The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick...The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick wall were calculated.In order to study the impact of light-weight external thermal insulation materials,a contrasting experiment was carried out between an external insulated room and an uninsulated room in August,2010,in Chongqing,China.The result shows that outside surface heat storage coefficient of the insulated wall is much less than that of the traditional wall.However,during sunny time,the surface temperature of external walls of the insulated room is obviously higher than that of the uninsulated room.In different orientations,due to different amounts of solar radiation and being irradiated in different time,the contrasting temperature difference(CTD) appears different regularity.In a word,using light-weight external thermal insulation materials has a negative impact on building surrounding thermal environment and people's health.Finally,some suggestions on how to eliminate the impact,such as improving the surface condition of the building envelop,and plating vertical greening,are put forward.展开更多
The external surface heat transfer coefficient of building envelope is one of the important parameters necessary for building energy saving design,but the basic data in high-altitude area are scarce.Therefore,the auth...The external surface heat transfer coefficient of building envelope is one of the important parameters necessary for building energy saving design,but the basic data in high-altitude area are scarce.Therefore,the authors propose a modified measurement method based on the heat balance of a model building,and use the same model building to measure its external surface heat transfer coefficient under outdoor conditions in Chengdu city,China at an altitude of 520 m and Daocheng city at an altitude of 3750 m respectively.The results show that the total heat transfer coefficient(h_(t))of building surface in high-altitude area is reduced by 34.48%.The influence of outdoor wind speed on the convective heat transfer coefficient(h_(c))in high-altitude area is not as significant as that in low-altitude area.The fitting relation between convection heat transfer coefficient and outdoor wind speed is also obtained.Under the same heating power,the average temperature rise of indoor and outdoor air at highaltitude is 41.9%higher than that at low altitude,and the average temperature rise of inner wall is 25.8%higher than that at low altitude.It shows that high-altitude area can create a more comfortable indoor thermal environment than low-altitude area under the same energy consumption condition.It is not appropriate to use the heat transfer characteristics of the exterior surface of buildings in low-altitude area for building energy saving design and related heating equipment selection and system terminal matching design in high-altitude area.展开更多
Researching parameters correlation is important to analysis of reliability uncertainty for passive system. The only criterion for traditional method to determine the parameters correlation is the correlation coefficie...Researching parameters correlation is important to analysis of reliability uncertainty for passive system. The only criterion for traditional method to determine the parameters correlation is the correlation coefficient threshold. This method is subjective and needs improvement. Taking loss of normal feedwater accident of AP1000 passive residual heat removal system( PRHRS)as example,a comprehensive method was proposed to resolve the subjectivity problem of traditional method. Comprehensive method took account of scatter diagram of parameters and thermal transmission rule and significance testing of correlation coefficient comprehensively when judging parameters correlation. By comparing the effect of parameters judged by traditional and comprehensive methods respectively, we found the distance of traditional method was larger than that of comprehensive method,showing some parameters impacting thermal transmission rule removed by traditional method and comprehensive method could judge more precise and scientific parameters. So comprehensive method should be used to judge linear relation between parameters and thermal transmission rule.展开更多
基金Project(2011BAJ03B13) supported by the National Key Technologies R&D Program of China
文摘The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick wall were calculated.In order to study the impact of light-weight external thermal insulation materials,a contrasting experiment was carried out between an external insulated room and an uninsulated room in August,2010,in Chongqing,China.The result shows that outside surface heat storage coefficient of the insulated wall is much less than that of the traditional wall.However,during sunny time,the surface temperature of external walls of the insulated room is obviously higher than that of the uninsulated room.In different orientations,due to different amounts of solar radiation and being irradiated in different time,the contrasting temperature difference(CTD) appears different regularity.In a word,using light-weight external thermal insulation materials has a negative impact on building surrounding thermal environment and people's health.Finally,some suggestions on how to eliminate the impact,such as improving the surface condition of the building envelop,and plating vertical greening,are put forward.
基金supported by the National Natural Science Foundation of China(52078314)。
文摘The external surface heat transfer coefficient of building envelope is one of the important parameters necessary for building energy saving design,but the basic data in high-altitude area are scarce.Therefore,the authors propose a modified measurement method based on the heat balance of a model building,and use the same model building to measure its external surface heat transfer coefficient under outdoor conditions in Chengdu city,China at an altitude of 520 m and Daocheng city at an altitude of 3750 m respectively.The results show that the total heat transfer coefficient(h_(t))of building surface in high-altitude area is reduced by 34.48%.The influence of outdoor wind speed on the convective heat transfer coefficient(h_(c))in high-altitude area is not as significant as that in low-altitude area.The fitting relation between convection heat transfer coefficient and outdoor wind speed is also obtained.Under the same heating power,the average temperature rise of indoor and outdoor air at highaltitude is 41.9%higher than that at low altitude,and the average temperature rise of inner wall is 25.8%higher than that at low altitude.It shows that high-altitude area can create a more comfortable indoor thermal environment than low-altitude area under the same energy consumption condition.It is not appropriate to use the heat transfer characteristics of the exterior surface of buildings in low-altitude area for building energy saving design and related heating equipment selection and system terminal matching design in high-altitude area.
基金Nuclear Reactor System Design Technology Foundation of National Key Laboratory,China(No.HT-JXYY-02-2014002)
文摘Researching parameters correlation is important to analysis of reliability uncertainty for passive system. The only criterion for traditional method to determine the parameters correlation is the correlation coefficient threshold. This method is subjective and needs improvement. Taking loss of normal feedwater accident of AP1000 passive residual heat removal system( PRHRS)as example,a comprehensive method was proposed to resolve the subjectivity problem of traditional method. Comprehensive method took account of scatter diagram of parameters and thermal transmission rule and significance testing of correlation coefficient comprehensively when judging parameters correlation. By comparing the effect of parameters judged by traditional and comprehensive methods respectively, we found the distance of traditional method was larger than that of comprehensive method,showing some parameters impacting thermal transmission rule removed by traditional method and comprehensive method could judge more precise and scientific parameters. So comprehensive method should be used to judge linear relation between parameters and thermal transmission rule.