The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowle...The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building.展开更多
Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electri...Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption.展开更多
The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analy...The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.展开更多
Evaporative cooling(EC)is an ancient technique that is usually suitable for hot and dry climatic conditions due to the potential of water vapor evaporation.In this study,three kinds of evaporative cooling systems such...Evaporative cooling(EC)is an ancient technique that is usually suitable for hot and dry climatic conditions due to the potential of water vapor evaporation.In this study,three kinds of evaporative cooling systems such as direct EC(DEC),indirect EC(IEC),and Maisotsenko cycle EC(MEC)were locally developed at lab-scale.The performance of the systems was evaluated and compared for agricultural storage and livestock air-conditioning application in Pakistan.The experiments were performed for climatic conditions of Multan city(Pakistan)and the data were collected for hourly and daily basis.According to the results,it was observed that the DEC system has the ability to reduce the temperature of ambient air to an average of 8.5℃.Whilst IEC and MEC systems were able to drop the temperature of ambient air to an average of 6.8℃and 8.9℃,respectively.As per the results,the DEC system remained behind to provide desired conditions for livestock and agricultural product storage applications due to excessive humidity.On the other hand,the IEC and MEC systems can achieve the desired conditions for livestock application,but could not provide feasible conditions for various fruits and vegetable storage.The study concludes that hybrid EC systems can be developed to provide desired conditions for a wide range of applications under varying climatic conditions.展开更多
针对传统的铅冷快堆非能动余热排出系统设计中存在开发效率低、迭代周期长、模型二义性等前期需求问题,本研究将基于模型的系统工程(Model-based System Engineering,MBSE)方法应用于铅冷快堆非能动余热排出系统设计需求中,结合设计流...针对传统的铅冷快堆非能动余热排出系统设计中存在开发效率低、迭代周期长、模型二义性等前期需求问题,本研究将基于模型的系统工程(Model-based System Engineering,MBSE)方法应用于铅冷快堆非能动余热排出系统设计需求中,结合设计流程进行系统架构的初步设计,该系统架构由需求分析、功能分析和设计综合三部分组成。结果表明:需求分析阶段生成的需求图和用例图可捕获系统需求并确定系统顶层用例;功能分析阶段绘制的时序图、活动图和状态机图可形成系统功能模型并提供早期确认与验证;设计综合阶段建立的白盒模型最终实现系统架构的分析与设计。采用该方法设计的系统架构可确保前后设计需求一致性,进一步降低设计风险并提高设计效率,可为数字化铅冷快堆非能动余热排出系统设计与优化提供应用参考。展开更多
文摘The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building.
基金This work was supported by the National Key Research and Development Program of China(No.2017YFB0903201)the Science and Technology Project of China Southern Power Grid(No.GDKJXM20172171).
文摘Solar energy powered organic Rankine cycle vapor compression cycle(ORC-VCC)is a good alternative to convert solar heat into a cooling effect.In this study,an ORC-VCC system driven by solar energy combined with electric motor is proposed to ensure smooth operation under the conditions that solar radiation is unstable and discontinuous,and an office building located in Guangzhou,China is selected as a case study.The results show that beam solar radiation and generation temperature have considerable effects on the system performance.There is an optimal generation temperature at which the system achieves optimum performance.Also,as a key indicator,the cooling power per square meter collector should be considered in the hybrid solar cooling system in design process.Compared to the vapor compression cooling system,the hybrid cooling system can save almost 68.23%of electricity consumption.
基金Xi'an Polytechnic University Graduate Innovational Foundation(chx080608)
文摘The evaporative cooling,which assists the refrigeration machinery air-conditioning systems test-rig,has been designed.Its structure and working principle were described,and the performance test was conducted and analyzed.The test shows that making full use of the evaporative cooling "free cooling" in Spring and Autumn seasons can fully meet the requirements of air-conditioned comfort through the switch of the function in different seasons.Taking into account the evaporative cooling fan and pump energy consumption,compared with the traditional mechanical refrigeration system,more than 80 percent of energy can be saved,and the energy efficiency ratio of the Unit(EER)is as high as 7.63.Using the two stages of indirect evaporative cooling to pre-cool the new wind in summer,under the conditions of the same air supply temperature requirements,0.83 kg/s chilled water saved can be equivalent to the traditional mechanical refrigeration system,and when the new wind ratio up to 50 percent,more than 10 percent load was reduced in mechanical refrigeration system.The overall EER increased about 35 percent.
基金funded by Bahauddin Zakariya University,Multan,Pakistan under the Director Research/ORIC grant entitled“Development and performance evaluation of prototypes of direct and indirect evaporative cooling-based air-conditioning systems”。
文摘Evaporative cooling(EC)is an ancient technique that is usually suitable for hot and dry climatic conditions due to the potential of water vapor evaporation.In this study,three kinds of evaporative cooling systems such as direct EC(DEC),indirect EC(IEC),and Maisotsenko cycle EC(MEC)were locally developed at lab-scale.The performance of the systems was evaluated and compared for agricultural storage and livestock air-conditioning application in Pakistan.The experiments were performed for climatic conditions of Multan city(Pakistan)and the data were collected for hourly and daily basis.According to the results,it was observed that the DEC system has the ability to reduce the temperature of ambient air to an average of 8.5℃.Whilst IEC and MEC systems were able to drop the temperature of ambient air to an average of 6.8℃and 8.9℃,respectively.As per the results,the DEC system remained behind to provide desired conditions for livestock and agricultural product storage applications due to excessive humidity.On the other hand,the IEC and MEC systems can achieve the desired conditions for livestock application,but could not provide feasible conditions for various fruits and vegetable storage.The study concludes that hybrid EC systems can be developed to provide desired conditions for a wide range of applications under varying climatic conditions.
文摘针对传统的铅冷快堆非能动余热排出系统设计中存在开发效率低、迭代周期长、模型二义性等前期需求问题,本研究将基于模型的系统工程(Model-based System Engineering,MBSE)方法应用于铅冷快堆非能动余热排出系统设计需求中,结合设计流程进行系统架构的初步设计,该系统架构由需求分析、功能分析和设计综合三部分组成。结果表明:需求分析阶段生成的需求图和用例图可捕获系统需求并确定系统顶层用例;功能分析阶段绘制的时序图、活动图和状态机图可形成系统功能模型并提供早期确认与验证;设计综合阶段建立的白盒模型最终实现系统架构的分析与设计。采用该方法设计的系统架构可确保前后设计需求一致性,进一步降低设计风险并提高设计效率,可为数字化铅冷快堆非能动余热排出系统设计与优化提供应用参考。