In general, during the production of compacted graphite iron (CGI), the active residual magnesium reduces and the effect of inoculation fades after magnesium treatment. In this paper, characteristics of the thermal an...In general, during the production of compacted graphite iron (CGI), the active residual magnesium reduces and the effect of inoculation fades after magnesium treatment. In this paper, characteristics of the thermal analysis curve of CGI are compared with those of ductile iron and grey cast iron. The fading effect on the compacted graphite percentage and thermal analysis curve were also studied. Results indicate that the undercooling of CGI is as low as that of ductile iron, but CGI shows evident recalescence. In fading process, the magnesium element acts with oxygen. For a decrease in magnesium content, both the compacted graphite percentage and the austenitic liquidus temperature increase. The temperature of eutectic undercooling (TEU) decreases before the flake graphite appears. After that, TEU increases quickly, up to as high as 20℃, and then gradually decreases. The evolution of recalescence degree is opposite to that of TEU.展开更多
Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurem...Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurements are required. Electron Spin Resonance (ESR) is a well-established Reference Standard Dosimetry system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental work, PGA solid state dosimeter (SSD) has been investigated using ESR spectroscopy to study the gamma radiation response of this material and to evaluate its dosimetric characteristics: dose response, room temperature fading, heat treatment effect during post-irradiation storage. Results obtained up to now confirm that PGA seems to be suitable material for ESR dosimetry applications.展开更多
A new micro-spherical conjugated macrocycle polymer(P[5]-TFB-CMP)was prepared by the condensation reaction between dihydrazide functionalized pillar[5]arene and 1,3,5-triformylbenzene under ambient conditions.P[5]-TFB...A new micro-spherical conjugated macrocycle polymer(P[5]-TFB-CMP)was prepared by the condensation reaction between dihydrazide functionalized pillar[5]arene and 1,3,5-triformylbenzene under ambient conditions.P[5]-TFB-CMP exhibits large surface area with excellent thermal stability and has been used as additive to prepare composite PMMA film of photochromic naphthopyrans.The results showed that the addition of P[5]-TFB-CMP could dramatically accelerate the thermal fading rate of the photochromic composite film by up to 12 times.This is a new strategy to overcome the drawback of the matrix effect.展开更多
文摘In general, during the production of compacted graphite iron (CGI), the active residual magnesium reduces and the effect of inoculation fades after magnesium treatment. In this paper, characteristics of the thermal analysis curve of CGI are compared with those of ductile iron and grey cast iron. The fading effect on the compacted graphite percentage and thermal analysis curve were also studied. Results indicate that the undercooling of CGI is as low as that of ductile iron, but CGI shows evident recalescence. In fading process, the magnesium element acts with oxygen. For a decrease in magnesium content, both the compacted graphite percentage and the austenitic liquidus temperature increase. The temperature of eutectic undercooling (TEU) decreases before the flake graphite appears. After that, TEU increases quickly, up to as high as 20℃, and then gradually decreases. The evolution of recalescence degree is opposite to that of TEU.
文摘Reference Standard Dosimeters are used to calibrate radiation environments and routine dosimeters. It can also be used in routine dosimetry applications for radiation processing where higher quality dosimetry measurements are required. Electron Spin Resonance (ESR) is a well-established Reference Standard Dosimetry system in industrial applications of ionising radiation, and its use is also proposed in radiation therapy and accident dosimetry. In the present experimental work, PGA solid state dosimeter (SSD) has been investigated using ESR spectroscopy to study the gamma radiation response of this material and to evaluate its dosimetric characteristics: dose response, room temperature fading, heat treatment effect during post-irradiation storage. Results obtained up to now confirm that PGA seems to be suitable material for ESR dosimetry applications.
基金financially supported by Natural Science Foundation of Tianjin(No.18JCYBJC20700)the 111 Project(No.B12015)。
文摘A new micro-spherical conjugated macrocycle polymer(P[5]-TFB-CMP)was prepared by the condensation reaction between dihydrazide functionalized pillar[5]arene and 1,3,5-triformylbenzene under ambient conditions.P[5]-TFB-CMP exhibits large surface area with excellent thermal stability and has been used as additive to prepare composite PMMA film of photochromic naphthopyrans.The results showed that the addition of P[5]-TFB-CMP could dramatically accelerate the thermal fading rate of the photochromic composite film by up to 12 times.This is a new strategy to overcome the drawback of the matrix effect.