期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
An integrated computational method for calculating dynamic thermal bridges of building facades in tropical countries
1
作者 Miktha Farid Alkadri Muhammad Rafif Cahyadi Agung Francesco De Luca 《Frontiers of Architectural Research》 CSCD 2024年第1期201-218,共18页
Identifying thermal bridges on building façades has been a great challenge for architects,especially during the conceptual design stage.This is not only due to the complexity of parameters when calculating therma... Identifying thermal bridges on building façades has been a great challenge for architects,especially during the conceptual design stage.This is not only due to the complexity of parameters when calculating thermal bridges,but also lack of feature integration between building energy simulation(BES)tools and the actual building conditions.For example,existing BES tools predominantly calculate thermal bridges only in steady state without considering the temperature dynamic behaviour of building outdoors.Consequently,relevant features such as thermal delay,decrement factor,and operative temperature are often neglected,and this can lead to miscalculation of energy consumption.This study then proposes an integrated method to calculate dynamic thermal bridges under transient conditions by incorporating field observations and computational simulations of thermal bridges.More specifically,the proposed method employs several measurement tools such as HOBO data logger to record the actual conditions of indoor and outdoor room temperature and thermal cameras to identify the surface temperature of selected building junctions.The actual datasets are then integrated with the simulation workflow developed in BES tools.This study ultimately enables architects not only to identify potential thermal bridges on existing building façades but also to support material and geometric exploration in early design phase. 展开更多
关键词 thermal bridges Dynamic calculation thermal delay Cooling load Computational design method
原文传递
Investigation the Correlation between Thermal Bridging and Geometries in Concrete Buildings
2
作者 Ali Vaseghi Craig Capano 《Journal of Building Construction and Planning Research》 2023年第4期87-100,共14页
This article focuses on the investigation of the correlation between thermal bridging and various geometric configurations. The article employs QuickField software for conducting three-dimensional steady-state heat tr... This article focuses on the investigation of the correlation between thermal bridging and various geometric configurations. The article employs QuickField software for conducting three-dimensional steady-state heat transfer simulations to investigate the thermal behaviors of diverse geometric shapes. Significantly, this study involves the simulation of four distinct geometries including concrete circular, square, rectangular, and triangular column through an insulated concrete layer while all geometries maintain the consistent surface areas. The simulations yield findings indicating that circular thermal bridging has the best thermal performance, while rectangular thermal bridging displays comparatively the lowest thermal efficiency. Furthermore, the results indicate that alterations in the perimeter of thermal bridge interfaces, while maintaining a constant area, exert a more pronounced influence on the thermal performance of the geometries compared to proportional changes in area while preserving the perimeter. The study’s findings aid building designers and architects in creating more energy-efficient structural and architectural elements by incorporating thermally efficient geometries and forms. . 展开更多
关键词 thermal Bridging Heat Flux Building Energy Building Envelope Concrete Building
下载PDF
Eliminating Fastener Thermal Bridging in Low Slope Roofs: Energy Efficiency Savings versus Installation Costs
3
作者 Thomas J. Taylor 《Open Journal of Energy Efficiency》 2020年第2期94-110,共17页
Low-slope roofing assemblies include a wide range of insulation and single ply membrane attachment methods. Previous studies have shown that mechanical attachment using metal fasteners leads to significant thermal bri... Low-slope roofing assemblies include a wide range of insulation and single ply membrane attachment methods. Previous studies have shown that mechanical attachment using metal fasteners leads to significant thermal bridging and consequent loss of insulation value and reduction of long term thermal efficiency. This study calculates the costs associated with mechanical attachment in terms of lost insulation value, increased long-term energy costs, and the material and labor costs associated with installation of these common systems. Energy efficiency reductions using metal fasteners were modeled for eight US cities in a range of climate zones. From the data, it was possible to calculate target costs (labor plus materials) that would make adhered systems cost effective. There are many options available to adhere single ply roof system components, such as solvent-based adhesives and low-rise urethane foams, together with different application approaches such as broom, spray, and ribbon methods. The cost targets derived in this study can help optimize the use of such materials and application methods such that the thermal bridging due to fasteners could be substantially reduced or eliminated. 展开更多
关键词 Energy Efficiency thermal Bridging Roof Assemblies
下载PDF
Lecablock, an Alternative Construction Material for the Exterior Walls of Passive House
4
作者 Osama A.B.Hassan Petra Jonsson 《Journal of Building Construction and Planning Research》 2014年第2期96-108,共13页
In this paper it is attempted to investigate the Leca blocks as sustainable construction material for the exterior walls of passive house. The building physical properties of Leca design wall structure are studied alo... In this paper it is attempted to investigate the Leca blocks as sustainable construction material for the exterior walls of passive house. The building physical properties of Leca design wall structure are studied along with the environmental impact and load-bearing capacity. To compare the results, a similar analysis is carried out considering the traditional wooden wall construction of passive houses. The results showed that Leca design wall structure can be an alternative sustainable solution to the traditional wooden wall structure of passive house, mainly due to its low U-value, its ability to handle moisture, and comparable structural load-bearing capacity. However, the wooden wall structure is more environmentally friendly than the Leca blocks due to its lower emissions to the environment and reduced energy use, especially during the manufacturing process. 展开更多
关键词 U-VALUE MOISTURE thermal bridges Passive House Energy Efficiency Load-Bearing Capacity
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部