In this paper, an optimal H∞ control algorithm was applied to the design of an active tendon system installed at the first story of a multi-story building to reduce its interstory drift due to earthquake excitations....In this paper, an optimal H∞ control algorithm was applied to the design of an active tendon system installed at the first story of a multi-story building to reduce its interstory drift due to earthquake excitations. To achieve optimal control performance and to guarantee the stability of the control system, an optimum strategy to select control parameters γ and α was developed. Analytical expressions of the upper and the lower bounds of γ and α were obtained for a single degree-of-freedom system with state feedback control. The selection ranges for both γ and α are graphically defined so that the controlled system is always stable and the control performance is better than by the conventional LQR control algorithm. Numerical results from a controlled three-story building under real earthquake excitations demonstrate that the peak first interstory drift can be significantly reduced with maximum control force around 10% of the building weight. An optimum design flow chart was provided. In addition, for a time-delayed structure, this study gave explicit formulae to calculate the critical values of γ and a. The system stability and control performance can thus be guaranteed even with time delay.展开更多
基金Ministry of Education and the Science Council (NSC) of Taiwan Under the ATU plan and Grants No. NSC 95-2625-Z-005-009
文摘In this paper, an optimal H∞ control algorithm was applied to the design of an active tendon system installed at the first story of a multi-story building to reduce its interstory drift due to earthquake excitations. To achieve optimal control performance and to guarantee the stability of the control system, an optimum strategy to select control parameters γ and α was developed. Analytical expressions of the upper and the lower bounds of γ and α were obtained for a single degree-of-freedom system with state feedback control. The selection ranges for both γ and α are graphically defined so that the controlled system is always stable and the control performance is better than by the conventional LQR control algorithm. Numerical results from a controlled three-story building under real earthquake excitations demonstrate that the peak first interstory drift can be significantly reduced with maximum control force around 10% of the building weight. An optimum design flow chart was provided. In addition, for a time-delayed structure, this study gave explicit formulae to calculate the critical values of γ and a. The system stability and control performance can thus be guaranteed even with time delay.