A Farmer ion chamber with an air cavity volume is the most widely used dosimeter for accurate dose determinations in radiotherapy. The quantity of ionization in the cavity volume occurred a given radiation dose has to...A Farmer ion chamber with an air cavity volume is the most widely used dosimeter for accurate dose determinations in radiotherapy. The quantity of ionization in the cavity volume occurred a given radiation dose has to be corrected to the cavity air temperature according to a dosimetry protocol because the mass of air in the cavity volume is subject to atmospheric variations. In the present study, we aim to measure the thermal equilibration time in the cavity volume of a Farmer ion chamber for the routine dosimetry. The Farmer ion chamber’s electrode was replaced by a thin thermocouple and coated by the PMMA for a waterproofing so that the measurement of the temperature in the cavity performed in water. As a result of the measurement, A Farmer ion chamber in thermal equilibrium with waterproofing equilibrates rapidly, followed by an exponential fall-off. In water, equilibration to less than 10% of the initial temperature difference required only a few minutes. Thermal equilibrium time is hardly affected by the room temperature change.展开更多
We consider a typical master equation describing thermal time-evolution. In parallel, we also consider a quasi static canonical description of the same problem. We are able to devise a way of numerically comparing the...We consider a typical master equation describing thermal time-evolution. In parallel, we also consider a quasi static canonical description of the same problem. We are able to devise a way of numerically comparing these two treatments and concoct a distance-measure between them. In this way, one is in a position to know how far or close equilibrium and off-equilibrium can get. The first, rather surprising observation, is that our systems lose structural details as N grows. Also, the time-evolution of the distance between the two pertinent probability distributions is quite sensitive to the heating-cooling process.展开更多
文摘A Farmer ion chamber with an air cavity volume is the most widely used dosimeter for accurate dose determinations in radiotherapy. The quantity of ionization in the cavity volume occurred a given radiation dose has to be corrected to the cavity air temperature according to a dosimetry protocol because the mass of air in the cavity volume is subject to atmospheric variations. In the present study, we aim to measure the thermal equilibration time in the cavity volume of a Farmer ion chamber for the routine dosimetry. The Farmer ion chamber’s electrode was replaced by a thin thermocouple and coated by the PMMA for a waterproofing so that the measurement of the temperature in the cavity performed in water. As a result of the measurement, A Farmer ion chamber in thermal equilibrium with waterproofing equilibrates rapidly, followed by an exponential fall-off. In water, equilibration to less than 10% of the initial temperature difference required only a few minutes. Thermal equilibrium time is hardly affected by the room temperature change.
文摘We consider a typical master equation describing thermal time-evolution. In parallel, we also consider a quasi static canonical description of the same problem. We are able to devise a way of numerically comparing these two treatments and concoct a distance-measure between them. In this way, one is in a position to know how far or close equilibrium and off-equilibrium can get. The first, rather surprising observation, is that our systems lose structural details as N grows. Also, the time-evolution of the distance between the two pertinent probability distributions is quite sensitive to the heating-cooling process.