Introduction: This study investigates the Experimental and Theoretical Investigation of Steel and Glass Fiber Reinforced Polymer (GFRP) Reinforced Slab Incorporating Alccofine and M-sand. Objective: Specific objective...Introduction: This study investigates the Experimental and Theoretical Investigation of Steel and Glass Fiber Reinforced Polymer (GFRP) Reinforced Slab Incorporating Alccofine and M-sand. Objective: Specific objectives include evaluating the mechanical properties and structural behaviour of steel and GFRP-reinforced one-way slabs and comparing experimental and theoretical predictions. Methods: Four different mix proportions were arrived at, comprising both conventional concrete and Alccofine-based concrete. In each formulation, a combination of normal river sand and M-sand was utilized. Results: Concrete with Alccofine exhibits superior mechanical properties, while M-sand incorporation minimally affects strength but reduces reliance on natural sand. GFRP-reinforced slabs display distinct brittle behaviour with significant deflections post-cracking, contrasting steel-reinforced slabs’ gradual, ductile failure. Discrepancies between experimental data and design recommendations underscore the need for guideline refinement. Conclusion: Alccofine and M-sand enhance concrete properties, but reinforcement type significantly influences slab behaviour. GFRP-reinforced slabs, though exhibiting lower values than steel, offer advantages in harsh environments, warranting further optimization.展开更多
为研究预应力混凝土用钢棒(steel bar for prestressed concrete, PC钢棒)-钢筋混合配筋混凝土柱的抗震性能,设计制作了5根相同尺寸、相同纵筋配筋率、不同PC钢棒替代率的PC钢棒-钢筋混合配筋混凝土柱试件,通过拟静力试验研究了PC钢棒...为研究预应力混凝土用钢棒(steel bar for prestressed concrete, PC钢棒)-钢筋混合配筋混凝土柱的抗震性能,设计制作了5根相同尺寸、相同纵筋配筋率、不同PC钢棒替代率的PC钢棒-钢筋混合配筋混凝土柱试件,通过拟静力试验研究了PC钢棒替代率对试件抗震性能的影响规律。结果表明:随着PC钢棒替代率的提高,试件的裂缝分布高度降低,裂缝数量变少,滞回曲线的饱满程度逐渐降低,耗能能力降低,残余位移角减小,自复位能力增强;当PC钢棒的替代率不大于50%时,各试件的峰值荷载接近;当PC钢棒的替代率大于50%时,试件的峰值荷载随PC钢棒替代率的增大而提高;当加载位移角相同且不大于1.0%时,配置PC钢棒的混凝土柱的残余位移角较为接近,且明显小于未配置PC钢棒的钢筋混凝土柱的残余位移角;当加载位移角相同且大于1%时,柱的残余位移角随着PC钢棒替代率的增高而降低。展开更多
The development of recycled aggregate concrete(RAC)provides a new approach to limiting the waste of natural resources.In the present study,the mechanical properties and deformability of RACs were improved by adding ba...The development of recycled aggregate concrete(RAC)provides a new approach to limiting the waste of natural resources.In the present study,the mechanical properties and deformability of RACs were improved by adding basalt fibers(BFs)and using external restraints,such as a fiber-reinforced polymer(FRP)jacket or a PVC pipe.Samples were tested under axial compression.The results showed that RAC(50%replacement of aggregate)containing 0.2%BFs had the best mechanical properties.Using either BFs or PVC reinforcement had a slight effect on the loadbearing capacity and mode of failure.With different levels of BFs,the compressive strengths of the specimens reinforced with 1-layer and 3-layer basalt fiber reinforced polymer(BFRP)increased by 6.7%–10.5%and 16.5%–23.7%,respectively,and the ultimate strains increased by 48.5%–80.7%and 97.1%–141.1%,respectively.The peak stress of the 3-layer BFRP-PVC increased by 42.2%,and the ultimate strain improved by 131.3%,relative to the control.This reinforcement combined the high tensile strength of BFRP,which improved the post-peak behavior,and PVC,which enhanced the structural durability.In addition,to investigate the influence of the various constraints on compressive behavior,the stress-strain response was analyzed.Based on the analysis of experimental results,a peak stress-strain model and an amended ultimate stress-strain model were proposed.The models were verified as well;the result showed that the predictions from calculations are generally consistent with the experimental data(error within 10%).The results of this study provide a theoretical basis and reference for future applications of fiber-reinforced recycled concrete.展开更多
An evaluation of existing strength of concrete columns confined with fiber-reinforced polymer( FRP) was presented with extensive collection of experimental data. According to the evaluation results, artificial neural ...An evaluation of existing strength of concrete columns confined with fiber-reinforced polymer( FRP) was presented with extensive collection of experimental data. According to the evaluation results, artificial neural networks( ANNs) model to predict the ultimate strength of FRP confined column with different shapes was proposed. The models had seven inputs including the column length,the tensile strength of the FRP in the hoop direction,the total thickness of FRP,the diameter of the concrete specimen,the elastic modulus of FRP,the corner radius and the concrete compressive strength. The compressive strength of the confined concrete was the output data. The results reveal that the proposed models have good prediction and generalization capacity with acceptable errors.展开更多
We proposed a bilinearity constitutive curve model of fiber reinforced polymer(FRP) confined concrete which includes a parabola in the first stage and a straight line in the second stage. The FRP-confined concrete has...We proposed a bilinearity constitutive curve model of fiber reinforced polymer(FRP) confined concrete which includes a parabola in the first stage and a straight line in the second stage. The FRP-confined concrete has powerful confinement status and weak confinement status leading to different equations of parabola. We analyzed the impacts of factors such as confinement ratio and restrain stiffness on confined concrete compressive strength,ultimate strain and other control parameters through finite element analysis. The results show that the confinement ratio determines the confinement status,and the increase of the confinement ratio has a limited capacity to increase the compressive strength. The deformation of confined concrete is influenced by restrain stiffness. The stronger the restrain stiffness is,the less the lateral deformation is and the greater ultimate axial strain will be. The consideration of equivalent section coefficient kse is needed in the non-circular section confined concrete. We analyzed the results and proposed boundary values of strong and weak confinement styles,a peak/inflection point stress and strain model,and a compressive strength and ultimate strain model.展开更多
This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer ...This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with sidebonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in AC1-440 and fib European code were compared with the experimental results.展开更多
In this paper,the influence of some important parameters affecting the flexural behavior of reinforced concrete beams strengthened with one layer of carbon fiber reinforced polymer(CFRP)laminate has been studied.For t...In this paper,the influence of some important parameters affecting the flexural behavior of reinforced concrete beams strengthened with one layer of carbon fiber reinforced polymer(CFRP)laminate has been studied.For this purpose,six reinforced concrete beams were cast and tested in the laboratory.Based on the obtained data,when CFRP laminate is applied to the tension face,too close to the steel rebar,the flexural strength of the strengthened beam is reduced.In general,the performance of the beam strengthened with one wide CFRP strip is better than that strengthened with two equivalent narrow strips.Ultimate load capacity of each strengthened beam was calculated based on the method given by the ACI 440.2R and compared with the test one.It is concluded that,to avoid the steel rebar-CFRP laminate interaction effect,the CFRP laminate depth-to-the effective depth ratio(df/d)should not be smaller than about 1.17.展开更多
Liquid polymers(LP)have become an important structural material used in the construction industry in the last decade.This paper investigates the viability of using commercially available LPs as a coating materia...Liquid polymers(LP)have become an important structural material used in the construction industry in the last decade.This paper investigates the viability of using commercially available LPs as a coating material to improve the flexural strength of fiber-modified concrete beams.The scope included preparing rectangular prism concrete beams with a concrete mixture including fly ash and fiber and coating them with four different liquid polymers at a uniform thickness following the curing process while one set of samples was maintained under the same conditions as a control group without coating.In addition,cylindrical samples were prepared to determine the compressive strength of the concrete mixture.Following the curing process in an unconfined open-air laboratory environment for another 28 days,concrete samples were tested to determine the flexural strength and deflection characteristics under center point loading equipment.The results revealed that all four coating types enhanced both the flexural strength and the average maximum deflection of the beams compared to the control group.While the enhancement in the flexural strength changed approximately between 5%and 36%depending on the coating type,the improvements in average maximum deflections varied between 3.7%and 28.4%.展开更多
This paper presents the results of the characterization by thermogravimetric analysis of a new composite material called polymeric concrete. The polymeric concrete contains micro-particles obtained from High Density P...This paper presents the results of the characterization by thermogravimetric analysis of a new composite material called polymeric concrete. The polymeric concrete contains micro-particles obtained from High Density Poly-Ethylene (HDPE) mechanically recycled (post-consumer bottles);the official Mexican standard NMX-E-232-SCFI-1999 considers the HDPE as the recyclable plastic material. Thermo-grams based on weight lost were obtained from the raw material (HDPE) and the polymer concrete in order to obtain the glass transition temperature (Tg) and melting temperature (Tf). The analysis conditions were defined from 20°C to 180°C and the heat rate of 1°C/minute. The results show that the glass transition temperature of polymeric concrete is 46°C and the HDPE is 38°C. These results mean that the polymeric concrete is more resistant to decomposition. With respect to the melting temperature, the results show that the 2°C difference between polymeric concrete and HDPE is not significant. The polymeric concrete with HDPE recycled can be considered as composite material thermoplastic. The new material melts when it is heated to 146°C and has the ability to be softened, processed and reprocessed with temperature and pressure changes, which make it possible to obtain molded pieces in the desired shape.展开更多
Reinforced concrete (RC) beams externally bonded with basalt fiber reinforced polymer (BFRP) are experimentally investigated by using different numbers of bonding plies, transverse anchorages as well as the initia...Reinforced concrete (RC) beams externally bonded with basalt fiber reinforced polymer (BFRP) are experimentally investigated by using different numbers of bonding plies, transverse anchorages as well as the initial conditions of strengthened beams. The performances of the BFRP strengthening are compared with those of the carbon fiber reinforced polymer (CFRP) and the glass fiber reinforced polymer (GFRP) under the same experimental condition. Experimental results indicate that the strength and ductility of the strengthened beam with two plies of the BFRP are improved remarkably than those with one ply. The strengthening effects of the BFRP lie between those of the CFRP and the GFRP. The BFRP strengthening is little influenced by pre-cracks of concrete. Most failures are caused by interfaciai debonding induced by flexural cracks in the experiment. Clamping of Uwraps along the whole beam is less efficient than endpoint anchorage for increasing the ultimate load of the strengthened beam. Finally, the models suggested by the five guidelines for predicting the debonding strain of the CFRP are extended to the BFRP and the conservative estimates of the debonding strain of the BFRP are given as well.展开更多
文摘Introduction: This study investigates the Experimental and Theoretical Investigation of Steel and Glass Fiber Reinforced Polymer (GFRP) Reinforced Slab Incorporating Alccofine and M-sand. Objective: Specific objectives include evaluating the mechanical properties and structural behaviour of steel and GFRP-reinforced one-way slabs and comparing experimental and theoretical predictions. Methods: Four different mix proportions were arrived at, comprising both conventional concrete and Alccofine-based concrete. In each formulation, a combination of normal river sand and M-sand was utilized. Results: Concrete with Alccofine exhibits superior mechanical properties, while M-sand incorporation minimally affects strength but reduces reliance on natural sand. GFRP-reinforced slabs display distinct brittle behaviour with significant deflections post-cracking, contrasting steel-reinforced slabs’ gradual, ductile failure. Discrepancies between experimental data and design recommendations underscore the need for guideline refinement. Conclusion: Alccofine and M-sand enhance concrete properties, but reinforcement type significantly influences slab behaviour. GFRP-reinforced slabs, though exhibiting lower values than steel, offer advantages in harsh environments, warranting further optimization.
文摘为研究预应力混凝土用钢棒(steel bar for prestressed concrete, PC钢棒)-钢筋混合配筋混凝土柱的抗震性能,设计制作了5根相同尺寸、相同纵筋配筋率、不同PC钢棒替代率的PC钢棒-钢筋混合配筋混凝土柱试件,通过拟静力试验研究了PC钢棒替代率对试件抗震性能的影响规律。结果表明:随着PC钢棒替代率的提高,试件的裂缝分布高度降低,裂缝数量变少,滞回曲线的饱满程度逐渐降低,耗能能力降低,残余位移角减小,自复位能力增强;当PC钢棒的替代率不大于50%时,各试件的峰值荷载接近;当PC钢棒的替代率大于50%时,试件的峰值荷载随PC钢棒替代率的增大而提高;当加载位移角相同且不大于1.0%时,配置PC钢棒的混凝土柱的残余位移角较为接近,且明显小于未配置PC钢棒的钢筋混凝土柱的残余位移角;当加载位移角相同且大于1%时,柱的残余位移角随着PC钢棒替代率的增高而降低。
基金supported by the Natural Science Foundation Project of Liaoning Provincial Department of Education of China under Grant No.JJL201915404,Zhejiang Provincial Natural Science Foundation of China under Grant No.LQ22E080024 and Zhejiang Province Department of Education Fund of China under Grant No.Y202146776.
文摘The development of recycled aggregate concrete(RAC)provides a new approach to limiting the waste of natural resources.In the present study,the mechanical properties and deformability of RACs were improved by adding basalt fibers(BFs)and using external restraints,such as a fiber-reinforced polymer(FRP)jacket or a PVC pipe.Samples were tested under axial compression.The results showed that RAC(50%replacement of aggregate)containing 0.2%BFs had the best mechanical properties.Using either BFs or PVC reinforcement had a slight effect on the loadbearing capacity and mode of failure.With different levels of BFs,the compressive strengths of the specimens reinforced with 1-layer and 3-layer basalt fiber reinforced polymer(BFRP)increased by 6.7%–10.5%and 16.5%–23.7%,respectively,and the ultimate strains increased by 48.5%–80.7%and 97.1%–141.1%,respectively.The peak stress of the 3-layer BFRP-PVC increased by 42.2%,and the ultimate strain improved by 131.3%,relative to the control.This reinforcement combined the high tensile strength of BFRP,which improved the post-peak behavior,and PVC,which enhanced the structural durability.In addition,to investigate the influence of the various constraints on compressive behavior,the stress-strain response was analyzed.Based on the analysis of experimental results,a peak stress-strain model and an amended ultimate stress-strain model were proposed.The models were verified as well;the result showed that the predictions from calculations are generally consistent with the experimental data(error within 10%).The results of this study provide a theoretical basis and reference for future applications of fiber-reinforced recycled concrete.
基金National Natural Science Foundation of China(No.51278391)
文摘An evaluation of existing strength of concrete columns confined with fiber-reinforced polymer( FRP) was presented with extensive collection of experimental data. According to the evaluation results, artificial neural networks( ANNs) model to predict the ultimate strength of FRP confined column with different shapes was proposed. The models had seven inputs including the column length,the tensile strength of the FRP in the hoop direction,the total thickness of FRP,the diameter of the concrete specimen,the elastic modulus of FRP,the corner radius and the concrete compressive strength. The compressive strength of the confined concrete was the output data. The results reveal that the proposed models have good prediction and generalization capacity with acceptable errors.
基金Funded by the Science and Technology Plan Project (No. 62065) of Guangzhou.
文摘We proposed a bilinearity constitutive curve model of fiber reinforced polymer(FRP) confined concrete which includes a parabola in the first stage and a straight line in the second stage. The FRP-confined concrete has powerful confinement status and weak confinement status leading to different equations of parabola. We analyzed the impacts of factors such as confinement ratio and restrain stiffness on confined concrete compressive strength,ultimate strain and other control parameters through finite element analysis. The results show that the confinement ratio determines the confinement status,and the increase of the confinement ratio has a limited capacity to increase the compressive strength. The deformation of confined concrete is influenced by restrain stiffness. The stronger the restrain stiffness is,the less the lateral deformation is and the greater ultimate axial strain will be. The consideration of equivalent section coefficient kse is needed in the non-circular section confined concrete. We analyzed the results and proposed boundary values of strong and weak confinement styles,a peak/inflection point stress and strain model,and a compressive strength and ultimate strain model.
文摘This paper presents the results of an experimental investigation on the response of pre-damaged reinforced concrete (RC) beam strengthened in shear using applied-epoxy unidirectional carbon fiber reinforced polymer (CFRP) sheet. The reasearch included four test rectangular simply supported RC beams in shear capacity. One is the control beam, two RC beams are damaged to a predetermined degree from ultimate shear capacity of the control beam, and the last beam is left without pre-damaged and then strengthened with using externally bonded carbon fiber reinforced polymer to upgrade their shear capacity. We focused on the damage degree to beams during strengthening, therefore, only the beams with sidebonded CFRPs strips and horizontal anchored strips were used. The results show the feasibility of using CFRPs to restore or increase the load-carrying capacity in the shear of damaged RC beams. The failure mode of all the CFRP-strengthened beams is debonding of CFRP vertical strips. Two prediction available models in AC1-440 and fib European code were compared with the experimental results.
文摘In this paper,the influence of some important parameters affecting the flexural behavior of reinforced concrete beams strengthened with one layer of carbon fiber reinforced polymer(CFRP)laminate has been studied.For this purpose,six reinforced concrete beams were cast and tested in the laboratory.Based on the obtained data,when CFRP laminate is applied to the tension face,too close to the steel rebar,the flexural strength of the strengthened beam is reduced.In general,the performance of the beam strengthened with one wide CFRP strip is better than that strengthened with two equivalent narrow strips.Ultimate load capacity of each strengthened beam was calculated based on the method given by the ACI 440.2R and compared with the test one.It is concluded that,to avoid the steel rebar-CFRP laminate interaction effect,the CFRP laminate depth-to-the effective depth ratio(df/d)should not be smaller than about 1.17.
文摘Liquid polymers(LP)have become an important structural material used in the construction industry in the last decade.This paper investigates the viability of using commercially available LPs as a coating material to improve the flexural strength of fiber-modified concrete beams.The scope included preparing rectangular prism concrete beams with a concrete mixture including fly ash and fiber and coating them with four different liquid polymers at a uniform thickness following the curing process while one set of samples was maintained under the same conditions as a control group without coating.In addition,cylindrical samples were prepared to determine the compressive strength of the concrete mixture.Following the curing process in an unconfined open-air laboratory environment for another 28 days,concrete samples were tested to determine the flexural strength and deflection characteristics under center point loading equipment.The results revealed that all four coating types enhanced both the flexural strength and the average maximum deflection of the beams compared to the control group.While the enhancement in the flexural strength changed approximately between 5%and 36%depending on the coating type,the improvements in average maximum deflections varied between 3.7%and 28.4%.
文摘This paper presents the results of the characterization by thermogravimetric analysis of a new composite material called polymeric concrete. The polymeric concrete contains micro-particles obtained from High Density Poly-Ethylene (HDPE) mechanically recycled (post-consumer bottles);the official Mexican standard NMX-E-232-SCFI-1999 considers the HDPE as the recyclable plastic material. Thermo-grams based on weight lost were obtained from the raw material (HDPE) and the polymer concrete in order to obtain the glass transition temperature (Tg) and melting temperature (Tf). The analysis conditions were defined from 20°C to 180°C and the heat rate of 1°C/minute. The results show that the glass transition temperature of polymeric concrete is 46°C and the HDPE is 38°C. These results mean that the polymeric concrete is more resistant to decomposition. With respect to the melting temperature, the results show that the 2°C difference between polymeric concrete and HDPE is not significant. The polymeric concrete with HDPE recycled can be considered as composite material thermoplastic. The new material melts when it is heated to 146°C and has the ability to be softened, processed and reprocessed with temperature and pressure changes, which make it possible to obtain molded pieces in the desired shape.
文摘Reinforced concrete (RC) beams externally bonded with basalt fiber reinforced polymer (BFRP) are experimentally investigated by using different numbers of bonding plies, transverse anchorages as well as the initial conditions of strengthened beams. The performances of the BFRP strengthening are compared with those of the carbon fiber reinforced polymer (CFRP) and the glass fiber reinforced polymer (GFRP) under the same experimental condition. Experimental results indicate that the strength and ductility of the strengthened beam with two plies of the BFRP are improved remarkably than those with one ply. The strengthening effects of the BFRP lie between those of the CFRP and the GFRP. The BFRP strengthening is little influenced by pre-cracks of concrete. Most failures are caused by interfaciai debonding induced by flexural cracks in the experiment. Clamping of Uwraps along the whole beam is less efficient than endpoint anchorage for increasing the ultimate load of the strengthened beam. Finally, the models suggested by the five guidelines for predicting the debonding strain of the CFRP are extended to the BFRP and the conservative estimates of the debonding strain of the BFRP are given as well.