A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for th...A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for the prediction of the neutral-point current. A quality function was found to balance the neutral-point, and a metabolic on-times distribution factor was used as a predicator to minimize the quality function at each switching state. Simulation results show that the proposed method produces smaller ripples in tested signals compared with the established one, namely, 9.15% less in a total harmonic distortion(THD) of line-to-line voltage, 1.08% less in the THD of phase current, and 0.9 V less in the ripple of the neutral-point voltage. The obtained experimental results show that the main harmonics of the line-to-line voltage and the phase current in the proposed method are improved by 10 d B and 6 d B, respectively, and the ripple of neutral-point voltage is halved compared to the established one.展开更多
In this short article, we have studied the controllability result for neutral impulsive differential inclusions with nonlocal conditions by using the fixed point theorem for condensing multi-valued map due to Martelli...In this short article, we have studied the controllability result for neutral impulsive differential inclusions with nonlocal conditions by using the fixed point theorem for condensing multi-valued map due to Martelli [1]. The system considered here follows the P.D.E involving spatial partial derivatives with α-norms.展开更多
The four-level active neutral point clamped(ANPC)inverter has become increasingly widely used in the renewable energy indus-try since it offers one more voltage level without increasing the total number of active swit...The four-level active neutral point clamped(ANPC)inverter has become increasingly widely used in the renewable energy indus-try since it offers one more voltage level without increasing the total number of active switches compared to the three-level ANPC inverter.The model predictive current control(MPCC)is a promising control method for multi-level inverters.However,the conven-tional MPCC suffers from high computational complexity and tedious weighting factor tuning in multi-level inverter applications.A low-complexity MPCC without weighting factors for a four-level ANPC inverter is proposed in this paper.The computational burden and voltage vector candidate set are reduced according to the relationship between voltage vector and neutral point voltage balance.The proposed MPCC shows excellent steady-state and dynamics performances while ensuring the neutral point voltage balancing.The efficacy of the proposed MPCC is verified by simulation and experimental results.展开更多
An analytical evaluation method for output waveform quality of space vector pulse width modulation(PWM)strategies applied in neutral⁃point⁃clamped three⁃level converter(3L⁃NPC)is proposed in this paper.Low frequency e...An analytical evaluation method for output waveform quality of space vector pulse width modulation(PWM)strategies applied in neutral⁃point⁃clamped three⁃level converter(3L⁃NPC)is proposed in this paper.Low frequency error caused by neutral point voltage ripple and high frequency error introduced by space vector synthesis were both taken into account,and the unified error model of output current ripple was established.By taking continuous and discontinuous modulation strategies as examples,the unified error model was validated through Fourier analysis of the experimental results.The proposed evaluation method will be helpful for the switching sequence optimization and the modulation strategy selection.展开更多
To maximize conversion efficiency,photovoltaic(PV)systems generally operate in the maximum power point tracking(MPPT)mode.However,due to the increasing penetra tion level of PV systems,there is a need for more develop...To maximize conversion efficiency,photovoltaic(PV)systems generally operate in the maximum power point tracking(MPPT)mode.However,due to the increasing penetra tion level of PV systems,there is a need for more developed control functions in terms of frequency support services and voltage control to maintain the reliability and stability of the power grid.Therefore,flexible active power control is a manda tory task for grid-connected PV systems to meet part of the grid requirements.Hence,a significant number of flexible pow er point tracking(FPPT)algorithms have been introduced in the existing literature.The purpose of such algorithms is to real ize a cost-effective method to provide grid support functional ities while minimizing the reliance on energy storage systems.This paper provides a comprehensive overview of grid support functionalities that can be obtained with the FPPT control of PV systems such as frequency support and volt-var control.Each of these grid support functionalities necessitates PV sys tems to operate under one of the three control strategies,which can be provided with FPPT algorithms.The three control strate gies are classified as:①constant power generation control(CP GC),②power reserve control(PRC),and③power ramp rate control(PRRC).A detailed discussion on available FPPT algo rithms for each control strategy is also provided.This paper can serve as a comprehensive review of the state-of-the-art FPPT algorithms that can equip PV systems with various grid support functionalities.展开更多
This paper proposes a novel SVPWM (space vector pulse width modulation) strategy for the three-level neutral-point-clamped voltage source inverter, based on the particular disposition of all the redundant voltage ve...This paper proposes a novel SVPWM (space vector pulse width modulation) strategy for the three-level neutral-point-clamped voltage source inverter, based on the particular disposition of all the redundant voltage vectors. The new modulation approach shows superior performance for harmonic voltage and balancing control of neutral-point potential compared to the popular eight-stage centered SVPWM. It realizes suppression of inverter neutral-point potential variation by accurately modifying redundant factor of small vectors pairs, only requiring information of DC-link capacitor voltages and three-phase load currents. This is convenient to apply and is compatible of digital computer realization. Feasibility of the proposed control approach is verified by simulation and experimental results.展开更多
In this paper, we establish sufficient conditions for existence and controllability of nonlinear neutral evolution integroditferential systems in Banach spaces. The result is obtained by using the resolvent operators ...In this paper, we establish sufficient conditions for existence and controllability of nonlinear neutral evolution integroditferential systems in Banach spaces. The result is obtained by using the resolvent operators and fixed point analysis approach.展开更多
A new modulation approach was presented for the control of neutral-point (NP) voltage variation in the three-level NP-clamped voltage source inverter, and the average NP current model was established based on vector d...A new modulation approach was presented for the control of neutral-point (NP) voltage variation in the three-level NP-clamped voltage source inverter, and the average NP current model was established based on vector diagram partition. Thus, theory base was built for balancing control of NP potential. Theoretical analysis and experimental results indicate that the proposed method for NP balancing control vector synthe- sizing concept based can make the average NP current zero, and do not inffuence NP potential within every sample period. The effectiveness of proposed research approach was verified by simulative and experimental results.展开更多
高速磁浮交通牵引变流器采用24 MVA背靠背三电平有源中点钳位拓扑,其中两台整流器和两台逆变器共用直流母线。该文分析整流侧和逆变侧在不同功率因数下中点电压(neutral point voltage,NPV)偏移机理及不同电压矢量对NPV的具体影响。据此...高速磁浮交通牵引变流器采用24 MVA背靠背三电平有源中点钳位拓扑,其中两台整流器和两台逆变器共用直流母线。该文分析整流侧和逆变侧在不同功率因数下中点电压(neutral point voltage,NPV)偏移机理及不同电压矢量对NPV的具体影响。据此,针对高速磁浮逆变器并联和串联两种模式,建立NPV偏移模型,得到在调制比和功率因数同时变化时NPV的可控区域。为在全速范围保证NPV平衡,提出一种基于平移调制波的协同控制策略。为减轻整流器功率因数和调制比对NPV的影响,采用一种具有相电压半波对称性的载波脉宽调制,并证明其具备NPV自平衡能力。仿真和硬件在环实验表明,所提策略具有NPV恢复到平衡状态所需时间短、可控范围大等优点,可在高速磁浮全速工况下保证NPV平衡。展开更多
以三相Vienna整流器为研究对象,针对有限集模型预测控制FCS-MPC(finite control set model predictive control)实现中点电位平衡控制时权重因子选取困难,采样周期内作用单一矢量引起网侧电流纹波较大的问题,提出一种基于双矢量的无权...以三相Vienna整流器为研究对象,针对有限集模型预测控制FCS-MPC(finite control set model predictive control)实现中点电位平衡控制时权重因子选取困难,采样周期内作用单一矢量引起网侧电流纹波较大的问题,提出一种基于双矢量的无权重型模型预测控制UF-MPC(unweighted factor model predictive control)策略。首先,构建基于功率预测的单目标价值函数。然后,通过扇区划分同时采用无权重因子的方式来提高单次寻优效率,根据直流侧中点电位的波动优选冗余小矢量,实现无权重因子的中点电位平衡控制。在获取最优矢量的基础上,结合零矢量实现了双矢量固定开关频率控制。最后,基于RT-LAB半实物平台从稳态、暂态、中点电位波动方面进行验证,有效证明了所提控制策略的正确性和有效性。展开更多
基金Project(61074018)supported by the National Natural Science Foundation of ChinaProject(2012kfjj06)supported by Hunan Province Key Laboratory of Smart Grids Operation and Control(Changsha University of Science and Technology),China
文摘A comprehensive predictive strategy was proposed for the neutral-point balancing control of back-to-back three-level converters. The phase currents at both sides and the DC-link capacitor voltages were measured for the prediction of the neutral-point current. A quality function was found to balance the neutral-point, and a metabolic on-times distribution factor was used as a predicator to minimize the quality function at each switching state. Simulation results show that the proposed method produces smaller ripples in tested signals compared with the established one, namely, 9.15% less in a total harmonic distortion(THD) of line-to-line voltage, 1.08% less in the THD of phase current, and 0.9 V less in the ripple of the neutral-point voltage. The obtained experimental results show that the main harmonics of the line-to-line voltage and the phase current in the proposed method are improved by 10 d B and 6 d B, respectively, and the ripple of neutral-point voltage is halved compared to the established one.
文摘In this short article, we have studied the controllability result for neutral impulsive differential inclusions with nonlocal conditions by using the fixed point theorem for condensing multi-valued map due to Martelli [1]. The system considered here follows the P.D.E involving spatial partial derivatives with α-norms.
基金supported by the National Key Research and Development Program of China(Grant No.2022YFB4201602)the National Natural Science Foundation of China(Grant No.52002409).
文摘The four-level active neutral point clamped(ANPC)inverter has become increasingly widely used in the renewable energy indus-try since it offers one more voltage level without increasing the total number of active switches compared to the three-level ANPC inverter.The model predictive current control(MPCC)is a promising control method for multi-level inverters.However,the conven-tional MPCC suffers from high computational complexity and tedious weighting factor tuning in multi-level inverter applications.A low-complexity MPCC without weighting factors for a four-level ANPC inverter is proposed in this paper.The computational burden and voltage vector candidate set are reduced according to the relationship between voltage vector and neutral point voltage balance.The proposed MPCC shows excellent steady-state and dynamics performances while ensuring the neutral point voltage balancing.The efficacy of the proposed MPCC is verified by simulation and experimental results.
基金National Natural Science Foundation of China(Grant Nos.51807140 and 51690183).
文摘An analytical evaluation method for output waveform quality of space vector pulse width modulation(PWM)strategies applied in neutral⁃point⁃clamped three⁃level converter(3L⁃NPC)is proposed in this paper.Low frequency error caused by neutral point voltage ripple and high frequency error introduced by space vector synthesis were both taken into account,and the unified error model of output current ripple was established.By taking continuous and discontinuous modulation strategies as examples,the unified error model was validated through Fourier analysis of the experimental results.The proposed evaluation method will be helpful for the switching sequence optimization and the modulation strategy selection.
基金supported in part by the Future Battery Industries Cooperative Research Center(www.fbicrc.com.au)as part of the Australian Government’s CRC Program(www.business.gov.au),which supports industry-led collaborations between industry,researchers and the community.
文摘To maximize conversion efficiency,photovoltaic(PV)systems generally operate in the maximum power point tracking(MPPT)mode.However,due to the increasing penetra tion level of PV systems,there is a need for more developed control functions in terms of frequency support services and voltage control to maintain the reliability and stability of the power grid.Therefore,flexible active power control is a manda tory task for grid-connected PV systems to meet part of the grid requirements.Hence,a significant number of flexible pow er point tracking(FPPT)algorithms have been introduced in the existing literature.The purpose of such algorithms is to real ize a cost-effective method to provide grid support functional ities while minimizing the reliance on energy storage systems.This paper provides a comprehensive overview of grid support functionalities that can be obtained with the FPPT control of PV systems such as frequency support and volt-var control.Each of these grid support functionalities necessitates PV sys tems to operate under one of the three control strategies,which can be provided with FPPT algorithms.The three control strate gies are classified as:①constant power generation control(CP GC),②power reserve control(PRC),and③power ramp rate control(PRRC).A detailed discussion on available FPPT algo rithms for each control strategy is also provided.This paper can serve as a comprehensive review of the state-of-the-art FPPT algorithms that can equip PV systems with various grid support functionalities.
文摘This paper proposes a novel SVPWM (space vector pulse width modulation) strategy for the three-level neutral-point-clamped voltage source inverter, based on the particular disposition of all the redundant voltage vectors. The new modulation approach shows superior performance for harmonic voltage and balancing control of neutral-point potential compared to the popular eight-stage centered SVPWM. It realizes suppression of inverter neutral-point potential variation by accurately modifying redundant factor of small vectors pairs, only requiring information of DC-link capacitor voltages and three-phase load currents. This is convenient to apply and is compatible of digital computer realization. Feasibility of the proposed control approach is verified by simulation and experimental results.
文摘In this paper, we establish sufficient conditions for existence and controllability of nonlinear neutral evolution integroditferential systems in Banach spaces. The result is obtained by using the resolvent operators and fixed point analysis approach.
文摘A new modulation approach was presented for the control of neutral-point (NP) voltage variation in the three-level NP-clamped voltage source inverter, and the average NP current model was established based on vector diagram partition. Thus, theory base was built for balancing control of NP potential. Theoretical analysis and experimental results indicate that the proposed method for NP balancing control vector synthe- sizing concept based can make the average NP current zero, and do not inffuence NP potential within every sample period. The effectiveness of proposed research approach was verified by simulative and experimental results.
文摘高速磁浮交通牵引变流器采用24 MVA背靠背三电平有源中点钳位拓扑,其中两台整流器和两台逆变器共用直流母线。该文分析整流侧和逆变侧在不同功率因数下中点电压(neutral point voltage,NPV)偏移机理及不同电压矢量对NPV的具体影响。据此,针对高速磁浮逆变器并联和串联两种模式,建立NPV偏移模型,得到在调制比和功率因数同时变化时NPV的可控区域。为在全速范围保证NPV平衡,提出一种基于平移调制波的协同控制策略。为减轻整流器功率因数和调制比对NPV的影响,采用一种具有相电压半波对称性的载波脉宽调制,并证明其具备NPV自平衡能力。仿真和硬件在环实验表明,所提策略具有NPV恢复到平衡状态所需时间短、可控范围大等优点,可在高速磁浮全速工况下保证NPV平衡。
文摘以三相Vienna整流器为研究对象,针对有限集模型预测控制FCS-MPC(finite control set model predictive control)实现中点电位平衡控制时权重因子选取困难,采样周期内作用单一矢量引起网侧电流纹波较大的问题,提出一种基于双矢量的无权重型模型预测控制UF-MPC(unweighted factor model predictive control)策略。首先,构建基于功率预测的单目标价值函数。然后,通过扇区划分同时采用无权重因子的方式来提高单次寻优效率,根据直流侧中点电位的波动优选冗余小矢量,实现无权重因子的中点电位平衡控制。在获取最优矢量的基础上,结合零矢量实现了双矢量固定开关频率控制。最后,基于RT-LAB半实物平台从稳态、暂态、中点电位波动方面进行验证,有效证明了所提控制策略的正确性和有效性。