Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients w...Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients with different CTDs were recruited and underwent lung HRCT and PFT. Eerythrocyte sedimentation rate (ESR), C-reactive protein (CRP), serum ferritin (SF), anti-SSA, and so on were tested. Based on HRCT, a patient was classified into ILD group (CTD+ILD) or non-ILD group (CTD-ILD). HRCT, PFT, and laboratory markers were compared according to CTDs and CTD-associated ILDs. Results. The incidences of ILD were 79.6%, 82.0%, 89.7%, and 97.1% respectively for Rheumatoid arthritis (RA), primary Sjogren’s symptom (pSS), dermatomyositis/polymyositis (DM/PM), and systemic sclerosis (SSc) groups. RA and pSS patients exhibited more nodules, patching, ground-glass opacity, and cord shadow foci in HRCT, DM/PM and SSc patients exhibited more reticular opacity and honeycombing foci. RA and pSS patients exhibited more obstructive ventilatory disorder, small airway dysfunction and emphysema in PFT, and DM/PM and SSc patients exhibited more restrictive ventilatory disorder, mixed ventilatory disorder. ESR, CRP and SF were significantly higher in total CTD+ILD group than in total CTD-ILD group (P = 0.047, 0.006, 0.004, respectively), and higher in different CTD+ ILD groups than in comparable CTD-ILD groups (P = 0.049, 0.048, and 0.023, pSS+ILD, SSc+ILD and RA+ILD compared to pSS-ILD, SSc-ILD and RA-ILD, respectively for ESR, CRP, SF). The positive rate of anti-SSA was significantly higher in DM/PM+ILD group than in DM/PM-ILD group (P = 0.025). Conclusions. The manifestations and incidences of ILDs differ among different CTDs in HRCT and PFT, and inflammation and anti-SSA are positively correlated with ILDs in different CTDs, which provide important evidences for judging disease condition and prognosis.展开更多
AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively id...AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively identified 52 consecutive adult patients with hPIDs who underwent 64-row HRCT and PFTs at the time of diagnosis. On a per-patient basis, an experienced radiologist recorded airway abnormalities(bronchiectasis,airway wall thickening, mucus plugging, tree-in-bud, and air-trapping) and parenchymal-interstitial abnormalities(consolidations, ground-glass opacities,linear and/or irregular opacities, nodules, and bullae/cysts) found on HRCT.The chi-square test was performed to compare the prevalence of each abnormality among patients with different subtypes of hPIDs. Overall logistic regression analysis was performed to assess whether HRCT findings predicted obstructive and/or restrictive PFTs results(absent-to-mild vs moderate-tosevere).RESULTS Thirty-eight of the 52 patients with hPIDs showed common variable immunodeficiency disorders(CVID), while the remaining 14 had CVID-like conditions(i.e., 11 had isolated IgG subclass deficiencies and 3 had selective IgA deficiencies). The prevalence of most HRCT abnormalities was not significantly different between CVID and CVID-like patients(P > 0.05), except for linear and/or irregular opacities(prevalence of 31.6% in the CVID group and 0 in the CVID-like group; P = 0.0427). Airway wall thickening was the most frequent HRCT abnormality found in both CVID and CVID-like patients(71% of cases in both groups). The presence of tree-in-bud abnormalities was an independent predictor of moderate-to-severe obstructive defects at PFTs(Odds Ratio, OR, of 18.75, P < 0.05), while the presence of linear and/or irregular opacities was an independent predictor of restrictive defects at PFTs(OR = 13.00; P < 0.05).CONCLUSION CVID and CVID-like patients showed similar HRCT findings. Tree-in-bud and linear and/or irregular opacities predicted higher risks of, respectively,obstructive and restrictive defects at PFTs.展开更多
Objective: The aim of this preliminary study was to evaluate the feasibility of exercise testing (ET) for predicting postoperative complications in patients with impaired pulmonary function. Methods: Thirteen patients...Objective: The aim of this preliminary study was to evaluate the feasibility of exercise testing (ET) for predicting postoperative complications in patients with impaired pulmonary function. Methods: Thirteen patients were prospectively enrolled. The enrollment criteria were FEV1.0% 8 by the Goddard classification or interstitial pneumonia on chest computed tomography. Patients underwent testing for pulmonary function, six-minute walking test (6MWT), and stair-climbing test (SCT). Postoperative cardiopulmonary complications (PCPCs) were recorded. Results: Four patients developed PCPCs. There were no significant differences between the patients with PCPCs (n = 4) and those without PCPCs (n = 9) for background data and PFT. The distances achieved in the 6MWT were 503 ± 72.7 m for patients without PCPCs and 369 ± 50.7 m for patients with PCPCs (p = 0.011). The SCT climbing heights were 20.4 ± 5.3 m for patients without PCPCs and 14.9 ± 4.0 m for patients with PCPCs (P = 0.187). Cut-off points, including a 6MFT distance of less than 400 m, SCT height lower than 15 m, and SCT climbing speed less than 8.5 m/min, were predictive of CPCP. Conclusions: Exercise testing is more feasible for predicting postoperative cardiopulmonary complications than stationary pulmonary function testing.展开更多
We retrospectively assessed long-term pulmonary function in adults surviving for ≥5 years after myeloablative allogeneic hematopoietic stem cell transplantation and identified risk factors for late-onset noninfectiou...We retrospectively assessed long-term pulmonary function in adults surviving for ≥5 years after myeloablative allogeneic hematopoietic stem cell transplantation and identified risk factors for late-onset noninfectious pulmonary complications. Among 174 patients undergoing transplantation for hematologic malignancies between May 1994 and December 2004, 81 long-term survivors were evaluated. Pulmonary function tests (PFTs) were performed before conditioning, 3 months and 1 year after transplantation, and then annually. Eight patients (10%) had abnormal pulmonary function before transplantation, but this was not associated with late changes in PFTs. Patients with chronic graft-versus-host disease (GVHD) showed a significant decline of lung function after 3 years when compared with patients without chronic GVHD. Abnormal pretransplantation lung function was associated with pulmonary chronic GVHD according to National Institutes of Health criteria (score 0, n = 58;score 1, n = 14;score 2, n = 6;score 3, n = 3). Five patients with late-onset noninfectious pulmonary complications showed a decline of lung function at 1 year after transplantation. Only chronic GVHD was significantly related to late-onset noninfectious pulmonary complications. In conclusion, abnormal lung function before transplantation may be associated with a decline in pulmonary function within 1 year after transplantation, but late-onset noninfectious pulmonary complications could not be predicted from pretransplantation lung function.展开更多
Workers involved in hydraulic fracking processes are exposed to various types of chemicals and dusts in their workplaces, such as proppants, which hold open the fissures created in the fracking process. Recently, cera...Workers involved in hydraulic fracking processes are exposed to various types of chemicals and dusts in their workplaces, such as proppants, which hold open the fissures created in the fracking process. Recently, ceramic proppants have been developed that may be less hazardous to workers than traditional proppants. Pulmonary function testing of workers producing ceramic proppant was used to assess the potential inhalation hazards of ceramic proppant. 100 male workers from a producer of ceramic proppant were evaluated with pulmonary function test data collected and evaluated using The American Thoracic Society (ATS) acceptability criteria. A comparison group was selected from the Third National Health and Nutrition Examination Survey (NHANES III) spirometry laboratory subset. No pulmonary function deficits were found in the worker group in comparison to the NHANES III population. Mean FEV1 and FVC values in workers were 3.8 and 4.8 liters respectively, and were greater as compared to the NHANES III population of similar demographics. An FEV1/FVC ratio of less than 0.8, when compared to the NHANES III group, produced an odds ratio of 0.44 in worker group, indicating less risk of preclinical pulmonary dysfunction. Overall, exposure to ceramic proppant was not found to produce an adverse impact on pulmonary function in workers engaged in the manufacture of ceramic proppant.展开更多
Breathing is considered the common factor that links studying,sleeping,and activities.It is one of the primary indicators that is frequently considered when determining whether or not an unconscious individual is stil...Breathing is considered the common factor that links studying,sleeping,and activities.It is one of the primary indicators that is frequently considered when determining whether or not an unconscious individual is still alive.The evolution and development process of the respiratory system that occurs in a foetus is primarily from head to tail(cephalocaudal).Many changes occur throughout this period until the 28th week of pregnancy at which the foetus^respiratory system will attain adequate development for the rest of his or her life.The respiratory system comprises of the lungs and the encompassing thoracic wall,which includes the thoracic cages,midriff(diaphragm),and the abdominal wall.Spirometry is a procedure used for estimating air volumes that enter and exit the pulmonary system with the aid of a spirometer.The various pulmonary parameters that reflect pulmonary ventilation are of great significance in diagnosing respiratory diseases.The respiratory system will be discussed in more detail in this article.展开更多
After stroke,even high-functioning individuals may experience compromised bimanual coordination and fine motor dexterity,leading to reduced functional independence.Bilateral arm training has been proposed as a promisi...After stroke,even high-functioning individuals may experience compromised bimanual coordination and fine motor dexterity,leading to reduced functional independence.Bilateral arm training has been proposed as a promising intervention to address these deficits.However,the neural basis of the impairment of functional fine motor skills and their relationship to bimanual coordination performance in stroke patients remains unclear,limiting the development of more targeted interventions.To address this gap,our study employed functional near-infrared spectroscopy to investigate cortical responses in patients after stroke as they perform functional tasks that engage fine motor control and coordination.Twenty-four high-functioning patients with ischemic stroke(7 women,17 men;mean age 64.75±10.84 years)participated in this cross-sectional observational study and completed four subtasks from the Purdue Pegboard Test,which measures unimanual and bimanual finger and hand dexterity.We found significant bilateral activation of the sensorimotor cortices during all Purdue Pegboard Test subtasks,with bimanual tasks inducing higher cortical activation than the assembly subtask.Importantly,patients with better bimanual coordination exhibited lower cortical activation during the other three Purdue Pegboard Test subtasks.Notably,the observed neural response patterns varied depending on the specific subtask.In the unaffected hand task,the differences were primarily observed in the ipsilesional hemisphere.In contrast,the bilateral sensorimotor cortices and the contralesional hemisphere played a more prominent role in the bimanual task and assembly task,respectively.While significant correlations were found between cortical activation and unimanual tasks,no significant correlations were observed with bimanual tasks.This study provides insights into the neural basis of bimanual coordination and fine motor skills in high-functioning patients after stroke,highlighting task-dependent neural responses.The findings also suggest that patients who exhibit better bimanual performance demonstrate more efficient cortical activation.Therefore,incorporating bilateral arm training in post-stroke rehabilitation is important for better outcomes.The combination of functional near-infrared spectroscopy with functional motor paradigms is valuable for assessing skills and developing targeted interventions in stroke rehabilitation.展开更多
AIM:To investigate pulmonary involvement via pulmonary function tests (PFT) and high-resolution computed tomography (HRCT) in patients with chronic hepatitis C virus (HCV) infection.METHODS:Thirty-four patients with c...AIM:To investigate pulmonary involvement via pulmonary function tests (PFT) and high-resolution computed tomography (HRCT) in patients with chronic hepatitis C virus (HCV) infection.METHODS:Thirty-four patients with chronic HCV infection without diagnosis of any pulmonary diseases and 10 healthy cases were enrolled in the study. PFT and HRCT were performed in all cases.RESULTS:A decrease lower than 80% of the predicted value was detected in vital capacity in 9/34 patients, in forced expiratory volume in one second in 8/34 palJents, and in forced expiratory flow 25-75 in 15/34 patients, respectively. Carbon monoxide diffusing capacity (DLCO) was decreased in 26/34 patients. Findings of interstitial pulmonary involvement were detected in bhe HRCT of 16/34 patients. Significant difference was found between controls and patients with HCV infection in findings of HRCT (X^2=4.7, P=0.003). Knodell histological activity index (KHAI) of 28/34 patients in whom liver biopsy was applied was 9.0±4.7. HRCT findings, PFT values and DLCO were not affected by KHAI in patients with HCV infection. In these patients, all the parameters were related with age.CONCLUSION: We suggest that chronic hepatitis C virus infection may cause pulmonary interstitial involvement without evident respiratory symptoms.展开更多
Introduction: The Six-Minute Walk Test (6MWT) is an inexpensive method to objectively evaluate physical capacity or limitation and stratify prognosis in patients with Heart Failure (HF). Since the clinical p...Introduction: The Six-Minute Walk Test (6MWT) is an inexpensive method to objectively evaluate physical capacity or limitation and stratify prognosis in patients with Heart Failure (HF). Since the clinical perception of symptoms may be adapted or compromised, regular evaluation from medical interviews often fails to determine functional classification. This study aimed to assess the correlation between New York Heart Association Functional Class (NYHA-FC) and the distance walked in the 6MWT. Methods: We conducted a cross-sectional observational study that included patients with HF with reduced ejection fraction followed up at an outpatient service of a teaching hospital, from August 2018 to April 2019. Patients in NYHA-FC I, II, or III were included. We compared NYHA-FC subjectively obtained during the consultation with the 6MWT performed after medical consultation, and the correlation between these two parameters was assessed. Results: The study included 70 patients with HF, 41 (58.6%) of whom were female. The mean age was 61.2 ± 12.7 years. The most prevalent etiologies were dilated idiopathic cardiomyopathy (35.7%) followed by ischemic cardiomyopathy (25.7%). The mean ejection fraction was 34.1% ± 9.8%. The average distance walked in the 6MWT by NYHA-FC I patients was 437.8 ± 95.8 meters, NYHA-FC II 360.1 ± 96.4, and NYHA-FC III 248.4 ± 98.3. Functional class measured by the 6MWT was different than that estimated by NYHA-FC in 34 patients (48.6%), 23 (32.9%) for a higher functional class and 11 (15.7%) for a lower one (p = 0.07). Pearson’s correlation coefficient between NYHA-FC and the 6MWT was -0.55. Conclusion: There was a moderate correlation between the subjective NYHA-FC and the 6MWT. The 6MWT revealed a different classification from NYHA-FC in almost half of the patients. Among those who presented discrepancies between methods, 6MWT reclassification towards a higher functional class was more common.展开更多
Background: Chronic heart failure is a public health problem worldwide. It has a high mortality rate and is accompanied by a decreased functional capacity and alteration of the quality of life. Objective: This st...Background: Chronic heart failure is a public health problem worldwide. It has a high mortality rate and is accompanied by a decreased functional capacity and alteration of the quality of life. Objective: This study aimed to assess the cardiovascular functional capacity of a group of patients suffering from heart failure using the 6-minute walk test (6 MWT). Methods: This was a cross-sectional study carried out in the cardiology unit of Douala’s general hospital for 4 months. We included all eligible patients aged 18 years or more who had stable chronic heart failure and gave informed consent. Those who had an acute coronary syndrome (≤1 month), tachycardia (HR ≥ 120 bpm), high blood pressure (SBP ≥ 180 mmHg and/or DBP ≥ 100 mmHg) and reduced mobility due to orthopaedic reasons were excluded. A 6 MWT was done according to the American Thoracic Society guidelines. The 6 MWT result was considered poor for - 450 m and good for >450 m. Results: We recruited a total of 81 patients (61.7% women) with a mean age of 65.9 ± 10.6 years. The most frequent risk factor for heart failure was high blood pressure (77.8%), alcohol consumption(69.1%) and a sedentary lifestyle (53.1%). The left ventricular ejection fraction was mostly preserved (42.0%) or mildly altered (46.9). The 6 MWT results were poor in 55.6% of cases, average in 19.8% of cases and good in only 24.7% of cases. More than half (59.3%) of the participants perceived the effort as being difficult. The cardiovascular functional capacity was significantly associated with age, heart failure stage and physical activity (p Conclusion: Most patients suffering from chronic stable heart failure in the general hospital of Douala have poor cardiovascular functional capacity.展开更多
The objective of this research was to determine the mechanical parameter from EVA foam and also investigate its behavior by using Blatz-Ko,Neo-Hookean,Mooney model and experimental test.The physical characteristic of ...The objective of this research was to determine the mechanical parameter from EVA foam and also investigate its behavior by using Blatz-Ko,Neo-Hookean,Mooney model and experimental test.The physical characteristic of EVA foam was also evaluated by scanning electron microscopy(SEM).The results show that Blatz-Ko and Neo-Hookean model can fit the curve at 5%and 8%strain,respectively.The Mooney model can fit the curve at 50%strain.The modulus of rigidity evaluated from Mooney model is 0.0814±0.0027 MPa.The structure of EVA foam from SEM image shows that EVA structure is a closed cell with homogeneous porous structure.From the result,it is found that Mooney model can adjust the data better than other models.This model can be applied for mechanical response prediction of EVA foam and also for reference value in engineering application.展开更多
BACKGROUND Lung cancer is a malignant tumor with high morbidity and mortality among cancers.Surgery is currently one of the primary methods of treating lung cancer.Although it can slow down the progression of the dise...BACKGROUND Lung cancer is a malignant tumor with high morbidity and mortality among cancers.Surgery is currently one of the primary methods of treating lung cancer.Although it can slow down the progression of the disease by removing the lesion,this invasive surgery inevitably damages the integrity of the patient’s chest.Moreover,the patient’s pulmonary function may have a low compensatory capacity after surgery,causing various respiratory diseases such as atelectasis,respiratory function decline,and even serious cardiovascular disease.All of these have great negative impacts on the surgical effect and the prognosis of patients.With the continuous exploration and development of nursing,continuous nursing and respiratory exercise nursing have been gradually applied in the nursing of patients after lung cancer surgery,and have achieved good nursing results.AIM To investigate the effect of continuous nursing combined with respiratory exercise nursing on the pulmonary function of postoperative patients with lung cancer.METHODS A total of 80 patients with lung cancer who underwent surgery in our hospital from January 2021 to December 2021 were selected as the study subjects.All subjects were randomly divided into the control group(n=40 cases)and the experimental group(n=40 cases).Patients with lung cancer in the control group were given conventional nursing after surgery,while the experimental group was given continuous nursing combined with respiratory exercise nursing based on conventional nursing.The recovery of pulmonary function and respiratory symptoms was observed before and after 3 mo of intervention in both groups.The pulmonary function parameters,blood gas analysis,MD Anderson Symptom Inventory-lung cancer module(MDASI-LC)scores,incidence of pulmonary complications,and Morisky compliance scores were compared between the two groups before and after 3 mo of intervention.RESULTS There was no significant difference in pulmonary function and blood gas analysis between the two groups before intervention(P>0.05).3 mo after the intervention,the pulmonary function parameters in the experimental group(SpO2,VC,MVV,FEV1,FEV1%pred,and FEV1/FVC)were higher than those in the control group,and the differences were statistically significant(P<0.05).There was no significant difference in blood gas analysis between the two groups before intervention(P>0.05).PaO2 in the experimental group was significantly higher than that in the control group,and PaCO_(2) was significantly lower than that in the control group 3 mo after the intervention.The difference had statistical significance(P<0.05).3 mo after the intervention,the MDASI score of respiratory symptoms in the experimental group was significantly lower than that in the control group(P<0.05),and the incidence of pulmonary complications was lower than that in the control group(P<0.05).In addition,the treatment compliance and nursing satisfaction of patients in the experimental group were higher than those in the control group,and the differences were statistically significant(P<0.05).CONCLUSION Continuous nursing combined with respiratory exercise nursing can significantly accelerate the recovery of respiratory function in postoperative lung cancer patients,reduce the incidence of postoperative complications of lung cancer as well as improve the treatment compliance of patients.展开更多
BACKGROUND While colorectal polyps are not cancerous,some types of polyps,known as adenomas,can develop into colorectal cancer over time.Polyps can often be found and removed by colonoscopy;however,this is an invasive...BACKGROUND While colorectal polyps are not cancerous,some types of polyps,known as adenomas,can develop into colorectal cancer over time.Polyps can often be found and removed by colonoscopy;however,this is an invasive and expensive test.Thus,there is a need for new methods of screening patients at high risk of developing polyps.AIM To identify a potential association between colorectal polyps and small intestine bacteria overgrowth(SIBO)or other relevant factors in a patient cohort with lactulose breath test(LBT)results.METHODS A total of 382 patients who had received an LBT were classified into polyp and non-polyp groups that were confirmed by colonoscopy and pathology.SIBO was diagnosed by measuring LBTderived hydrogen(H)and methane(M)levels according to 2017 North American Consensus recommendations.Logistic regression was used to assess the ability of LBT to predict colorectal polyps.Intestinal barrier function damage(IBFD)was determined by blood assays.RESULTS H and M levels revealed that the prevalence of SIBO was significantly higher in the polyp group than in the non-polyp group(41%vs 23%,P<0.01;71%vs 59%,P<0.05,respectively).Within 90 min of lactulose ingestion,the peak H values in the adenomatous and inflammatory/hyperplastic polyp patients were significantly higher than those in the non-polyp group(P<0.01,and P=0.03,respectively).In 227 patients with SIBO defined by combining H and M values,the rate of IBFD determined by blood lipopolysaccharide levels was significantly higher among patients with polyps than those without(15%vs 5%,P<0.05).In regression analysis with age and gender adjustment,colorectal polyps were most accurately predicted with models using M peak values or combined H and M values limited by North American Consensus recommendations for SIBO.These models had a sensitivity of≥0.67,a specificity of≥0.64,and an accuracy of≥0.66.CONCLUSION The current study made key associations among colorectal polyps,SIBO,and IBFD and demonstrated that LBT has moderate potential as an alternative noninvasive screening tool for colorectal polyps.展开更多
[Objectives] To investigate the effects of TCM nursing based on syndrome differentiation on pulmonary function and quality of life in patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD)....[Objectives] To investigate the effects of TCM nursing based on syndrome differentiation on pulmonary function and quality of life in patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). [Methods] A total of 92 patients with AECOPD who came to Nanchong Chinese Medicine Hospital from March 2022 to February 2023 were selected for the study, and the intervention group (TCM nursing based on syndrome differentiation, 46 cases) and the conventional group (basic nursing, 46 cases) were selected for the study, and the pulmonary function and quality of life of the two groups were compared. [Results] Before nursing, there was no significant difference in levels of forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and percentage of forced expiratory volume in one second to forced vital capacity (FEV1/FVC) between the intervention group and conventional group ( P >0.05). After 3 months of nursing, the levels of FVC, FEV1 and FEV1/FVC in the intervention group were higher than those in the conventional group ( P <0.05). Before nursing, there was no significant difference in the scores of health, emotion and social functions between the two groups ( P >0.05). At three months of nursing, the scores of health, emotion, and social functions in the intervention group were higher than those in the conventional group ( P <0.05). [Conclusions] The implementation of TCM nursing based on syndrome differentiation in patients with AECOPD can effectively improve the pulmonary function and quality of life of patients, and has significant clinical implementation value.展开更多
Objective:To analyze the effect of combined inhalation of budesonide formoterol and tiotropium bromide on arterial blood gas and pulmonary function indexes in patients with chronic obstructive pulmonary disease(COPD)....Objective:To analyze the effect of combined inhalation of budesonide formoterol and tiotropium bromide on arterial blood gas and pulmonary function indexes in patients with chronic obstructive pulmonary disease(COPD).Methods:100 patients with COPD treated from January to December 2022 were selected as observation objects,and were divided into a control group(n=50,in which budesonide and formoterol were administered)and an experimental group(n=50,the treatment drug was budesonide formoterol combined with tiotropium bromide)according to the computer grouping method,and compared the treatment results.Results:(i)Before treatment,there was no difference in the partial pressure of carbon dioxide and partial pressure of oxygen between the control group and the experimental group(P>0.05);after treatment,the partial pressure of carbon dioxide and partial pressure of oxygen in the experimental group were higher than those in the control group,with significant differences(P<0.05).(ii)Before treatment,there was no difference in forced vital capacity(FVC),forced expiratory volume in one second(FEV1),FEV1/FVC between the control group and the experimental group(P>0.05);after treatment,the FVC,FEV1,and FEV1/FVC in the experimental group were significantly higher than those in the control group(P<0.05).(iii)There was no difference in the levels of CRP,IL-6,and TNF-αbetween the control group and the experimental group(P>0.05);after treatment,the levels of CRP,IL-6,and TNF-αin the experimental group were lower than those in the control group,with significant differences(P<0.05).(iv)Compared to the total incidence of adverse reactions in the control group(28.00%),the incidence of total adverse reactions in the experimental group was lower at 10.00%,and the difference was significant(P<0.05).Conclusion:The combined inhalation of budesonide and formoterol with tiotropium bromide has demonstrated a clear therapeutic efficacy and safety in treating chronic obstructive pulmonary disease.This treatment approach effectively enhances arterial blood gas levels and lung function,showing promising potential for widespread application.展开更多
AIM To assess intestinal barrier function during human intestinal ischemia and reperfusion(IR).METHODS In a human experimental model,6 cm of jejunum was selectively exposed to 30 min of ischemia(I) followed by 30 and ...AIM To assess intestinal barrier function during human intestinal ischemia and reperfusion(IR).METHODS In a human experimental model,6 cm of jejunum was selectively exposed to 30 min of ischemia(I) followed by 30 and 120 min of reperfusion(R). A sham procedure was also performed. Blood and tissue was sampled at all-time points. Functional barrier function was assessed using dual-sugar absorption tests with lactulose(L) and rhamnose(R). Plasma concentrations of citrulline,an amino acid described as marker for enterocyte function were measured as marker of metabolic enterocytes restoration. Damage to the epithelial lining was assessed by immunohistochemistry for tight junctions( TJs),by plasma marker for enterocytes damage(I-FABP) and analyzed by electron microscopy(EM) using lanthanum nitrate as an electrondense marker.RESULTS Plasma L/R ratio's were significantly increased after 30 min of ischemia(30 I) followed by 30 min of reperfusion(30 R) compared to control(0.75 ± 0.10 vs 0.20 ± 0.09,P < 0.05). At 120 min of reperfusion(120 R),ratio's normalized(0.17 ± 0.06) and were not significantly different from control. Plasma levels of I-FABP correlated with plasma L/R ratios measured at the same time points(correlation: 0.467,P < 0.01). TJs staining shows distortion of staining at 30 I. An intact lining of TJs was again observed at 30 I120 R. Electron microscopy analysis revealed disrupted TJs after 30 I with paracellular leakage of lanthanum nitrate,which restored after 30 I120 R. Furthermore,citrulline concentrations closely paralleled the histological perturbations during intestinal IR.CONCLUSION This study directly correlates histological data with intestinal permeability tests,revealing that the human gut has the ability of to withstand short episodes of ischemia,with morphological and functional recovery of the intestinal barrier within 120 min of reperfusion.展开更多
Reusing test cases from existing test case library is quite common in the software testing field. Testing practice tells us that there is a strong relationship between the granularity of a function unit under testing ...Reusing test cases from existing test case library is quite common in the software testing field. Testing practice tells us that there is a strong relationship between the granularity of a function unit under testing and that of the test case. A function unit with small granularity usually results in the test cases with the same small granularity. Therefore a test case defined as the function point,i. e.,the smallest size function unit,was provided for the first time.Though test cases with smaller granularity usually have better reusability,the cost of accurately reusing and integrating such test cases is also higher. In order to balance the test case reusability and the cost of test case reuse,a novel test case reuse model based on the function point was proposed in this paper. In this model,a reusable test case for specification-based testing was defined and some reuse strategies and three formal reuse methods were given. Finally,the complete automatic software process was realized by a reusing generation tool. The new method has improved reuse accuracy,while greatly enhances the software productivity.展开更多
The digital substation system consists of an Intelligent Electronic Device (IED) which requires information for the supervision, protection, and control, as well as a client operating system for substation operation. ...The digital substation system consists of an Intelligent Electronic Device (IED) which requires information for the supervision, protection, and control, as well as a client operating system for substation operation. IEC 61850 communication standard has been defined for information exchange between heterogeneous digital devices in such substations. Currently, the Korea Electric Power Corporation (KEPCO) digital substation system uses unbuffered reporting and Generic Object Oriented Substation Events (GOOSE) communication functions for monitoring, protection and control automation. However, it is expected that the Setting Group function will be needed to operate adaptive intelligent substation system. The Setting Group function is advantageous in that it is possible to change the setting of the IED in one unified way through the client operating system, rather than changing the correction value of an IED through different manufacturer-based engineering tools. In order to utilize the Setting Group function of the IED in real substation scenario, it is necessary to test both the communication function with the host operating device and the electric functional test to ensure that correction value is properly changed. In this paper, we introduce the IEC 61850 Setting Group function, and propose a method that can integrate communication function and electrical function test of an IED conforming to the setting group functionality. We also tested the Setting Group function of the actual IED device through the proposed integrated functional test method and analyzed the results. We were able to simplify the process of testing both the electrical and communication signals in digital substations.展开更多
Background The relationship between the 6-minute walk test (6MWT) and pulmonary function test in stable chronic obstructive pulmonary disease (COPD) remains unclear. We evaluate the correlation of 6MWT and spirome...Background The relationship between the 6-minute walk test (6MWT) and pulmonary function test in stable chronic obstructive pulmonary disease (COPD) remains unclear. We evaluate the correlation of 6MWT and spirometric parameters in stable COPD with different severities. 6MWT data assessed included three variables: the 6-minute walk distance (6MWD), 6-minute walk work (6MWORK), and pulse oxygen desaturation rate (SPO2%). Methods 6MWT and pulmonary function test were assessed for 150 stable COPD patients with different severities. Means and standard deviations were calculated for the variables of interest. Analysis of variance was performed to compare means. Correlation coefficients were calculated for 6MWT data with the spirometric parameters and dyspnea Borg scale. Multiple stepwise regression analysis was used to screen pulmonary function-related predictors of 6MWT data. Results The three variables of 6MWT all varied as the severities of the disease. The 6MWD and 6MWORK both correlated with some spirometric parameters (positive or negative correlation; the absolute value of r ranging from 0.34 to 0.67; P 〈0.05) in severe and very severe patients, and the SPO2% correlated with the dyspnea Borg scale in four severities (t= -0.33, -0.34, -0.39, -0.53 respectively; P 〈0.05). The 6MWD was correlated with the 6MWORK in four severities (r=0.56, 0.57, 0.72, 0.81 respectively, P 〈0.05), and neither of them correlated with the SPO2%. The percent of predicted forced expiratory volume in 1 second (FEV1% predicted) and residual volume to total lung capacity ratio (RV/TLC) were predictors of the 6MWD, and the maximum voluntary ventilation (MW) was the predictor of the 6MWORK. Conclusions 6MWT correlated with the spirometric parameters in severe and very severe COPD patients. 6MWT may be used to monitor changes of pulmonary function in these patients.展开更多
文摘Objective. To study the difference of interstitial lung diseases (ILDs) in high-resolution computerized tomography and pulmonary function test among different connective tissue diseases (CTDs). Methods. 209 patients with different CTDs were recruited and underwent lung HRCT and PFT. Eerythrocyte sedimentation rate (ESR), C-reactive protein (CRP), serum ferritin (SF), anti-SSA, and so on were tested. Based on HRCT, a patient was classified into ILD group (CTD+ILD) or non-ILD group (CTD-ILD). HRCT, PFT, and laboratory markers were compared according to CTDs and CTD-associated ILDs. Results. The incidences of ILD were 79.6%, 82.0%, 89.7%, and 97.1% respectively for Rheumatoid arthritis (RA), primary Sjogren’s symptom (pSS), dermatomyositis/polymyositis (DM/PM), and systemic sclerosis (SSc) groups. RA and pSS patients exhibited more nodules, patching, ground-glass opacity, and cord shadow foci in HRCT, DM/PM and SSc patients exhibited more reticular opacity and honeycombing foci. RA and pSS patients exhibited more obstructive ventilatory disorder, small airway dysfunction and emphysema in PFT, and DM/PM and SSc patients exhibited more restrictive ventilatory disorder, mixed ventilatory disorder. ESR, CRP and SF were significantly higher in total CTD+ILD group than in total CTD-ILD group (P = 0.047, 0.006, 0.004, respectively), and higher in different CTD+ ILD groups than in comparable CTD-ILD groups (P = 0.049, 0.048, and 0.023, pSS+ILD, SSc+ILD and RA+ILD compared to pSS-ILD, SSc-ILD and RA-ILD, respectively for ESR, CRP, SF). The positive rate of anti-SSA was significantly higher in DM/PM+ILD group than in DM/PM-ILD group (P = 0.025). Conclusions. The manifestations and incidences of ILDs differ among different CTDs in HRCT and PFT, and inflammation and anti-SSA are positively correlated with ILDs in different CTDs, which provide important evidences for judging disease condition and prognosis.
基金funded by Department of Medicine, University of Udine (Udine, Italy) in accordance with Good Publication Practice (GPP3) guidelines (http://www.ismpp.org/gpp3)
文摘AIM To compare high-resolution computed tomography(HRCT) findings between humoral primary immunodeficiencies(hPIDs) subtypes; to correlate these findings to pulmonary function tests(PFTs).METHODS We retrospectively identified 52 consecutive adult patients with hPIDs who underwent 64-row HRCT and PFTs at the time of diagnosis. On a per-patient basis, an experienced radiologist recorded airway abnormalities(bronchiectasis,airway wall thickening, mucus plugging, tree-in-bud, and air-trapping) and parenchymal-interstitial abnormalities(consolidations, ground-glass opacities,linear and/or irregular opacities, nodules, and bullae/cysts) found on HRCT.The chi-square test was performed to compare the prevalence of each abnormality among patients with different subtypes of hPIDs. Overall logistic regression analysis was performed to assess whether HRCT findings predicted obstructive and/or restrictive PFTs results(absent-to-mild vs moderate-tosevere).RESULTS Thirty-eight of the 52 patients with hPIDs showed common variable immunodeficiency disorders(CVID), while the remaining 14 had CVID-like conditions(i.e., 11 had isolated IgG subclass deficiencies and 3 had selective IgA deficiencies). The prevalence of most HRCT abnormalities was not significantly different between CVID and CVID-like patients(P > 0.05), except for linear and/or irregular opacities(prevalence of 31.6% in the CVID group and 0 in the CVID-like group; P = 0.0427). Airway wall thickening was the most frequent HRCT abnormality found in both CVID and CVID-like patients(71% of cases in both groups). The presence of tree-in-bud abnormalities was an independent predictor of moderate-to-severe obstructive defects at PFTs(Odds Ratio, OR, of 18.75, P < 0.05), while the presence of linear and/or irregular opacities was an independent predictor of restrictive defects at PFTs(OR = 13.00; P < 0.05).CONCLUSION CVID and CVID-like patients showed similar HRCT findings. Tree-in-bud and linear and/or irregular opacities predicted higher risks of, respectively,obstructive and restrictive defects at PFTs.
文摘Objective: The aim of this preliminary study was to evaluate the feasibility of exercise testing (ET) for predicting postoperative complications in patients with impaired pulmonary function. Methods: Thirteen patients were prospectively enrolled. The enrollment criteria were FEV1.0% 8 by the Goddard classification or interstitial pneumonia on chest computed tomography. Patients underwent testing for pulmonary function, six-minute walking test (6MWT), and stair-climbing test (SCT). Postoperative cardiopulmonary complications (PCPCs) were recorded. Results: Four patients developed PCPCs. There were no significant differences between the patients with PCPCs (n = 4) and those without PCPCs (n = 9) for background data and PFT. The distances achieved in the 6MWT were 503 ± 72.7 m for patients without PCPCs and 369 ± 50.7 m for patients with PCPCs (p = 0.011). The SCT climbing heights were 20.4 ± 5.3 m for patients without PCPCs and 14.9 ± 4.0 m for patients with PCPCs (P = 0.187). Cut-off points, including a 6MFT distance of less than 400 m, SCT height lower than 15 m, and SCT climbing speed less than 8.5 m/min, were predictive of CPCP. Conclusions: Exercise testing is more feasible for predicting postoperative cardiopulmonary complications than stationary pulmonary function testing.
文摘We retrospectively assessed long-term pulmonary function in adults surviving for ≥5 years after myeloablative allogeneic hematopoietic stem cell transplantation and identified risk factors for late-onset noninfectious pulmonary complications. Among 174 patients undergoing transplantation for hematologic malignancies between May 1994 and December 2004, 81 long-term survivors were evaluated. Pulmonary function tests (PFTs) were performed before conditioning, 3 months and 1 year after transplantation, and then annually. Eight patients (10%) had abnormal pulmonary function before transplantation, but this was not associated with late changes in PFTs. Patients with chronic graft-versus-host disease (GVHD) showed a significant decline of lung function after 3 years when compared with patients without chronic GVHD. Abnormal pretransplantation lung function was associated with pulmonary chronic GVHD according to National Institutes of Health criteria (score 0, n = 58;score 1, n = 14;score 2, n = 6;score 3, n = 3). Five patients with late-onset noninfectious pulmonary complications showed a decline of lung function at 1 year after transplantation. Only chronic GVHD was significantly related to late-onset noninfectious pulmonary complications. In conclusion, abnormal lung function before transplantation may be associated with a decline in pulmonary function within 1 year after transplantation, but late-onset noninfectious pulmonary complications could not be predicted from pretransplantation lung function.
文摘Workers involved in hydraulic fracking processes are exposed to various types of chemicals and dusts in their workplaces, such as proppants, which hold open the fissures created in the fracking process. Recently, ceramic proppants have been developed that may be less hazardous to workers than traditional proppants. Pulmonary function testing of workers producing ceramic proppant was used to assess the potential inhalation hazards of ceramic proppant. 100 male workers from a producer of ceramic proppant were evaluated with pulmonary function test data collected and evaluated using The American Thoracic Society (ATS) acceptability criteria. A comparison group was selected from the Third National Health and Nutrition Examination Survey (NHANES III) spirometry laboratory subset. No pulmonary function deficits were found in the worker group in comparison to the NHANES III population. Mean FEV1 and FVC values in workers were 3.8 and 4.8 liters respectively, and were greater as compared to the NHANES III population of similar demographics. An FEV1/FVC ratio of less than 0.8, when compared to the NHANES III group, produced an odds ratio of 0.44 in worker group, indicating less risk of preclinical pulmonary dysfunction. Overall, exposure to ceramic proppant was not found to produce an adverse impact on pulmonary function in workers engaged in the manufacture of ceramic proppant.
文摘Breathing is considered the common factor that links studying,sleeping,and activities.It is one of the primary indicators that is frequently considered when determining whether or not an unconscious individual is still alive.The evolution and development process of the respiratory system that occurs in a foetus is primarily from head to tail(cephalocaudal).Many changes occur throughout this period until the 28th week of pregnancy at which the foetus^respiratory system will attain adequate development for the rest of his or her life.The respiratory system comprises of the lungs and the encompassing thoracic wall,which includes the thoracic cages,midriff(diaphragm),and the abdominal wall.Spirometry is a procedure used for estimating air volumes that enter and exit the pulmonary system with the aid of a spirometer.The various pulmonary parameters that reflect pulmonary ventilation are of great significance in diagnosing respiratory diseases.The respiratory system will be discussed in more detail in this article.
基金supported by the National Key R&D Program of China,No.2020YFC2004202(to DX).
文摘After stroke,even high-functioning individuals may experience compromised bimanual coordination and fine motor dexterity,leading to reduced functional independence.Bilateral arm training has been proposed as a promising intervention to address these deficits.However,the neural basis of the impairment of functional fine motor skills and their relationship to bimanual coordination performance in stroke patients remains unclear,limiting the development of more targeted interventions.To address this gap,our study employed functional near-infrared spectroscopy to investigate cortical responses in patients after stroke as they perform functional tasks that engage fine motor control and coordination.Twenty-four high-functioning patients with ischemic stroke(7 women,17 men;mean age 64.75±10.84 years)participated in this cross-sectional observational study and completed four subtasks from the Purdue Pegboard Test,which measures unimanual and bimanual finger and hand dexterity.We found significant bilateral activation of the sensorimotor cortices during all Purdue Pegboard Test subtasks,with bimanual tasks inducing higher cortical activation than the assembly subtask.Importantly,patients with better bimanual coordination exhibited lower cortical activation during the other three Purdue Pegboard Test subtasks.Notably,the observed neural response patterns varied depending on the specific subtask.In the unaffected hand task,the differences were primarily observed in the ipsilesional hemisphere.In contrast,the bilateral sensorimotor cortices and the contralesional hemisphere played a more prominent role in the bimanual task and assembly task,respectively.While significant correlations were found between cortical activation and unimanual tasks,no significant correlations were observed with bimanual tasks.This study provides insights into the neural basis of bimanual coordination and fine motor skills in high-functioning patients after stroke,highlighting task-dependent neural responses.The findings also suggest that patients who exhibit better bimanual performance demonstrate more efficient cortical activation.Therefore,incorporating bilateral arm training in post-stroke rehabilitation is important for better outcomes.The combination of functional near-infrared spectroscopy with functional motor paradigms is valuable for assessing skills and developing targeted interventions in stroke rehabilitation.
文摘AIM:To investigate pulmonary involvement via pulmonary function tests (PFT) and high-resolution computed tomography (HRCT) in patients with chronic hepatitis C virus (HCV) infection.METHODS:Thirty-four patients with chronic HCV infection without diagnosis of any pulmonary diseases and 10 healthy cases were enrolled in the study. PFT and HRCT were performed in all cases.RESULTS:A decrease lower than 80% of the predicted value was detected in vital capacity in 9/34 patients, in forced expiratory volume in one second in 8/34 palJents, and in forced expiratory flow 25-75 in 15/34 patients, respectively. Carbon monoxide diffusing capacity (DLCO) was decreased in 26/34 patients. Findings of interstitial pulmonary involvement were detected in bhe HRCT of 16/34 patients. Significant difference was found between controls and patients with HCV infection in findings of HRCT (X^2=4.7, P=0.003). Knodell histological activity index (KHAI) of 28/34 patients in whom liver biopsy was applied was 9.0±4.7. HRCT findings, PFT values and DLCO were not affected by KHAI in patients with HCV infection. In these patients, all the parameters were related with age.CONCLUSION: We suggest that chronic hepatitis C virus infection may cause pulmonary interstitial involvement without evident respiratory symptoms.
文摘Introduction: The Six-Minute Walk Test (6MWT) is an inexpensive method to objectively evaluate physical capacity or limitation and stratify prognosis in patients with Heart Failure (HF). Since the clinical perception of symptoms may be adapted or compromised, regular evaluation from medical interviews often fails to determine functional classification. This study aimed to assess the correlation between New York Heart Association Functional Class (NYHA-FC) and the distance walked in the 6MWT. Methods: We conducted a cross-sectional observational study that included patients with HF with reduced ejection fraction followed up at an outpatient service of a teaching hospital, from August 2018 to April 2019. Patients in NYHA-FC I, II, or III were included. We compared NYHA-FC subjectively obtained during the consultation with the 6MWT performed after medical consultation, and the correlation between these two parameters was assessed. Results: The study included 70 patients with HF, 41 (58.6%) of whom were female. The mean age was 61.2 ± 12.7 years. The most prevalent etiologies were dilated idiopathic cardiomyopathy (35.7%) followed by ischemic cardiomyopathy (25.7%). The mean ejection fraction was 34.1% ± 9.8%. The average distance walked in the 6MWT by NYHA-FC I patients was 437.8 ± 95.8 meters, NYHA-FC II 360.1 ± 96.4, and NYHA-FC III 248.4 ± 98.3. Functional class measured by the 6MWT was different than that estimated by NYHA-FC in 34 patients (48.6%), 23 (32.9%) for a higher functional class and 11 (15.7%) for a lower one (p = 0.07). Pearson’s correlation coefficient between NYHA-FC and the 6MWT was -0.55. Conclusion: There was a moderate correlation between the subjective NYHA-FC and the 6MWT. The 6MWT revealed a different classification from NYHA-FC in almost half of the patients. Among those who presented discrepancies between methods, 6MWT reclassification towards a higher functional class was more common.
文摘Background: Chronic heart failure is a public health problem worldwide. It has a high mortality rate and is accompanied by a decreased functional capacity and alteration of the quality of life. Objective: This study aimed to assess the cardiovascular functional capacity of a group of patients suffering from heart failure using the 6-minute walk test (6 MWT). Methods: This was a cross-sectional study carried out in the cardiology unit of Douala’s general hospital for 4 months. We included all eligible patients aged 18 years or more who had stable chronic heart failure and gave informed consent. Those who had an acute coronary syndrome (≤1 month), tachycardia (HR ≥ 120 bpm), high blood pressure (SBP ≥ 180 mmHg and/or DBP ≥ 100 mmHg) and reduced mobility due to orthopaedic reasons were excluded. A 6 MWT was done according to the American Thoracic Society guidelines. The 6 MWT result was considered poor for - 450 m and good for >450 m. Results: We recruited a total of 81 patients (61.7% women) with a mean age of 65.9 ± 10.6 years. The most frequent risk factor for heart failure was high blood pressure (77.8%), alcohol consumption(69.1%) and a sedentary lifestyle (53.1%). The left ventricular ejection fraction was mostly preserved (42.0%) or mildly altered (46.9). The 6 MWT results were poor in 55.6% of cases, average in 19.8% of cases and good in only 24.7% of cases. More than half (59.3%) of the participants perceived the effort as being difficult. The cardiovascular functional capacity was significantly associated with age, heart failure stage and physical activity (p Conclusion: Most patients suffering from chronic stable heart failure in the general hospital of Douala have poor cardiovascular functional capacity.
基金supported by grants funded by Department of Mechanical Engineering,Faculty of Engineering,Chiang Mai University and the Graduate School of Chiang Mai University.
文摘The objective of this research was to determine the mechanical parameter from EVA foam and also investigate its behavior by using Blatz-Ko,Neo-Hookean,Mooney model and experimental test.The physical characteristic of EVA foam was also evaluated by scanning electron microscopy(SEM).The results show that Blatz-Ko and Neo-Hookean model can fit the curve at 5%and 8%strain,respectively.The Mooney model can fit the curve at 50%strain.The modulus of rigidity evaluated from Mooney model is 0.0814±0.0027 MPa.The structure of EVA foam from SEM image shows that EVA structure is a closed cell with homogeneous porous structure.From the result,it is found that Mooney model can adjust the data better than other models.This model can be applied for mechanical response prediction of EVA foam and also for reference value in engineering application.
文摘BACKGROUND Lung cancer is a malignant tumor with high morbidity and mortality among cancers.Surgery is currently one of the primary methods of treating lung cancer.Although it can slow down the progression of the disease by removing the lesion,this invasive surgery inevitably damages the integrity of the patient’s chest.Moreover,the patient’s pulmonary function may have a low compensatory capacity after surgery,causing various respiratory diseases such as atelectasis,respiratory function decline,and even serious cardiovascular disease.All of these have great negative impacts on the surgical effect and the prognosis of patients.With the continuous exploration and development of nursing,continuous nursing and respiratory exercise nursing have been gradually applied in the nursing of patients after lung cancer surgery,and have achieved good nursing results.AIM To investigate the effect of continuous nursing combined with respiratory exercise nursing on the pulmonary function of postoperative patients with lung cancer.METHODS A total of 80 patients with lung cancer who underwent surgery in our hospital from January 2021 to December 2021 were selected as the study subjects.All subjects were randomly divided into the control group(n=40 cases)and the experimental group(n=40 cases).Patients with lung cancer in the control group were given conventional nursing after surgery,while the experimental group was given continuous nursing combined with respiratory exercise nursing based on conventional nursing.The recovery of pulmonary function and respiratory symptoms was observed before and after 3 mo of intervention in both groups.The pulmonary function parameters,blood gas analysis,MD Anderson Symptom Inventory-lung cancer module(MDASI-LC)scores,incidence of pulmonary complications,and Morisky compliance scores were compared between the two groups before and after 3 mo of intervention.RESULTS There was no significant difference in pulmonary function and blood gas analysis between the two groups before intervention(P>0.05).3 mo after the intervention,the pulmonary function parameters in the experimental group(SpO2,VC,MVV,FEV1,FEV1%pred,and FEV1/FVC)were higher than those in the control group,and the differences were statistically significant(P<0.05).There was no significant difference in blood gas analysis between the two groups before intervention(P>0.05).PaO2 in the experimental group was significantly higher than that in the control group,and PaCO_(2) was significantly lower than that in the control group 3 mo after the intervention.The difference had statistical significance(P<0.05).3 mo after the intervention,the MDASI score of respiratory symptoms in the experimental group was significantly lower than that in the control group(P<0.05),and the incidence of pulmonary complications was lower than that in the control group(P<0.05).In addition,the treatment compliance and nursing satisfaction of patients in the experimental group were higher than those in the control group,and the differences were statistically significant(P<0.05).CONCLUSION Continuous nursing combined with respiratory exercise nursing can significantly accelerate the recovery of respiratory function in postoperative lung cancer patients,reduce the incidence of postoperative complications of lung cancer as well as improve the treatment compliance of patients.
基金Supported by the Key-Area Research and Development Program of Guangdong Province,No.2022B1111070006the Guangdong Innovation Research Team for Higher Education,No.2021KCXTD025.
文摘BACKGROUND While colorectal polyps are not cancerous,some types of polyps,known as adenomas,can develop into colorectal cancer over time.Polyps can often be found and removed by colonoscopy;however,this is an invasive and expensive test.Thus,there is a need for new methods of screening patients at high risk of developing polyps.AIM To identify a potential association between colorectal polyps and small intestine bacteria overgrowth(SIBO)or other relevant factors in a patient cohort with lactulose breath test(LBT)results.METHODS A total of 382 patients who had received an LBT were classified into polyp and non-polyp groups that were confirmed by colonoscopy and pathology.SIBO was diagnosed by measuring LBTderived hydrogen(H)and methane(M)levels according to 2017 North American Consensus recommendations.Logistic regression was used to assess the ability of LBT to predict colorectal polyps.Intestinal barrier function damage(IBFD)was determined by blood assays.RESULTS H and M levels revealed that the prevalence of SIBO was significantly higher in the polyp group than in the non-polyp group(41%vs 23%,P<0.01;71%vs 59%,P<0.05,respectively).Within 90 min of lactulose ingestion,the peak H values in the adenomatous and inflammatory/hyperplastic polyp patients were significantly higher than those in the non-polyp group(P<0.01,and P=0.03,respectively).In 227 patients with SIBO defined by combining H and M values,the rate of IBFD determined by blood lipopolysaccharide levels was significantly higher among patients with polyps than those without(15%vs 5%,P<0.05).In regression analysis with age and gender adjustment,colorectal polyps were most accurately predicted with models using M peak values or combined H and M values limited by North American Consensus recommendations for SIBO.These models had a sensitivity of≥0.67,a specificity of≥0.64,and an accuracy of≥0.66.CONCLUSION The current study made key associations among colorectal polyps,SIBO,and IBFD and demonstrated that LBT has moderate potential as an alternative noninvasive screening tool for colorectal polyps.
基金Supported by Special Research Project of Science and Technology Bureau of Nanchong City,Sichuan Province"Effects of TCM Nursing Based on Syndrome Differentiation on Pulmonary Function and Quality of Life in Patients with Acute Exacerbation of COPD"(22YYJCYJ0057)Science and Technology Program of Sichuan Province"Effects of TCM Nursing Based on Syndrome Differentiation on Pulmonary Function and Quality of Life in Patients with Acute Exacerbation of COPD"(2021YFS0270).
文摘[Objectives] To investigate the effects of TCM nursing based on syndrome differentiation on pulmonary function and quality of life in patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). [Methods] A total of 92 patients with AECOPD who came to Nanchong Chinese Medicine Hospital from March 2022 to February 2023 were selected for the study, and the intervention group (TCM nursing based on syndrome differentiation, 46 cases) and the conventional group (basic nursing, 46 cases) were selected for the study, and the pulmonary function and quality of life of the two groups were compared. [Results] Before nursing, there was no significant difference in levels of forced vital capacity (FVC), forced expiratory volume in one second (FEV1), and percentage of forced expiratory volume in one second to forced vital capacity (FEV1/FVC) between the intervention group and conventional group ( P >0.05). After 3 months of nursing, the levels of FVC, FEV1 and FEV1/FVC in the intervention group were higher than those in the conventional group ( P <0.05). Before nursing, there was no significant difference in the scores of health, emotion and social functions between the two groups ( P >0.05). At three months of nursing, the scores of health, emotion, and social functions in the intervention group were higher than those in the conventional group ( P <0.05). [Conclusions] The implementation of TCM nursing based on syndrome differentiation in patients with AECOPD can effectively improve the pulmonary function and quality of life of patients, and has significant clinical implementation value.
文摘Objective:To analyze the effect of combined inhalation of budesonide formoterol and tiotropium bromide on arterial blood gas and pulmonary function indexes in patients with chronic obstructive pulmonary disease(COPD).Methods:100 patients with COPD treated from January to December 2022 were selected as observation objects,and were divided into a control group(n=50,in which budesonide and formoterol were administered)and an experimental group(n=50,the treatment drug was budesonide formoterol combined with tiotropium bromide)according to the computer grouping method,and compared the treatment results.Results:(i)Before treatment,there was no difference in the partial pressure of carbon dioxide and partial pressure of oxygen between the control group and the experimental group(P>0.05);after treatment,the partial pressure of carbon dioxide and partial pressure of oxygen in the experimental group were higher than those in the control group,with significant differences(P<0.05).(ii)Before treatment,there was no difference in forced vital capacity(FVC),forced expiratory volume in one second(FEV1),FEV1/FVC between the control group and the experimental group(P>0.05);after treatment,the FVC,FEV1,and FEV1/FVC in the experimental group were significantly higher than those in the control group(P<0.05).(iii)There was no difference in the levels of CRP,IL-6,and TNF-αbetween the control group and the experimental group(P>0.05);after treatment,the levels of CRP,IL-6,and TNF-αin the experimental group were lower than those in the control group,with significant differences(P<0.05).(iv)Compared to the total incidence of adverse reactions in the control group(28.00%),the incidence of total adverse reactions in the experimental group was lower at 10.00%,and the difference was significant(P<0.05).Conclusion:The combined inhalation of budesonide and formoterol with tiotropium bromide has demonstrated a clear therapeutic efficacy and safety in treating chronic obstructive pulmonary disease.This treatment approach effectively enhances arterial blood gas levels and lung function,showing promising potential for widespread application.
基金Supported by Dutch Digestive Foundation(MLDS grant WO10-57 to Dejong CHC and Lenaerts K)and MLDS Career development grant CDG13-14 to Derikx JPM)the Netherlands Organisation for Scientific Research(Rubicon grant 2013/07161/ALW to Grootjans J)
文摘AIM To assess intestinal barrier function during human intestinal ischemia and reperfusion(IR).METHODS In a human experimental model,6 cm of jejunum was selectively exposed to 30 min of ischemia(I) followed by 30 and 120 min of reperfusion(R). A sham procedure was also performed. Blood and tissue was sampled at all-time points. Functional barrier function was assessed using dual-sugar absorption tests with lactulose(L) and rhamnose(R). Plasma concentrations of citrulline,an amino acid described as marker for enterocyte function were measured as marker of metabolic enterocytes restoration. Damage to the epithelial lining was assessed by immunohistochemistry for tight junctions( TJs),by plasma marker for enterocytes damage(I-FABP) and analyzed by electron microscopy(EM) using lanthanum nitrate as an electrondense marker.RESULTS Plasma L/R ratio's were significantly increased after 30 min of ischemia(30 I) followed by 30 min of reperfusion(30 R) compared to control(0.75 ± 0.10 vs 0.20 ± 0.09,P < 0.05). At 120 min of reperfusion(120 R),ratio's normalized(0.17 ± 0.06) and were not significantly different from control. Plasma levels of I-FABP correlated with plasma L/R ratios measured at the same time points(correlation: 0.467,P < 0.01). TJs staining shows distortion of staining at 30 I. An intact lining of TJs was again observed at 30 I120 R. Electron microscopy analysis revealed disrupted TJs after 30 I with paracellular leakage of lanthanum nitrate,which restored after 30 I120 R. Furthermore,citrulline concentrations closely paralleled the histological perturbations during intestinal IR.CONCLUSION This study directly correlates histological data with intestinal permeability tests,revealing that the human gut has the ability of to withstand short episodes of ischemia,with morphological and functional recovery of the intestinal barrier within 120 min of reperfusion.
基金National Natural Science Foundation of China(No.61262010)
文摘Reusing test cases from existing test case library is quite common in the software testing field. Testing practice tells us that there is a strong relationship between the granularity of a function unit under testing and that of the test case. A function unit with small granularity usually results in the test cases with the same small granularity. Therefore a test case defined as the function point,i. e.,the smallest size function unit,was provided for the first time.Though test cases with smaller granularity usually have better reusability,the cost of accurately reusing and integrating such test cases is also higher. In order to balance the test case reusability and the cost of test case reuse,a novel test case reuse model based on the function point was proposed in this paper. In this model,a reusable test case for specification-based testing was defined and some reuse strategies and three formal reuse methods were given. Finally,the complete automatic software process was realized by a reusing generation tool. The new method has improved reuse accuracy,while greatly enhances the software productivity.
文摘The digital substation system consists of an Intelligent Electronic Device (IED) which requires information for the supervision, protection, and control, as well as a client operating system for substation operation. IEC 61850 communication standard has been defined for information exchange between heterogeneous digital devices in such substations. Currently, the Korea Electric Power Corporation (KEPCO) digital substation system uses unbuffered reporting and Generic Object Oriented Substation Events (GOOSE) communication functions for monitoring, protection and control automation. However, it is expected that the Setting Group function will be needed to operate adaptive intelligent substation system. The Setting Group function is advantageous in that it is possible to change the setting of the IED in one unified way through the client operating system, rather than changing the correction value of an IED through different manufacturer-based engineering tools. In order to utilize the Setting Group function of the IED in real substation scenario, it is necessary to test both the communication function with the host operating device and the electric functional test to ensure that correction value is properly changed. In this paper, we introduce the IEC 61850 Setting Group function, and propose a method that can integrate communication function and electrical function test of an IED conforming to the setting group functionality. We also tested the Setting Group function of the actual IED device through the proposed integrated functional test method and analyzed the results. We were able to simplify the process of testing both the electrical and communication signals in digital substations.
文摘Background The relationship between the 6-minute walk test (6MWT) and pulmonary function test in stable chronic obstructive pulmonary disease (COPD) remains unclear. We evaluate the correlation of 6MWT and spirometric parameters in stable COPD with different severities. 6MWT data assessed included three variables: the 6-minute walk distance (6MWD), 6-minute walk work (6MWORK), and pulse oxygen desaturation rate (SPO2%). Methods 6MWT and pulmonary function test were assessed for 150 stable COPD patients with different severities. Means and standard deviations were calculated for the variables of interest. Analysis of variance was performed to compare means. Correlation coefficients were calculated for 6MWT data with the spirometric parameters and dyspnea Borg scale. Multiple stepwise regression analysis was used to screen pulmonary function-related predictors of 6MWT data. Results The three variables of 6MWT all varied as the severities of the disease. The 6MWD and 6MWORK both correlated with some spirometric parameters (positive or negative correlation; the absolute value of r ranging from 0.34 to 0.67; P 〈0.05) in severe and very severe patients, and the SPO2% correlated with the dyspnea Borg scale in four severities (t= -0.33, -0.34, -0.39, -0.53 respectively; P 〈0.05). The 6MWD was correlated with the 6MWORK in four severities (r=0.56, 0.57, 0.72, 0.81 respectively, P 〈0.05), and neither of them correlated with the SPO2%. The percent of predicted forced expiratory volume in 1 second (FEV1% predicted) and residual volume to total lung capacity ratio (RV/TLC) were predictors of the 6MWD, and the maximum voluntary ventilation (MW) was the predictor of the 6MWORK. Conclusions 6MWT correlated with the spirometric parameters in severe and very severe COPD patients. 6MWT may be used to monitor changes of pulmonary function in these patients.