A partition solution implemented by a cold air curtain for two asymmetric discrete heat sources in a twodimensional rectangular enclosure was numerically studied. Main attentions were focused on the effects of Reynold...A partition solution implemented by a cold air curtain for two asymmetric discrete heat sources in a twodimensional rectangular enclosure was numerically studied. Main attentions were focused on the effects of Reynolds number, Grashof number, separation distance between heat sources, and buoyancy ratio. It is found that the airflow and heat transfer are not only determined by governing parameters, but also affected by boundary conditions. It is also found that nearly symmetry of flow structure corresponds to nearly thermal partition, and the symmetry can be enhanced when Reynolds number, separation distance and buoyancy ratio increase. In addition, it is observed that there is a minimum Reynolds number for obtaining nearly thermal partition, which increases when Grashof number increases.展开更多
With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the ...With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.展开更多
Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categor...Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.展开更多
Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. ...Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. Taking Sanhejian coal mine as an example, this paper introduced the technology scheme of heat disaster governance using surface water cold source. The paper presents the basics of this field experiment at the beginning, following by the design and site layout of the cooling system including the analysis and calculation of cold source. Numerical calculation method is also applied based on the operation parameters to simulate the influence to the surface river ecosystem. The results suggest that the temperature of surface water shall be lower than 34 ℃ after heat exchange, and when more cooling capacities are needed in the future, increasing the water flow is more favorable than increasing the cooling range of water, which is better for the ecological environment protection,展开更多
Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-fe...Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-ference between the heating and cooling loads,the system will suffer from a soil thermal imbalance which may further decline the system performance and even cause a system failure.A hybrid ground source heat pump sys-tem that integrates auxiliary equipment can solve the problem,however,it needs additional investment and a complicated control strategy.In this paper,the zoning operation of energy piles can effectively improve the tem-perature recovery ability of soil in the energy pile group and thus alleviate the soil thermal imbalance.Specifically,a heating-dominated residential building in Beijing is selected for a case study,with 144 energy piles arranged in a 12×12 layout.An analytical model of the spiral-coil energy pile group with seepage will be adopted,which can consider the groundwater flow,the geometry of spiral coils,and the thermal interaction among different energy piles,achieving high calculation accuracy and fast calculation speed.Based on this analytical energy pile model,a system model will be built to investigate the system performance influenced by different zoning operation strategies.Results show that intensive heat injection into the center of the pile group(Strategy 2 and Strategy 3)or heat extraction from the outer layer of the pile group(Strategy 4)can relieve the cold accumulation.Strategy 2 can relieve the outlet temperature decline from 5.54℃ to 4.46℃ and improve the heating COP from 3.297 to 3.423 compared to the conventional full operation strategy.Although the annual heat pump COP of Strategy 2 is a little lower than that of conventional full operation strategy,Strategy 2 has the shortest unmet heating or cooling time.Therefore,the proposed zoning operation strategy can achieve good system efficiency and excellent system reliability compared to the conventional strategy.展开更多
基金Project (50408019) supported by the National Natural Science Foundation of China
文摘A partition solution implemented by a cold air curtain for two asymmetric discrete heat sources in a twodimensional rectangular enclosure was numerically studied. Main attentions were focused on the effects of Reynolds number, Grashof number, separation distance between heat sources, and buoyancy ratio. It is found that the airflow and heat transfer are not only determined by governing parameters, but also affected by boundary conditions. It is also found that nearly symmetry of flow structure corresponds to nearly thermal partition, and the symmetry can be enhanced when Reynolds number, separation distance and buoyancy ratio increase. In addition, it is observed that there is a minimum Reynolds number for obtaining nearly thermal partition, which increases when Grashof number increases.
基金Financial supports for this project, provided by the key program supported by the National Natural Science Foundation of China(No. 51134005)the Doctoral Scientific Fund Project of the Ministry of Education of China (No. 20120023120004), are gratefully acknowledged
文摘With the increase of mining depth, more and deeper coal mines are limited by heat disaster. The cooling energy in deep mine cooling system comes from mine water inrush or ground cooling tower, but we cannot adopt the two methods because mine water inrush in many old coal mines in China is limited. What is more, the cooling pipelines cannot be put in narrow pit-shaft. To settle the problem above, according to the characteristics of Zhangxiaolou Coal Mine, this paper adopts the deep mine return air as the cooling energy for deep mine cooling system. In addition, we carried out cite test to extract cold energy from return air. Through monitoring the water quantity, water temperature of cooling system and air temperature, we got the thermodynamic equilibrium parameters during the cooling energy acquisition analysis and the effect of cooling system that the temperature and humidity on working face are respectively reduced to 8-12 ℃ and 8-15% through cooling. This research offers experimental reference for deep mine cooling which lacks cooling energy.
文摘Selection of air conditioning(AC) cold/heat sources generally concerns about certain aspects and cannot reveal the whole profile of the problems. Grey relation analysis (GRA) is a data processing method to categorize the correlation extent of compared sequences and a certain reference sequence in a system with uncertain information. It is applied to evaluating and selecting AC cold/heat sources from four main aspects, which are technology, economy, reliability, and operation and management. Case study shows that the result for selecting AC cold/heat sources with the GRA method can be more reasonable and convincible. Thus it offers a new approach for designers in heating, ventilating and air conditioning field to compare and evaluate different AC cold/heat sou rces.
基金supported by the Key Project of National Natural Science Foundation‘‘Deep Heat Governance and Utilization’’(No.51134005)the Doctoral Fund of Ministry of Education(No.20120023120004)
文摘Regarding the lack of cold source for underground cooling systems from either mine inflow or return air, field experiments were taken in a high temperature deep coal mine with abundant cold source from surface water. Taking Sanhejian coal mine as an example, this paper introduced the technology scheme of heat disaster governance using surface water cold source. The paper presents the basics of this field experiment at the beginning, following by the design and site layout of the cooling system including the analysis and calculation of cold source. Numerical calculation method is also applied based on the operation parameters to simulate the influence to the surface river ecosystem. The results suggest that the temperature of surface water shall be lower than 34 ℃ after heat exchange, and when more cooling capacities are needed in the future, increasing the water flow is more favorable than increasing the cooling range of water, which is better for the ecological environment protection,
基金The authors gratefully acknowledge the funding support from Sun Yat-Sen University(76140-18841230 and 2021qntd15)Guangdong Basic and Applied Basic Research Foundation(2021A1515011739,2020A1515110391 and 2020B1515120083).
文摘Energy piles have attracted increasing interest for application in ground source heat pumps,because it is environment-friendly,energy-efficient,and without additional drilling cost.However,when there is a large dif-ference between the heating and cooling loads,the system will suffer from a soil thermal imbalance which may further decline the system performance and even cause a system failure.A hybrid ground source heat pump sys-tem that integrates auxiliary equipment can solve the problem,however,it needs additional investment and a complicated control strategy.In this paper,the zoning operation of energy piles can effectively improve the tem-perature recovery ability of soil in the energy pile group and thus alleviate the soil thermal imbalance.Specifically,a heating-dominated residential building in Beijing is selected for a case study,with 144 energy piles arranged in a 12×12 layout.An analytical model of the spiral-coil energy pile group with seepage will be adopted,which can consider the groundwater flow,the geometry of spiral coils,and the thermal interaction among different energy piles,achieving high calculation accuracy and fast calculation speed.Based on this analytical energy pile model,a system model will be built to investigate the system performance influenced by different zoning operation strategies.Results show that intensive heat injection into the center of the pile group(Strategy 2 and Strategy 3)or heat extraction from the outer layer of the pile group(Strategy 4)can relieve the cold accumulation.Strategy 2 can relieve the outlet temperature decline from 5.54℃ to 4.46℃ and improve the heating COP from 3.297 to 3.423 compared to the conventional full operation strategy.Although the annual heat pump COP of Strategy 2 is a little lower than that of conventional full operation strategy,Strategy 2 has the shortest unmet heating or cooling time.Therefore,the proposed zoning operation strategy can achieve good system efficiency and excellent system reliability compared to the conventional strategy.