Since the inaugural international collaboration under the framework of the Collaboratory for the Study of Earthquake Predictability(CSEP)in 2007,numerous forecast models have been developed and operated for earthquake...Since the inaugural international collaboration under the framework of the Collaboratory for the Study of Earthquake Predictability(CSEP)in 2007,numerous forecast models have been developed and operated for earthquake forecasting experiments across CSEP testing centers(Schorlemmer et al.,2018).Over more than a decade,efforts to compare forecasts with observed earthquakes using numerous statistical test methods and insights into earthquake predictability,which have become a highlight of the CSEP platform.展开更多
Despite the widespread use of malaria rapid diagnostic test(RDT)in clinical practice,there are a lot of challenges.We conducted a secondary analysis of 129 malaria RDT data from rounds 5–8 of the World Health Organiz...Despite the widespread use of malaria rapid diagnostic test(RDT)in clinical practice,there are a lot of challenges.We conducted a secondary analysis of 129 malaria RDT data from rounds 5–8 of the World Health Organization(WHO)product testing summary and discuss the causes of false-negative(FN)results with a focus on low parasite density,improper RDT storage,operation and interpretation,and Plasmodium falciparum with a pfhrp2/3 gene deletion.The results demonstrated that the malaria RDTs currently commercially available might cause FN results in practice.展开更多
BACKGROUND An inconclusive result from BRCA1/2 genetic testing indicates that a genetic variant of uncertain significance is detected.This case constitutes the majority of genetic test results,but studies specifically...BACKGROUND An inconclusive result from BRCA1/2 genetic testing indicates that a genetic variant of uncertain significance is detected.This case constitutes the majority of genetic test results,but studies specifically addressing the psychological adjustment of people with inconclusive results are scarce.AIM To examine psychological outcomes of receiving an uninformative BRCA1/2 test result.METHODS PubMed,PsychInfo,and Cochrane Central Register of Controlled Trials were screened for studies focusing on distress,anxiety,and depression levels in individuals with inconclusive genetic test results.This review is based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses method.RESULTS Studies on psychological outcomes of inconclusive BRCA1/2 focused on general and specific distress,anxiety,and depression.Overall,they produced mixed results.These inconsistent findings are probably due to the uncertainty caused by this type of result,that may also influence the decisions of individuals about surveillance and prophylactic options,reducing their compliance.In addition,this review highlights specific risk and protective factors that affect psychological adjustment in individuals with an inconclusive genetic testing result.CONCLUSION Individuals with inconclusive genetic test results need specific educational programs and support to better understand the meaning of their results in order to be able to make decisions about surveillance and prophylactic options.展开更多
Natural space presents a complicated radiation environment containing various energetic particle types at different flux level and the flux of the particles is not constant modulating by solar activities[1]. On the ot...Natural space presents a complicated radiation environment containing various energetic particle types at different flux level and the flux of the particles is not constant modulating by solar activities[1]. On the other hand, the heavy ion flux applied in ground based single event test was commonly set at a fixed value. Refs. [2] and [3] both pointed out that the single event test result of harden device may exhibit flux dependency. It is necessary to fully study the ion flux dependency on single event effect.展开更多
To evaluate the safety of detergents,the toxicological test results of 580 collected detergents were analyzed.The results showed that,in the acute oral toxicity test,94.4%and 5.6%of the samples were classified as non-...To evaluate the safety of detergents,the toxicological test results of 580 collected detergents were analyzed.The results showed that,in the acute oral toxicity test,94.4%and 5.6%of the samples were classified as non-toxic and toxic respectively.In skin irritation test,95.1%of the samples were mild irritation or below,and 4.9%were moderate irritation or above.In the vaginal mucosa irritation test,79.0%of the samples were very mild irritation or below,while 21.0%were mild irritation or above.In the acute inhalation toxicity test,the proportion of the samples classified as actually non-toxic and toxic were 87.9%and 12.1%respectively.In the eye irritation test,95.7%of the samples belonged to mild irritation or below,and 4.3%of the samples belonged to moderate irritation or above.The products at risk in category A,B and C products account for 6.3%,7.7%and 14.2%respectively.Of the 580 tested samples,90.9%were relatively safe,while 9.1%were at risk.These data showed that most of the tested samples meet the safety requirements for use.展开更多
Objective To investigate cumulative results of chemosensitivity test using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl (MTT) assay in double-layer agarose. Methods A total of 2 491 patients with different kinds of c...Objective To investigate cumulative results of chemosensitivity test using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl (MTT) assay in double-layer agarose. Methods A total of 2 491 patients with different kinds of cancers were enrolled in the study, in which 18 kinds of different anticancer drugs were used. A computer soft was used to get charts. ResultsThe total evaluability rate was 82.7% (2 060/2 491). Among all agents, the efficiency rates of 5-Fu, MMC, DDP, BLM and CBP were higher than the efficiency rates of others. The response rate range of different cancer in vitro sensitivity by using MTT assay in double layer agarose were from 9.2% (biliary duct) to 37.5% (malignant lymphoma). For colon and rectum cancer, 5-Fu, DDP, MMC and BLM were more sensitive than other anti-tumor agents. For breast carcinomas, ACTD and DDP were more sensitive. For gastric cancer, 5-Fu, DDP and BLM were more sensitive. For leukemia, VM-26 and HHRT were more sensitive. ACM was more sensitive to kidney and MXT and BLM were more sensitive to pancreas cancer. For Lung cancer, DDP and EPI were more sensitive. Mean true positive rate, mean true negative rate, mean sensitivity, mean specificity and mean accuracy were 44% , 92% , 72% , 77% , and 76% , respectively. Conclusion Chemosensitivity tesing using the MTT assay in a double layer agarose was a very useful reference to chem- therapy.展开更多
To make oral test accurately reflect the actual English spoken ability of candidates and play its role in guiding and promoting the improvement of English learners in the teaching, we must ensure that the design of sc...To make oral test accurately reflect the actual English spoken ability of candidates and play its role in guiding and promoting the improvement of English learners in the teaching, we must ensure that the design of scientific questions, the feasibility and validity of judgments to make an accurate and fair measurement of testers' language ability.展开更多
AIM To assess the diagnostic accuracy of a new fecal test for detecting Helicobacter pylori(H. pylori), using ^(13)Curea breath test as the reference standard, and explore bacterial antibiotic resistance. METHODS We c...AIM To assess the diagnostic accuracy of a new fecal test for detecting Helicobacter pylori(H. pylori), using ^(13)Curea breath test as the reference standard, and explore bacterial antibiotic resistance. METHODS We conducted a prospective two-center diagnostic test accuracy study. We enrolled consecutive people≥ 18 years without previous diagnosis of H. pylori infection, referred for dyspepsia between February and October 2017. At enrollment, all participants underwent 13 C-urea breath test. Participants aged over 50 years were scheduled to undergo upper endoscopy with histology. Participants collected stool samples 1-3 d after enrollment for a new fecal investigation(THD fecal test). The detection of bacterial 23 S rRNA subunit gene indicated H. pylori infection. We also used the index diagnostic test to examine mutations conferring resistance to clarithromycin and levofloxacin. Independent investigators analyzed index test and reference test standard results blinded to the other test findings. We estimated sensitivity, specificity, positive(PPV) and negative(NPV) predictive value, diagnostic accuracy, positive and negative likelihood ratio(LR), together with 95% confidence intervals(CI).RESULTS We enrolled 294 consecutive participants(age: Median 37.0 years, IQR: 29.0-46.0 years; men: 39.8%). Ninetyfive(32.3%) participants had a positive ^(13)C-urea breath test. Twenty-three(7.8%) participants underwent upper endoscopy with histology, with a full concordance between ^(13)C-urea breath test and histology in detecting H. pylori infection. Four(1.4%) out of the 294 participants withdrew from the study after the enrollment visit and did not undergo THD fecal testing. In the 290 participants who completed the study, the THD fecal test sensitivity was 90.2%(CI: 84.2%-96.3%), specificity 98.5%(CI:96.8%-100%), PPV 96.5%(CI: 92.6%-100%), NPV 95.6%(CI: 92.8%-98.4%), accuracy 95.9%(CI: 93.6%-98.2%), positive LR 59.5(CI: 19.3-183.4), negative LR 0.10(CI: 0.05-0.18). Out of 83 infected participants identified with the THD fecal test, 34(41.0%) had bacterial genotypic changes consistent with antibiotic-resistant H. pylori infection. Of these, 27(32.5%) had bacterial strains resistant to clarithromycin, 3(3.6%) to levofloxacin, and 4(4.8%) to both antibiotics. CONCLUSION The THD fecal test has high performance for the non-invasive diagnosis of H. pylori infection while additionally enabling the assessment of bacterial antibiotic resistances.展开更多
AIM:To study intestinal permeability(IP) and its relationship to the disease activity in patients with inflammatory bowel diseases(IBD)-Crohn's disease(CD) and ulcerative colitis(UC).METHODS:Fifty-eight patients w...AIM:To study intestinal permeability(IP) and its relationship to the disease activity in patients with inflammatory bowel diseases(IBD)-Crohn's disease(CD) and ulcerative colitis(UC).METHODS:Fifty-eight patients with active IBD(32 with CD and 26 with UC) and 25 healthy controls consented to participate in the study.The clinical activity of CD was estimated using the Crohn's Disease Activity Index(CDAI),and the endoscopic activity of UC using the Mayo scoring system.IP was assessed by the rise in levels of iohexol,which was administered orally(25 mL,350 mg/mL) 2 h after breakfast.Three and six hours later serum(SIC mg/L) and urine(UIC g/mol) iohexol concentrations were determined by a validated HPLC-UV technique.RESULTS:In the CD group,SIC values at 3 h(2.95 ± 2.11 mg/L) and at 6 h after ingestion(2.63 ± 2.18 mg/L) were significantly higher compared to those of healthy subjects(1.25 ± 1.40 mg/L and 1.11 ± 1.10 mg/L,respectively,P < 0.05).UIC(g/mol) values were also higher in patients,but the differences were significant only for UIC at 6 h.Significant positive correlation(P < 0.05) was found between the CDAI and IP,assessed by SIC at 3 h(r = 0.60) and 6 h(r = 0.74) after the ingestion.In comparison to controls,SIC and UIC of UC patients were higher in the two studied periods,but the differences were significant at 6 h only.Significantly higher values of SIC(P < 0.05) were found in patients with severe endoscopic activity of UC compared to those of patients with mild and moderate activity(3.68 ± 3.18 vs 0.92 ± 0.69 mg/L).CONCLUSION:Serum levels of iohexol at 3 h and 6 h after its ingestion reflect increased IP,which is related to the disease activity in patients with IBD.展开更多
Mechanical properties of structural materials are particularly important for design, performance realization and reliability analysis of microelectromechanical systems (MEMS). Furthermore, accurate database of mecha...Mechanical properties of structural materials are particularly important for design, performance realization and reliability analysis of microelectromechanical systems (MEMS). Furthermore, accurate database of mechanical properties at the micro scale can provide indispensable reference for establishing MEMS standard. Electroplated nickel film is one of the most favored structural materials used in MEMS, thus its mechanical properties has been studied for many years. However, the measured values show large scatter in Yotmg's modulus of nickel film. Young's modulus and yield stress of electroplated nickel film are measured by using a micro-tensile testing instrument. The tensile load applied on the specimen is measured by a load cell with accuracy 0.25 mN directly, without additional friction. Through measuring the axial stiffness coefficient of the tensile instnunent in situ, the tensile strain of the specimen is obtained by using two-serial spring model. The electroplated nickel films were fabricated from sulfarnate baths, and the gauge section is 500μm long and 10μm wide nominally, and thickness range between 25 μm and 50μm. The obtained Young's modulus from tensile testing is 83+6 GPa for nickel specimens electroplated at current density of 20 mA/cm2 and it increases to 124+5 GPa as current density is decreased to 10 mA/cm2. The phenomena are interpreted in terms of porosity of microstructure. The higher current density produced rnicrostucture with low density and high volume fraction of pores, and the microstructure of high porosity corresponds to a lower modulus. The measured values of Young's modulus are consistent with those of calculated from the exponential empirical formula between Young's modulus and porosity. The micro-tensile testing instrument can also be used for mechanical measurement of other MEMS films.展开更多
The success of the tuned mass damper (TMD) in reducing wind-induced structural vibrations has been well established. However, from most of the recent numerical studies, it appears that for a structure situated on very...The success of the tuned mass damper (TMD) in reducing wind-induced structural vibrations has been well established. However, from most of the recent numerical studies, it appears that for a structure situated on very soft soil, soil-structure interaction (SSI) could render a damper on the structure totally ineffective. In order to experimentally verify the SSI effect on the seismic performance of TMD, a series of shaking table model tests have been conducted and the results are presented in this paper. It has been shown that the TMD is not as effective in controlling the seismic responses of structures built on soft soil sites due to the SSI effect. Some test results also show that a TMD device might have a negative impact if the SSI effect is neglected and the structure is built on a soft soil site. For structures constructed on a soil foundation, this research verifies that the SSI effect must be carefully understood before a TMD control system is designed to determine if the control is necessary and if the SSI effect must be considered when choosing the optimal parameters of the TMD device.展开更多
BACKGROUND 1,3-beta-D-glucan(BG)is a ubiquitous cell wall component of gut microorganisms.We hypothesized that the serum levels of BG could reflect active intestinal inflammation in patients with inflammatory bowel di...BACKGROUND 1,3-beta-D-glucan(BG)is a ubiquitous cell wall component of gut microorganisms.We hypothesized that the serum levels of BG could reflect active intestinal inflammation in patients with inflammatory bowel disease.AIM To determine whether the serum BG concentrations correlate with intestinal inflammation.METHODS A prospective observational study was performed in a tertiary referral center,from 2016 to 2019,in which serum BG was determined in 115 patients with Crohn’s disease(CD),51 with ulcerative colitis(UC),and 82 controls using a photometric detection kit.Inflammatory activity was determined by ileocolonoscopy,histopathology,magnetic resonance enterography,and biomarkers,including fecal calprotectin(FC),C-reactive protein,and a panel of cytokines.The ability of BG to detect active vs inactive disease was assessed using the area under the receiver operating characteristic curve.In subgroup analysis,serial BG was used to assess the response to therapeutic interventions.RESULTS The serum BG levels were higher in CD patients than in controls(P=0.0001).The BG levels paralleled the endoscopic activity in CD patients and histologic activity and combined endoscopic and histologic activity in both CD and UC patients.The area under the curve(AUC)in receiver operating characteristic analysis to predict endoscopic activity was 0.694[95%confidence interval(CI):0.60-0.79;P=0.001]in CD,and 0.662(95%CI:0.51-0.81;P=0.066)in UC patients.The AUC in receiver operating characteristic analysis to predict histologic activity was 0.860(95%CI:0.77-0.95;P<0.001)in CD,and 0.786(95%CI:0.57-0.99;P=0.015)in UC patients.The cut-off values of BG for both endoscopic and histologic activity were 60μg/mL in CD,and 40μg/mL in UC patients.Performance analysis showed that the results based on BG of 40 and 60μg/mL were more specific for predicting endoscopic activity(71.8%and 87.2%for CD;and 87.5%and 87.5%for UC,respectively)than FC(53.3%and 66.7%for CD;and 20%and 80%for UC,respectively);and also histologic activity(60.5%and 76.3%for CD;and 90.0%and 95.0%for UC,respectively)than FC(41.7%and 50.0%for CD;and 25%and 50%for UC,respectively).Regarding the clinical,endoscopic,and histologic activities,the BG levels were reduced following therapeutic intervention in patients with CD(P<0.0001)and UC(P=0.003).Compared with endoscopic(AUC:0.693;P=0.002)and histologic(AUC:0.868;P<0.001)activity,no significant correlation was found between serum BG and transmural healing based on magnetic resonance enterography(AUC:0.576;P=0.192).Positive correlations were detected between BG and IL-17 in the CD(r:0.737;P=0.001)and the UC group(r:0.574;P=0.005),and between BG and interferon-gamma in the CD group(r:0.597;P=0.015).CONCLUSION Serum BG may represent an important novel noninvasive approach for detecting mucosal inflammation and therapeutically monitoring inflammatory bowel diseases,particularly in CD.展开更多
The stress on a test specimen during tensile testing is generally measured by a strain gauge. This method has some problems in that it would influence the measurement conditions of the tensile test and can evaluate on...The stress on a test specimen during tensile testing is generally measured by a strain gauge. This method has some problems in that it would influence the measurement conditions of the tensile test and can evaluate only the position at which the strain gauge is attached. The acoustoelastic method is proposed as a method replacing the strain gauge method. However, an ultrasonic sensor with a piezoelectric oscillator requires a coupling medium to inject an ultrasonic wave into a solid material. This condition, due to the error factor of the stress measurement, makes it difficult for the ultrasonic sensor to move on the specimen. We then tried to develop a non-contact stress measurement system during tensile testing using an electromagnetic acoustic transducer (EMAT) with an SH0-plate wave and S0-Lamb wave. The EMAT can measure the propagation time in which the ultrasonic wave travels between a receiver and a transmitter without a coupling medium during the tensile testing and can move easily. The interval between the transmitter and the receiver is 10mm and can be moved along the parallel direction or the vertical direction of the tensile load. The transit time was measured by a cross-correlation method and converted into the stress on the test specimen using the acoustoelastic method. We confirmed that the stress measurement using an SH0-plate wave was superior to that with an S0-Lamb wave.展开更多
Calcined ginger nuts admixed by fly ash and quartz sand (CGN-(F+S)) has been validated to be basically compatible to earthen sites as an anchor grout. Accelerated ageing tests including water stability test, temperatu...Calcined ginger nuts admixed by fly ash and quartz sand (CGN-(F+S)) has been validated to be basically compatible to earthen sites as an anchor grout. Accelerated ageing tests including water stability test, temperature and humidity cycling test, soundness test and alkali resistance test are conducted with the objective to further research the property changes of CGN-(F+S) grout. Density, surface hardness, water penetration capacity, water permeability capacity, soluble salt, scanning electron microscopy (SEM) images and energy dispersive spectrometry (EDS) spectrum of these samples have been tested after accelerated ageing tests. The results show that densities of samples decrease, surface hardness, water penetration capacity and water permeability capacity of samples increase generally. Besides, soluble salt analysis, SEM and EDS results well corroborate the changes. Based on the results it can be concluded that property changes are most serious after temperature and humidity cycling test, followed by water stability, soundness and alkali resistance test in sequence. But in general, CGN-(F+S) still has good durability.展开更多
The flat cylindrical indentation tests with different sizes of punch radius were investigated using finite element method (FEM) aimed to reveal the effect of punch size on the indentation behavior of the film/substr...The flat cylindrical indentation tests with different sizes of punch radius were investigated using finite element method (FEM) aimed to reveal the effect of punch size on the indentation behavior of the film/substrate system. Based on the FEM results analysis, two methods was proposed to separate film's reduced Young's modulus from a film/substrate system. The first method was based on a new weight function that quantifies film's and substrate's contributions to the overall mechanical properties of the film/substrate system in the flat cylindrical indentation test. The second method, a numerical approach, including fitting and extrapolation procedures was put forward. Both of the results from the two methods showed a reasonable agreement with the one input FE model. At last, the effect of maximum indentation depth and the surface micro-roughness of the thin film on the reduced Young's modulus of the film/substrate system were discussed. The methods proposed in the present study provide some new conceptions on evaluating other properties of thin films, e.g. creep, for which a flat-ended punch is also employed.展开更多
This paper derives the variance of the information content and develops its statistical inference method. We describe the relations between information content and sensitivity, specificity, efficiency, prevalence rate...This paper derives the variance of the information content and develops its statistical inference method. We describe the relations between information content and sensitivity, specificity, efficiency, prevalence rate. If sensitivity, specificity and efficiency are fixed, the closer to 0. 5 the prevalence rate is, the more the information content. If prevalence rate and efficiency are fixed, the closer to each other the sensitivity and specificity are, the more the information content. We compare the power of information content method, efficiecy test, Youden's index test and kappa coefficient method. The information content method has higher power than the other methods in most conditions. It is especially sensitive to the difference between two sensitivities. It comes to conclusion that the information content method has more virtues than the other methods mentioned in this paper.展开更多
In this paper,we considered the Length-biased weighted Lomax distribution and constructed new acceptance sampling plans(ASPs)where the life test is assumed to be truncated at a pre-assigned time.For the new suggested ...In this paper,we considered the Length-biased weighted Lomax distribution and constructed new acceptance sampling plans(ASPs)where the life test is assumed to be truncated at a pre-assigned time.For the new suggested ASPs,the tables of the minimum samples sizes needed to assert a specific mean life of the test units are obtained.In addition,the values of the corresponding operating characteristic function and the associated producer’s risks are calculated.Analyses of two real data sets are presented to investigate the applicability of the proposed acceptance sampling plans;one data set contains the first failure of 20 small electric carts,and the other data set contains the failure times of the air conditioning system of an airplane.Comparisons are made between the proposed acceptance sampling plans and some existing acceptance sampling plans considered in this study based on the minimum sample sizes.It is observed that the samples sizes based on the proposed acceptance sampling plans are less than their competitors considered in this study.The suggested acceptance sampling plans are recommended for practitioners in the field.展开更多
基金granted by the National Natural Science Foundation of China(Grant No.42004038)Earthquake Tracking Orientation Tasks of CEA(Grant No.2024020104)+1 种基金the Special Fund of IEFCEA(Grant No.CEAIEF2022030206)the China Scholarship Council(CSC)exchange program(Grant No.202204190019)。
文摘Since the inaugural international collaboration under the framework of the Collaboratory for the Study of Earthquake Predictability(CSEP)in 2007,numerous forecast models have been developed and operated for earthquake forecasting experiments across CSEP testing centers(Schorlemmer et al.,2018).Over more than a decade,efforts to compare forecasts with observed earthquakes using numerous statistical test methods and insights into earthquake predictability,which have become a highlight of the CSEP platform.
基金supported by the National Grand Program on Key Infectious Disease(2018ZX10103002-001-007)the Biosafety Special Program(19SWAQ 13)。
文摘Despite the widespread use of malaria rapid diagnostic test(RDT)in clinical practice,there are a lot of challenges.We conducted a secondary analysis of 129 malaria RDT data from rounds 5–8 of the World Health Organization(WHO)product testing summary and discuss the causes of false-negative(FN)results with a focus on low parasite density,improper RDT storage,operation and interpretation,and Plasmodium falciparum with a pfhrp2/3 gene deletion.The results demonstrated that the malaria RDTs currently commercially available might cause FN results in practice.
文摘BACKGROUND An inconclusive result from BRCA1/2 genetic testing indicates that a genetic variant of uncertain significance is detected.This case constitutes the majority of genetic test results,but studies specifically addressing the psychological adjustment of people with inconclusive results are scarce.AIM To examine psychological outcomes of receiving an uninformative BRCA1/2 test result.METHODS PubMed,PsychInfo,and Cochrane Central Register of Controlled Trials were screened for studies focusing on distress,anxiety,and depression levels in individuals with inconclusive genetic test results.This review is based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses method.RESULTS Studies on psychological outcomes of inconclusive BRCA1/2 focused on general and specific distress,anxiety,and depression.Overall,they produced mixed results.These inconsistent findings are probably due to the uncertainty caused by this type of result,that may also influence the decisions of individuals about surveillance and prophylactic options,reducing their compliance.In addition,this review highlights specific risk and protective factors that affect psychological adjustment in individuals with an inconclusive genetic testing result.CONCLUSION Individuals with inconclusive genetic test results need specific educational programs and support to better understand the meaning of their results in order to be able to make decisions about surveillance and prophylactic options.
文摘Natural space presents a complicated radiation environment containing various energetic particle types at different flux level and the flux of the particles is not constant modulating by solar activities[1]. On the other hand, the heavy ion flux applied in ground based single event test was commonly set at a fixed value. Refs. [2] and [3] both pointed out that the single event test result of harden device may exhibit flux dependency. It is necessary to fully study the ion flux dependency on single event effect.
文摘To evaluate the safety of detergents,the toxicological test results of 580 collected detergents were analyzed.The results showed that,in the acute oral toxicity test,94.4%and 5.6%of the samples were classified as non-toxic and toxic respectively.In skin irritation test,95.1%of the samples were mild irritation or below,and 4.9%were moderate irritation or above.In the vaginal mucosa irritation test,79.0%of the samples were very mild irritation or below,while 21.0%were mild irritation or above.In the acute inhalation toxicity test,the proportion of the samples classified as actually non-toxic and toxic were 87.9%and 12.1%respectively.In the eye irritation test,95.7%of the samples belonged to mild irritation or below,and 4.3%of the samples belonged to moderate irritation or above.The products at risk in category A,B and C products account for 6.3%,7.7%and 14.2%respectively.Of the 580 tested samples,90.9%were relatively safe,while 9.1%were at risk.These data showed that most of the tested samples meet the safety requirements for use.
文摘Objective To investigate cumulative results of chemosensitivity test using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl (MTT) assay in double-layer agarose. Methods A total of 2 491 patients with different kinds of cancers were enrolled in the study, in which 18 kinds of different anticancer drugs were used. A computer soft was used to get charts. ResultsThe total evaluability rate was 82.7% (2 060/2 491). Among all agents, the efficiency rates of 5-Fu, MMC, DDP, BLM and CBP were higher than the efficiency rates of others. The response rate range of different cancer in vitro sensitivity by using MTT assay in double layer agarose were from 9.2% (biliary duct) to 37.5% (malignant lymphoma). For colon and rectum cancer, 5-Fu, DDP, MMC and BLM were more sensitive than other anti-tumor agents. For breast carcinomas, ACTD and DDP were more sensitive. For gastric cancer, 5-Fu, DDP and BLM were more sensitive. For leukemia, VM-26 and HHRT were more sensitive. ACM was more sensitive to kidney and MXT and BLM were more sensitive to pancreas cancer. For Lung cancer, DDP and EPI were more sensitive. Mean true positive rate, mean true negative rate, mean sensitivity, mean specificity and mean accuracy were 44% , 92% , 72% , 77% , and 76% , respectively. Conclusion Chemosensitivity tesing using the MTT assay in a double layer agarose was a very useful reference to chem- therapy.
文摘To make oral test accurately reflect the actual English spoken ability of candidates and play its role in guiding and promoting the improvement of English learners in the teaching, we must ensure that the design of scientific questions, the feasibility and validity of judgments to make an accurate and fair measurement of testers' language ability.
文摘AIM To assess the diagnostic accuracy of a new fecal test for detecting Helicobacter pylori(H. pylori), using ^(13)Curea breath test as the reference standard, and explore bacterial antibiotic resistance. METHODS We conducted a prospective two-center diagnostic test accuracy study. We enrolled consecutive people≥ 18 years without previous diagnosis of H. pylori infection, referred for dyspepsia between February and October 2017. At enrollment, all participants underwent 13 C-urea breath test. Participants aged over 50 years were scheduled to undergo upper endoscopy with histology. Participants collected stool samples 1-3 d after enrollment for a new fecal investigation(THD fecal test). The detection of bacterial 23 S rRNA subunit gene indicated H. pylori infection. We also used the index diagnostic test to examine mutations conferring resistance to clarithromycin and levofloxacin. Independent investigators analyzed index test and reference test standard results blinded to the other test findings. We estimated sensitivity, specificity, positive(PPV) and negative(NPV) predictive value, diagnostic accuracy, positive and negative likelihood ratio(LR), together with 95% confidence intervals(CI).RESULTS We enrolled 294 consecutive participants(age: Median 37.0 years, IQR: 29.0-46.0 years; men: 39.8%). Ninetyfive(32.3%) participants had a positive ^(13)C-urea breath test. Twenty-three(7.8%) participants underwent upper endoscopy with histology, with a full concordance between ^(13)C-urea breath test and histology in detecting H. pylori infection. Four(1.4%) out of the 294 participants withdrew from the study after the enrollment visit and did not undergo THD fecal testing. In the 290 participants who completed the study, the THD fecal test sensitivity was 90.2%(CI: 84.2%-96.3%), specificity 98.5%(CI:96.8%-100%), PPV 96.5%(CI: 92.6%-100%), NPV 95.6%(CI: 92.8%-98.4%), accuracy 95.9%(CI: 93.6%-98.2%), positive LR 59.5(CI: 19.3-183.4), negative LR 0.10(CI: 0.05-0.18). Out of 83 infected participants identified with the THD fecal test, 34(41.0%) had bacterial genotypic changes consistent with antibiotic-resistant H. pylori infection. Of these, 27(32.5%) had bacterial strains resistant to clarithromycin, 3(3.6%) to levofloxacin, and 4(4.8%) to both antibiotics. CONCLUSION The THD fecal test has high performance for the non-invasive diagnosis of H. pylori infection while additionally enabling the assessment of bacterial antibiotic resistances.
文摘AIM:To study intestinal permeability(IP) and its relationship to the disease activity in patients with inflammatory bowel diseases(IBD)-Crohn's disease(CD) and ulcerative colitis(UC).METHODS:Fifty-eight patients with active IBD(32 with CD and 26 with UC) and 25 healthy controls consented to participate in the study.The clinical activity of CD was estimated using the Crohn's Disease Activity Index(CDAI),and the endoscopic activity of UC using the Mayo scoring system.IP was assessed by the rise in levels of iohexol,which was administered orally(25 mL,350 mg/mL) 2 h after breakfast.Three and six hours later serum(SIC mg/L) and urine(UIC g/mol) iohexol concentrations were determined by a validated HPLC-UV technique.RESULTS:In the CD group,SIC values at 3 h(2.95 ± 2.11 mg/L) and at 6 h after ingestion(2.63 ± 2.18 mg/L) were significantly higher compared to those of healthy subjects(1.25 ± 1.40 mg/L and 1.11 ± 1.10 mg/L,respectively,P < 0.05).UIC(g/mol) values were also higher in patients,but the differences were significant only for UIC at 6 h.Significant positive correlation(P < 0.05) was found between the CDAI and IP,assessed by SIC at 3 h(r = 0.60) and 6 h(r = 0.74) after the ingestion.In comparison to controls,SIC and UIC of UC patients were higher in the two studied periods,but the differences were significant at 6 h only.Significantly higher values of SIC(P < 0.05) were found in patients with severe endoscopic activity of UC compared to those of patients with mild and moderate activity(3.68 ± 3.18 vs 0.92 ± 0.69 mg/L).CONCLUSION:Serum levels of iohexol at 3 h and 6 h after its ingestion reflect increased IP,which is related to the disease activity in patients with IBD.
基金supported by National Natural Science Foundation of China (Grant No. 50535030)National Basic Research Program of China (973 Program, Grant No. 2006CB300407)
文摘Mechanical properties of structural materials are particularly important for design, performance realization and reliability analysis of microelectromechanical systems (MEMS). Furthermore, accurate database of mechanical properties at the micro scale can provide indispensable reference for establishing MEMS standard. Electroplated nickel film is one of the most favored structural materials used in MEMS, thus its mechanical properties has been studied for many years. However, the measured values show large scatter in Yotmg's modulus of nickel film. Young's modulus and yield stress of electroplated nickel film are measured by using a micro-tensile testing instrument. The tensile load applied on the specimen is measured by a load cell with accuracy 0.25 mN directly, without additional friction. Through measuring the axial stiffness coefficient of the tensile instnunent in situ, the tensile strain of the specimen is obtained by using two-serial spring model. The electroplated nickel films were fabricated from sulfarnate baths, and the gauge section is 500μm long and 10μm wide nominally, and thickness range between 25 μm and 50μm. The obtained Young's modulus from tensile testing is 83+6 GPa for nickel specimens electroplated at current density of 20 mA/cm2 and it increases to 124+5 GPa as current density is decreased to 10 mA/cm2. The phenomena are interpreted in terms of porosity of microstructure. The higher current density produced rnicrostucture with low density and high volume fraction of pores, and the microstructure of high porosity corresponds to a lower modulus. The measured values of Young's modulus are consistent with those of calculated from the exponential empirical formula between Young's modulus and porosity. The micro-tensile testing instrument can also be used for mechanical measurement of other MEMS films.
基金National Natural Science Foundation of China Under Grant No.59778027State Key Laboratory of Coastal Offshore EngineeringDalian University of Technology Under Grant No.9702
文摘The success of the tuned mass damper (TMD) in reducing wind-induced structural vibrations has been well established. However, from most of the recent numerical studies, it appears that for a structure situated on very soft soil, soil-structure interaction (SSI) could render a damper on the structure totally ineffective. In order to experimentally verify the SSI effect on the seismic performance of TMD, a series of shaking table model tests have been conducted and the results are presented in this paper. It has been shown that the TMD is not as effective in controlling the seismic responses of structures built on soft soil sites due to the SSI effect. Some test results also show that a TMD device might have a negative impact if the SSI effect is neglected and the structure is built on a soft soil site. For structures constructed on a soil foundation, this research verifies that the SSI effect must be carefully understood before a TMD control system is designed to determine if the control is necessary and if the SSI effect must be considered when choosing the optimal parameters of the TMD device.
文摘BACKGROUND 1,3-beta-D-glucan(BG)is a ubiquitous cell wall component of gut microorganisms.We hypothesized that the serum levels of BG could reflect active intestinal inflammation in patients with inflammatory bowel disease.AIM To determine whether the serum BG concentrations correlate with intestinal inflammation.METHODS A prospective observational study was performed in a tertiary referral center,from 2016 to 2019,in which serum BG was determined in 115 patients with Crohn’s disease(CD),51 with ulcerative colitis(UC),and 82 controls using a photometric detection kit.Inflammatory activity was determined by ileocolonoscopy,histopathology,magnetic resonance enterography,and biomarkers,including fecal calprotectin(FC),C-reactive protein,and a panel of cytokines.The ability of BG to detect active vs inactive disease was assessed using the area under the receiver operating characteristic curve.In subgroup analysis,serial BG was used to assess the response to therapeutic interventions.RESULTS The serum BG levels were higher in CD patients than in controls(P=0.0001).The BG levels paralleled the endoscopic activity in CD patients and histologic activity and combined endoscopic and histologic activity in both CD and UC patients.The area under the curve(AUC)in receiver operating characteristic analysis to predict endoscopic activity was 0.694[95%confidence interval(CI):0.60-0.79;P=0.001]in CD,and 0.662(95%CI:0.51-0.81;P=0.066)in UC patients.The AUC in receiver operating characteristic analysis to predict histologic activity was 0.860(95%CI:0.77-0.95;P<0.001)in CD,and 0.786(95%CI:0.57-0.99;P=0.015)in UC patients.The cut-off values of BG for both endoscopic and histologic activity were 60μg/mL in CD,and 40μg/mL in UC patients.Performance analysis showed that the results based on BG of 40 and 60μg/mL were more specific for predicting endoscopic activity(71.8%and 87.2%for CD;and 87.5%and 87.5%for UC,respectively)than FC(53.3%and 66.7%for CD;and 20%and 80%for UC,respectively);and also histologic activity(60.5%and 76.3%for CD;and 90.0%and 95.0%for UC,respectively)than FC(41.7%and 50.0%for CD;and 25%and 50%for UC,respectively).Regarding the clinical,endoscopic,and histologic activities,the BG levels were reduced following therapeutic intervention in patients with CD(P<0.0001)and UC(P=0.003).Compared with endoscopic(AUC:0.693;P=0.002)and histologic(AUC:0.868;P<0.001)activity,no significant correlation was found between serum BG and transmural healing based on magnetic resonance enterography(AUC:0.576;P=0.192).Positive correlations were detected between BG and IL-17 in the CD(r:0.737;P=0.001)and the UC group(r:0.574;P=0.005),and between BG and interferon-gamma in the CD group(r:0.597;P=0.015).CONCLUSION Serum BG may represent an important novel noninvasive approach for detecting mucosal inflammation and therapeutically monitoring inflammatory bowel diseases,particularly in CD.
文摘The stress on a test specimen during tensile testing is generally measured by a strain gauge. This method has some problems in that it would influence the measurement conditions of the tensile test and can evaluate only the position at which the strain gauge is attached. The acoustoelastic method is proposed as a method replacing the strain gauge method. However, an ultrasonic sensor with a piezoelectric oscillator requires a coupling medium to inject an ultrasonic wave into a solid material. This condition, due to the error factor of the stress measurement, makes it difficult for the ultrasonic sensor to move on the specimen. We then tried to develop a non-contact stress measurement system during tensile testing using an electromagnetic acoustic transducer (EMAT) with an SH0-plate wave and S0-Lamb wave. The EMAT can measure the propagation time in which the ultrasonic wave travels between a receiver and a transmitter without a coupling medium during the tensile testing and can move easily. The interval between the transmitter and the receiver is 10mm and can be moved along the parallel direction or the vertical direction of the tensile load. The transit time was measured by a cross-correlation method and converted into the stress on the test specimen using the acoustoelastic method. We confirmed that the stress measurement using an SH0-plate wave was superior to that with an S0-Lamb wave.
基金Project(51578272)supported by the National Natural Science Foundation of China
文摘Calcined ginger nuts admixed by fly ash and quartz sand (CGN-(F+S)) has been validated to be basically compatible to earthen sites as an anchor grout. Accelerated ageing tests including water stability test, temperature and humidity cycling test, soundness test and alkali resistance test are conducted with the objective to further research the property changes of CGN-(F+S) grout. Density, surface hardness, water penetration capacity, water permeability capacity, soluble salt, scanning electron microscopy (SEM) images and energy dispersive spectrometry (EDS) spectrum of these samples have been tested after accelerated ageing tests. The results show that densities of samples decrease, surface hardness, water penetration capacity and water permeability capacity of samples increase generally. Besides, soluble salt analysis, SEM and EDS results well corroborate the changes. Based on the results it can be concluded that property changes are most serious after temperature and humidity cycling test, followed by water stability, soundness and alkali resistance test in sequence. But in general, CGN-(F+S) still has good durability.
基金supports from National Natural Science Foundation of China (Nos.50775183 and 50805118)Research Fund for Doctoral Programof higher Education (N6CJ0001)National High Technical Research and Development Programme of China (No.2009AA04Z418)
文摘The flat cylindrical indentation tests with different sizes of punch radius were investigated using finite element method (FEM) aimed to reveal the effect of punch size on the indentation behavior of the film/substrate system. Based on the FEM results analysis, two methods was proposed to separate film's reduced Young's modulus from a film/substrate system. The first method was based on a new weight function that quantifies film's and substrate's contributions to the overall mechanical properties of the film/substrate system in the flat cylindrical indentation test. The second method, a numerical approach, including fitting and extrapolation procedures was put forward. Both of the results from the two methods showed a reasonable agreement with the one input FE model. At last, the effect of maximum indentation depth and the surface micro-roughness of the thin film on the reduced Young's modulus of the film/substrate system were discussed. The methods proposed in the present study provide some new conceptions on evaluating other properties of thin films, e.g. creep, for which a flat-ended punch is also employed.
文摘This paper derives the variance of the information content and develops its statistical inference method. We describe the relations between information content and sensitivity, specificity, efficiency, prevalence rate. If sensitivity, specificity and efficiency are fixed, the closer to 0. 5 the prevalence rate is, the more the information content. If prevalence rate and efficiency are fixed, the closer to each other the sensitivity and specificity are, the more the information content. We compare the power of information content method, efficiecy test, Youden's index test and kappa coefficient method. The information content method has higher power than the other methods in most conditions. It is especially sensitive to the difference between two sensitivities. It comes to conclusion that the information content method has more virtues than the other methods mentioned in this paper.
基金funding this work through the Research Groups Program under Grant Number R.G.P.2/68/41.I.A.
文摘In this paper,we considered the Length-biased weighted Lomax distribution and constructed new acceptance sampling plans(ASPs)where the life test is assumed to be truncated at a pre-assigned time.For the new suggested ASPs,the tables of the minimum samples sizes needed to assert a specific mean life of the test units are obtained.In addition,the values of the corresponding operating characteristic function and the associated producer’s risks are calculated.Analyses of two real data sets are presented to investigate the applicability of the proposed acceptance sampling plans;one data set contains the first failure of 20 small electric carts,and the other data set contains the failure times of the air conditioning system of an airplane.Comparisons are made between the proposed acceptance sampling plans and some existing acceptance sampling plans considered in this study based on the minimum sample sizes.It is observed that the samples sizes based on the proposed acceptance sampling plans are less than their competitors considered in this study.The suggested acceptance sampling plans are recommended for practitioners in the field.