The load transfer characteristics of a tensile anchor in the rock mass with weak interlayers were investigated,considering the nonuniform stress of the horizontally layered rock mass along anchors.An improved shear-sl...The load transfer characteristics of a tensile anchor in the rock mass with weak interlayers were investigated,considering the nonuniform stress of the horizontally layered rock mass along anchors.An improved shear-slipping model was proposed to describe the stress evolution characteristics of the bolt-rock interface.Based on the improved model,analytical solutions of the axial force,shear stress distribution and load-displacement relationship considering the residual stress stage were established.The effects of the stratigraphic sequence,pulling force and bolt diameter on the stress distribution of the anchorage interface were evaluated by using analytical solutions.The results were verified by applying the finite difference numerical simulation method.The sensitivity of each parameter to the axial force and shear stress of the rock bolt was determined based on calculation of the sensitivity coefficient.The study results show that the axial force and shear stress tend to decrease nonuniformly along the rock bolt towards the anchorage depth.Due to the existence of weak interlayers,the shear stress mutates at the weak and hard rock interface,and the axial force appears to“rebound”at the bottom of the anchored section.Lithology has more significant effects on the axial force and shear stress at the bottom of the anchor than at the top of the anchor.The pulling force is more sensitive to the anchor stress than stratigraphic sequence when the bolt diameter is determined.This study provides a theoretical framework for the fundamental problem of tensile bolts in horizontally or vertically laminated rock masses,providing a theoretical basis for anchor design.展开更多
This paper introduces the stress and deformation of anti floating anchor rod and explained the damage. Through field testing and numerical analysis, the article were studied the displacement and internal force of a ba...This paper introduces the stress and deformation of anti floating anchor rod and explained the damage. Through field testing and numerical analysis, the article were studied the displacement and internal force of a basement tensile anti float anchor, results showed that: the axial force of bolt tension transfer is top-down transfer, axial force decreases, the stress concentrate on the end. When a force is applied to a certain load, end firstly generate damage, but with the deepening of the axial force, it is greatly reduced, which indicates that the anchor force is an effective length, rather than the longer the anchor pullout force is bigger; anchor group effect is a problem that can not be ignored, because the engineering community for its attention degree is not enough, so that the design of anti floating anchor the lack of a reliable basis, the test results can provide a reference for the future design of anti floating anchor. Prestressed anchors in the tension lock, prestressed loss are regularly.展开更多
An experimental investigation on the seismic behavior of a type of outrigger truss-reinforced concrete wall shear connection using multiple steel angles is presented. Six large-scale shear connection models, which inv...An experimental investigation on the seismic behavior of a type of outrigger truss-reinforced concrete wall shear connection using multiple steel angles is presented. Six large-scale shear connection models, which involved a portion of reinforced concrete wall and a shear tab welded onto a steel endplate with three steel angles, were constructed and tested under combined actions of cyclic axial load and eccentric shear. The effects of embedment lengths of steel angles, wall boundary elements, types of anchor plates, and thicknesses of endplates were investigated. The test results indicate that properly detailed connections exhibit desirable seismic behavior and fail due to the ductile fracture of steel angles. Wall boundary elements provide beneficial confinement to the concrete surrounding steel angles and thus increase the strength and stiffness of connections. Connections using whole anchor plates are prone to suffer concrete pry-out failure while connections with thin endplates have a relatively low strength and fail due to large inelastic deformations of the endplates. The current design equations proposed by Chinese Standard 04G362 and Code GB50011 significantly underestimate the capacities of the connection models. A revised design method to account for the influence of previously mentioned test parameters was developed.展开更多
基金supported by the National Key R&D Program of China(Nos.2018YFC1505300,2017YFC1501304)National Natural Science Foundation of China(Grout Nos.42090054,41922055 and 41931295)+2 种基金the Fundamental Research Funds for the Central Universities,China University of Geosciences(Wuhan)(No.CUGGC09)Research Project of China Three Gorges Corporation(No.2019073)the Zhejiang Huadong Construction Engineering Co.,Ltd.(No.KY2019-HDJS-07)。
文摘The load transfer characteristics of a tensile anchor in the rock mass with weak interlayers were investigated,considering the nonuniform stress of the horizontally layered rock mass along anchors.An improved shear-slipping model was proposed to describe the stress evolution characteristics of the bolt-rock interface.Based on the improved model,analytical solutions of the axial force,shear stress distribution and load-displacement relationship considering the residual stress stage were established.The effects of the stratigraphic sequence,pulling force and bolt diameter on the stress distribution of the anchorage interface were evaluated by using analytical solutions.The results were verified by applying the finite difference numerical simulation method.The sensitivity of each parameter to the axial force and shear stress of the rock bolt was determined based on calculation of the sensitivity coefficient.The study results show that the axial force and shear stress tend to decrease nonuniformly along the rock bolt towards the anchorage depth.Due to the existence of weak interlayers,the shear stress mutates at the weak and hard rock interface,and the axial force appears to“rebound”at the bottom of the anchored section.Lithology has more significant effects on the axial force and shear stress at the bottom of the anchor than at the top of the anchor.The pulling force is more sensitive to the anchor stress than stratigraphic sequence when the bolt diameter is determined.This study provides a theoretical framework for the fundamental problem of tensile bolts in horizontally or vertically laminated rock masses,providing a theoretical basis for anchor design.
文摘This paper introduces the stress and deformation of anti floating anchor rod and explained the damage. Through field testing and numerical analysis, the article were studied the displacement and internal force of a basement tensile anti float anchor, results showed that: the axial force of bolt tension transfer is top-down transfer, axial force decreases, the stress concentrate on the end. When a force is applied to a certain load, end firstly generate damage, but with the deepening of the axial force, it is greatly reduced, which indicates that the anchor force is an effective length, rather than the longer the anchor pullout force is bigger; anchor group effect is a problem that can not be ignored, because the engineering community for its attention degree is not enough, so that the design of anti floating anchor the lack of a reliable basis, the test results can provide a reference for the future design of anti floating anchor. Prestressed anchors in the tension lock, prestressed loss are regularly.
基金National Natural Science Foundation of China under Grant Nos.51008300 and 51478459the China Postdoctoral Science Foundation under Grant No.2013M540476+1 种基金the Fundamental Research Funds for the Central Universities under Grant No.2012QNA56a Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)under Project No.Suzhengbanfa(2014)-No.37
文摘An experimental investigation on the seismic behavior of a type of outrigger truss-reinforced concrete wall shear connection using multiple steel angles is presented. Six large-scale shear connection models, which involved a portion of reinforced concrete wall and a shear tab welded onto a steel endplate with three steel angles, were constructed and tested under combined actions of cyclic axial load and eccentric shear. The effects of embedment lengths of steel angles, wall boundary elements, types of anchor plates, and thicknesses of endplates were investigated. The test results indicate that properly detailed connections exhibit desirable seismic behavior and fail due to the ductile fracture of steel angles. Wall boundary elements provide beneficial confinement to the concrete surrounding steel angles and thus increase the strength and stiffness of connections. Connections using whole anchor plates are prone to suffer concrete pry-out failure while connections with thin endplates have a relatively low strength and fail due to large inelastic deformations of the endplates. The current design equations proposed by Chinese Standard 04G362 and Code GB50011 significantly underestimate the capacities of the connection models. A revised design method to account for the influence of previously mentioned test parameters was developed.