In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses...In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses and strong disturbances and construction conditions such as the application of high prestress.It is essential to study the support components performance under dynamic-static coupling conditions.Based on this,a multi-functional anchorage support dynamic-static coupling performance test system(MAC system)is developed,which can achieve 7 types of testing functions,including single component performance,anchored net performance,anchored rock performance and so on.The bolt and cable mechanical tests are conducted by MAC system under different prestress levels.The results showed that compared to the non-prestress condition,the impact resistance performance of prestressed bolts(cables)is significantly reduced.In the prestress range of 50–160 k N,the maximum reduction rate of impact energy resisted by different types of bolts is 53.9%–61.5%compared to non-prestress condition.In the prestress range of 150–300 k N,the impact energy resisted by high-strength cable is reduced by76.8%–84.6%compared to non-prestress condition.The MAC system achieves dynamic-static coupling performance test,which provide an effective means for the design of anchorage support system.展开更多
A multi-purpose prototype test system is developed to study the mechanical behavior of tunnel sup-porting structure,including a modular counterforce device,a powerful loading equipment,an advanced intelligent manageme...A multi-purpose prototype test system is developed to study the mechanical behavior of tunnel sup-porting structure,including a modular counterforce device,a powerful loading equipment,an advanced intelligent management system and an efficient noncontact deformation measurement system.The functions of the prototype test system are adjustable size and shape of the modular counterforce structure,sufficient load reserve and accurate loading,multi-connection linkage intelligent management,and high-precision and continuously positioned noncontact deformation measurement.The modular counterforce structure is currently the largest in the world,with an outer diameter of 20.5 m,an inner diameter of 16.5 m and a height of 6 m.The case application proves that the prototype test system can reproduce the mechanical behavior of the tunnel lining during load-bearing,deformation and failure processes in detail.展开更多
Virtual instrument is playing the important role in automatic test system. This paper introduces a composition of a virtual instrument automatic test system and takes the VXIbus based a test software platform which is...Virtual instrument is playing the important role in automatic test system. This paper introduces a composition of a virtual instrument automatic test system and takes the VXIbus based a test software platform which is developed by CAT lab of the UESTC as an example. Then a method to model this system based on Petri net is proposed. Through this method, we can analyze the test task scheduling to prevent the deadlock or resources conflict. At last, this paper analyzes the feasibility of this method.展开更多
To analyze the attitude errors of vertical docking test system of small satellite,the static error and kinematic error of test system are considered.The working principle of test system and coordinate of actuator are ...To analyze the attitude errors of vertical docking test system of small satellite,the static error and kinematic error of test system are considered.The working principle of test system and coordinate of actuator are introduced.The model of friction torque on the joints and torque on docking mechanism are built.Dynamics equation of actuator is built by the Lagrange equation and the Nielsen equation.Under the condition of 24 different angle groups,the calculation of dynamics equation is built by using MATLAB/SIMULINK platform and the kinematic errors of actuator are obtained.The attitude error models of docking mechanism are built.Results shows that the main angle error sources of yaw,row,pitch are not identical.The attitude error of yaw angle can be decreased by compensating the angle error around xaxis.The attitude error of row angle mainly originates in the system error,and it can be eliminated by adjusting non-orthogonal degree.展开更多
This paper adopts American National Instruments (NI) Company’s LabVIEW and LabVIEW RT virtual instrument softwareplatform and lots of things for this engine performance LabVIEW virtual instrument test system, such as...This paper adopts American National Instruments (NI) Company’s LabVIEW and LabVIEW RT virtual instrument softwareplatform and lots of things for this engine performance LabVIEW virtual instrument test system, such as the matched NI PCI dataCollection Card, NI SCXI signal-adjusting instrument and NI compact FieldPoint (cFP) distributed I/O real time system hardware.This system has realized multi performances’parallel test; and it can complete load, torsional moment, rotate speed, power, pressureand temperature’s real time monitoring automatically according to user’s setting; and finally through TCP/IP protocol it realizes testdata’s teleshare and telecontrol that user put on the test system. This system has such character as short development period, highuse efficiency and low cost, at the same time it has strong extensibility and reusability, so it has very high applied cost.展开更多
A model test system with a dynamic load device for geotechnical engineering in cold regions is presented. This system consists of a model test tank, a refrigeration device and temperature controller, a dynamic load de...A model test system with a dynamic load device for geotechnical engineering in cold regions is presented. This system consists of a model test tank, a refrigeration device and temperature controller, a dynamic load device, together with sensors and data loggers for detecting stress, deformation, and temperature changes. The system can accommodate soil blocks up to 3 m in length, 2.5 m in width, and 1 m in height. The lowest temperature provided by the refrigeration device is -20 ℃. The maximum load provided by the dynamic load device is 100 kN and the vibration fi'equency of the dynamic load can range from 0.1 to 10 Hz. A number of waveforms, such as sine waves, rectangular waves, triangle waves, and other user-defined waves can be generated by the dynamic load device controller.展开更多
In music preference experiments, housing conditions and the control of parameters for animals can affect experimental results. However, the needs of animals are indeed insufficiently considered in many reports of anim...In music preference experiments, housing conditions and the control of parameters for animals can affect experimental results. However, the needs of animals are indeed insufficiently considered in many reports of animal experiments. In order to evaluate which music rats prefer, we developed a new music preference test system. Dwelling time and visiting frequency can be recorded automatically when rats moving among different compartments of the system. We can also observe the behaviors of rats captured by a video camera. By this system, the music preference can be found, and then the related music can be used in following various studies. In this paper, we described the design of this music preference test system of rat, and some primary results were reported.展开更多
This paper presents a framework of the distributed concurrent multi-port-testing test system (CMPT-TS) for IP routers under development at Sichuan Network Communication Key Laboratory. Having analyzed the actuality of...This paper presents a framework of the distributed concurrent multi-port-testing test system (CMPT-TS) for IP routers under development at Sichuan Network Communication Key Laboratory. Having analyzed the actuality of concurrent testing for routers, this paper develops a distributed architecture of CMPT-TS and discusses its functional components in detail. Moreover, a new test definition language, CMPT definition language, is also introduced simply.展开更多
The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore ...The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore the origin of high-energy cosmic rays of the universe and to push forward the frontier of new physics.To simplify the WCDA's readout electronics,a prototype of a front-end readout for an application-specific integrated circuit(ASIC) is designed based on the timeover-threshold method to achieve charge-to-time conversion.High-precision time measurement and charge measurement are necessary over a full dynamic range[1-4000photoelectrons(P.E.)].To evaluate the performance of this ASIC,a test system is designed that includes the front-end ASIC test module,digitization module,and test software.The first module needs to be customized for different ASIC versions,whereas the digitization module and test software are tested for general-purpose use.In the digitization module,a field programmable gate array-based time-todigital converter is designed with a bin size of 333 ps,which also integrates an inter-integrated circuit to configure the ASIC test module,and a universal serial bus interface is designed to transfer data to the remote computer.Test results indicate that the time resolution is better than 0.5 ns,and the charge resolution is better than 30%root mean square(RMS) at 1 P.E.and 3%RMS at 4000 P.E.,which are beyond the application requirements.展开更多
The dynamic system control circuit board(DSCCB)is one of the most important components for dynamic system of pure electric vehicles. The current detection of the DSCCB is done manually, which is not only inefficient i...The dynamic system control circuit board(DSCCB)is one of the most important components for dynamic system of pure electric vehicles. The current detection of the DSCCB is done manually, which is not only inefficient in the detection but also difficult to guarantee the data accuracy. In order to improve the detection efficiency and accuracy, a new testing system is designed by Labview. The total test time can be further reduced by about 75% compared with the results of the manual detection. In this paper, the three-parameter sine wave curve-fit algorithm theory is applied to the phase delay detection of the current sensor sampling circuit on the DSCCB. This method solves the problem of big error in the phase delay detection.展开更多
Most detectors for nuclear physics experiments are detector arrays composed of numerous units.Testing each detector unit is a major part of the research work on detector arrays.To save time and simplify the research p...Most detectors for nuclear physics experiments are detector arrays composed of numerous units.Testing each detector unit is a major part of the research work on detector arrays.To save time and simplify the research process,a ROOT-based detector test system was designed for detector unit testing.The test system is a general pur-pose and expandable software system that can support most of the hardware devices in the market.Users can easily build a complete detector test system using the required hardware devices.The software is based on the ROOT framework and is operated on the Linux platform.The software of the test system consists of four parts:the controller,data acquisition(DAQ),high-voltage power supply,and online monitoring and analysis.In addition,a user-friendly graphical user interface(GUI)was designed for user convenience.Moreover,the online analysis func-tion of the software can implement automatic peak searching and spectrum fitting for different radioactive sources,and the results under different conditions can be shown automatically.The completion of the test system could greatly simplify the development process of the detector.展开更多
This paper presents a substructure online hybrid test system that is extensible for geographically distributed tests. This system consists of a set of devices conventionally used for cyclic tests to load the tested su...This paper presents a substructure online hybrid test system that is extensible for geographically distributed tests. This system consists of a set of devices conventionally used for cyclic tests to load the tested substructures onto the target displacement or the target force. Due to their robustness and portability, individual sets of conventional loading devices can be transported and reconfigured to realize physical loading in geographically remote laboratories. Another appealing feature is the flexible displacement-force mixed control that is particularly suitable for specimens having large disparities in stiffness during various performance stages. To conduct a substructure online hybrid test, an extensible framework is developed, which is equipped with a generalized interface to encapsulate each substructure. Multiple tested substructures and analyzed substructures using various structural program codes can be accommodated within the single framework, simply interfaced with the boundary displacements and forces. A coordinator program is developed to keep the boundaries among all substructures compatible and equilibrated. An Interuet-based data exchange scheme is also devised to transfer data among computers equipped with different software environments. A series of online hybrid tests are introduced, and the portability, flexibility, and extensibility of the online hybrid test system are demonstrated.展开更多
Objective To evaluate the endocrine disrupting effects of cadmium (Cd) using OECD enhanced TG407 test guideline. Methods Sprague-Dawley (SD) rats were randomly divided into six groups and accordingly administered ...Objective To evaluate the endocrine disrupting effects of cadmium (Cd) using OECD enhanced TG407 test guideline. Methods Sprague-Dawley (SD) rats were randomly divided into six groups and accordingly administered with 0, 1, 2.5, 5, 10, 20 mg/kg.BW/day of Cd by gavage for 28 days. Body weight, food consumption, hematology, biochemistry, sex hormone levels, urinary β2-microglobulin, organ weights and histopathology and estrous cycle were detected. Results Cd could significantly decrease animals' body weight (P〈0.05). Serum luteinizing hormone (LH) at 10-20 mg/kg.BW groups and testosterone (T) at 2.5 and 10 mg/kg.BW groups decreased significantly (P〈0.05). However, no statistically significant change was found in urinary β2-microglobulin among Cd-treatment groups (P〉0.05). Endpoints related to female reproduction including uterus weight and histopathological change at 10-20 mg/kg.BW groups showed significant increase (P〈0.05). While among male rats in 2.5, 10, 20 mg/kg.BW groups, weight of prostate, thyroids, and seminal vesicle glands significantly decreased (P〈0.05). Moreover, no histopathological change was observed in kidney. Conclusion Results suggested that Cd can cause endocrine disrupting effects in SD rats. Comparing with possible renal toxicity of Cd, its toxicity on endocrine system was more sensitive.展开更多
A more automated graphic user interface (GUI) test model, which is based on the event-flow graph, is proposed. In the model, a user interface automation API tool is first used to carry out reverse engineering for a GU...A more automated graphic user interface (GUI) test model, which is based on the event-flow graph, is proposed. In the model, a user interface automation API tool is first used to carry out reverse engineering for a GUI test sample so as to obtain the event-flow graph. Then two approaches are adopted to create GUI test sample cases. That is to say, an improved ant colony optimization (ACO) algorithm is employed to establish a sequence of testing cases in the course of the daily smoke test. The sequence goes through all object event points in the event-flow graph. On the other hand, the spanning tree obtained by deep breadth-first search (BFS) approach is utilized to obtain the testing cases from goal point to outset point in the course of the deep regression test. Finally, these cases are applied to test the new GUI. Moreover, according to the above-mentioned model, a corresponding prototype system based on Microsoft UI automation framework is developed, thus giving a more effective way to improve the GUI automation test in Windows OS.展开更多
Based on radon gas properties and its existing projects applications, we firstly attempted to apply geo- physical and chemical properties of radon gas in the field of mining engineering, and imported radioac- tive mea...Based on radon gas properties and its existing projects applications, we firstly attempted to apply geo- physical and chemical properties of radon gas in the field of mining engineering, and imported radioac- tive measurement method to detect the development process of the overlying strata mining-induced fractures and their contained water quality in underground coal mining, which not only innovates a more simple-fast-reliable detection method, but also further expands the applications of radon gas detection technology in mining field. A 3D simulation design of comprehensive testing system for detecting strata mining-induced fractures on surface with radon gas (CTSR) was carried out by using a large-scale 3D solid model design software Pro/Engineer (Pro/E), which overcame three main disadvantages of ''static design thought, 2D planar design and heavy workload for remodification design'' on exiting design for mining engineering test systems. Meanwhile, based on the simulation design results of Pro/E software, the sta- bility of the jack-screw pressure bar for the key component in CTSR was checked with a material mechan- ics theory, which provided a reliable basis for materials selection during the latter machining process.展开更多
In this paper,a novel component based framework of test system is presented for the new requirements of dynamic changes of test functions and reconfiguration of test resources.The complexity of dynamic reconfiguration...In this paper,a novel component based framework of test system is presented for the new requirements of dynamic changes of test functions and reconfiguration of test resources.The complexity of dynamic reconfiguration arises from the scale, redirection,extensibility and interconnection of components in test system.The paper is started by discussing the component assem- bly based framework which provide the open platform to the deploy of companents and then the script interpreter model is introduced to dynamically create the components and build the test system by analyzing XML based information of test system.A pipeline mod- el is presented to provide the data channels and behavior reflection among the components.Finally,a dynamic reconfigurable test system is implemented on the basis of COM and applied in the remote test and control system of CNC machine.展开更多
Fundamental power couplers are crucial components for feeding radio frequency power to accelerating cavities. Couplers must be tested and conditioned on a room-temperature test stand to evaluate and potentially improv...Fundamental power couplers are crucial components for feeding radio frequency power to accelerating cavities. Couplers must be tested and conditioned on a room-temperature test stand to evaluate and potentially improve their performance before being installed in an accelerating cavity. A new test system has been designed and is under construction at the institute of modern physics.For this test system, multiple conditioning modes, including the pulse mode, CW mode, and amplitude-sweeping mode, have been embedded in the low-level radio frequency system of the test stand. All of these conditioning modes can be run manually or automatically. In addition, a novel test cavity is proposed and has been designed, which facilitates non-contact conditioning and a multi-purpose test stand.展开更多
The temperature-Altitude Test System(TATS) supplies various testing environments.The traditional PID method controls the temperature in TATS Temperature-Pressure Cabin(TPC) over a long adjusting time and with a large ...The temperature-Altitude Test System(TATS) supplies various testing environments.The traditional PID method controls the temperature in TATS Temperature-Pressure Cabin(TPC) over a long adjusting time and with a large overshoot.In order to solve this problem simply,a temperature control strategy with temperature difference corresponding factors is presented through a dynamic analysis and modeling of TPC temperature change.The TPC temperature descending process is simulated,and the results show that this control strategy can allot the proportion of PID heating controller and PID cooling controller in the whole control process and TPC temperature can be controlled at a set point quickly and effectively.展开更多
To ensure the accuracy and precision of vibration test,a universal checking method is proposed.The use of the method is discussed and an actual example is given.First,the calibration of the 7703A-500 type sensor is an...To ensure the accuracy and precision of vibration test,a universal checking method is proposed.The use of the method is discussed and an actual example is given.First,the calibration of the 7703A-500 type sensor is analyzed on the basis of frequency response method.The frequency range of normal working can be determined by the exact calibration of sensitivity,frequency response and linearity.For the basic problem of abnormal signals appearing in test system,the method of zero check and loading vibration source are developed.The frequency spectrum of output signals is employed to distinguish the noise signal,unknown source signal and useful signal effectively.Finally,the experimental results reveal the importance to improve the accuracy of the results of practical vibration test.展开更多
基金supported by the National Natural Science Foundation of China(Nos.51927807,52074164,42277174,42077267 and 42177130)the Natural Science Foundation of Shandong Province,China(No.ZR2020JQ23)China University of Mining and Technology(Beijing)Top Innovative Talent Cultivation Fund for Doctoral Students(No.BBJ2023048)。
文摘In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses and strong disturbances and construction conditions such as the application of high prestress.It is essential to study the support components performance under dynamic-static coupling conditions.Based on this,a multi-functional anchorage support dynamic-static coupling performance test system(MAC system)is developed,which can achieve 7 types of testing functions,including single component performance,anchored net performance,anchored rock performance and so on.The bolt and cable mechanical tests are conducted by MAC system under different prestress levels.The results showed that compared to the non-prestress condition,the impact resistance performance of prestressed bolts(cables)is significantly reduced.In the prestress range of 50–160 k N,the maximum reduction rate of impact energy resisted by different types of bolts is 53.9%–61.5%compared to non-prestress condition.In the prestress range of 150–300 k N,the impact energy resisted by high-strength cable is reduced by76.8%–84.6%compared to non-prestress condition.The MAC system achieves dynamic-static coupling performance test,which provide an effective means for the design of anchorage support system.
文摘A multi-purpose prototype test system is developed to study the mechanical behavior of tunnel sup-porting structure,including a modular counterforce device,a powerful loading equipment,an advanced intelligent management system and an efficient noncontact deformation measurement system.The functions of the prototype test system are adjustable size and shape of the modular counterforce structure,sufficient load reserve and accurate loading,multi-connection linkage intelligent management,and high-precision and continuously positioned noncontact deformation measurement.The modular counterforce structure is currently the largest in the world,with an outer diameter of 20.5 m,an inner diameter of 16.5 m and a height of 6 m.The case application proves that the prototype test system can reproduce the mechanical behavior of the tunnel lining during load-bearing,deformation and failure processes in detail.
基金Supported by the Ministry of Education for Ph. D (20030614006)
文摘Virtual instrument is playing the important role in automatic test system. This paper introduces a composition of a virtual instrument automatic test system and takes the VXIbus based a test software platform which is developed by CAT lab of the UESTC as an example. Then a method to model this system based on Petri net is proposed. Through this method, we can analyze the test task scheduling to prevent the deadlock or resources conflict. At last, this paper analyzes the feasibility of this method.
基金supported by National Natural Science Foundation of China(No.51375125)the Foundation for Distinguished Young Scholars of Heilongjiang Province,China(No.JC201111)the Program for New Century Excellent Talents in University(No.NCET10-0146)
文摘To analyze the attitude errors of vertical docking test system of small satellite,the static error and kinematic error of test system are considered.The working principle of test system and coordinate of actuator are introduced.The model of friction torque on the joints and torque on docking mechanism are built.Dynamics equation of actuator is built by the Lagrange equation and the Nielsen equation.Under the condition of 24 different angle groups,the calculation of dynamics equation is built by using MATLAB/SIMULINK platform and the kinematic errors of actuator are obtained.The attitude error models of docking mechanism are built.Results shows that the main angle error sources of yaw,row,pitch are not identical.The attitude error of yaw angle can be decreased by compensating the angle error around xaxis.The attitude error of row angle mainly originates in the system error,and it can be eliminated by adjusting non-orthogonal degree.
文摘This paper adopts American National Instruments (NI) Company’s LabVIEW and LabVIEW RT virtual instrument softwareplatform and lots of things for this engine performance LabVIEW virtual instrument test system, such as the matched NI PCI dataCollection Card, NI SCXI signal-adjusting instrument and NI compact FieldPoint (cFP) distributed I/O real time system hardware.This system has realized multi performances’parallel test; and it can complete load, torsional moment, rotate speed, power, pressureand temperature’s real time monitoring automatically according to user’s setting; and finally through TCP/IP protocol it realizes testdata’s teleshare and telecontrol that user put on the test system. This system has such character as short development period, highuse efficiency and low cost, at the same time it has strong extensibility and reusability, so it has very high applied cost.
基金supported by the National Natural Science Foundation of China (No. 40971046,41023003,40901039)the Project from the State Key Laboratory of Frozen Soil Engineering of China (No. 09SF102003)
文摘A model test system with a dynamic load device for geotechnical engineering in cold regions is presented. This system consists of a model test tank, a refrigeration device and temperature controller, a dynamic load device, together with sensors and data loggers for detecting stress, deformation, and temperature changes. The system can accommodate soil blocks up to 3 m in length, 2.5 m in width, and 1 m in height. The lowest temperature provided by the refrigeration device is -20 ℃. The maximum load provided by the dynamic load device is 100 kN and the vibration fi'equency of the dynamic load can range from 0.1 to 10 Hz. A number of waveforms, such as sine waves, rectangular waves, triangle waves, and other user-defined waves can be generated by the dynamic load device controller.
基金supported by the National Natural Science Foundation of China under Grant No. 60736029, 30525030, 30570474, 30870655the 973 project under Grant No. 2006CB504501.
文摘In music preference experiments, housing conditions and the control of parameters for animals can affect experimental results. However, the needs of animals are indeed insufficiently considered in many reports of animal experiments. In order to evaluate which music rats prefer, we developed a new music preference test system. Dwelling time and visiting frequency can be recorded automatically when rats moving among different compartments of the system. We can also observe the behaviors of rats captured by a video camera. By this system, the music preference can be found, and then the related music can be used in following various studies. In this paper, we described the design of this music preference test system of rat, and some primary results were reported.
文摘This paper presents a framework of the distributed concurrent multi-port-testing test system (CMPT-TS) for IP routers under development at Sichuan Network Communication Key Laboratory. Having analyzed the actuality of concurrent testing for routers, this paper develops a distributed architecture of CMPT-TS and discusses its functional components in detail. Moreover, a new test definition language, CMPT definition language, is also introduced simply.
基金supported by the Knowledge Innovation Program of the Chinese Academy of Sciences(KJCX2-YW-N27)the CAS Center for Excellence in Particle Physics(CCEPP)
文摘The water Cherenkov detector array(WCDA) is an important part of the large high-altitude air shower observatory(LHAASO),which is in a research and development phase.The central scientific goal of LHAASO is to explore the origin of high-energy cosmic rays of the universe and to push forward the frontier of new physics.To simplify the WCDA's readout electronics,a prototype of a front-end readout for an application-specific integrated circuit(ASIC) is designed based on the timeover-threshold method to achieve charge-to-time conversion.High-precision time measurement and charge measurement are necessary over a full dynamic range[1-4000photoelectrons(P.E.)].To evaluate the performance of this ASIC,a test system is designed that includes the front-end ASIC test module,digitization module,and test software.The first module needs to be customized for different ASIC versions,whereas the digitization module and test software are tested for general-purpose use.In the digitization module,a field programmable gate array-based time-todigital converter is designed with a bin size of 333 ps,which also integrates an inter-integrated circuit to configure the ASIC test module,and a universal serial bus interface is designed to transfer data to the remote computer.Test results indicate that the time resolution is better than 0.5 ns,and the charge resolution is better than 30%root mean square(RMS) at 1 P.E.and 3%RMS at 4000 P.E.,which are beyond the application requirements.
基金"863"program-saving and new energy vehicles of major projects funded project(2008AA11A154)
文摘The dynamic system control circuit board(DSCCB)is one of the most important components for dynamic system of pure electric vehicles. The current detection of the DSCCB is done manually, which is not only inefficient in the detection but also difficult to guarantee the data accuracy. In order to improve the detection efficiency and accuracy, a new testing system is designed by Labview. The total test time can be further reduced by about 75% compared with the results of the manual detection. In this paper, the three-parameter sine wave curve-fit algorithm theory is applied to the phase delay detection of the current sensor sampling circuit on the DSCCB. This method solves the problem of big error in the phase delay detection.
基金This work was supported by the National Natural Science Foundation of China(No.U1732142).
文摘Most detectors for nuclear physics experiments are detector arrays composed of numerous units.Testing each detector unit is a major part of the research work on detector arrays.To save time and simplify the research process,a ROOT-based detector test system was designed for detector unit testing.The test system is a general pur-pose and expandable software system that can support most of the hardware devices in the market.Users can easily build a complete detector test system using the required hardware devices.The software is based on the ROOT framework and is operated on the Linux platform.The software of the test system consists of four parts:the controller,data acquisition(DAQ),high-voltage power supply,and online monitoring and analysis.In addition,a user-friendly graphical user interface(GUI)was designed for user convenience.Moreover,the online analysis func-tion of the software can implement automatic peak searching and spectrum fitting for different radioactive sources,and the results under different conditions can be shown automatically.The completion of the test system could greatly simplify the development process of the detector.
基金Public Benefit Research Foundation under Grant No.201108006Natural Science Foundation under Grant No.51161120360+2 种基金Heilongjiang Overseas Funding under Grant No.LC201002 of ChinaGrant-in-Aid for Scientific Research(Basic Research Category A,19206060)Japan Society for the Promotion of Science
文摘This paper presents a substructure online hybrid test system that is extensible for geographically distributed tests. This system consists of a set of devices conventionally used for cyclic tests to load the tested substructures onto the target displacement or the target force. Due to their robustness and portability, individual sets of conventional loading devices can be transported and reconfigured to realize physical loading in geographically remote laboratories. Another appealing feature is the flexible displacement-force mixed control that is particularly suitable for specimens having large disparities in stiffness during various performance stages. To conduct a substructure online hybrid test, an extensible framework is developed, which is equipped with a generalized interface to encapsulate each substructure. Multiple tested substructures and analyzed substructures using various structural program codes can be accommodated within the single framework, simply interfaced with the boundary displacements and forces. A coordinator program is developed to keep the boundaries among all substructures compatible and equilibrated. An Interuet-based data exchange scheme is also devised to transfer data among computers equipped with different software environments. A series of online hybrid tests are introduced, and the portability, flexibility, and extensibility of the online hybrid test system are demonstrated.
基金supported by the National Natural Science Foundation of China(Grant No 81273081)
文摘Objective To evaluate the endocrine disrupting effects of cadmium (Cd) using OECD enhanced TG407 test guideline. Methods Sprague-Dawley (SD) rats were randomly divided into six groups and accordingly administered with 0, 1, 2.5, 5, 10, 20 mg/kg.BW/day of Cd by gavage for 28 days. Body weight, food consumption, hematology, biochemistry, sex hormone levels, urinary β2-microglobulin, organ weights and histopathology and estrous cycle were detected. Results Cd could significantly decrease animals' body weight (P〈0.05). Serum luteinizing hormone (LH) at 10-20 mg/kg.BW groups and testosterone (T) at 2.5 and 10 mg/kg.BW groups decreased significantly (P〈0.05). However, no statistically significant change was found in urinary β2-microglobulin among Cd-treatment groups (P〉0.05). Endpoints related to female reproduction including uterus weight and histopathological change at 10-20 mg/kg.BW groups showed significant increase (P〈0.05). While among male rats in 2.5, 10, 20 mg/kg.BW groups, weight of prostate, thyroids, and seminal vesicle glands significantly decreased (P〈0.05). Moreover, no histopathological change was observed in kidney. Conclusion Results suggested that Cd can cause endocrine disrupting effects in SD rats. Comparing with possible renal toxicity of Cd, its toxicity on endocrine system was more sensitive.
文摘A more automated graphic user interface (GUI) test model, which is based on the event-flow graph, is proposed. In the model, a user interface automation API tool is first used to carry out reverse engineering for a GUI test sample so as to obtain the event-flow graph. Then two approaches are adopted to create GUI test sample cases. That is to say, an improved ant colony optimization (ACO) algorithm is employed to establish a sequence of testing cases in the course of the daily smoke test. The sequence goes through all object event points in the event-flow graph. On the other hand, the spanning tree obtained by deep breadth-first search (BFS) approach is utilized to obtain the testing cases from goal point to outset point in the course of the deep regression test. Finally, these cases are applied to test the new GUI. Moreover, according to the above-mentioned model, a corresponding prototype system based on Microsoft UI automation framework is developed, thus giving a more effective way to improve the GUI automation test in Windows OS.
基金support for this work provided by the Fundamental Research Funds for the Central Universities(China University of Mining & Technology) (No. 2010ZDP02B02)the State Key Laboratory of Coal Resources and Safe Mining(No. SKLCRSM08X02)
文摘Based on radon gas properties and its existing projects applications, we firstly attempted to apply geo- physical and chemical properties of radon gas in the field of mining engineering, and imported radioac- tive measurement method to detect the development process of the overlying strata mining-induced fractures and their contained water quality in underground coal mining, which not only innovates a more simple-fast-reliable detection method, but also further expands the applications of radon gas detection technology in mining field. A 3D simulation design of comprehensive testing system for detecting strata mining-induced fractures on surface with radon gas (CTSR) was carried out by using a large-scale 3D solid model design software Pro/Engineer (Pro/E), which overcame three main disadvantages of ''static design thought, 2D planar design and heavy workload for remodification design'' on exiting design for mining engineering test systems. Meanwhile, based on the simulation design results of Pro/E software, the sta- bility of the jack-screw pressure bar for the key component in CTSR was checked with a material mechan- ics theory, which provided a reliable basis for materials selection during the latter machining process.
基金Supported by the National Science Foundation of China(Grant No.50275061)the National High Technology Research and Development Program(Grant No.2001AA423230).
文摘In this paper,a novel component based framework of test system is presented for the new requirements of dynamic changes of test functions and reconfiguration of test resources.The complexity of dynamic reconfiguration arises from the scale, redirection,extensibility and interconnection of components in test system.The paper is started by discussing the component assem- bly based framework which provide the open platform to the deploy of companents and then the script interpreter model is introduced to dynamically create the components and build the test system by analyzing XML based information of test system.A pipeline mod- el is presented to provide the data channels and behavior reflection among the components.Finally,a dynamic reconfigurable test system is implemented on the basis of COM and applied in the remote test and control system of CNC machine.
基金supported by the National Key Basic Research Program of China(973 Program)(No.2014CB845504)
文摘Fundamental power couplers are crucial components for feeding radio frequency power to accelerating cavities. Couplers must be tested and conditioned on a room-temperature test stand to evaluate and potentially improve their performance before being installed in an accelerating cavity. A new test system has been designed and is under construction at the institute of modern physics.For this test system, multiple conditioning modes, including the pulse mode, CW mode, and amplitude-sweeping mode, have been embedded in the low-level radio frequency system of the test stand. All of these conditioning modes can be run manually or automatically. In addition, a novel test cavity is proposed and has been designed, which facilitates non-contact conditioning and a multi-purpose test stand.
文摘The temperature-Altitude Test System(TATS) supplies various testing environments.The traditional PID method controls the temperature in TATS Temperature-Pressure Cabin(TPC) over a long adjusting time and with a large overshoot.In order to solve this problem simply,a temperature control strategy with temperature difference corresponding factors is presented through a dynamic analysis and modeling of TPC temperature change.The TPC temperature descending process is simulated,and the results show that this control strategy can allot the proportion of PID heating controller and PID cooling controller in the whole control process and TPC temperature can be controlled at a set point quickly and effectively.
基金Shan Dong Scientific Research Foundation for Excellent Young Scientists(Grant No:BS2011ZZ001)National Natural Science Foundation of China(Grant No.51105172)
文摘To ensure the accuracy and precision of vibration test,a universal checking method is proposed.The use of the method is discussed and an actual example is given.First,the calibration of the 7703A-500 type sensor is analyzed on the basis of frequency response method.The frequency range of normal working can be determined by the exact calibration of sensitivity,frequency response and linearity.For the basic problem of abnormal signals appearing in test system,the method of zero check and loading vibration source are developed.The frequency spectrum of output signals is employed to distinguish the noise signal,unknown source signal and useful signal effectively.Finally,the experimental results reveal the importance to improve the accuracy of the results of practical vibration test.