For the purpose to facilitate development of high-speed Spindle Units (SUs) running on rolling bearings, we have developed a beam element model, algorithms, and software for computer analysis of thermal characteristic...For the purpose to facilitate development of high-speed Spindle Units (SUs) running on rolling bearings, we have developed a beam element model, algorithms, and software for computer analysis of thermal characteristics of SUs. The thermal model incorporates a model of heat generation in rolling bearings, a model of heat transfer from bearings, and models for estimation of temperature and temperature deformations of SU elements. We have carried out experimental test and made quantitative evaluation of the effect of operation conditions on friction and thermal characteristics of the SUs of grinding and turning machines of typical structures. It is found that the operation conditions make stronger effect on SU temperatures when rpm increases. A comparison between the results of analysis and experiment proves their good mutual correspondence and allows us to recommend application of the models and software developed for design and research of high-speed SUs running on rolling bearings.展开更多
Maize (Zea mays L.) is one of the three major food crops and an important source of carbohydrates for maintaining food security around the world.Plant height (H),stem diameter (SD),leaf area index (LAI) and dry matter...Maize (Zea mays L.) is one of the three major food crops and an important source of carbohydrates for maintaining food security around the world.Plant height (H),stem diameter (SD),leaf area index (LAI) and dry matter (DM) are important growth parameters that influence maize production.However,the combined effect of temperature and light on maize growth is rarely considered in crop growth models.Ten maize growth models based on the modified logistic growth equation (Mlog) and the Mitscherlich growth equation (Mit) were proposed to simulate the H,SD,LAI and DM of maize under different mulching practices based on experimental data from 2015–2018.Either the accumulative growing degree-days (AGDD),helio thermal units (HTU),photothermal units (PTU) or photoperiod thermal units (PPTU,first proposed here) was used as a single driving factor in the models;or AGDD was combined with either accumulative actual solar hours (ASS),accumulative photoperiod response (APR,first proposed here) or accumulative maximum possible sunshine hours (ADL) as the dual driving factors in the models.The model performances were evaluated using seven statistical indicators and a global performance index.The results showed that the three mulching practices significantly increased the maize growth rates and the maximum values of the growth curves compared with non-mulching.Among the four single factor-driven models,the overall performance of the Mlog_(PTU)Model was the best,followed by the Mlog_(AGDD)Model.The Mlog_(PPTU)Model was better than the Mlog_(AGDD)Model in simulating SD and LAI.Among the 10 models,the overall performance of the Mlog_(AGDD–APR)Model was the best,followed by the Mlog_(AGDD–ASS)Model.Specifically,the Mlog_(AGDD–APR)Model performed the best in simulating H and LAI,while the Mlog_(AGDD–ADL)and Mlog_(AGDD–ASS)models performed the best in simulating SD and DM,respectively.In conclusion,the modified logistic growth equations with AGDD and either APR,ASS or ADL as the dual driving factors outperformed the commonly used modified logistic growth model with AGDD as a single driving factor in simulating maize growth.展开更多
Improving the primary steam parameters is one of the most direct ways to improve the cycle efficiency of a powergeneration system. In the present study, the typical problem connected to the excessively high superheat ...Improving the primary steam parameters is one of the most direct ways to improve the cycle efficiency of a powergeneration system. In the present study, the typical problem connected to the excessively high superheat degree ofextraction steam in an ultra-supercritical (USC) double-reheat unit is considered. Using a 1000 MW power plantas an example, two systems (case 1 and case 2) are proposed, both working in combination with a regenerativesteam turbine. The thermal performances of these two systems are compared with that of the original systemthrough a heat balance method and an exergy balance strategy. The results reveal that the two coupled systemscan significantly reduce the superheat degree of extraction steam, turbine heat rate, and coal consumption of theunit and improve the energy utilization efficiency. These results will provide useful theoretical guidance to futureinvestigators wishing to address the general problem relating to energy conservation and modelling of the coupledextraction steam regenerative system of USC double-reheat units.展开更多
The solar and wind renewable energy is developing very rapidly to fulfill the energy gap. This specific increasing share of renewable energy is a reaction to the ecological trepidations to conciliate economics with se...The solar and wind renewable energy is developing very rapidly to fulfill the energy gap. This specific increasing share of renewable energy is a reaction to the ecological trepidations to conciliate economics with security due to the new challenges in power system supply. In solar and wind renewable energy, the only partially predictable is the output with very low controllability which creates unit commitment problems in thermal units. In this research paper, a different linear formulation via mixed integer is presented that only requires “binary variables” and restraints concerning earlier stated models. The framework of this model allows precisely the costs of time-dependent startup & intertemporal limitations, for example, minimum up & down times and a ramping limit. To solve the unit commitment problem efficiently, a commercially available linear programming of mixed-integer is applied for sizeable practical scale. The results of the simulation are shown in conclusions.展开更多
In this study,based on the established heat transfer and mechanical stress models,thermal stress distribution of glazing unit filled with paraffin was studied for various temperature differences between indoor and out...In this study,based on the established heat transfer and mechanical stress models,thermal stress distribution of glazing unit filled with paraffin was studied for various temperature differences between indoor and outdoor conditions.The strain produced on the surface of glazing unit filled with paraffin varies greatly in the outdoor temperature range of-30℃-40 ℃.Furthermore,phase change material(PCM) layer between the glass panes significantly affects the strain values at different temperatures,which can respectively reach up to about 250×10^(-6) and down to-300×10^(-6) for tensile and compressive strains once the paraffin is in liquid state.Additionally,impacts of boundary conditions on the strain values are more pronounced within the distance of 0.01 m from the edges of the glazing window.The presented model and outcomes can be used as a guide to simulate thermal stress in glazing units filled with paraffin.展开更多
The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation...The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time展开更多
Both the modeling and the load regulation capacity prediction of a supercritical power plant are investigated in this paper. Firstly, an indirect identification method based on subspace identification method is propos...Both the modeling and the load regulation capacity prediction of a supercritical power plant are investigated in this paper. Firstly, an indirect identification method based on subspace identification method is proposed. The obtained identification model is verified by the actual operation data and the dynamic characteristics of the system are well reproduced. Secondly, the model is used to predict the load regulation capacity of thermal power unit. The power, main steam pressure, main steam temperature and other parameters are simulated respectively when the unit load is going up and down. Under the actual constraints, the load regulation capacity of thermal power unit can be predicted quickly.展开更多
In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing...In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing power grid operation.In this paper,an electrothermal integrated energy system including heat pump and thermal storage units was proposed.The scheduling model was based on the load data and the output characteristics of power units,each power unit capacity was programmed without constraints,and the proposed scheduling model was compared with the traditional combined heat and power scheduling model.Results showed that the investment and pollutant discharge of the system was reduced respectively.Wind power was fully absorbed.Compared with the traditional thermal power unit,the proportion of the output was significantly decreased by the proposed model.The proposed system could provide a new prospect for wind power absorption and environment protection.展开更多
The study is on the use of thermal desorption unit in the remediation of contaminated soils located at Beneku in Ndokwa East local government area of Delta state. This method uses heat to vaporize the contaminants, an...The study is on the use of thermal desorption unit in the remediation of contaminated soils located at Beneku in Ndokwa East local government area of Delta state. This method uses heat to vaporize the contaminants, and as such only works for volatile contaminants. Air quality samples around the thermal desorption Unit (TDU), used for the treatment of hydrocarbon impacted soils were taken at six (6) different sampling points (Stations). The sampling points were 100 m apart beginning from 0 m which was the closest to the TDU. The results showed that the mean values of SO<sub>2</sub> were 0.01 ppm for both the dry and wet seasons and it is within the FMEnv limit of 0.01. The mean concentration of NO<sub>2</sub> in the dry season was 0.25 μg/m<sup>3</sup> and in the wet season it was 0.18 μg/m<sup>3</sup>, which were above the FMEnv limit of 0.06 μg/m<sup>3</sup>. It is a strong oxidizing agent that reacts with air/water to form corrosive nitric acid, as well as toxic organic nitrates. The mean concentration of CO<sub>2</sub> recorded in the dry season was 11.52 ppm and that for the wet season was 10.53 ppm, which were slightly above the FMEnv limit of 10.00 ppm. The levels of SPM 2.5 recorded in the study show a concentration of 132.07 μg/m<sup>3</sup> in the dry season and 95.93 μg/m<sup>3</sup> in the wet season while those for SPM 10 had 102.17 μg/m<sup>3</sup> in the dry season and 91.33 μg/m<sup>3</sup> in the wet season. The level of the VOC recorded across the study area was significantly low (0.11 μg/m<sup>3</sup>). The mean H<sub>2</sub>S concentration recorded across the study area was low (0.01 μg/m<sup>3</sup>). Several health risks have been associated with SPM. Inhaling SPM affects respiratory and cardiovascular systems in both children and adults. Fine SPM (such as PM 2.5 particulate) can penetrate into the lungs and blood streams when inhaled, resulting to respiratory problems, heart attack, lung cancer and even death, while exposure to low levels of H<sub>2</sub>S can induce headaches as well as breathing difficulties in some asthmatic patients.展开更多
China’s electric power industry as a basic industry, plays an important role in the longterm, sustained and healthy development of the whole national economy. China’s electric power industry attained great achieveme...China’s electric power industry as a basic industry, plays an important role in the longterm, sustained and healthy development of the whole national economy. China’s electric power industry attained great achievement in technology and economical results during the past eight years from 1987-1995. The total national installed generating capacity increased from 102.897 GW in 1987 to more than 200 GW in March, 1995.展开更多
After a thorough demonstration in Panshan Thermal Power Plant, the 500 MW super critical pressure unit simulator developed by the Simulation & Control Institute under the North China University of Electric Power w...After a thorough demonstration in Panshan Thermal Power Plant, the 500 MW super critical pressure unit simulator developed by the Simulation & Control Institute under the North China University of Electric Power was accepted by experts from the North China Electric Power Group Company on 3rd August 1996.展开更多
Traditional heat conductive epoxy composites often fall short in meeting the escalating heat dissipation demands of large-power,high-frequency,and highvoltage insulating packaging applications,due to the challenge of ...Traditional heat conductive epoxy composites often fall short in meeting the escalating heat dissipation demands of large-power,high-frequency,and highvoltage insulating packaging applications,due to the challenge of achieving high thermal conductivity(k),desirable dielectric performance,and robust thermomechanical properties simultaneously.Liquid crystal epoxy(LCE)emerges as a unique epoxy,exhibiting inherently high k achieved through the self-assembly of mesogenic units into ordered structures.This characteristic enables liquid crystal epoxy to retain all the beneficial physical properties of pristine epoxy,while demonstrating a prominently enhanced k.As such,liquid crystal epoxy materials represent a promising solution for thermal management,with potential to tackle the critical issues and technical bottlenecks impeding the increasing miniaturization of microelectronic devices and electrical equipment.This article provides a comprehensive review on recent advances in liquid crystal epoxy,emphasizing the correlation between liquid crystal epoxy’s microscopic arrangement,organized mesoscopic domain,k,and relevant physical properties.The impacts of LC units and curing agents on the development of ordered structure are discussed,alongside the consequent effects on the k,dielectric,thermal,and other properties.External processing factors such as temperature and pressure and their influence on the formation and organization of structured domains are also evaluated.Finally,potential applications that could benefit from the emergence of liquid crystal epoxy are reviewed.展开更多
At present,air handling units are usually used indoors to improve the indoor environment quality.However,while introducing fresh air to improve air quality,air velocity has a certain impact on the occupants’thermal c...At present,air handling units are usually used indoors to improve the indoor environment quality.However,while introducing fresh air to improve air quality,air velocity has a certain impact on the occupants’thermal comfort.Therefore,it is necessary to explore the optimization of air-fluid-body interaction dynamics.In this study,the indoor air flow was changed by changing the opening and closing degree of the blower,and the thermal manikin is introduced to objectively evaluate the human thermal comfort under different air velocities.The main experimental results show that the air change rate increases with the increase of the opening and closing degree of the blower considering an ACH(air changes per hour)range between 3.8 and 10.For a better prediction,a linear correlation with a coefficient of 0.995 is proposed.As the blower’s opening is adjusted to 20%,25%,30%,35%,and 40%,the air velocity sensor positioned directly beneath the air inlet records average velocities of 0.19,0.20,0.21,0.28,and 0.34 m/s over four hours,respectively.Observations on thermal comfort and the average sensation experienced by individuals indicate an initial increase followed by a decline when the blower’s operation begins,with optimal conditions achieved at a 35%opening.These findings offer valuable insights for future indoor air ventilation and heat transfer design strategies.展开更多
The complete set of 300 MW No.2 unit of Qingdao Thermal Power Plant started successfully on the first trail up to the national outstanding standard on l
A new approach in combination of the effective medium theory with the equivalent unit in numerical simulation was developed to study the effective thermal conductivity of porous ceramics. The finite element method was...A new approach in combination of the effective medium theory with the equivalent unit in numerical simulation was developed to study the effective thermal conductivity of porous ceramics. The finite element method was used to simulate the heat transfer process which enables to acquire accurate results through highly complicated modeling and intensive computation. An alternative approach to mesh the material into small cells was also presented. The effective medium theory accounts for the effective thermal conductivity of cells while the equivalent unit is subsequently applied in numerical simulation to analyze the effective thermal conductivity of the porous ceramics. A new expression for the effective thermal conductivity, allowing for some structure factors such as volume fraction of pores and thermal conductivity, was put forward, and the results of its application was proved to be close to those of the mathematical simulation.展开更多
The novel dicyanate ester resin containing naphthalene unit (DNCY) was synthesized, and characterized by FT-IR, 1H-NMR, 13C-NMR and elemental analysis (EA). The thermal properties of DNCY resin was studied by thermal...The novel dicyanate ester resin containing naphthalene unit (DNCY) was synthesized, and characterized by FT-IR, 1H-NMR, 13C-NMR and elemental analysis (EA). The thermal properties of DNCY resin was studied by thermal degradation analysis at a heating rate of 10 C /min-1 in N2 and air. The DNCY resin exhibited better thermal and thermal-oxidative stability than bisphenol A dicyanate (BACY) resin.展开更多
文摘For the purpose to facilitate development of high-speed Spindle Units (SUs) running on rolling bearings, we have developed a beam element model, algorithms, and software for computer analysis of thermal characteristics of SUs. The thermal model incorporates a model of heat generation in rolling bearings, a model of heat transfer from bearings, and models for estimation of temperature and temperature deformations of SU elements. We have carried out experimental test and made quantitative evaluation of the effect of operation conditions on friction and thermal characteristics of the SUs of grinding and turning machines of typical structures. It is found that the operation conditions make stronger effect on SU temperatures when rpm increases. A comparison between the results of analysis and experiment proves their good mutual correspondence and allows us to recommend application of the models and software developed for design and research of high-speed SUs running on rolling bearings.
基金funded by the National Natural Science Foundation of China (51879226)the Chinese Universities Scientific Fund (2452020018)。
文摘Maize (Zea mays L.) is one of the three major food crops and an important source of carbohydrates for maintaining food security around the world.Plant height (H),stem diameter (SD),leaf area index (LAI) and dry matter (DM) are important growth parameters that influence maize production.However,the combined effect of temperature and light on maize growth is rarely considered in crop growth models.Ten maize growth models based on the modified logistic growth equation (Mlog) and the Mitscherlich growth equation (Mit) were proposed to simulate the H,SD,LAI and DM of maize under different mulching practices based on experimental data from 2015–2018.Either the accumulative growing degree-days (AGDD),helio thermal units (HTU),photothermal units (PTU) or photoperiod thermal units (PPTU,first proposed here) was used as a single driving factor in the models;or AGDD was combined with either accumulative actual solar hours (ASS),accumulative photoperiod response (APR,first proposed here) or accumulative maximum possible sunshine hours (ADL) as the dual driving factors in the models.The model performances were evaluated using seven statistical indicators and a global performance index.The results showed that the three mulching practices significantly increased the maize growth rates and the maximum values of the growth curves compared with non-mulching.Among the four single factor-driven models,the overall performance of the Mlog_(PTU)Model was the best,followed by the Mlog_(AGDD)Model.The Mlog_(PPTU)Model was better than the Mlog_(AGDD)Model in simulating SD and LAI.Among the 10 models,the overall performance of the Mlog_(AGDD–APR)Model was the best,followed by the Mlog_(AGDD–ASS)Model.Specifically,the Mlog_(AGDD–APR)Model performed the best in simulating H and LAI,while the Mlog_(AGDD–ADL)and Mlog_(AGDD–ASS)models performed the best in simulating SD and DM,respectively.In conclusion,the modified logistic growth equations with AGDD and either APR,ASS or ADL as the dual driving factors outperformed the commonly used modified logistic growth model with AGDD as a single driving factor in simulating maize growth.
基金the Shandong Electric Power Engineering Consulting Institute science and technology project(Grant No.37-K2014-33).
文摘Improving the primary steam parameters is one of the most direct ways to improve the cycle efficiency of a powergeneration system. In the present study, the typical problem connected to the excessively high superheat degree ofextraction steam in an ultra-supercritical (USC) double-reheat unit is considered. Using a 1000 MW power plantas an example, two systems (case 1 and case 2) are proposed, both working in combination with a regenerativesteam turbine. The thermal performances of these two systems are compared with that of the original systemthrough a heat balance method and an exergy balance strategy. The results reveal that the two coupled systemscan significantly reduce the superheat degree of extraction steam, turbine heat rate, and coal consumption of theunit and improve the energy utilization efficiency. These results will provide useful theoretical guidance to futureinvestigators wishing to address the general problem relating to energy conservation and modelling of the coupledextraction steam regenerative system of USC double-reheat units.
文摘The solar and wind renewable energy is developing very rapidly to fulfill the energy gap. This specific increasing share of renewable energy is a reaction to the ecological trepidations to conciliate economics with security due to the new challenges in power system supply. In solar and wind renewable energy, the only partially predictable is the output with very low controllability which creates unit commitment problems in thermal units. In this research paper, a different linear formulation via mixed integer is presented that only requires “binary variables” and restraints concerning earlier stated models. The framework of this model allows precisely the costs of time-dependent startup & intertemporal limitations, for example, minimum up & down times and a ramping limit. To solve the unit commitment problem efficiently, a commercially available linear programming of mixed-integer is applied for sizeable practical scale. The results of the simulation are shown in conclusions.
基金Project(52078110) supported by the National Natural Science Foundation of ChinaProject(2018KYQD15) supported by Beibu Gulf Universityt,China。
文摘In this study,based on the established heat transfer and mechanical stress models,thermal stress distribution of glazing unit filled with paraffin was studied for various temperature differences between indoor and outdoor conditions.The strain produced on the surface of glazing unit filled with paraffin varies greatly in the outdoor temperature range of-30℃-40 ℃.Furthermore,phase change material(PCM) layer between the glass panes significantly affects the strain values at different temperatures,which can respectively reach up to about 250×10^(-6) and down to-300×10^(-6) for tensile and compressive strains once the paraffin is in liquid state.Additionally,impacts of boundary conditions on the strain values are more pronounced within the distance of 0.01 m from the edges of the glazing window.The presented model and outcomes can be used as a guide to simulate thermal stress in glazing units filled with paraffin.
文摘The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time
文摘Both the modeling and the load regulation capacity prediction of a supercritical power plant are investigated in this paper. Firstly, an indirect identification method based on subspace identification method is proposed. The obtained identification model is verified by the actual operation data and the dynamic characteristics of the system are well reproduced. Secondly, the model is used to predict the load regulation capacity of thermal power unit. The power, main steam pressure, main steam temperature and other parameters are simulated respectively when the unit load is going up and down. Under the actual constraints, the load regulation capacity of thermal power unit can be predicted quickly.
基金the fund program of research on re-electrification(heat pump clean heating)to promote the new energy consumption in Shaanxi power grid(5226KY18002P).
文摘In view of the Three North areas existing wind power absorption and environment pollution problems,the previous scholars have improved the wind abandon problem by adding electrothermal coupling equipment or optimizing power grid operation.In this paper,an electrothermal integrated energy system including heat pump and thermal storage units was proposed.The scheduling model was based on the load data and the output characteristics of power units,each power unit capacity was programmed without constraints,and the proposed scheduling model was compared with the traditional combined heat and power scheduling model.Results showed that the investment and pollutant discharge of the system was reduced respectively.Wind power was fully absorbed.Compared with the traditional thermal power unit,the proportion of the output was significantly decreased by the proposed model.The proposed system could provide a new prospect for wind power absorption and environment protection.
文摘The study is on the use of thermal desorption unit in the remediation of contaminated soils located at Beneku in Ndokwa East local government area of Delta state. This method uses heat to vaporize the contaminants, and as such only works for volatile contaminants. Air quality samples around the thermal desorption Unit (TDU), used for the treatment of hydrocarbon impacted soils were taken at six (6) different sampling points (Stations). The sampling points were 100 m apart beginning from 0 m which was the closest to the TDU. The results showed that the mean values of SO<sub>2</sub> were 0.01 ppm for both the dry and wet seasons and it is within the FMEnv limit of 0.01. The mean concentration of NO<sub>2</sub> in the dry season was 0.25 μg/m<sup>3</sup> and in the wet season it was 0.18 μg/m<sup>3</sup>, which were above the FMEnv limit of 0.06 μg/m<sup>3</sup>. It is a strong oxidizing agent that reacts with air/water to form corrosive nitric acid, as well as toxic organic nitrates. The mean concentration of CO<sub>2</sub> recorded in the dry season was 11.52 ppm and that for the wet season was 10.53 ppm, which were slightly above the FMEnv limit of 10.00 ppm. The levels of SPM 2.5 recorded in the study show a concentration of 132.07 μg/m<sup>3</sup> in the dry season and 95.93 μg/m<sup>3</sup> in the wet season while those for SPM 10 had 102.17 μg/m<sup>3</sup> in the dry season and 91.33 μg/m<sup>3</sup> in the wet season. The level of the VOC recorded across the study area was significantly low (0.11 μg/m<sup>3</sup>). The mean H<sub>2</sub>S concentration recorded across the study area was low (0.01 μg/m<sup>3</sup>). Several health risks have been associated with SPM. Inhaling SPM affects respiratory and cardiovascular systems in both children and adults. Fine SPM (such as PM 2.5 particulate) can penetrate into the lungs and blood streams when inhaled, resulting to respiratory problems, heart attack, lung cancer and even death, while exposure to low levels of H<sub>2</sub>S can induce headaches as well as breathing difficulties in some asthmatic patients.
文摘China’s electric power industry as a basic industry, plays an important role in the longterm, sustained and healthy development of the whole national economy. China’s electric power industry attained great achievement in technology and economical results during the past eight years from 1987-1995. The total national installed generating capacity increased from 102.897 GW in 1987 to more than 200 GW in March, 1995.
文摘After a thorough demonstration in Panshan Thermal Power Plant, the 500 MW super critical pressure unit simulator developed by the Simulation & Control Institute under the North China University of Electric Power was accepted by experts from the North China Electric Power Group Company on 3rd August 1996.
基金supported by funding from the National Natural Science Foundation of China(No.52277028,51577154,U1903133)
文摘Traditional heat conductive epoxy composites often fall short in meeting the escalating heat dissipation demands of large-power,high-frequency,and highvoltage insulating packaging applications,due to the challenge of achieving high thermal conductivity(k),desirable dielectric performance,and robust thermomechanical properties simultaneously.Liquid crystal epoxy(LCE)emerges as a unique epoxy,exhibiting inherently high k achieved through the self-assembly of mesogenic units into ordered structures.This characteristic enables liquid crystal epoxy to retain all the beneficial physical properties of pristine epoxy,while demonstrating a prominently enhanced k.As such,liquid crystal epoxy materials represent a promising solution for thermal management,with potential to tackle the critical issues and technical bottlenecks impeding the increasing miniaturization of microelectronic devices and electrical equipment.This article provides a comprehensive review on recent advances in liquid crystal epoxy,emphasizing the correlation between liquid crystal epoxy’s microscopic arrangement,organized mesoscopic domain,k,and relevant physical properties.The impacts of LC units and curing agents on the development of ordered structure are discussed,alongside the consequent effects on the k,dielectric,thermal,and other properties.External processing factors such as temperature and pressure and their influence on the formation and organization of structured domains are also evaluated.Finally,potential applications that could benefit from the emergence of liquid crystal epoxy are reviewed.
基金supported by the China Scholarship Council(Grant Number 202208120025).
文摘At present,air handling units are usually used indoors to improve the indoor environment quality.However,while introducing fresh air to improve air quality,air velocity has a certain impact on the occupants’thermal comfort.Therefore,it is necessary to explore the optimization of air-fluid-body interaction dynamics.In this study,the indoor air flow was changed by changing the opening and closing degree of the blower,and the thermal manikin is introduced to objectively evaluate the human thermal comfort under different air velocities.The main experimental results show that the air change rate increases with the increase of the opening and closing degree of the blower considering an ACH(air changes per hour)range between 3.8 and 10.For a better prediction,a linear correlation with a coefficient of 0.995 is proposed.As the blower’s opening is adjusted to 20%,25%,30%,35%,and 40%,the air velocity sensor positioned directly beneath the air inlet records average velocities of 0.19,0.20,0.21,0.28,and 0.34 m/s over four hours,respectively.Observations on thermal comfort and the average sensation experienced by individuals indicate an initial increase followed by a decline when the blower’s operation begins,with optimal conditions achieved at a 35%opening.These findings offer valuable insights for future indoor air ventilation and heat transfer design strategies.
文摘The complete set of 300 MW No.2 unit of Qingdao Thermal Power Plant started successfully on the first trail up to the national outstanding standard on l
文摘A new approach in combination of the effective medium theory with the equivalent unit in numerical simulation was developed to study the effective thermal conductivity of porous ceramics. The finite element method was used to simulate the heat transfer process which enables to acquire accurate results through highly complicated modeling and intensive computation. An alternative approach to mesh the material into small cells was also presented. The effective medium theory accounts for the effective thermal conductivity of cells while the equivalent unit is subsequently applied in numerical simulation to analyze the effective thermal conductivity of the porous ceramics. A new expression for the effective thermal conductivity, allowing for some structure factors such as volume fraction of pores and thermal conductivity, was put forward, and the results of its application was proved to be close to those of the mathematical simulation.
文摘The novel dicyanate ester resin containing naphthalene unit (DNCY) was synthesized, and characterized by FT-IR, 1H-NMR, 13C-NMR and elemental analysis (EA). The thermal properties of DNCY resin was studied by thermal degradation analysis at a heating rate of 10 C /min-1 in N2 and air. The DNCY resin exhibited better thermal and thermal-oxidative stability than bisphenol A dicyanate (BACY) resin.