期刊文献+
共找到7,312篇文章
< 1 2 250 >
每页显示 20 50 100
Primary frequency control considering communication delay for grid-connected offshore wind power systems
1
作者 Xueping Pan Qijie Xu +5 位作者 Tao Xu Jinpeng Guo Xiaorong Sun Yuquan Chen Qiang Li Wei Liang 《Global Energy Interconnection》 EI CSCD 2024年第3期241-253,共13页
Offshore wind farms are becoming increasingly distant from onshore centralized control centers,and the communication delays between them inevitably introduce time delays in the measurement signal of the primary freque... Offshore wind farms are becoming increasingly distant from onshore centralized control centers,and the communication delays between them inevitably introduce time delays in the measurement signal of the primary frequency control.This causes a deterioration in the performance of the primary frequency control and,in some cases,may even result in frequency instability within the power system.Therefore,a frequency response model that incorporates communication delays was established for power systems that integrate offshore wind power.The Padéapproximation was used to model the time delays,and a linearized frequency response model of the power system was derived to investigate the frequency stability under different time delays.The influences of the wind power proportion and frequency control parameters on the system frequency stability were explored.In addition,a Smith delay compensation control strategy was devised to mitigate the effects of communication delays on the system frequency dynamics.Finally,a power system incorporating offshore wind power was constructed using the MATLAB/Simulink platform.The simulation results demonstrate the effectiveness and robustness of the proposed delay compensation control strategy. 展开更多
关键词 offshore wind power Primary frequency control Time delay Padéapproximation Time-delay compensation control
下载PDF
Design to conditioning circuits of dynamic compensation of reactive power in the intelligence voltage controller
2
作者 Yong-qin WEI,Yin-jing GUO (College of Infor.&Elec.Eng,Shan dong university of science of technology,Qingdao266510,china) 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期111-113,共3页
The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easi... The paper introduces one design idea that making use of SCM to control Real-timely the dynamic compensation of reactive power.Firstly,design one Circuit to Sample the voltage and current,and by these datas we can easily calculate the power factor,and Voltage controller in the microcontroller to determine whether input the compensation capacitance according to the size of power factor,the paper also analyzes the principle of capacitance compensation and calculation method. Dynamic compensation for the entire process is quick and accurate. 展开更多
关键词 reactive power compensation Real-timely control DYNAMIC power factor
下载PDF
The design and simulation of TCR(thyristor control reactor) reactive power compensation system based on Arene
3
作者 王淑芳 张丽 +1 位作者 姜建国 王汝琳 《Journal of Coal Science & Engineering(China)》 2004年第2期101-104,共4页
Inevitably, the question of reactive power compensation was aroused by applied of power electronics. Based on the study of the instantaneous reactive power theory, the designs of TCR(thyristor control reactor) thyrist... Inevitably, the question of reactive power compensation was aroused by applied of power electronics. Based on the study of the instantaneous reactive power theory, the designs of TCR(thyristor control reactor) thyristor control reactor reac- tive power compensation system and TCR single closed loop strategy was pro- posed. In addition, as digital simulation software, Arene was applied to simulate the Jining coal mine No.2 system. The simulation results validate that the design is effective to improve power factor and stabilization of the system. 展开更多
关键词 TCR reactive power compensation instantaneous reactive power
下载PDF
Effectiveness of Optimal Arrangement of the Residences Operated by Reactive Power Control for a Clustered Grid-Interconnected PV System
4
作者 Yusuke Miyamoto Yasuhiro Hayashi 《Journal of Energy and Power Engineering》 2013年第7期1415-1422,共8页
There is a danger of power generation efficiency decreasing due to voltage increase when clustered residential PV systems are grid-interconnected to a single distribution line. As a countermeasure, installation of the... There is a danger of power generation efficiency decreasing due to voltage increase when clustered residential PV systems are grid-interconnected to a single distribution line. As a countermeasure, installation of the reactive power control of an inverter at each residence has been considered. However, there are not many types of inverters that can operate reactive power control because there are insufficient effects on a low voltage distribution line with low penetration PV with reactive power control. Therefore, it is necessary to consider how to increase generation efficiency with a lower number of inverters. In this paper, four Japanese standard distribution line structures, for example of a residential area on "C1", where 2,160 residential PV systems are grid-interconnected, are selected. The optimal setting of reactive power control at each residence is computed on the distribution lines with a greedy method. 展开更多
关键词 Distribution line grid-interconnection photovoltaic power systems reactive power control voltage increase.
下载PDF
Dispersed Wind Power Planning Method Considering Network Loss Correction with Cold Weather
5
作者 Hanpeng Kou Tianlong Bu +2 位作者 Leer Mao Yihong Jiao Chunming Liu 《Energy Engineering》 EI 2024年第4期1027-1048,共22页
In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is... In order to play a positive role of decentralised wind power on-grid for voltage stability improvement and loss reduction of distribution network,a multi-objective two-stage decentralised wind power planning method is proposed in the paper,which takes into account the network loss correction for the extreme cold region.Firstly,an electro-thermal model is introduced to reflect the effect of temperature on conductor resistance and to correct the results of active network loss calculation;secondly,a two-stage multi-objective two-stage decentralised wind power siting and capacity allocation and reactive voltage optimisation control model is constructed to take account of the network loss correction,and the multi-objective multi-planning model is established in the first stage to consider the whole-life cycle investment cost of WTGs,the system operating cost and the voltage quality of power supply,and the multi-objective planning model is established in the second stage.planning model,and the second stage further develops the reactive voltage control strategy of WTGs on this basis,and obtains the distribution network loss reduction method based on WTG siting and capacity allocation and reactive power control strategy.Finally,the optimal configuration scheme is solved by the manta ray foraging optimisation(MRFO)algorithm,and the loss of each branch line and bus loss of the distribution network before and after the adoption of this loss reduction method is calculated by taking the IEEE33 distribution system as an example,which verifies the practicability and validity of the proposed method,and provides a reference introduction for decision-making for the distributed energy planning of the distribution network. 展开更多
关键词 Decentralised wind power network loss correction siting and capacity determination reactive voltage control two-stage model manta ray foraging optimisation algorithm
下载PDF
Analysis on the Application of Reactive Power Compensation Technology in Electrical Automation 被引量:1
6
作者 Rumin LIU Lingzhi YANG Haiming LIU 《International Journal of Technology Management》 2015年第2期118-121,共4页
This paper introduces in detail the reactive power compensation technology and its characteristics, to reduce the loss of reactive power compensation technology 1N power distribution system and the electrical automati... This paper introduces in detail the reactive power compensation technology and its characteristics, to reduce the loss of reactive power compensation technology 1N power distribution system and the electrical automation, improve the utilization rate, and realize the control of the voltage amplitude in the system network, voltage stability of power distribution system, has carried on the system analysis to reduce failure of the harmonic current to the power supply system and other functions. And the paper in-depth study on the application of reactive power compensation technology in electrical automation from the reactive compensation technology, substation and distribution line reactive power compensation, power users of reactive power compensation and other aspects. 展开更多
关键词 reactive power compensation electrical automation reactive power harmonic elimination
下载PDF
Microcontroller Control of Reactive Power Compensation for Growing Industrial Loads
7
作者 Edwin N. Mbinkar Derek Ajesam Asoh Sulayman Kujabi 《Energy and Power Engineering》 CAS 2022年第9期460-476,共17页
Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving ... Many industrial installations in developing countries start-up as small factories, without regard for the need of compensation of reactive power, leading to significant financial losses in the long term. By improving the power factor, the customer can reduce its power demand and potentially increase efficiency of their equipment. A PIC microcontroller is used to switch capacitor banks to compensate for the reactive power. In order to determine the size of the capacitor bank needed, the microcontroller calculates the phase difference between the voltage and the current. The results obtained based on the lagging power factor for three test loads show an improvement in the power factor from 0.52 to 0.96 under different test load conditions. 展开更多
关键词 power Factor Compensation Capacitor Bank PIC Microcontroller reactive power
下载PDF
Regulation of the Excitation Reactive Power of the Asynchronous Wind Turbine at Variable Speed
8
作者 Taoufik Ouchbel Smail Zouggar +3 位作者 Mohamed Larbi Elhafyani Mohamed Oukili Mohammed Sedik Abdelhamid Rabhi 《Smart Grid and Renewable Energy》 2013年第3期272-280,共9页
This work focuses, initially, on modeling and simulating an isolated wind system in MATLAB/SIMULINK. And in the second part, it presents the simulation results of the wind system to start unloading and in resistive lo... This work focuses, initially, on modeling and simulating an isolated wind system in MATLAB/SIMULINK. And in the second part, it presents the simulation results of the wind system to start unloading and in resistive load, and the third part will discuss the strategy for adjusting the output voltage of the wind system to connect it to a rural operating load. The results show that in a dynamic environment where the wind speed and the load, changes abruptly, the voltage of the output is controlled at the desired value. 展开更多
关键词 RENEWABLE ENERGY WIND ENERGY Modeling control of reactive power
下载PDF
Design and analysis of dual-mode structure repetitive control based hybrid current regulation scheme for active power filters
9
作者 邹志翔 王政 程明 《Journal of Southeast University(English Edition)》 EI CAS 2013年第4期407-413,共7页
An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structu... An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structure repetitive control (DMRC) so that it can offer superior steady-state performance and good transient features. Unlike the conventional schemes, the proposed scheme-based APF can compensate both the odd and the even order harmonics in grid. The detailed design criteria and the stability analysis of the proposed hybrid current controller are presented. Moreover, an improved structure which incorporates the proposed hybrid controller and the resonant controller for tracking specific order harmonics is given. The relationships between the resonant controller and different repetitive control schemes are discussed. Experimental results verify the effectiveness and advantages of the proposed hybrid control scheme. 展开更多
关键词 active power filter dual-mode structure repetitive control (DMRC) current control harmonic compensation resonant controller
下载PDF
Reactive Power Compensation and Harmonic Suppression for Power Supply System of HT-7U Superconductive Tokamak 被引量:1
10
作者 陶骏 刘正之 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第1期629-635,共7页
In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design... In this paper, a strategy for the reactive power compensation and harmonic suppression of the power supply system in HT-7U superconductive Tokamak is proposed. The optimized approach is given in the parameters design for passive filter. Also a controlling method with fast response time and good accuracy is put forward for the compensator, which is more suitable for the dynamic load. 展开更多
关键词 In reactive power Compensation and Harmonic Suppression for power Supply System of HT-7U Superconductive Tokamak APF HT
下载PDF
Minimization of Reactive Power Fluctuation in JT-60SA Magnet Power Supply
11
作者 K. SHIMADA T. TERAKADO +5 位作者 K. YAMAUCHI M. MATSUKAWA O. BAULAIGUE R. COLETTI A. COLETTI L. NOVELLO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第2期184-187,共4页
This paper describes an asymmetric control method for the firing angle and a start/stop timing shift control of four thyristor converters called "Booster PS" to minimize the reactive power fluctuation during plasma ... This paper describes an asymmetric control method for the firing angle and a start/stop timing shift control of four thyristor converters called "Booster PS" to minimize the reactive power fluctuation during plasma initiation in JT-60SA. From the simulation using the "PSCAD/EMTDC" code, it is found that these control methods can drastically reduce the reac- tive power induced by the four units of the "Booster PS". In addition, the voltage fluctuation of the motor-generator connected to the "Booster PS" is expected to be suppressed. This can also contribute to achieve stable control of the JT-60SA magnet power supplies. 展开更多
关键词 JT-60SA power supply poroidal field coil reactive power fluctuation asym-metric control PSCAD/EMTDC
下载PDF
Design and Analysis of the Poloidal Field Grid Power Supply System for the HT-7 Tokamak
12
作者 许留伟 刘小宁 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期3009-3012,共4页
This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field ... This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation. The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings. 展开更多
关键词 poloidal field (PF) grid power supply harmonic and reactive compensation
下载PDF
The Development of Network based Composite Power quality Regulation Device
13
作者 Weiqiang Fan Ying Lei +2 位作者 Jing Zhu Luo Li Shuai Niu 《Energy and Power Engineering》 2013年第4期1215-1220,共6页
First, the paper analyzes the advantages and disadvantages of all kinds of reactive power compensation technology, and then proposes a principle and integrated control strategy of the composite operation of TSC and SV... First, the paper analyzes the advantages and disadvantages of all kinds of reactive power compensation technology, and then proposes a principle and integrated control strategy of the composite operation of TSC and SVG, also the paper designs and develops the main controller of Network based composite power quality regulation device, based on RTDS, the real-time digital simulation model of The Device is established, and finally the prototype of the device is developed with the function of filter and split-phase compensation. The main controller determines the cooperative operation of both TSC and SVG, and the switching strategy of TSC. The simulation result in RTDS can verify the precision of the measure system and the validity of the control logic, the prototype has finished the type test according to the national standard. 展开更多
关键词 NETWORK BASED COMPOSITE power Quality Regulation Device reactive power Compensation Technology RTDS
下载PDF
Fuzzy Decision Method Applied in Action of Reactive Power Compensation Devices in Wind System
14
作者 Xueming Li Li Feng +1 位作者 Yi Tang Yonghua Chen 《Journal of Power and Energy Engineering》 2014年第4期280-287,共8页
Frequent occurrence of large-scale cascading trip-off of wind turbine raises the concern about the decision process of ordered control of reactive power compensation devices. The theory of fuzzy multi-attribute decisi... Frequent occurrence of large-scale cascading trip-off of wind turbine raises the concern about the decision process of ordered control of reactive power compensation devices. The theory of fuzzy multi-attribute decision making is adopted to ascertain the action sequence of reactive power compensation devices. First, a set of evaluation indexes including control sensitivity, regulation margin, response time, response level and cost is set up, and fuzziness of the proposed qualitative indexes is introduced to make them comparable to the proposed quantitative indexes. Then a method to calculate fuzzy weight of each index is put forward for evaluating relative importance of the proposed indexes. Finally, the action sequence of reactive power compensation devices is determined through the theory of fuzzy compromise decision making. The case study shows that the proposed method is effective to obtain the action sequence of reactive power compensation device which correspond to experience. 展开更多
关键词 WIND power SYSTEM reactive power Compensation Device ORDERED control Fuzzy MULTI-ATTRIBUTE DECISION Making Evaluation Index
下载PDF
Optimal Reactive Power Compensation of Distribution Network to Prevent Reactive Power Reverse
15
作者 XING Jie CAO Ruilin +1 位作者 QUAN Zhaolong YUAN Zhiqiang 《Journal of Donghua University(English Edition)》 CAS 2021年第3期199-205,共7页
The capacitive reactive power reversal in the urban distribution grid is increasingly prominent at the period of light load in the last years.In severe cases,it will endanger the security and stability of power grid.T... The capacitive reactive power reversal in the urban distribution grid is increasingly prominent at the period of light load in the last years.In severe cases,it will endanger the security and stability of power grid.This paper presents an optimal reactive power compensation method of distribution network to prevent reactive power reverse.Firstly,an integrated reactive power planning(RPP)model with power factor constraints is established.Capacitors and reactors are considered to be installed in the distribution system at the same time.The objective function is the cost minimization of compensation and real power loss with transformers and lines during the planning period.Nodal power factor limits and reactor capacity constraints are new constraints.Then,power factor sensitivity with respect to reactive power is derived.An improved genetic algorithm by power factor sensitivity is used to solve the model.The optimal locations and sizes of reactors and capacitors can avoid reactive power reversal and power factor exceeding the limit.Finally,the effectiveness of the model and algorithm is proven by a typical high-voltage distribution network. 展开更多
关键词 reactive compensation planning high voltage distribution network power actor improved genetic algorithm
下载PDF
Enhancement of Available Transfer Capability with Facts Device in the Competitive Power Market
16
作者 Bairavan V. Manikandan Sathiasamuel C. Raja Paramasivam Venkatesh 《Engineering(科研)》 2010年第5期337-343,共7页
In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict ... In order to facilitate the electricity market operation and trade in the restructured environment, ample transmission capability should be provided to satisfy the demand of increasing power transactions. The conflict of this requirement and the restrictions on the transmission expansion in the restructured electrical market has motivated the development of methodologies to enhance the Available Transfer Capability (ATC) of the existing transmission grids. The insertion of FACTS devices in electrical systems seems to be a promising strategy to enhance ATC. In this paper, the viability and technical merits of boosting ATC using Thyristor Controlled Series Compensator (TCSC) is being analyzed. The work has been carried out on IEEE 30 bus and IEEE 118 bus systems. Bilateral and multilateral transactions are considered. Particle Swarm Optimization (PSO) algorithm and Genetic Algorithm (GA) are employed to obtain the optimal settings of TCSC. 展开更多
关键词 Available TRANSFER Capability Flexible AC Transmission Systems Particle SWARM Optimization Genetic Algorithm power TRANSFER Distribution Factors THYRISTOR controlled Series COMPENSATOR
下载PDF
Research on the Technology of Low Voltage Intelligent Reactive Compensation
17
作者 Yicong Liu 《International Journal of Technology Management》 2014年第1期32-34,共3页
In order to improve the power factor of the circuit, the article takes STM32 as core circuit to development reactive power compensation controller for low voltage intelligent reactive compensation. Circuit can detect ... In order to improve the power factor of the circuit, the article takes STM32 as core circuit to development reactive power compensation controller for low voltage intelligent reactive compensation. Circuit can detect electricity distribution network parameters, and send messages to mobile phone via SMS text messages by TC35 module, remote control compensation capacitor configuration parameters. Circuit with a flexible, reliable, convenient and practical features. This paper analyzes the structure of the controller hardware and software, and describes the hardware schematic circuit diagram and software diagram of the controller. Controller with integrated control, maximize the use of compensating equipment to improve grid power quality. 展开更多
关键词 reactive power compensation Electrical automation STM32 Intelligent control
下载PDF
A Case Study Survey of the Impact of the Inductive Loads on Power Quality
18
作者 Srdjan Ilickovic Saga Mujovic Jadranka Radovic 《Journal of Energy and Power Engineering》 2012年第10期1698-1705,共8页
Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmo... Power quality is a complex term that is defined by the legislation, but also as an obligation of the supplier and customer. The customer must return the negative effects of its consumers (taking reactive power, harmonic generation, phase unbalance) down to the prescribed limits. This primarily refers to the presence of non-linear consumers, leading to distortion of the basic parameters of voltage and current, in steady or transient conditions, and therefore the deformation of waveform. One way to reduce the negative feedback effects, especially with inductive loads, is the reactive energy compensation. The paper presents one of the solution for reactive power compensation, applied on the pumping station of public company "Waterworks and Sewerage---Bar", Bar. 展开更多
关键词 power quality reactive power power factor reactive power compensation compensation battery.
下载PDF
Accurate Reactive Power Controller and Power Factor Correction Using Fuzzy Logic
19
作者 Muhammad M.A.S. Mahmoud 《Journal of Energy and Power Engineering》 2013年第6期1163-1171,共9页
This paper presents the use of fuzzy logic technique to control the reactive power of load and hence improve the source power factor. A shunt compensator is proposed, which consists of a voltage controlled reactor by ... This paper presents the use of fuzzy logic technique to control the reactive power of load and hence improve the source power factor. A shunt compensator is proposed, which consists of a voltage controlled reactor by full-wave thyristor bridge in parallel with a capacitor. The proposed voltage control technique composed of two independent fuzzy controllers, primary and secondary. The PFC (primary fuzzy controller) is designed based on linearization method to introduce to the network the nearest value of reactive power (VAR) required to correct the power factor. The SFC (secondary fuzzy controller) is designed to achieve accurate compensation for the required VAR to achieve the pre-set power factor value. Simulations for 15 different practical study cases are presented to evaluate the performance of the controller, and the results show how the designed controller is fast and accurate. Harmonics analyses are carried out up to the 13th harmonic to determine the requirement of harmonics filter. 展开更多
关键词 power systems reactive power power factor fuzzy logic control.
下载PDF
Advanced Reactive Power Control at Individual Residences to Smooth Energy Loss Fluctuation for a Clustered Grid-Interconnected PV System
20
作者 Yusuke Miyamoto Yasuhiro Hayashi 《Journal of Energy and Power Engineering》 2013年第8期1539-1552,共14页
Reactive power control can control voltage within the proper range from the power network side or from the distribution generation (PV (photovoltaic)) side. Reactive power control from the power network side is si... Reactive power control can control voltage within the proper range from the power network side or from the distribution generation (PV (photovoltaic)) side. Reactive power control from the power network side is simpler because little controlled object apparatus, such as STATCOM, is required. However, it is difficult to optimize the individual voltages of residential consumers because few data have been obtained by the power network side as compared with the power generation side. Energy loss at each residence with PV is different due to the difference in the grid-interconnection condition, such as distribution line impedance when the same operating voltage is set at all residences. Therefore, in this paper, the authors propose an advanced reactive power control method for residential PV systems in order to optimally control the voltage at individual residences so as to minimize energy loss fluctuation. The effectiveness of the proposed reactive power control is demonstrated by numerical simulation. 展开更多
关键词 Distribution line grid-interconnection output suppression photovoltaic power systems reactive power sending voltage voltage control voltage increase.
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部