This article presents a comprehensive review for the dilemma of reactive power flow, while addressing different proposed remedy strategies: conventional and most update solutions. Robust analytical expressions were ut...This article presents a comprehensive review for the dilemma of reactive power flow, while addressing different proposed remedy strategies: conventional and most update solutions. Robust analytical expressions were utilized to exploit the functionality of the proposed solutions and to show clearly the relation between the reactive power and control variables. The article, moreover, proposes a simple, innovative and robust analysis for static performance of the STATCOM. This approach shows clearly the advantages of the STA-TCOM in regulating reactive power and maintaining load voltage level within presumable limits. The approach, furthermore, reveals explicitly via analytical expressions the impact of the STATCOM operation on different aspects of the power system under concern.展开更多
When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensat...When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensate reactive power following value U* according to the requirements of the Vietnamese power system dispath center, flit harmonic by passive filter... However, it still has some disadvantages of this substation that need to be overcome: use large number of main devices, generate harmonics by itself, cause a lot of active power losses. Thus, the authors have an idea to solve these problems by applying a bidirectional power converter with having difference circuit structure and PWM (pulse width modulation) controller with SVM (space vector modulation) pulse generated section, so compensative current which is created by inductance element can be reserved, adjust continuos and always has full sinusoidal form, not generating harmonic. The benefit of this new solution is to eliminate the three above fundamental disadvantages. This new model is built based on authors' research about BESS (battery energy storage system). The research results have been verified by simulations in Matlab/Simulink software.展开更多
文摘This article presents a comprehensive review for the dilemma of reactive power flow, while addressing different proposed remedy strategies: conventional and most update solutions. Robust analytical expressions were utilized to exploit the functionality of the proposed solutions and to show clearly the relation between the reactive power and control variables. The article, moreover, proposes a simple, innovative and robust analysis for static performance of the STATCOM. This approach shows clearly the advantages of the STA-TCOM in regulating reactive power and maintaining load voltage level within presumable limits. The approach, furthermore, reveals explicitly via analytical expressions the impact of the STATCOM operation on different aspects of the power system under concern.
文摘When the authors research on the fact that some SVC (static var compensator) substations connected at some buses in power system, they realized that some main functions ensured to operate well. Those are: compensate reactive power following value U* according to the requirements of the Vietnamese power system dispath center, flit harmonic by passive filter... However, it still has some disadvantages of this substation that need to be overcome: use large number of main devices, generate harmonics by itself, cause a lot of active power losses. Thus, the authors have an idea to solve these problems by applying a bidirectional power converter with having difference circuit structure and PWM (pulse width modulation) controller with SVM (space vector modulation) pulse generated section, so compensative current which is created by inductance element can be reserved, adjust continuos and always has full sinusoidal form, not generating harmonic. The benefit of this new solution is to eliminate the three above fundamental disadvantages. This new model is built based on authors' research about BESS (battery energy storage system). The research results have been verified by simulations in Matlab/Simulink software.