The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in othe...The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities.展开更多
提出了一种空气罐与超压泄压阀联合设置的停泵水锤防护方案,并基于瞬变流计算的特征线法建立了空气罐、液控蝶阀、超压泄压阀等边界条件的数学模型,模拟了停泵工况下系统的压力变化过程.结合工程实例,对比分析了空气罐单独防护、空气罐...提出了一种空气罐与超压泄压阀联合设置的停泵水锤防护方案,并基于瞬变流计算的特征线法建立了空气罐、液控蝶阀、超压泄压阀等边界条件的数学模型,模拟了停泵工况下系统的压力变化过程.结合工程实例,对比分析了空气罐单独防护、空气罐与两阶段关闭泵后液控蝶阀联合防护以及空气罐与超压泄压阀联合防护对停泵水锤的影响.在空气罐体型一定时,对超压泄压阀的启闭规律进行了敏感性分析.计算结果表明,空气罐与两阶段关闭泵后液控蝶阀联合防护方案对输水系统正负水锤防护均不利;而空气罐与超压泄压阀联合防护方案对输水系统正负水锤均有较好的防护效果,与空气罐单独防护方案相比,泵后高压管段最高压应力由1.343 MPa降至1.087 MPa,在满足承压标准1.2 MPa的基础上安全裕度提高了9.4%,空气罐体型也由200 m 3缩减至160 m 3.超压泄压阀应在5 s内开启至全开度,且开启后持续时间应接近1个相长.展开更多
基金support from the Government of the Russian Federation (Mega grant No.075-15-2021-612 of June 4,2021) for funding scientific research in Russia.
文摘The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities.
文摘提出了一种空气罐与超压泄压阀联合设置的停泵水锤防护方案,并基于瞬变流计算的特征线法建立了空气罐、液控蝶阀、超压泄压阀等边界条件的数学模型,模拟了停泵工况下系统的压力变化过程.结合工程实例,对比分析了空气罐单独防护、空气罐与两阶段关闭泵后液控蝶阀联合防护以及空气罐与超压泄压阀联合防护对停泵水锤的影响.在空气罐体型一定时,对超压泄压阀的启闭规律进行了敏感性分析.计算结果表明,空气罐与两阶段关闭泵后液控蝶阀联合防护方案对输水系统正负水锤防护均不利;而空气罐与超压泄压阀联合防护方案对输水系统正负水锤均有较好的防护效果,与空气罐单独防护方案相比,泵后高压管段最高压应力由1.343 MPa降至1.087 MPa,在满足承压标准1.2 MPa的基础上安全裕度提高了9.4%,空气罐体型也由200 m 3缩减至160 m 3.超压泄压阀应在5 s内开启至全开度,且开启后持续时间应接近1个相长.