Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure...Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load.展开更多
In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, doe...In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper.展开更多
This research investigated a pavement system on steel bridge decks that use epoxy resin(EP)bonded ultra-high performance concrete(UHPC).Through FEM analysis and static and dynamic bending fatigue tests of the composit...This research investigated a pavement system on steel bridge decks that use epoxy resin(EP)bonded ultra-high performance concrete(UHPC).Through FEM analysis and static and dynamic bending fatigue tests of the composite structure,the influences of the interface of the pavement layer,reinforcement,and different paving materials on the structural performance were compared and analyzed.The results show that the resin bonded UHPC pavement structure can reduce the weld strain in the steel plate by about 32%and the relative deflection between ribs by about 52%under standard axial load conditions compared to traditional pavements.The EP bonding layer can nearly double the drawing strength of the pavement interface from 1.3 MPa,and improve the bending resistance of the UHPC structure on steel bridge decks by about 50%;the bending resistance of reinforced UHPC structures is twice that of unreinforced UHPC structure,and the dynamic deflection of the UHPC pavement structure increases exponentially with increasing fatigue load.The fatigue life is about 1.2×10^(7) cycles under a fixed force of 9 kN and a dynamic deflection of 0.35 mm,which meets the requirements for fatigue performance of pavements on steel bridge decks under traffic conditions of large flow and heavy load.展开更多
文摘Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load.
文摘In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper.
基金This work is jointly supported by the Natural Science Foundation of Jiangsu Province(Nos.BK20180113 and BK20181112)the Jiangsu Provincial Programme for High-Level Talents in Six Areas(No.XCL-CXTD-007)+1 种基金the Youth Programme of National Natural Science Foundation of China(Grant No.51908285)the Transformation Project of Scientific and Technological Achievements of Qinghai Province(No.2017-SF-134).
文摘This research investigated a pavement system on steel bridge decks that use epoxy resin(EP)bonded ultra-high performance concrete(UHPC).Through FEM analysis and static and dynamic bending fatigue tests of the composite structure,the influences of the interface of the pavement layer,reinforcement,and different paving materials on the structural performance were compared and analyzed.The results show that the resin bonded UHPC pavement structure can reduce the weld strain in the steel plate by about 32%and the relative deflection between ribs by about 52%under standard axial load conditions compared to traditional pavements.The EP bonding layer can nearly double the drawing strength of the pavement interface from 1.3 MPa,and improve the bending resistance of the UHPC structure on steel bridge decks by about 50%;the bending resistance of reinforced UHPC structures is twice that of unreinforced UHPC structure,and the dynamic deflection of the UHPC pavement structure increases exponentially with increasing fatigue load.The fatigue life is about 1.2×10^(7) cycles under a fixed force of 9 kN and a dynamic deflection of 0.35 mm,which meets the requirements for fatigue performance of pavements on steel bridge decks under traffic conditions of large flow and heavy load.