A numerical program is built to simulate the performance of a spark ignited two-stroke free-piston engine coupled with a linear generator. The computational model combines a series of dynamic and thermodynamic equatio...A numerical program is built to simulate the performance of a spark ignited two-stroke free-piston engine coupled with a linear generator. The computational model combines a series of dynamic and thermodynamic equations that are solved simultaneously to predict the performances of the engines. The dynamic analysis performed consists of an evaluation of the frictional force and load force introduced by the generator. The thermodynamic analysis used a single zone model to describe the engine' s working cycle which includes intake, scavenging, compression, combustion and expansion, and to evaluate the effect of heat transfer based on the first law of thermodynamics and the ideal gas state equation. Because there is no crankshaft, a time based Wiebe equation was used to express the fraction of fuel burned in the combustion. The calculated results were validated by using the experimental data from another research group. The results indicate that the free-piston generator has some advantages over conventional engines.展开更多
The free-piston engine generator(FPEG)is regarded as the next generation of energy conversion system which may replace traditional engines in the future.The effect of key operational parameters like excess air ratio o...The free-piston engine generator(FPEG)is regarded as the next generation of energy conversion system which may replace traditional engines in the future.The effect of key operational parameters like excess air ratio of input mixture and ignition position on the engine performance of a dual-cylinder FPEG was investigated,and their sensitivity was analyzed in this paper.The operating compression ratio of the system is susceptible to changes in excess air ratio and ignition position.At the same time,it decreases from 15.8 to 6.6 when excess air ratio increases from 0.85 to 1.15,but it increases from 6.1 to 13.3 as ignition position increases from 15 mm to 20 mm.The operating frequency and indicated power are more sensitive to changes in excess air ratio than ignition position.But it is the opposite for the indicated thermal efficiency and friction loss.Excess air ratio and ignition position have a quite similar influence on heat transfer.Therefore,from the perspective of system operation and performance,it is preferable to keep excess air coefficient slightly below 1.0.In contrast,when selecting ignition position,it is of great importance to comprehensively consider the risk of structural damage caused by the increase in the compression ratio and in-cylinder gas pressure.展开更多
In order to clarify the mechanism and main influencing factors of the vibration energy coupling transmission with a dual-piston structure,a thermodynamic and dynamic coupling model of the free piston linear generator(...In order to clarify the mechanism and main influencing factors of the vibration energy coupling transmission with a dual-piston structure,a thermodynamic and dynamic coupling model of the free piston linear generator(FPLG)was established.The system energy conversion,vibration energy coupling transmission,and influencing factors were studied in detail.The coupling transmission paths and the secondary influence mechanism from in-cylinder combustion on vibration energy transmission were obtained.In addition,the influence of the movement characteristics of the dual-piston on the vibration energy transmission was studied,and the typical parameter variation law was obtained,which provides theoretical guidance for the subsequent vibration reduction design of the FPLG.展开更多
The compression stroke characteristics of free-piston engine generator were studied. The numerical model of the compression stroke was established based on thermodynamics and dynamics equation,and the leak loss,heat l...The compression stroke characteristics of free-piston engine generator were studied. The numerical model of the compression stroke was established based on thermodynamics and dynamics equation,and the leak loss,heat loss and friction loss were considered. Through solving numerical equations,the in-cylinder pressure of compression stroke under different compression ratios was calculated,energy transfer and conversion process was analyzed,and the calculated results were experimentally verified. The results showed that the actual effective output of electronic energy and the compression energy stored in the com-pressed gas accounted for about 70%. The compression energy gradually increased with the increasing com-pression ratio. When the compression ratio was more than 7. 5,the actual compression energy increased slowly and the energy error between simulation and test decreased.展开更多
Free piston linear generator(FPLG)is a promising range extender for the electrical vehicle with unparallel advantages,such as compact structure,higher system efficiency,and reduced maintenance cost.However,due to the ...Free piston linear generator(FPLG)is a promising range extender for the electrical vehicle with unparallel advantages,such as compact structure,higher system efficiency,and reduced maintenance cost.However,due to the lack of the mechanic crankshaft,the related piston motion control is a challenge for the FPLG which causes problems such as misfire and crash and limits its widespread commercialization.Aimed at resolving the problems as misfire,a single-piston FPLG prototype has been designed and manufactured at Shanghai Jiao Tong University(SJTU).In this paper,the development process and experimental validation of the related control strategies were detailed.From the experimental studies,significant misfires were observed at first,while the FPLG operated in natural-aspiration conditions.The root cause of this misfire was then identified as the poor scavenging process,and a compressed air source was leveraged to enhance the related scavenging pressure.Afterward,optimal control parameters,in terms of scavenging pressure,air-fuel equivalence ratio,and ignition position,were then calibrated in this charged-scavenging condition.Eventually,the FPLG prototype has achieved a continuous stable operation of over 1000 cycles with an ignition rate of 100%and a cycle-to-cycle variation of less than 0.8%,produced an indicated power of 2.8 kW with an indicated thermal efficiency of 26%and an electrical power of 2.5 kW with an overall efficiency of 23.2%.展开更多
We proposed the flat-type permanent magnet linear alternator (LA) for free piston linear alternators (FPLAs) instead of the tubular one. Using the finite element method (FEM), we compare these two kinds of LAs. The FE...We proposed the flat-type permanent magnet linear alternator (LA) for free piston linear alternators (FPLAs) instead of the tubular one. Using the finite element method (FEM), we compare these two kinds of LAs. The FEM result shows that the flat-type permanent magnet LA has higher efficiency and larger output specific power than the tubular one, therefore more suitable for FPLAs, and that the alternator design can be optimized with respect to the permanent magnet length as well as the air gap.展开更多
文摘A numerical program is built to simulate the performance of a spark ignited two-stroke free-piston engine coupled with a linear generator. The computational model combines a series of dynamic and thermodynamic equations that are solved simultaneously to predict the performances of the engines. The dynamic analysis performed consists of an evaluation of the frictional force and load force introduced by the generator. The thermodynamic analysis used a single zone model to describe the engine' s working cycle which includes intake, scavenging, compression, combustion and expansion, and to evaluate the effect of heat transfer based on the first law of thermodynamics and the ideal gas state equation. Because there is no crankshaft, a time based Wiebe equation was used to express the fraction of fuel burned in the combustion. The calculated results were validated by using the experimental data from another research group. The results indicate that the free-piston generator has some advantages over conventional engines.
基金Projects(51675043,52005038)supported by the National Natural Science Foundation of China。
文摘The free-piston engine generator(FPEG)is regarded as the next generation of energy conversion system which may replace traditional engines in the future.The effect of key operational parameters like excess air ratio of input mixture and ignition position on the engine performance of a dual-cylinder FPEG was investigated,and their sensitivity was analyzed in this paper.The operating compression ratio of the system is susceptible to changes in excess air ratio and ignition position.At the same time,it decreases from 15.8 to 6.6 when excess air ratio increases from 0.85 to 1.15,but it increases from 6.1 to 13.3 as ignition position increases from 15 mm to 20 mm.The operating frequency and indicated power are more sensitive to changes in excess air ratio than ignition position.But it is the opposite for the indicated thermal efficiency and friction loss.Excess air ratio and ignition position have a quite similar influence on heat transfer.Therefore,from the perspective of system operation and performance,it is preferable to keep excess air coefficient slightly below 1.0.In contrast,when selecting ignition position,it is of great importance to comprehensively consider the risk of structural damage caused by the increase in the compression ratio and in-cylinder gas pressure.
文摘In order to clarify the mechanism and main influencing factors of the vibration energy coupling transmission with a dual-piston structure,a thermodynamic and dynamic coupling model of the free piston linear generator(FPLG)was established.The system energy conversion,vibration energy coupling transmission,and influencing factors were studied in detail.The coupling transmission paths and the secondary influence mechanism from in-cylinder combustion on vibration energy transmission were obtained.In addition,the influence of the movement characteristics of the dual-piston on the vibration energy transmission was studied,and the typical parameter variation law was obtained,which provides theoretical guidance for the subsequent vibration reduction design of the FPLG.
基金Supported by the National Natural Science Foundation of China(51006010)the Program of Introducing Talents of Discipline to Universities(B12022)
文摘The compression stroke characteristics of free-piston engine generator were studied. The numerical model of the compression stroke was established based on thermodynamics and dynamics equation,and the leak loss,heat loss and friction loss were considered. Through solving numerical equations,the in-cylinder pressure of compression stroke under different compression ratios was calculated,energy transfer and conversion process was analyzed,and the calculated results were experimentally verified. The results showed that the actual effective output of electronic energy and the compression energy stored in the com-pressed gas accounted for about 70%. The compression energy gradually increased with the increasing com-pression ratio. When the compression ratio was more than 7. 5,the actual compression energy increased slowly and the energy error between simulation and test decreased.
基金supported by the project of Shanghai Science and Technology Commission(No.19511108500).
文摘Free piston linear generator(FPLG)is a promising range extender for the electrical vehicle with unparallel advantages,such as compact structure,higher system efficiency,and reduced maintenance cost.However,due to the lack of the mechanic crankshaft,the related piston motion control is a challenge for the FPLG which causes problems such as misfire and crash and limits its widespread commercialization.Aimed at resolving the problems as misfire,a single-piston FPLG prototype has been designed and manufactured at Shanghai Jiao Tong University(SJTU).In this paper,the development process and experimental validation of the related control strategies were detailed.From the experimental studies,significant misfires were observed at first,while the FPLG operated in natural-aspiration conditions.The root cause of this misfire was then identified as the poor scavenging process,and a compressed air source was leveraged to enhance the related scavenging pressure.Afterward,optimal control parameters,in terms of scavenging pressure,air-fuel equivalence ratio,and ignition position,were then calibrated in this charged-scavenging condition.Eventually,the FPLG prototype has achieved a continuous stable operation of over 1000 cycles with an ignition rate of 100%and a cycle-to-cycle variation of less than 0.8%,produced an indicated power of 2.8 kW with an indicated thermal efficiency of 26%and an electrical power of 2.5 kW with an overall efficiency of 23.2%.
基金Project (No. 50806046) supported by the National Natural Science Foundation of China
文摘We proposed the flat-type permanent magnet linear alternator (LA) for free piston linear alternators (FPLAs) instead of the tubular one. Using the finite element method (FEM), we compare these two kinds of LAs. The FEM result shows that the flat-type permanent magnet LA has higher efficiency and larger output specific power than the tubular one, therefore more suitable for FPLAs, and that the alternator design can be optimized with respect to the permanent magnet length as well as the air gap.