-GUIDED temporary cardiac pacemaker insertion ELDERLY critically ill
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部